• Title/Summary/Keyword: Heavy Equipment

Search Result 493, Processing Time 0.023 seconds

Development of AAS and Determination of metals in airborne particles (원자흡수분광광도계의 제작 및 분진 중 금속성분 분석 비교)

  • Choi, Bae-Jin;Bang, Myung-Sik;Yeo, In-Hyeong
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.226-231
    • /
    • 2003
  • We analyzed the concentrations of heavy metals associated airbone particles by using AAS made by both a domestic manufacturer and one of the foreign manufacturer. One model developed by a domestic manufacture showed excellent results in the selected wavelength with an excellent performance of a monochromator. It abandons a big drop except a fine drop to improve reproduction in atomizer, so that no remains should leave. Using the low pass filter we were able to reduce a noise of detection signal. The performance of our equipment was found to be highly compatible with that of a foreign company as we achieved the detection limit of about $0.015{\mu}g/L$ using a standard solution of Au. The PM samples had been collected from by main observation points in 7 areas of Seoul city from 2001 to the spring in 2002. with these PM sample we analyzed the concentrations of Pb, Cu, Mn, Cd, Ni, Fe, Cr, Co, Mg and Al.

Thermal-hydraulic Analysis of Operator Action Time on Coping Strategy of LUHS Event for OPR1000 (OPR1000형 원전의 최종열제거원 상실사고 대처전략 및 운전원 조치 시간에 따른 열수력 거동 분석)

  • Song, Jun Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.121-127
    • /
    • 2020
  • Since the Fukushima nuclear accident in 2011, the public were concerned about the safety of Nuclear Power Plants (NPPs) in extreme natural disaster situations, such as earthquakes, flooding, heavy rain and tsunami, have been increasing around the world. Accordingly, the Stress Test was conducted in Europe, Japan, Russia, and other countries by reassessing the safety and response capabilities of NPPs in extreme natural disaster situations that exceed the design basis. The extreme natural disaster can put the NPPs in beyond-design-basis conditions such as the loss of the power system and the ultimate heat sink. The behaviors and capabilities of NPPs with losing their essential safety functions should be measured to find and supplement weak areas in hardware, procedures and coping strategies. The Loss of Ultimate Heat Sink (LUHS) accident assumes impairment of the essential service water system accompanying the failure of the component cooling water system. In such conditions, residual heat removal and cooling of safety-relevant components are not possible for a long period of time. It is therefore very important to establish coping strategies considering all available equipment to mitigate the consequence of the LUHS accident and keep the NPPs safe. In this study, thermal hydraulic behavior of the LUHS event was analyzed using RELAP5/Mod3.3 code. We also performed the sensitivity analysis to identify the effects of the operator recovery actions and operation strategy for charging pumps on the results of the LUHS accident.

Needle Stick Injuries and their Related Safety Measures among Nurses in a University Hospital, Shiraz, Iran

  • Jahangiri, Mehdi;Rostamabadi, Akbar;Hoboubi, Naser;Tadayon, Neda;Soleimani, Ali
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.72-77
    • /
    • 2016
  • Background: This study aimed to determine the prevalence and factors related to needle stick injuries (NSIs) and to assess related safety measures among a sample of Iranian nurses. Methods: In this cross-sectional study, a random sample of 168 registered active nurses was selected from different wards of one of the hospitals of Shiraz University of Medical Sciences (SUMS). Data were collected by an anonymous questionnaire and a checklist based observational method among the 168 registered active nurses. Results: The prevalence of NSIs in the total of work experience and the last year was 76% and 54%, respectively. Hollow-bore needles were the most common devices involved in the injuries (85.5%). The majority of NSIs occurred in the morning shift (57.8%) and the most common activity leading to NSIs was recapping needles (41.4%). The rate of underreporting NSIs was 60.2% and the major reasons for not reporting the NSIs were heavy clinical schedule (46.7%) and perception of low risk of infection (37.7%). A statistically significant relationship was found between the occurrence of NSIs and sex, hours worked/week, and frequency of shifts/month. Conclusion: The study showed a high prevalence of NSIs among nurses. Supportive measures such as improving injection practices, modification of working schedule, planning training programs targeted at using personal protective equipment, and providing an adequate number of safety facilities such as puncture resistant disposal containers and engineered safe devices are essential for the effective prevention of NSI incidents among the studied nurses.

