• Title/Summary/Keyword: Height of person

Search Result 122, Processing Time 0.022 seconds

A study on walking aids for the blind (시각장애자의 보행지원에 관한 연구)

  • Ham, K.K.;Han, S.H.;Yang, S.Y.;Kim, H.G.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.131-135
    • /
    • 1997
  • We implementated an ultrasonic wave cane for the blind. The cane detect walking obstacle and provide a walking direction. The cane used time of flight method of ultrasonic-wave for a measurement of obstacle distance and fluxgate geomagnetic sensor for guidance of walking direction. This system can detect an obstacle of upward, forward, downward and that warn to the blind with vibration, pitch sound. And the blind can know walking direction to voice output. As a result, the blind could efficiently avoid a exposed obstacle, obstacles beyond knee, an exposed street obstacle, a branch of tree person's height and it is usable search for surrounding land mark.

  • PDF

OPTIMIZATION ALGORITHM FOR AUTOMATIC LAYOUT OF TOWER CRANES

  • Dong-Hoon Lee;Hyun-Min Lee;Jin-Kyu Joo;Sun-Kuk Kim
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1060-1067
    • /
    • 2009
  • The selection and operation of tower cranes at construction sites are dependent on the personal experience of engineers in charge of lifting work. It often causes to overestimate the safety factor resulting in increase of construction cost, or underestimate it resulting in disastrous accident. Therefore, selection of tower cranes needs to consider cost, safety and maximum lifting condition. This study, for resolving such problems, was intended to propose the algorithm designed for even the inexperienced person to select the optimal lifting equipment in timely manner. The algorithm presented herein is an optimization algorithm that enables automatic arrangement of tower crane and minimization of costs by analyzing such conditions as vertical height and lifting load, etc.

  • PDF

A survey on residential environment's improvement plan of silver town by means of applying ubiquitous system (유비쿼터스시스템 적용을 통한 실버타운의 주거환경 개선방안 연구)

  • Lee, Chulgoo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.4
    • /
    • pp.8-14
    • /
    • 2014
  • With the advancement of the industry such as information technology, residential facilities has been consistently achieved high standard. Ubiquitous system has been introduced in apartments nowadays, and it will be general facilities in the near future. However elderly people is not generally accustomed to ubiquitous or internet environment, so degree of ubiquitous system usage is able to be less than young people. This study aims to grasp the relative importance of ubiquitous environment, and offer materials to realize residential environment's improvement of silver towns under investigation through a questionnaire survey. Skin recognition system was most preferred among various functions. Energy management system, protection system of solitude elderly person and security system by CCTV was also preferred at a high rate. Housework part such as cooking aid, height control of sink and basin etc., was not less important system relatively.

People Counting System using Raspberry Pi

  • Ansari, Md Israfil;Shim, Jaechang
    • Journal of Multimedia Information System
    • /
    • v.4 no.4
    • /
    • pp.239-242
    • /
    • 2017
  • This paper proposes a low-cost method for counting people based on blob detection and blob tracking. Here background subtraction is used to detected blob and then the blob is classified with its width and height to specify that the blob is a person. In this system we first define the area of entry and exit point in the video frame. The counting of people starts when midpoint of the people blob crosses the defined point. Finally, total number of people entry and exit from the place is displayed. Experiment result of this proposed system has high accuracy in real-time performance.

Ultimate Strenth Behaviour for Perforated Stiffened Panels under Longitudinal Compressive Load (종방향 압축하중을 받는 선체 유공보강판의 최종강도 거동에 관한 연구)

  • Ko Jae-Yong;Park Joo-Shin;Lee Kye-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.592-600
    • /
    • 2005
  • Ship have cutout inner bottom and girder and floor etc. Ship's structure is used much, and structure strength must be situated, but establish new concept when high stress interacts sometimes fatally the area. There is no big problem usually by aim of weight reduction, a person and change of freight, piping etc.. Because cutout's existence grow up in this place, and elastic buckling strength by load causes large effect in ultimate strength. Therefore, stiffened perforated plate considering buckling strength and ultimate strength is one of important design criteria which must examine when decide structural concept at initial design. Therefore, md, reasonable buckling strength about stiffened perforated plate need to ultimate strength limited design . Calculated ultimate strength varied several web height and cutout's dimension, and thickness in this investigated data. Used program(ANSYS) applied F.E.A code based on finite element method

  • PDF

The Effect of Pelvic Traction and Muscle Energy Technique on Static Standing Balance in Hemiplegia Patients (골반견인과 근 에너지기법이 편마비 환자의 정적선자세에 미치는 영향)

  • Bae, Jun-Ho;Han, Jin-Tae;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.17 no.4
    • /
    • pp.537-557
    • /
    • 2005
  • The purpose of this study was to investigate the effect of pelvic traction and muscle energy technique(MET) for hemiplegic patients on static standing balance. The scale for static standing balance is measured by using mean balance(%), frequence(Hz), sway area($mm^2$), sway path(mm), max sway velocity(mm/s), ant/post sway angle($^{\circ}$), lateral sway angle($^{\circ}$), sway number, change of pelvic height is measured in relation to the height of ASIS and PSIS. The subjects of this study were thirty hemiplegic patients: 15men and 15 women, with an average ages of 50.80 years. The thirty subjects were divided into 3 group of 10 at random ; ten subjects had pelvic traction after bobath therapy (the pelvic traction group), ten subjects had muscle energy technique after bobath therapy (the MET group), and ten subjects had only bobath therapy (the control group). Static standing balance was measured using BPM (balance performance monitor; data print software version 5.3), pelvic height was measured using height measuring with an adjustable horizontal arm. In order to assure the statistical significant of the result, an one-way ANOVA, the paired t-test, and a person's correlation were applied at the.05 level of significance. The results of this study were as follows: 1) The change in pelvic height were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 2) The change in affected and non-affected on weight bearing were not statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p>.05). 3) The change in frequency were statistically significant between the MET group, the control group and the pelvic traction group on pre-treatment and post-treatment(p<.05). 4) The change in sway area were statistically significant between the MET group, the control group and the pelvic traction group on pre-treatment and post-treatment(p<.05). 5) The change in sway pa1h were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 6) The change in max sway velocity were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 7) The change in ant/post sway angle were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 8) The change in lateral sway angle were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). 9) The change in sway number were statistically significant between the pelvic traction group, the MET group and the control group on pre-treatment and post-treatment(p<.05). In conclusion, there was a difference between the experimental group and the control group. In the future, we have to study continuously about pelvic traction and muscle energy technique in hemiplegic patients.

  • PDF

Analysis of the Body Somatotype of Male Athletes and Study on the Improvement of the Fitting for the Upper Body (남자 운동선수의 체형분석과 상의 맞음새 향상을 위한 연구)

  • Park, Eun-Young;Choi, Hei-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.1 s.160
    • /
    • pp.44-56
    • /
    • 2007
  • The aim of this study is to provide fundamental data on the development of dress shirts pattern appropriate for the body types of athletes. The research subjects are 257 athletes from wrestling, bodybuilding, weight lifting, Judo, canoe, rowing. In regards to the category used in the measurement of bust somatotype, there are 48 types directly measured, 4 types indirectly measured, 7 types calculated and 1 bodyweight of type, making it 60 categories in total. The bust somatotype of a sports athlete and general person were compared together and after examining the characteristics of the bust somatotype, the somatotype of sports athlete was divided according to drop. The results of the study are as follows: 1. Questionnaire Results of the questionnaire showed that 63.4% of the respondents chose dress shirt as the most uncomfortable upper garment for athletes. And as for the result of the most uncomfortable body part turned out to be 'the neck is tight'. 2. Somatotype Analysis Results of direct, indirect measurement and the average somatotype of 97 National standard physique were compared. The characteristics of somatotype of athletes with well-developed upper body are that they are taller and have longer upper body and arms than the general person. And also the width of the trunk is wider, the girth bigger and the waist measure relatively slimmer. Looking at sports by category, it we could see that wrestlers were the largest neck parameter and width. Bodybuilders were the largest body parts for most categories. Weight lifting and Judo athletes were the largest waist and buttock. Canoe and rowing athletes were the largest height and arm parts. Dividing the somatotype of athletes according to drop, 72.8% of the research group belonged to the body type that resembled the letter Y.

An Indoor Localization and Guidance System for the Visually Impaired Person Based on Bluetooth 4.0 (시각 장애인을 위한 Bluetooth 4.0 기반의 실내 위치 추정 및 안내 시스템)

  • Bae, Sun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.202-208
    • /
    • 2016
  • The scope of activities of the visually impaired is increasing. But they are not easy to visit the destination safely because the building was complicated and larger than ever. There is a guide system for visually impaired such as GPS and Audio alerts, Braille guide block, Acoustic signaller, etc. But they are not suitable for indoor because most of them are the outdoor guide system. Therefore, in this paper, I propose a system that provides guidance information to the visually impaired using Voice Technology, TTS (Text to Speech) and Haptic Technology, Beacon based on the wireless sensor networks. It informed the visually impaired of guidance information about destination such as distance, height, and obstacle to the destination using the generalized smart phone. The user could be received guide info about searches for the optimal route to the destination using the TTS technology and Haptic technology in test result of the proposed system.

Ergonomic Design of Office Chair (사무실 의자의 인간공학적 디자인)

  • 곽원모;홍성수;정석길;이상도;이동춘;윤훈용
    • Archives of design research
    • /
    • v.12 no.3
    • /
    • pp.73-80
    • /
    • 1999
  • Many domestic users complain about severe pain to the waist, neck, and shoulder as well as work performance because the domestic chair design was developed with western anthropometry dimension and design criteria. Ergonomic design standards are needed for office chair design to reduce stress and poor physical posture for various user body types. In this study, we have suggested design dimensions recommended from previous studies and Korean anthropometry data. We also have reviewed users' preference dimension through measured subjects and analyzed differences between users' preference dimension and the previous design criteria to verify physical appropriateness. We evaluated general office chairs and adjustable chairs which can adjust to fit each person. we also analyzed how each design dimension was reached and affected the human body by evaluation of physical discomfort and comfort. We have found seat height is very important in a workstation. If the seat height is high, it effects the thigh. If width, height, and angle of the backrest are wrong, fatigue to the shoulder, neck, and waist, etc.. As a result of this experiment, we suggested that the height of a seat for Koreans be 425mm for the fixed type and 365-484mm for the adjustable type. Also other design recommendations were suggested in the thesis. In conclusion, our research will be very important in the database because it provides adjustable ranges to fit user's body types in the various design fields.

  • PDF

Comparison of Size between direct-measurement and 3D body scanning (중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구)

  • Cha, Su-Joung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.