• Title/Summary/Keyword: Heating situation

Search Result 104, Processing Time 0.023 seconds

Temperature Distribution of a Low Temperature Heat Pipe with Multiple Heaters for Electronic Cooling

  • Noh, Hong-Koo;Song, Kyu-Sub
    • ETRI Journal
    • /
    • v.20 no.4
    • /
    • pp.380-394
    • /
    • 1998
  • A numerical study has been performed to predict the characteristics on the transient operation of the heat pipe with multiple heaters for electronic cooling. The model of the heat pipe was composed of the evaporator section with four heaters, insulated transport section, and the condensor section with a conductor which is cooled with uniform heat flux condition to surrounding. The governing equations and the boundary conditions were solved by the generalized PHOENICS computational code employing the finite volume method. Two test cases are investigated in present study; Case 1 indicates that the 1st and 2nd heaters among four heating sources are heated off, while the 3rd and 4th heaters are heated on. Case 2 is the inverse situation switched from heating location of Case 1. The results show that the transient time to reach the steady state is shorter for Case 1 than for Case 2. Especially, the temperature difference of the heater during switching operation is relatively small compared to the maximum allowable operating temperature difference in electronic system. Hence, it is predicted that the heat pipe in present study operates with thermally good reliability even for switching the heaters.

  • PDF

Heat Transfer Characteristics of DPH(Dual Pack Heater) in Electric and Fuel Cell(FC) Car (전기 및 연료전지자동차용 DPH 난방장치개발연구)

  • Roh, Hong-Koo;Lim, Kyung-Bin;Noh, Jong-Ho;Lee, Young-Ki;Ko, Jun-Bin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1262-1266
    • /
    • 2009
  • The study aims to analyzed and identify the heat transfer characteristics of heating unit for car using experimental method in order to design DPH. The temperature comparison processes were done with various experimental conditions. In addition, the optimal conditions of DPH design were proposed as field test in real car, hot air flow, transient situation.

  • PDF

A Study on the Facility for Domestic Waste Problems of high Temperatured Combustion and the Alteration of heating surface (폐기물소각로의 고온 연소에 따른 문제와 연소실 전열면 변경에 대한 연구)

  • Kim, Seong-Jung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.3
    • /
    • pp.60-67
    • /
    • 2010
  • Korea's large-scale incinerating facilities of domestic waste were built in the late 1980's. It was found that most of the incinerators were designed during the period and even the ones constructed afterwards have been built without any changes or modifications. However, the nature of waste fed into incinerators is undergoing a radical change due to government policies on waste collection, which is upheld by a research into changes in the heating value of domestic wastes. As a result, refractories and stokers are being damaged in many of the facilities due to overheating. On the other hand, the formation of clinkers on boilers' heating surface, which curbs he at transfer, results in problems such as a fall in used heating value and a rise in the temperature of combustion chambers. Methods are being deployed to resolve the problems-such as spraying water on piles of waste, incinerating food waste by mixing together what has been separately collected, spraying water on combustion chambers, etc. Such actions are not a fundamental solution, nor redesigning and rebuilding incineration facilities is cost-effective. This research seeks to develop a fundamental solution to address the situation.

The Comparison of Vestibular Function and Dynamic Balance Skills between Normal and Hearing-Impaired Children (정상아동과 청각장애아동의 전정기능과 동적균형수행력 비교)

  • Lee Seung-Min;Kim Jin-Sang;Choi Jin-ho
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.33-40
    • /
    • 2000
  • This study was carried out to compare the relation between vestibular function and balance skills in normal with heating-impaired children. The subjects were 20 normal children (8-10 years) and 20 hearing-impaired children (8-10 years). The SCPNT was used to assess vestibular function, then, functional reach test and backward walking test were usee to compare dynamic balance skills of normal and hearing-impaired children according to existence of visual input. The results were as follows : 1. In SCPNT, normal and hearing-impaired children showed statistical significance in all left-sided and right-sided rotations(p<.01), and the vestibular function responses of healing-impaired children were normal $20\%$, abnormal $45\%$, absent $35\%$. 2, To compare dynamic balance skills between normal and healing-impaired according to eye open and eye close, functional reach test did not show statistical significance in eye open situation(p>.05), but showed statistical significance in eye close situation(p<.05). 3. Backward walking test showed statistical significance in eye open and eye close situation(p<.01).