Using Shoulder Straps Decreases Heart Rate Variability and Salivary Cortisol Concentration in Swedish Ambulance Personnel

  • Karlsson, Kare J.;Niemela, Patrik H.;Jonsson, Anders R.;Tornhage, Carl-Johan A.
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.32-37
    • /
    • 2016
  • Background: Previous research has shown that paramedics are exposed to risks in the form of injuries to the musculoskeletal system. In addition, there are studies showing that they are also at increased risk of cardiovascular disease, cancer, and psychiatric diseases, which can partly be explained by their constant exposure to stress. The aim of this study is to evaluate whether the use of shoulder straps decreases physical effort in the form of decreased heart rate and cortisol concentration. Methods: A stretcher with a dummy was carried by 20 participants for 400 m on two occasions, one with and one without the shoulder straps. Heart rate was monitored continuously and cortisol samples were taken at intervals of 0 minutes, 15 minutes, 30 minutes, 45 minutes, and 60 minutes. Each participant was her or his own control. Results: A significant decrease in heart rate and cortisol concentration was seen when shoulder straps were used. The median values for men (with shoulder straps) at 0 minutes was 78 bpm/21.1 nmol/L (heart rate/cortisol concentration), at 15 minutes was 85 bpm/16.9 nmol/L, and at 60 minutes was 76 bpm/15.7 nmol/L; for men without shoulder straps, these values were 78 bpm/21.9 nmol/L, 93 bpm/21.9 nmol/L, and 73 bpm/20.5 nmol/L. For women, the values were 85 bpm/23.3 nmol/L, 92 bpm/20.8 nmol/L, and 70 bpm/18.4 nmol/L and 84 bpm/32.4 nmol/L, 100 bpm/32.5 nmol/L, and 75 bpm/25.2 nmol/L, respectively. Conclusion: The use of shoulder straps decreases measurable physical stress and should therefore be implemented when heavy equipment or a stretcher needs to be carried. An easy way to ensure that staff use these or similar lifting aids is to provide them with personalized, well-adapted shoulder straps. Another better option would be to routinely sewn these straps into the staff's personal alarm jackets so they are always in place and ready to be used.

Fuzzy and Proportional Controls for Driving Control of Forklift AGV (퍼지와 비례 제어를 이용한 지게차 AGV의 주행제어)

  • Kim, Jung-Min;Park, Jung-Je;Jeon, Tae-Ryong;Kim, Sung-Shin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.5
    • /
    • pp.699-705
    • /
    • 2009
  • This paper is represented to research of driving control for the forklift AGV. The related works that were studied about AGV as heavy equipment used two methods which are magnet-gyro and wire guidance for localization. However, they have weaknesses that are high cost, difficult maintenance according to change of environment. In this paper, we develop localization system through sensor fusion with laser navigation system and encoder, gyro for robustness. Also we design driving controller using fuzzy and proportional control. It considers distance and angle difference between forklift AGV and pallet for engaging work. To analyze performance of the proposed control system, we experiment in same working condition over 10 times. In the results, the average error was presented with 54.16mm between simulation of control navigation and real control navigation. Consequently, experimental result shows that the performance of proposed control system is effective.

Effect of Mobile Crane Load on Excavated Slope Stability (이동식 크레인 하중이 굴착사면 안정성에 미치는 영향 분석)

  • Kim, Jeong Kon;Na, Ye Ji;Won, Jeong-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.5
    • /
    • pp.18-26
    • /
    • 2021
  • The effect of heavy construction equipment on the excavated slope is investigated by slope stability analysis. A mobile crane with 500 kN capacity is applied as a working load to the background surface of the excavated slope, in both sandy soil and clay, designed to guarantee the safety of slope stability. Major parameters such as the distance between the edge of the slope and the mobile crane, groundwater level, and ground plate size of the mobile crane are considered. Only 23.8% and 14.3% of the analysis models with sandy soil and clay excavated slope, respectively, satisfied the slope stability. By changing the slope of the sandy soil from 1:1.0 to 1:1.2, the number of analysis models securing slope stability increased from 23.8% to 40.5%. For the clay excavated slope, the analysis models securing slope stability increased from 14.3% to 42.9% by changing slope inclination from 1:0.8 to 1:1.2. In addition, it is found that the increase in the size of the ground plate of the mobile crane increases the analysis models that secure slope stability. Therefore, it is an effective way to relax the excavated slope's inclination angle and simultaneously increase the ground plate size to guarantee stability.

Resistance and Structural Safety of a 3M Carbon Fibier-based Kayak (3미터급 카본 카약의 저항성능 및 구조 안전성 연구)

  • Seo, Kwang-Cheol;Lee, Gyeong-Woo;Park, Joo-Shin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.482-488
    • /
    • 2019
  • Leisure and business facilities have been steadily developing in Korea. Among waterborne leisure vessels and equipment, the distribution and sale of kayaks and canoes have significantly increased. Previously, (FRP) materials were primarily employed for constructing kayaks. However, owing to global warming and depletion of natural resources, the demand for non-polluting renewable energy is rapidly increasing, which has increased the demand for carbon fibers. To meet the requirements of changing social consciousness, a carbon fiber-based commercial kayak was designed in this study. Resistance analysis and structural safety were conducted by employing software tool for verifying the reliability of the proposed kayak. The pressure resistance and frictional resistance were examined in a wide range of speed. Obtained results indicate that at speeds greater than 2.6 m/s, the pressure resistance significantly increases and the total resistance also increases. Furthermore, the results corroborate that the proposed kayak structure has a adequate safety with respect to the design loads that are considered during operating conditions.

Estimation of Residual Strength for an Aged Floating Dock (노후화된 플로팅도크의 잔류 구조강도 평가)

  • Seo, Kwang-Cheol;Hong, Taeho;Park, Joo-Shin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.1
    • /
    • pp.122-129
    • /
    • 2019
  • Due to its nature the manufacturing industry faces a cyclical economy, and therefore there is an urgent need for a companion industry to cope with this cyclic pattern in the long run. The sector suitable for meeting this demand is the repair and shipbuilding industry. In order to operate a shipbuilding repair business, a floating dock is indispensable, and most obsolete floating docks were imported from overseas and operated through repair/maintenance. However, there is no precise guideline for floating dock safety, and most models have been in use for at least 30 years without being required to enter classification at the time of operation. In this study, structural strength analysis was carried out using measured thickness information of aged floating docks, and the residual structural strength of floating docks in operation was analyzed. The main results derived from this study can be referred to as guidelines for the review of the structural safety of similar equipment, and it is expected that an optimal solution will be found within a short time using this method for repair/maintenance.

Development of the Engineered Filter Media for Reducing Pollutants in Urban Runoff (도시지역 불투수면의 오염물질 유출저감을 위한 여재 개발 및 처리 특성 평가)

  • Kang, Sung Won;Lee, Jai Young;Kim, Seog Ku
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.391-396
    • /
    • 2011
  • Recently it revealed that urban runoff was one of the major source that contaminates the river, lake and estuary because it contains toxic compounds such as heavy metals and Poly Aromatic Hydrocarbons (PAHs) as well as suspended solids, organic compounds and nutrients. The engineered polymetric media in this research were developed for reducing pollutants in urban runoff and would be used to be charged in the storm water treatment equipment. The engineered media that were composed of the polypropylene was foamed to have the buoyancy and then shattered by mechanical for the efficient filtration. In this study, Spherical Expanded Polypropylene Media (SEPM), Crushed Polypropylene Media (CPM), Large Crushed Expanded Polypropylene Media (LCEPM), Small Crushed Expanded Polypropylene Media (SCEPM) were made from polypropylene. Surface characteristics of the developed media were determined by scanning electron microscopy analyses. Also, removal efficiencies of SS, $COD_{Cr}$ in the artificial road runoff and the bed headloss by media and particle pollutants captured by media were examined. Results on the surface characteristics of media indicated that SCEPM had the largest specific surface area, $0.80m^2/g$, the lowest specific gravity, 0.091, and the biggest porosity, 0.63, because of crushing the media at the process of manufacturing. And the SCEPM's removal efficiencies of TSS and $COD_{Cr}$ in the artificial road runoff were 92.9% and 83.6%, respectively and the headloss of SCEPM was the least of them.

Case Study on Location of Possible Tension Crack in Rock Slope (암반 비탈면의 인장균열 위치 선정에 관한 사례 연구)

  • Jeon, Byung-Gon;Kim, Jiseong;Kang, Gichun
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.3
    • /
    • pp.5-17
    • /
    • 2021
  • This study aims to investigate the causes and countermeasures for the occurrence of tension cracks in the slope of the rock mass of heavy equipment for road construction. Electric resistivity survey was performed to investigate the expandable tensile crack range. As a result of examining the distribution of soft zones in the rock mass, a low specific resistance zone was found at the bottom of the access road where tensile cracks occurred. It was confirmed that a low resistivity zone was distributed near the top of the excavation slope. Therefore, reinforcements was performed by determining the location of the possible tensile crack as the top of the excavation slope. Two rows of reinforced piles and anchors were proposed as a reinforcement method, and the slope stability analysis showed that the allowable safety factor was satisfied after reinforcements.