• Title/Summary/Keyword: Hemispherical Narrow Gap

Search Result 8, Processing Time 0.02 seconds

An Experimental Study on the Quenching Phenomena of Hemispherical Downward Facing Convex Surfaces with Narrow Gaps (반구형 소형 간극 내에서의 냉각과정에 관한 실험적 연구)

  • Ha, Kwang-Soon;Park, Rae-Joon;Kim, Sang-Baik;Cho, Young-Ro;Kim, Hee-Dong
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.447-452
    • /
    • 2001
  • Quenching phenomena of hemispherical downward facing convex surfaces with narrow gaps have been investigated experimentally. Experiments employed test sections having 1 and 2 mm in gap thickness and 1 atm in system pressure. From interpretations of the temperature and the heat flux history, it was found that the flooding inside the gap was restricted by CCFL phenomena and quenching process was propagated from lower to upper region of the internal copper shell. The ratio of the maximum heat fluxes at 1 mm to 2mm in gap thickness was the almost same that obtained by steady state experiments. The quenching scenario of the hemispherical downward facing surface with narrow gap has been suggested.

  • PDF

Correlation Verification and Revision of Critical Power in a Hemispherical Narrow Gap (구형 간극에서의 임계출력에 관한 상관식 검증 및 보완)

  • Ha Kwang-Soon;Park Rae-Joon;Kim Sang-Baik;Kim Hee-Dong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.411-414
    • /
    • 2002
  • The CHFG(Critical Heat Flux in Cap) test results have been evaluated to quantify the critical powers in hemispherical narrow gaps and Park's correlation has been verified. For verification of the Park's correlation, the critical powers in hemispherical narrow gaps have been measured using water at a pressure of 0.1-0.3 WPa for the hemispherical gap thickness of 1.0mm, and the heated top diameter of 238mm The measured critical powers were compared with Park's and Monde's correlation. As a results, the Park's correlation was most accurate of other correlations, however, estimated the critical powers somewhat larger than measured ones. So, it was suggested that the diameter factor in Park's correlation should be revised.

  • PDF

Saturated Boiling Heat Transfer of Freon-113 in Hemispherical Narrow Space and Implications for Degraded Core Coolability in Reactor Vessel Lower Plenum

  • Bang, Kwang-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.574-579
    • /
    • 1995
  • Saturated boiling heat transfer experiment in a hemispherical narrow space is conducted using Freon-113 to investigate an additional heat removal capability through a hypothetical gap between lower head and degraded core. The narrow space of 1mm consists of a 124mm diameter heated stainless steel hemisphere and a glass outer vessel. Within the hemispherical narrow space large coalesced bubbles are produced and these bubbles rise in random direction, causing liquid flow in from the opposite side to fill the region. Such flow in random direction makes the flow field in the narrow space very chaotic and thus enhance heat transfer. The heat transfer coefficient is higher at lower angle and at higher heat flux. The present study shows that the liquid from upper region can effectively penetrate into the gap and augment the heat removal capability through tile gap.

  • PDF

Correlation Development on Critical Power in a Spherical Narrow Gap (구형 간극에서의 임계 출력에 대한 상관식 개발)

  • Park, Rae-Joon;Ha, Kwang-Soon;Kim, Sang-Baik;Kim, Hee-Dong;Jeong, Ji-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.235-240
    • /
    • 2001
  • The CHFG (Critical Heat Flux in Gap) test results have been evaluated to quantify the critical power in hemispherical narrow gaps and a new correlation has been developed. The CHFG test results have shown that increases in the gap thickness and pressure lead to an increase in critical power. The pressure effect on the critical power was found to be much milder than predictions by CHF correlations of other researches. From the CHFG test results, a new correlation on critical power in the hemispherical gap has been developed using the non-dimensional parameters as follows: $$\frac{qCHF}{{\rho}g^hfg}{\cdot}4\sqrt{\frac{{\rho}_g^2}{g{\sigma}{\Delta}{\rho}}=\frac{0.1042}{1+0.1375({\rho}g/{\rho}l)^{0.21}(D/s)}$$ The developed correlation has been expanded to apply the spherical geometry using the Siemens/KWU's correlation.

  • PDF

An Experimental Study on the CCFL in Narrow Annular Gaps with Large Diameter (곡률 반경이 큰 환상관 간극에서 CCFL에 대한 실험 연구)

  • Lee, Seung-Jin;Jeong, Ji-Hwan;Park, Rae-Joon;Kim, Sang-Baik;Kim, Hee-Dong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.795-800
    • /
    • 2000
  • A CCFL(Counter Current Flow Limit) test have been performed in narrow annular gaps with large diameter, because it has been confirmed that the CCFL phenomena affected the critical power in hemispherical narrow gap geometries from the SONATA(Simulation Of Naturally Arrested Thermal Attack)-IV (In-Vessel)/VISU(Visualization)-II experiments. The objectives of the CCFL experiments are to investigate the small gap sizes(1, 2mm) effect on CCFL under the large diameter condition and to confirm the findings of the VISU-II study that global dryout in hemispherical narrow gaps was induced by the CCFL. The test section was made of acrylic resin to allow visual observation on the two-phase flow behaviors inside annular gaps. It was observed from visualization that a part of water supplied was accumulated in the upper plenum and a significant increase in the differential pressure across the gap was occurred, which was the definition of the CCFL occurrence in this experimental study. From the experimental results in annular gap with large diameter it can be known that an increase in the differential pressure was not big at small air flow-rates. When the CCFL was occurred, the differential pressure across gaps was increased significantly and a water accumulated in the upper plenum. The occurrence of CCFL was correlated using the Wallis parameter.

  • PDF

Counter-Current Flow Limit in Narrow Gap (간극에서의 역방향 유동 제한 현상 연구)

  • Kim, Yong-Hoon;Suh, Kune-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.1054-1060
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

Counter-Current Flow Limit in Narrow Gap (간극에서의 역방향 유동 제한 현상 연구)

  • Kim, Yong-Hoon;Suh, Kune-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.706-712
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

Counter-Current Flow Limit in Narrow Gap (간극에서의 역방향 유동 제한 현상 연구)

  • Kim, Yong-Hoon;Suh, Kune-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.386-392
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the Maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF