• Title/Summary/Keyword: Heavy water

Search Result 2,665, Processing Time 0.049 seconds

Measures to improve water quality of Lake Euiam by controlling the incoming pollutants to the lake (의암호에 유입되는 오염물질 관리를 통한 호소 수질개선 방안)

  • Hwang, Hwan-Min;Yi, Geon-Ho;Kim, Mi-Yeon;Kim, Dong-Jin;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.783-790
    • /
    • 2011
  • The purpose of this study was to suggest the alternative measures to properly manage the water quality of Lake Euiam, Chuncheon. Current pollution level of Gongji stream (influent to Lake Euiam) and sources of contamination in Lake Euiam were investigated. Particle size, organic matter and nutrient contents, heavy metals were analyzed for sediment samples taken from lower region of Gongji stream. Average organic matter content of nine sediment samples was 5.7%, and for nitrogen and phosphorus it was 750 mg/kg and 977mg/kg, respectively. Heavy metals including aluminum, iron, manganese and zinc were measured, whereas Cd and As were not detected. Effluent from Chuncheon Wastewater Treatment Plant appeared to be one of the main cause of organic matter and nutrients level in Lake Euiam. Inhibition of primary production and consequent reduction of organic matter content within the Lake should be a key measure to protect the water quality of Lake Euiam. Preventive measures to reduce the level of nutrients in wastewater treatment effluent were found necessary.

Study of Effectiveness of using higher voltages in analysis of dredged sediments and heavy metal concentration (고전압 이용한 준설퇴적토 유효성 및 중금속 변화에 관한 연구)

  • Kwon, Ki-Bum;Kim, Sang-Keun;Ramchanda, Prasad;Yu, Jun;Chung, Ha-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1446-1451
    • /
    • 2008
  • The clay found in the river or in any waste water treatment plant usually have a very high content of water. A large amount of sediments hinder the navigation in river. In waste water treatment plant, there is requirement of settling the thick sludge. These problems are overcome by using rapid means of sedimentation and settling. This paper focus on how method of Electrokinetic sedimentation can be made faster. Sedimentation using Electrokinetic phenomenon has been discussed with varied voltage applied and effect and dose of coagulant in increasing the process. The experimental test has been carried out at water content that are generally present in the case of river and small canals carrying waste water. This paper also focus on different heavy metals concentration during the process and the power aspects of process. A series of experiment were done to support the proposed theory and how a bubble formation could hinder the purpose of experiment.

  • PDF

Studies on Characterization of Soil Pollution and Variations of Heavy Metal Contents after Water-Tailings Reaction from Yonghwa Mine (용화광산 일대의 토양오염 및 물-광미 반응에 의한 중금속 용출 특성 연구)

  • Kang, Han;Kim, Young-Hun;Jang, Yun-Deuk;Kim, Jeong-Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.85-93
    • /
    • 2013
  • This study is conducted to evaluate the leaching of contaminants from mine tailing by natural water and finally to estimate the leaching and transportation of heavy metal contaminants by rainfall. In order to identify contaminated heavy metal of soil, 17 soil, 2 tailing and 2 waste dump and 2 control samples were taken at mine area and analyzed total metal contents. The leaching experiments were conducted using distilled water. Cu, Pb, Zn was extracted from the reddish mine tailing in a short period time, especially the extraction rate of Cu (45.0%) was highest. The contaminants were leached from the yellowish mine tailing within an hour and the leaching rate of Cd (42.0%) and Zn (17.2%) were relatively high. The reddish soil from the waste dump showed leaching of Cu (5.1%), Pb (4.0%) and Zn (3.3%), however the leaching rate was low except Mi (14.2%). From the yellowish soil sampled from the dumping site, the leaching of Cu (8.2%) and Ni (9.7%) was high while the leaching of Zn (0.2%) were relatively low.

Performance Analysis of Mechanical Face Seal Used for Primary Heat Transport Pump in Heavy Water Reactor (중수로 냉각재 펌프용 미케니컬 페이스 실의 성능 해석)

  • Kim, Jeong-Hun;Kim, Dong-Wook;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.27 no.5
    • /
    • pp.240-248
    • /
    • 2011
  • Mechanical face seal installed in primary heat transport pump used for heavy water reactor prevents leakage of working fluid using thin working fluid film between primary seal ring and mating ring. If the leakage of working fluid exceeds the allowable volume, serious accident can be happened by the trouble of primary heat transport pump. The thinner fluid film exists between primary seal ring and mating ring, the less working fluid leaks out. On the other hand, if the thickness of fluid film is not enough, the life of mechanical face seal will be reduced by friction and wear. Therefore appropriate design is necessary to maximize the performance and life of mechanical face seal. In this study, numerical analysis using finite volume method was conducted to investigate the performance of mechanical face seals which have same deep straight groove and 11 different net coning values. As results, equilibrium clearance between primary seal ring and mating ring, leakage volume of working fluid, friction torque on sealing surface and stiffness of working fluid film were obtained. With increasing net coning value, equilibrium clearance and leakage volume increase, and friction torque and stiffness of fluid film decrease.

Geochemical Approaches for Investigation and Assessment of Heavy Metal Contamination in Abandoned Mine Sites (폐광산지역의 오염특성 조사와 평가를 위한 지구화학적 접근방법)

  • 이평구;조호영;염승준
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.35-48
    • /
    • 2004
  • This paper provides a comprehensive overview of geochemical approaches for investigating and assessing heavy metal contamination in abandoned mine sites. Major sources of contaminants at the abandoned mine sites are mine water, waste rocks, tailings, and chemicals used in beneficiation and mineral processing. Soil, sediment, surface and ground water, and ecological system can be contaminated by heavy metals, which are transported due to erosion of mine waste piles, discharge of acid mine drainage and processed water, and dispersion of dust from waste rocks and tailings. The abandoned mine sites should be characterized using various methods including chemical analysis, mineralogical analysis, acid generation prediction tests, leaching/extraction tests, and field tests. Potential and practical environmental impacts from the abandoned mines should be assessed based on the site characterization.

Removal of Diazinon and Heavy Metals in Water by Benthic Macroinvertebrate (저서성 대형무척추동물을 이용한 수중의 다이아지논 및 중금속 제거)

  • Lee, Hwa-Sung;Ryoo, Keon-Sang
    • Journal of Environmental Science International
    • /
    • v.21 no.1
    • /
    • pp.57-67
    • /
    • 2012
  • The midge samples were undertaken at three streams, representing different surrounding environments, to investigate the contaminant exposure of midge. The content of heavy metals in midge collected in Singil stream were generally higher as a result of input to the industrial effluents with respect to other streams. Adsorption experiments were done to evaluate the possibility of removing contaminants from water with midge. Diazinon and heavy metals were contaminant target compounds in this study. The removal rate of diazinon in water by midge was 60-75%. In the case of Cu, the removal rate was reached around 90% at the lower initial concentration of 1.87 and 0.81 ppm rather than 4.25 ppm. The reduction of concentration of Cr and Cd according to the lapse of time was similar to the Cu, but their removal rates were shown 50% and 60-74%, respectively. The removal rate of Zn by midge represented relatively high level within the experimental condition. No change in concentration of Cr and As with time were occurred at all experimental conditions. It accounts for the fact that the reduction of Cr and As could not be achieved through the adsorption process, using midge.

Semi-Rig, Anti-condensation design on steel surface in pontoon area (Semi-Rig, Pontoon 구역 표면 결로 예방 설계)

  • Seo, Dong-jae;Park, Sang-un;Noh, Joung-hwan;Shim, Hak-mu
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2017.10a
    • /
    • pp.105-108
    • /
    • 2017
  • Condensation is one of the common issues which we can easily see in everyday life. For example, the surface of glasses with cold water is easily moisturized. This wet surface gives us uncomfortable feeling and is sometimes dangerous because it is slippery. As the safety on working space is one of the most important issue on offshore project, condensation is also important matter to take care of with precaution. Since the bottom of vessel or offshore facility is submersed in the water, the risk of having condensate on the steel surface is getting higher because sea water temperature is normally lower than ambient temperature. And if there is any electric equipment or person working in that space, condensation is normally not allowed. The pontoon of semi-submersible drilling rig is such a space which is submersed, with electric and mechanical equipments and person working periodically. To prevent condensation in pontoon, study was conducted by checking several cases.

  • PDF

Preparation of Water Soluble Chitosan Blendmers and Their Application to Removal of Heavy Metal ions from Wastewater

  • Seo, Sang-Bong;Toshio Kajiuchi;Kim, Dae-In;Lee, Soon-Hong;Kim, Hak-Kil
    • Macromolecular Research
    • /
    • v.10 no.2
    • /
    • pp.103-107
    • /
    • 2002
  • High purity water soluble chitosans (WsCs) were employed as a flocculant to remove heavy metal ions from wastewater of industrial plating wastewater treatment complex. Their weight average molecular weights and polydispersities were 272,000~620,000 g/mol and 1.4~1.9 range, respectively and were readily soluble in water in the pH range of 3~11. Heavy metal ions such as chromium, iron and copper were removed well by WsCs. When WsCs was blended with either sodium N, N-diethyldithiocarbamate trihydrate (SDDC$_{T}$) or sodium salicylate (SSc), the removal efficiency was further increased primarily due to the excess amount of hydrophilic sulfonic and carboxylic groups. Especially, in the case of WsCs-SSc the remaining chromium and copper concentrations were 0.1 mg/L and 9.5 mg/L, which are 1/15 and 1/3 compared with that of pure WsCs, respectively. The former is within the acceptable limit, but the latter is not. Therefore, the effective copper flocculant remains to be studied.d.

Critical Design Issues on the Cathodic Protection Systems of Ships

  • Lee, Ho Il;Lee, Chul Hwan;Jung, Mong Kyu;Baek, Kwang Ki
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.90-95
    • /
    • 2007
  • Cathodic protection technology has been widely used on ship's outer hull and inner side of ballast water tanks as a supplementary corrosion protection measure in combination with protective organic coatings. Impressed current cathodic protection system is typically opted for the ship's hull and, sacrificial anode system, for ballast water tanks. The anticipation and interest in cathodic protection system for ships has been surprisingly low-eyed to date in comparison with protective coatings. Computational analysis for the verification of cathodic protection design has been tried sometimes for offshore marine structures, however, in commercial shipbuilding section, decades old design practice is still applied, and no systematic or analytical verification work has been done for that. In this respect, over-rotection from un-erified initial design protocol has been also concerned by several experts. Especially, it was frequently reported in sacrificial anode system that even after full design life time, anode was remaining nearly intact. Another issue for impressed current system, for example, is that the anode shield area design for ship's outer hull should be compromised with actual application situation, because the state-of-the-art design equation is quite impractical from the applicator's stand. Besides that, in this study, some other critical design issues for sacrificial anode and impressed current cathodic protection system were discussed.

The Effect of Aerated Concrete containing Foam Glass Aggregate on the Floor Impact Sound Insulation (발포유리 혼합기포 콘크리트의 바닥충격음 차단성능 영향에 관한 연구)

  • Yun, Chang-Yeon;Jeong, Jeong-Ho;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.414-422
    • /
    • 2013
  • As structure-borne sound, the floor impact sound is one of the serious noises in residential building. Most of heating system applied to the typical Korean residential building is floor heating system which is called ondol. The ondol usually consists of finishing material, mortar with heating coil, light-weight aerated concrete and reinforced concrete. This study focused on the isolation of heavy-weight impact sound and modification of mortar and light-weight aerated concrete. Specifically the glass foam aggregate was added on light-weight aerated concrete. Also, water-cement ratio and amount of cement on mortar were revised. The sound pressure level of heavy-weight impact was measured in reverberation chamber using both bang-machine and impact ball. The size of specimen was 1 m by 1 m. Substitution ratio of glass foam aggregate on light-weight aerated concrete shows relationship with heavy-weight impact sound pressure level. In addition, heavy-weight impact sound pressure level was decreased with increment of water-cement ratio and amount of cement on mortar.