• 제목/요약/키워드: Heating source

검색결과 901건 처리시간 0.024초

밀폐공간내 화재에 의해 생성된 연소가스 분석 및 유동에 관한 연구 (A study on the Analysis of Combustion Gas and its Flow Induced by Fire in an Enclosure)

  • 추병길;조성곤
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.77-93
    • /
    • 1997
  • The natural convection and combined heat transfer induced by fire in a rectangular enclosure is numerically studied. The model for this numerical analysis is partially opened, it is divided by a vertical baffle projecting from ceiling. The solution procedure Includes the standard k- $\varepsilon$ model for turbulent flow and the discrete ordinates method (DOM ) is used for the calculation of radiative heat transfer equation. In this study, numerical simulation on the combined naturnal convection and radiation is carried out in a partial enclosure filled with absorbed-emitted gray media, but is not considered scattering problem. The velocity vectors, streamlines, and isothermal lines are compared the results of pure convection with those of the combined convection-radiation, the combined heat transfer. Comparing the results of pure convection with those of the combined convection-radiation, the combined heat transfer analysis shows the stronger circulation than those of the pure convection. Three different locations of heat source are considered to observe the effect of heat source location on the heat transfer phenomena. As the results, the circulation and the heat transfer In the left region from heating block are much more influenced than those in the right region. It is also founded that the radiation effect cannot be neglected in analyzing the building in fire.

  • PDF

밀폐된 원통형 분무 연소기내의 자연발화 현상에 관한 수치적 연구 (A Numerical Study of Autoignition in a Confined Cylindrical Spray Combustor)

  • 최지훈;백승욱
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.778-787
    • /
    • 1999
  • In this study, the autoignition process of liquid fuel, injected into hot and stagnant air in a 2-D axisymmetric confined cylindrical combustor, has been investigated. Eulerian-Lagrangian scheme was adopted to analyze the two-phase flow and combustion. The unsteady conservation equations were used to solve the transition of the gas field. Interactions between two phases were accounted by using the particle source in cell (PSI-Cell) model, which was used for detailed consideration of the finite rates of transports between phases. And infinite conduction model was adopted for the vaporization of droplets. The results have shown that the process of the autoignition consists of heating up of droplets, vaporization, mixing and ignition. The ignition criteria could be determined by the temporal variations of temperature, reaction rate and species mass fraction. And the effects of various parameters on ignition phenomena are examined. These have shown that the increasing the reaction rate and/or the vaporization rate can reduce the ignition delay time.

레이저 보조선삭 중 주철환봉 내부의 온도분포 예측에 관한 연구 (A study for prediction of temperature distribution in laser-assisted turning for rod-shaped cast iron)

  • 김관우;조해용;이제훈;서정;신동식
    • 한국레이저가공학회지
    • /
    • 제13권2호
    • /
    • pp.10-16
    • /
    • 2010
  • Laser-assisted machining is dependent on absorbed energy density into workpiece. Generally, the absorptivity of laser beam is dependent on wave length of laser, materials, surface roughness, etc. Various shapes and energy densities for beam irradiation can be used to laser-assisted machining. In this thesis, efficient method of heat source modeling was developed and designed by using one fundamental experimental trials. And then, laser-assisted machining of rod-shaped cast iron was simulated by using commercial FEM code MARC. Simulations and experiments with various conditions were carried out to determine suitable condition of pre-heating for laser-assisted turning process. Temperature distribution of cutting zone could be predicted by simulation.

  • PDF

탄소강 환봉의 레이저 표면변태경화 특성에 관한 연구 (I) - 가우시안 파워밀도 분포의 레이저 열원을 이용한 표면변태경화 특성 - (Study on Characteristics of Laser Surface Transformation Hardening for Rod-shaped Carbon Steel (I) - Characteristics of Surface Transformation Hardening by Laser Heat Source with Gaussian Intensify distribution -)

  • 김종도;강운주
    • Journal of Welding and Joining
    • /
    • 제25권3호
    • /
    • pp.78-84
    • /
    • 2007
  • Laser Material Processing has been replaced the conventional machining systems - cutting, drilling, welding and surface modification and so on. Especially, LTH(Laser Transformation Hardening) process is one branch of the laser surface modification process. Conventionally, some techniques like a gas carburizing and nitriding as well as induction and torch heating have been used to harden the carbon steels. But these methods not only request post-machining resulted from a deformation but also have complex processing procedures. Besides, LTH process has some merits as : 1. It is easy to control the case depth because of output(laser power) adjustability. 2. It is able to harden the localized and complicated a.ea and minimize a deformation due to a unique property of a localized heat source. 3. An additional cooling medium is not required due to self quenching. 4. A prominent hardening results can be obtained. This study is related to the surface hardening of the rod-shaped carbon steel applied to the lathe based complex processing mechanism, a basic behavior of surface hardening, hardness distribution and structural characteristics in the hardened zone.

용접이상화에 의한 용접부정의 예측과 정도 (Prediction of Welding Imperfection with Idealization of Welding and Their Accuracy)

  • 이재익;장경호;김유철
    • Journal of Welding and Joining
    • /
    • 제31권5호
    • /
    • pp.15-19
    • /
    • 2013
  • In order to reduce a grand compute time in prediction of welding distortion and residual stress by 3D thermal elastic plastic analysis, idealization of welding that is methods to heat input simultaneously in all weld metal on the same welding direction is carried out on two weld joints(butt welding and fillet welding). Then, the accuracy of acquired results is investigated through the comparison of the high accuracy prediction results. The thermal conduction analysis results by idealization of welding, the temperature is raised accompany with beginning of heat input because all of weld metal is heated input at the same time. On the other side, the temperature witch predicted with high accuracy is raised at the moment heating source passes the measuring points. So, there is difference of time between idealization of welding and considering of moving heat source faithfully. However, temperature history by idealization of welding is well simulated a high accuracy prediction results.

