• Title/Summary/Keyword: Heavy-Impact Sound

Search Result 140, Processing Time 0.026 seconds

The numerical analysis. of heavy weight impact noise for an apartment house (공동주택 모델링을 통한 중량충격음 예측에 관한 연구)

  • Hwang, Jae-Seung;Moon, Dae-Ho;Yoon, Young-Bae;Hong, Geon-Ho;Park, Hong-Gun;Hong, Sung-Gul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.527-532
    • /
    • 2008
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it Is shown that heavy weight floor impact noise of wail type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wail slab system.

  • PDF

The Numerical Analysis of Heavy Weight Impact Noise for an Apartment House (공동주택 모델링을 통한 중량충격음 예측에 관한 연구)

  • Hwang, Jae-Seung;Moon, Dae-Ho;Park, Hong-Gun;Hong, Sung-Gul;Hong, Geon-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.162-168
    • /
    • 2009
  • In this study, numerical analysis is performed to investigate the sound radiation characteristics of an apartment house according to the type of the slab system. In order to satisfy the boundary condition of the apartment house, the whole floor is modelled with FEM model for three different structural system: wall, RC, flat slab system. From the analytical results, it is shown that heavy weight floor impact noise of wall type slab is larger than that of the other slab systems and the noise radiated from the wall have great effect on the sound pressure level. The results also show that the vibration energy of RC or flat slab system is widely distributed over the whole slab, which is main reason that the noise induced by the slab systems is reduced in comparison with wall slab system.

Analysis of Correlation between the Vibration Transmissions and the Dynamic Characteristics for Floor Impact Sound Insulation Materials through Model Test (모의실험을 통한 완충재별 진동전달량과 동적특성과의 상관성 분석에 관한 연구)

  • Kim, Heung-Sik;Joo, Si-Woong;Jin, Pil-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1425-1431
    • /
    • 2006
  • In this study, An analysis of correlation between the vibration transmissions and the dynamic characteristics for floor impact sound insulation materials through model test was carried out. As the results, the correlation coefficients between the vibration transmissions and the dynamic characteristics for floor impact sound insulation materials were over 0.8 at the heavy and light floor impact source and less dynamic stiffness was more effective in reducing the vibration transmission.

  • PDF

Selection of the standard impact sounds similar to the human impact sounds in reinforced concrete floors (실충격음과 표준충격원으로 발생된 바닥충격음의 비교)

  • Sato, Shin-Ichi;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1167-1172
    • /
    • 2007
  • This study investigates human floor impact sounds; not only the children's jumping and running represented by heavy-weight impact source such as bang machine and impact ball but also the high-heel walking and the light weight object dropping represented by tapping machine in the standard measurements. However, due to reliability problems as a standard impactor, bang machine has not been included in the new draft of ISO 10140 Part 3: Measurement of impact sound insulation. Therefore, the procedure to convert the floor impact sound level of the bang machine into that of the impact ball has been demanded because the bang machine has been only the standard heavy-weight standard impact source and much of its data has been collected, This study indicates that the use of impact ball is reliable and that the bang machine data can be successfully converted into the impact ball data in case of box-frame type reinforced concrete structures.

  • PDF

Noise and Vibration Characteristics of Floor Impact in a Test Building (표준실험동에서의 소음.진동 특성)

  • Jeong, Young;Yoo, Seung-Yup;Lee, Pyoung-Jik;Jeong, Jeong-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.92-95
    • /
    • 2005
  • In this study, Heavy-weight floor impact sound and vibration in concrete structures with different slab thickness have been measured in a test building. It was found that natural frequency increased according to increases of slab thickness, and acceleration level decreases. Results also show that the measurements in the 210 and 240mm slab structures are complied with the result from finite element analysis but the In and 180mm slab structures are not because the structures are constrained to the ground. Therefore, in modelling process the condition of sub-structures should be examined in relation to the boundary conditions.

  • PDF

Comparison of Rating Methods for the Floor Impact Noise (바닥충격음 평가방법 중 단일수치평가량과 dB(A) 비교)

  • Park, Cheol-Yong;Jang, Dong-Woon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.612-615
    • /
    • 2006
  • In this study, we compared and analyzed the floor impact noise insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels(dB(A)). The results of this study are(1)dB(A) by the specified frequency is 0.5dB(A) at light weight and 2.5dB(A) at heavy weight upper than all pass dB(A)(2)the rating using reversed A-weighting curve is 5dB lower than dB(A)(3)the number of rating using reversed A-weighting curve mainly depends on impact noise pressure level of 63Hz in heavy weight but dB(A) does not.

  • PDF

A Working plan of classification against Floor Impact Sound (바닥충격음의 등급화 시공방안)

  • Jeong Gab-Cheol
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.170-173
    • /
    • 2004
  • The law about floor impact sound goes into effect from March 23th in 2004 and is applying to new designs. According to the new law, the minimal of slab thickness is 180mm by standard floor structure and the new law presents about the minimal standard about heavy-weight impact sound. Also, It presents about classification of light-weight sound separate the minimal standard, so demand of consumers can be accepted. But a working plan of classification about light-weight sound is not presented in accordance with field test, so the problem that design can't be achieved although the aim of design is formed. This study shows contents to investigate for working of classification and will be helpful to designers and construction corporations.

  • PDF

Application of Finite Element Method to Floor Impact Vibration Analysis in the Apartment Buildings (공동주택의 바닥 충격 진동 해석을 위한 유한요소법 응용)

  • Seo, Sang-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.387-390
    • /
    • 2005
  • Finite element method was applied to the vibration analysis of concrete slab system in apartment building. To save the time and cost the 2 dimensional finite element model was proposed. At first, experimental results show that sound peak components to influence the overall level and the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab. Second, there is linear relationship between the impact sound pressure level and vibration acceleration level. Third, 2 dimensional finite element model was enough to analyze the vibration analysis of floor structure system.

  • PDF

A Study on the Heavy Impact Sound Insulation Performance of Apartments depending on the Shape of Receiving Room (공동주택 수음실의 평면형태에 따른 중량충격음 특성 변화 연구)

  • Gi, No-Gab;Kim, Hang;Choi, Eun-Seok;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1317-1320
    • /
    • 2006
  • This study compared the floor impact sound level of rectangular receiving room type to differed receiving room types to analyze effect of room mode. The floor impact sound level of master room were higher than the level of living room which resulted from room mode. The result showed that the level of low frequency bandwidth in the location varied with receiving room types were lower than general measuring point of rectangular receiving room.

  • PDF

Evaluating the Vibrational Characteristics of Floor Impact Noise in Different Structural Elements of an Apartment House (바닥충격에 의한 공동주택의 바닥, 벽, 천장의 진동 및 소음방사특성 연구)

  • Lee, Byung-Kwon;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.480-485
    • /
    • 2002
  • The overall noise reduction was compared in regard to the vibrational characteristics of floor impact noise in a multi story residential building which has several noise reduction treatments. The vibration through its structural elements such as wall, floor and ceiling and sound emitting were investigated for each insulation treatment. It was found that, in case of heavy-weight impact noise, the vibration energy is emitted mostly from ceiling, but for the light-weight impact noise, most of the energy comes through ceiling and walls. That is, the vibration of a ceiling is the main factor that determines the frequency characteristics of the transmitting noise to lower floors.

  • PDF