• Title/Summary/Keyword: Heating speed

Search Result 449, Processing Time 0.028 seconds

Temporal Variations of Stratification-Destratification in the Deukryang Bay, Korea (하계 득량만의 연직성층해양의 시간적 변동 특성)

  • 이병걸;조규대
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.139-150
    • /
    • 1995
  • The Quantitative estimations of the stratification - destratification(SD) phenomena in Deukryang Bay, Korea have been carried out based on the data of wind speed, heat flux through the sea surface and tidal current amplitude. To find out the main factors causing SD, wv introduce the rate of energy balance of the surface heat flux, tidal and wind stirring proposed by Simpson and Hunter(1974). The calculated potential energy of three terms are compared, from which the energy of wind stirring effect was one order smaller than the heat flux and the tidal stirring. Using the results, we complement time integration of the potential energy with the several s values of 0.010~0.014 at interval 0.001 and with wind speeds of 1.5 and 2.0 times larger than observation values at land. It shows that the variation of SD phenomena in the bay mainly depended on tidal stirring and sea surface heating in summer if there is no exceptionally strong wind event like Typhoon. The stratification become to be foamed from about 5 July although the stratification a little decreases during the second spring tidal period of middle of July.

  • PDF

Preparation of $LaAlO_3$ thin Films by Sol-gel Method (Sol-gel 방법에 의한 $LaAlO_3$ 박막의 제조)

  • Kim, H.J.;Kim, B.J.;Lee, H.G.;Hong, G.W.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.85-90
    • /
    • 2007
  • Lanthanum aluminate($LaAlO_3$) film has been prepared on single crystal and metal substrates by dip coating method. Lanthanum acetate and aluminum were prepared via ligand exchange starting from lanthanum nitrate hexahydrate and aluminum nitrate hexahydrate in acetate glacial acetic acid solution after being refluxed. Coating solution was obtained by diluting the gel with methanol and 2-methoxyethanol to adjust the total cation concentration to 0.67 M. Precursor coated film was prepared by dip-coating with a speed of 25 mm/min on various substrates such as $LaAlO_3$ (001), MgO(001), $SrTiO_3$(001) single crystal, LMO/MgO/Ni-alloy. Thin films have been obtained by heat treating the precursor film at various temperatures from $600^{\circ}C{\sim}900^{\circ}C$ and various heating rate from $0.83^{\circ}C/min{\sim}1.25^{\circ}C/min$ under $Ar/O_2$ mixture containing 1000ppm oxygen. The films have been characterized by scanning electronic microscopy (SEM) and X-ray diffraction (XRD). XRD analysis for the prepared film showed that $LaAlO_3$ thin films with a preferred orientation of (100) plane parallel to substrate surface were obtained at $800^{\circ}C(1.11\;^{\circ}C/min)$ on LMO/MgO/Ni-alloy substrate, but the intensity decreased with the increase of heat treatment temperature.

  • PDF

A Study on the Knocking Characteristics with Various Excess Air Ratio in a HCNG Engine (HCNG 엔진의 공기과잉율 변화에 따른 노킹 특성에 관한 연구)

  • Lim, Gihun;Park, Cheolwoong;Lee, Sungwon;Choi, Young;Kim, Changgi;Lee, Janghee
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.1
    • /
    • pp.7-12
    • /
    • 2013
  • As emission regulation for vehicle has been reinforced, many researches carried out for HCNG(hydrogen-natural gas blends) fuel to the conventional compressed natural gas (CNG) engine. However, abnormal combustion such as backfire, pre-ignition or knocking can be caused due to high combustion speed of hydrogen and it can result in over heating of engine or reduction of thermal efficiency and power output. In the present study, improvement of combustion performance was observed with HCNG fuel since it can extend a flammability limit. Knocking characteristics for CNG and HCNG fuel were investigated. Feasibility of HCNG fuel was evaluated by checking the knock margin according to excess air ratio. The operation of engine with HCNG was stable at minimum advance for best torque(MBT) spark timing and knock phenomena were not detected. However, it is necessary to prepare higher knock tendency since possibility of knock is higher with HCNG fuel.

A Case Study on the Air Quality Impact Assessment for the Large Scale Urban Development (대규모 도시개발사업에 대한 대기질 평가 사례 연구)

  • Kim, Sang-Mok;Lee, Sang-Hun;Park, Keun-Hyoung;Woo, Jae-Kyun;Koo, Youn-Seo;Kim, Sung-Tae;Han, Jin-Seok
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.381-391
    • /
    • 2007
  • The air quality modeling was carried out to assess the impact of air quality for large scale urban development. The site for the assessment is Multi-fuctional Administrative City which locates in Yeongi-gun, Chungcheongnam-do and estimated population in 2030 is 500,000. Two automatic weather monitoring stations were installed to monitor the meteorological variables for a year and upper air meteorological parameters were measured using radiosonde for 5 days with 4 hours interval in every season. The air quality of standard air pollutants were also measured for 5 days continuously in every season. The results of wind field analysis based on the site measurements and CALMET modeling showed that the valley and mountain winds were prevailed when the sypnotic wind was weak. It also showed that wind speed and directions were highly space-variable within the site basin. The variable wind characteristics implies that the Gaussian dispersion model such ISC3 and AERMOD are not appropriate and the unsteady-sate Lagrangian model such as CALPUFF is preferable. CALPUFF model was applied to assess air quality impact of new sources. The new sources were those for individual and group heating facilities as well as the traffic increases. The results showed that the estimated concentrations of CO and $SO_2$ pollutants by summing the impact concentration of new sources by the dispersion model and the ambient air concentrations by the site measurements were acceptable but those of PM-10 and $NO_2$ would violate ambient air quality standards at several locations due to high ambient air concentrations. It is recommended that the emission reductions near the site should be enforced to improve the ambient air quality.