지반 투수계수와 양수량 조건이 복수정 지열 히트펌프 시스템의 성능에 미치는 영향 (The Effect of Soil Permeability and Pumping Rate on Performance of Two-well Geothermal Heat Pump System)

  • 조정흠;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권4호
    • /
    • pp.28-34
    • /
    • 2015
  • The groundwater heat pump (GWHP) systems have great potential for heating-cooling system which use annual constant groundwater temperature for heat source. Generally, the performance of GWHP system significantly depends on the geological and hydraulic properties such as hydraulic conductivity, thermal conductivity, soil condition so on. Therefore, in order to use GWHP systems efficiently, it is necessary to analyze the effect of design factors on the system performance. However, there are a few researches on the optimum design method for the open-loop geothermal system. In this research, the design factor in the open-loop geothermal system was analyzed quantitatively for the optimal design method by using numerical simulation. As a result, it was found that the temperature change of heat source depends on the design factor.

IEA ECBCS Annex 54 방법에 근거한 PVT-GSHP 시스템 경제성 평가 연구 (PVT-GSHP System Economic Evaluation Study with IEA ECBCS Annex 54 Method)

  • 박진우;강은철;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.64-71
    • /
    • 2014
  • This study is to perform economic analysis of a PVT-GSHP (Photovoltaic Thermal-Ground Source Heat Pump) system compared to the conventional system which consists of a boiler and a chiller. This research has simulated, developed and analyzed four systems for application in a residential and an office building which was based on the hourly EPI (Energy Performance Index, $kWh/m^2yr$). Case 1 includes a boiler and a chiller to meet heating and cooling demands for a house. Case 2 is the same conventional system as Case 1 for a office. Case 3 is simple summation of Case 1 and 2. And Case 4 is utilizing a PVT-GSHP to meet the combined loads of the house and office. The economic evaluation study was based on IEA ECBCS Annex 54 subtasks C economic assessment methods. This study indicated that PVT-GSHP system can save a building's energy up to 53.9%. Also the SPB (Simple Payback) of the PVT-GSHP system with 0%, 50% initial incentive was 14.5, 6.7 year respectively.

태양열 및 외기 열원식 히트펌프 시스템 시뮬레이션 (Simulation of Solar and Ambient-air-assisted Heat Pump)

  • 백남춘;박준언;송병하;이진국;김홍제
    • 태양에너지
    • /
    • 제20권4호
    • /
    • pp.17-24
    • /
    • 2000
  • Thermal performance of a SAAHPS (Solar and Ambient-air-assisted Heat Pump System) located in KIER is simulated with TRNSYS 14.2. The SAAHPS is composed of dual evaorators, each of which is used as a solar fluid heat source and an air fluid heat source. Polynomial coefficients data for the SAAHPS is supplied with Frigosoft, a program widely used for heat pump modeling. In general, collector area and storage volume are 2 key parameters in SAAHPS thermal performance. A parametric study is performed in this study to assess sensitivity of collector area and storage volume in SAAHPS. We concluded that firstly collector area and storage volume are the primary variables in SAAHPS thermal performance, secondly COP of SAAHPS is higher than that of conventional heat pumps. Therefore. collector efficiency can be enhanced swith SAAHPS during a heating season.

  • PDF

지중열원 열펌프시스템의 성능해석 (A Study on the Performance of Ground Source Heat Pump System)

  • 이세균;우정선;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.69-76
    • /
    • 2005
  • The performance of water-to-water heat pump system coupled with the ground source vertical heat exchanger is presented in this paper. The CAP program of Florida Heat Pump Co. is used to predict the heat pump performances while the EED program calculates the borehole fluid temperature. It is shown that COPH increases with decreasing the temperature of output water for the operation of heating mode and COPR increases with increasing temperature of output water for the operation of cooling mode. The value of specific heat extraction rate must be moderate to insure the reasonable installation cost of borehole system. With $1^{\circ}C$decrease of $T_{wo}$ the average COPH increase is estimated as about $0.06/^{\circ}C$(for $T_{wo}\;=\;45{\sim}60^{\circ}C$ range) while with $1^{\circ}C$ increase of $T_{wo}$ the estimation of COPR increase is about $0.13/^{\circ}C$(for $T_{wo}\;= \;5{\sim}11^{\circ}C$ range) at the specific heat extraction rate of 30W/m.

온배수를 열원으로 활용하는 생태산업단지 조성에 관한 기초 연구 (Basic study on Eco-industrial Park utilizing thermal effluents as heat source)

  • 김동규;강대석;정용현
    • 수산해양교육연구
    • /
    • 제21권3호
    • /
    • pp.400-408
    • /
    • 2009
  • The purpose of this study is to know the concept of Eco-industrial Park and How to use the thermal effluents from power plants. Thermal effluents, which use sea water for cooling, from power plants have been discharged with about $6{\sim}7^{\circ}C$ higher temperature than near sea area. Therefore, it could effect on the marine ecosystem as a external pressure factor that increase the artificial thermal load in near sea area. The applications of thermal effluents had been surveyed through the several internal and external cases for utilizing heat sources and reducing the thermal load. As the precedence research for applying, the amount of heat sources of thermal effluents was evaluated. When the thermal effluents was fully applied in heat sources and available heat, assume that use heating season by 12 hours a day of demanded available heat, it was possible to calculate total 198 Tcal of energy saving.