Heat Transfer in Rotating Duct with $70^{\circ}$ Angled Ribs (회전하는 덕트내 설치된 $70^{\circ}$ 경사요철의 열전달 특성)

  • Choi, Chung;Lee, Sei Young;Won, Jung Ho;Cho, Hyung Hee;Park, Byung kyu
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.3 s.12
    • /
    • pp.7-13
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics inside a cooling passage of rotating gas-turbine blades. The rotating duct has staggered ribs with $70^{\circ}$ attack angle, which are attached on leading and trailing surfaces. Naphthalene sublimation technique is employed to determine detailed local heat transfer coefficients using the heat and mass transfer analogy. Additional numerical calculations are conducted to analyze the flow patterns in the cooling passage. The present experiments employ two-surface heating conditions in the rotating duct because the exposed surfaces to hot gas stream are pressure and suction side surfaces in the middle passages of an actual gas-turbine blade. Secondary flows are generated by Coriolis and centrifugal forces in the spanwise and streamwise directions. The ribs attached on the walls disturb the mainflow resulting in recirculation and secondary flows near the ribbed wall. The local heat transfer and flow patterns in the passage are changed significantly according to rib configurations and duct rotation speeds. Therefore, the geometry and arrangement of the ribs are important for the advantageous cooling performance. The experimental results show that the ribs enhance the heat transfer more than $70\%$ from that of the smooth duct. The duct rotation generates the heat transfer discrepancy between the leading and trailing walls due to the secondary flows induced by the Coriolis force. The overal heat transfer pattern on the leading and trailing walls for the first and second passes are depended on the rotating speed, but the local heat transfer trend is affected mainly by the rib arrangements.

  • PDF

Study on the characteristics During Saturated Pool Nucleate Boiling of Refrigennt Binary Mixtures (냉매 이성분 혼합물의 포화 풀핵비등 특성에 관한 연구)

  • Kim Jeong Bae;Lee Han Choon;Kim Moo Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.643-652
    • /
    • 2005
  • Saturated nucleate pool boiling experiments for binary mixtures, which are consisted of refrigerant R11 and R113, were performed with constant wall temperature condition. Results for binary mixtures were also compared with pure fluids. A microscale heater array and Wheatstone bridge circuits were used to maintain the constant temperature of the heating surface and to obtain heat flow rate measurements with high temporal and spatial resolutions. Bubble growth images were captured using a high speed CCD camera synchronized with the heat flow rate measurements. The departure time for binary mixtures was longer than that for pure fluids, and binary mixtures had a higher onset of nucleate boiling (ONB) temperature than pure fluids. In the asymptotic growth region, the bubble growth rate was proportional to a value between $t^{\frac{1}{6}}$ and $t^{\frac{1}{4}}$. The bubble growth behavior was analyzed to permit comparisons with binary mixtures and pure fluids at the same scale using dimensionless parameters. There was no discernable difference in the bubble growth behavior between binary mixtures and pure fluids for a given ONB temperature. And the departure radius and time were well predicted within a ${\pm}30{\%}$ error. The minimum heat transfer coefficient of binary mixtures occurred near the maximum ${\mid}y-x{\mid}$ value, and the average required heat flux during bubble growth did not depend on the mass fraction of R11 as more volatile component in binary mixtures. Finally, the results showed that for binary mixtures, a higher ONB temperature had the greatest effect on reducing the heat transfer coefficient.

A Study on the Improvement of Plastic Boat Manufacturing Process Using TOC & Statistical Analysis (TOC와 통계적 분석에 의한 플라스틱보트 제조공정 개선에 관한 연구)

  • Yoon, Gun-Gu;Kim, Tae-Gu;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.130-139
    • /
    • 2016
  • The purpose of this paper is to analyze the problems and the sources of defective products and draw improvement plans in a small plastic boat manufacturing process using TOC (Theory Of Constraints) and statistical analysis. TOC is a methodology to present a scheme for optimization of production process by finding the CCR (Capacity Constraints Resource) in the organization or the all production process through the concentration improvement activity. In this paper, we found and reformed constraints and bottlenecks in plastic boat manufacturing process in the target company for less defect ratio and production cost by applying DBR (Drum, Buffer, Rope) scheduling. And we set the threshold values for the critical process variables using statistical analysis. The result can be summarized as follows. First, CCRs in inventory control, material mix, and oven setting were found and solutions were suggested by applying DBR method. Second, the logical thinking process was utilized to find core conflict factors and draw solutions. Third, to specify the solution plan, experiment data were statistically analyzed. Data were collected from the daily journal addressing the details of 96 products such as temperature, humidity, duration and temperature of heating process, rotation speed, duration time of cooling, and the temperature of removal process. Basic statistics and logistic regression analysis were conducted with the defection as the dependent variable. Finally, critical values for major processes were proposed based on the analysis. This paper has a practical importance in contribution to the quality level of the target company through theoretical approach, TOC, and statistical analysis. However, limited number of data might depreciate the significance of the analysis and therefore it will be interesting further research direction to specify the significant manufacturing conditions across different products and processes.

Microwave assisted processing of silver thick films for microelectronic applications

  • Rane, Sunit;Bhatkar, Rushna;Mulik, Uttam;Amalnerkar, Dinesh
    • Advances in materials Research
    • /
    • v.2 no.3
    • /
    • pp.133-140
    • /
    • 2013
  • This paper aims to focus on the microwave processing of thick films which is a fast, cheap technique and could be the alternative to the currently used conventional high temperature processing technique. Microwave processing has gained worldwide acceptance as a novel method for heating and sintering a variety of materials, as it offers specific advantages in terms of speed, energy efficiency, process simplicity, finer microstructures and lower environmental hazards. Silver conducting thick films were prepared and processed in the household microwave oven. The films sintered at different time period by keeping the other parameter such as microwave power, film thickness etc constant. The microstructure analysis revealed that the surface morphology of the microwave processed films become compact with respect to the processing time. The sheet resistance for microwave sintered silver films is in the range of 0.003 to $1.207{\Omega}/{\Box}$ where as the films fired at 750 and $850^{\circ}C$ showed the resistance of 0.009 and $0.003{\Omega}/{\Box}$ which can be comparable. The results revealed that the microstructure of the microwave sintered films has more uniform and compact surface than that of the conventionally fired films. The paper reports upon the preparation of silver thick film by screen printing technique and processing the same by microwave which also compared with the conventionally processed thick films.

A Study on Effect of Intake Mixture Temperature upon Fuel Economy and Exhaust Emissions in Diesel Engines with a Scrubber EGR System

  • Bae, Myung--Whan;Ryu, Chang-Seong;Yoshihiro Mochimaru;Jeon, Hyo-Joong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.315-331
    • /
    • 2004
  • The effects of intake mixture temperature on performance and exhaust emissions under four kinds of engine loads were experimentally investigated by using a four-cycle. four-cylinder. swirl chamber type. water-cooled diesel engine with scrubber EGR system operating at three kinds of engine speeds. The purpose of this study is to develop the scrubber exhaust gas Recirculation (EGR) control system for reducing $\textrm{NO}_{x}$ and soot emissions simultaneously in diesel engines. The EGR system is used to reduce $\textrm{NO}_{x}$ emissions. And a novel diesel soot-removal device of cylinder-type scrubber with five water injection nozzles is specially designed and manufactured to reduce soot contents in the recirculated exhaust gas to the intake system of the engine. The influences of cooled EGR and water injection. however. would be included within those of scrubber EGR system. In order to survey the effects of cooled EGR and moisture on $\textrm{NO}_{x}$ and soot emissions. the intake mixtures of fresh air and recirculated exhaust gas are heated up using a heater with five heating coils equipped in a steel drum. It is found that intake and exhaust oxygen concentrations are decreased, especially at higher loads. as EGR rate and intake mixture temperature are increased at the same conditions of engine speed and load. and that $\textrm{NO}_{x}$ emissions are decreased. while soot emissions are increased owing to the decrease in intake and exhaust oxygen concentrations and the increase in equivalence ratio. Thus ond can conclude that $\textrm{NO}_{x}$ and soot emissions are considerably influenced by the cooled EGR.

A Study on Winter Season Measurement Results to cope with Dynamic Pricing for the VRF System

  • Kim, Hwan-yong;Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • v.17 no.3
    • /
    • pp.109-115
    • /
    • 2015
  • The dynamic pricing of electricity, where the electricity rate increases in a time zone with a high demand for electricity is typically applied to a building whose power reception capacity is greater than a certain size. This includes the time of use(TOU) electricity pricing in Korea which can induce the effect of reducing the power demand of a building. Meanwhile, a VRF (Variable Refrigerant Flow) system that uses electricity is regarded as one of the typical heating and cooling systems along with central air conditioning (central HVAC) for its easy operation and application to the building. Thus, to reduce power energy and operating costs of a building in which the TOU and VRF systems are applied simultaneously, we suggested a control for changing the indoor temperature setting within the thermal comfort range or limiting the rotational speed of an inverter compressor. In this study, to describe the features of the above-mentioned control and verify its effects, we evaluated the results obtained from the analysis of its operation data. Through the actual measurements in winter operations for 73 days since mid- December 2014, we confirmed a reduction of 10.9% in power energy consumption and 12.2% in operating costs by the new control. Also, a reduction of 13.3% in power energy consumption was identified through a regression analysis.