  • PDF

A Study on Design for Energy-saving Based on Analysis of Current Situation in School Facilities (학교시설 현황분석을 통한 에너지절약설계 개선방향 연구)

  • Meang, Joon-Ho;Kim, Sung-Joong;Lee, Seung-Min;Ko, Hyun-Su
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.3
    • /
    • pp.1-8
    • /
    • 2018
  • We suggest improvement direction of energy-saving design based on analysis of current situation in school facilities. School facilities have large area among public buildings. While the number of students is decreasing, the number of school and energy consumption is increasing year after year. School facilities have excellent heat insulation property, but it requires further examination about excessive heat insulation plan. School facilities are using gas heat pump actively for cooling and heating, but has difference in use ratio of ground source heat pump by region. Thus School facilities requires active using of ground source heat pump and BIPV(Building Integrated Photovoltaic System).

Design of Fuse Elements of Current Sensing Type Protection Device for Portable Secondary Battery Protection System (휴대용 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 퓨즈 가용체 설계)

  • Kang, Chang-Yong;Kim, Eun-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1619-1625
    • /
    • 2018
  • Portable electronic devices secondary batteries can cause fire and explosion due to micro-current change in addition to the situation of short-circuit inrush current, safety can not be secured with a general operation limited current fuse. Therefore, in secondary battery, it is necessary for the protector to satisfy both the limit current type operation in the open-short-circuit inrush current and the current detection operation characteristic in the micro current change situation and for this operation, a fuse for the current detection type secondary battery protection circuit can be applied. The purpose of this study is to design a protection device that operates stably in the hazardous situation of small capacity secondary battery for portable electronic devices through the design of low melting fuse elements alloy of sensing type fuse and secures stability in abnormal current state. As a result of the experiment, I-T and V-T operation characteristics are satisfied in a the design of the alloy of the current sensing type self-contained low melting point fuse and the resistance of the heating resistor. It is confirmed that it can prevent accidents of short circuit over-current and micro current change of secondary battery.

The Characteristics of Air Temperature Distribution by Land-use Type -A case study of around Automatic Weather Station in Seoul- (토지이용 유형에 따른 기온 특성 -서울시 자동기상관측지점 주변을 사례로-)

  • Kwon, Young-Ah;Lee, Hyoun-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.4
    • /
    • pp.281-290
    • /
    • 2003
  • The influence of land-use type on surrounding temperature was studied the relationships between land-use types and the air condition analyzing AWS (Automatic Weather Station) data of Seoul from KMA (Korea Meteorological Administration). The distribution of air temperature by land-use type has been influenced by the different heating and cooling rates. The difference of heating rates depending on the land-use type was largest at 2~3hours after sunrise and the difference of cooling rates was largest from 2hours before sunset to 2hours after sunset with its maximum at sunset. The difference of cooling rates is greatest in a clear and calm weather situation and the large difference in cooling rates between the green areas and built-up area is up to $1.5^{\circ}C/h$. By season, the difference of cooling rates is largest in fall and in turn spring, winter and summer. In a cloudy or rainy day, the difference in heating and cooling rates on land-use type is not distinct but the tendency is similar to a clear day. In all seasons, the rate of difference occurrence of the daily range of temperature between the green areas and built-up area was large, especially fall. In a fall with a clear and calm day, the magnitude of the daily range of temperature between the green areas and built-up area was largest.

Investigations and Analyses of Duck Breeding Facilities in Jeollanam-do Province, Korea (전남지역 오리 사육시설 실태 조사 및 분석)

  • Kwon, Kyeong-seok;Yang, Kayoung;Kim, Jong-bok;Kim, Jung-kon;Jang, Donghwa;Choi, Sungmin;Lee, Sang-yeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Number of duck and its breeding facilities have been steadily decreasing for financial and social issues in Korea. Therefore, the 'turning point' for duck industry is strongly demanded. In this study, the questionary survey was carried out to provide backgrounds for developing policy and technology for duck breeding farms. The questionary survey aimed to investigate the information of operation strategy of farm, ventilation, cooling and heating. The total number of survey respondents was 74. In case of facility type, 55.4% of respondents stated they used greenhouse type, 31.3% for winch-curtain type, and 2.7% for windowless type (mechanically ventilated facility). More than 85% of the facilities were using 'natural ventilation', it meant that these situation can restrict the not only environmental control but also the supply policy for 'smart farm' of the Government. 44.6% used the combination of the cross-ventilation method and roof-ventilation method for ventilation operation in summer season, and 31.1% followed only the cross-ventilation method. In case of winter season, 36.5% used the cross-ventilation method, and 33.3% used the combination of cross and roof-ventilation, method. For the ventilation strategy, about 86.5% depended on farmer's experience. In case of heating and cooling, 79.7% were using kerosene heater for winter season, and 43.2% were using mist-spray for summer season, respectively. More than 75% stated that cooling and heating strategies were based on farmer's experience. From the analyses of the survey results, a few proposals for developing policy and technology for duck breeding farm was suggested.

Numerical study on the transient operation characteristics of the heat pipe cooling system with the multiple uniform heating components for broadband digital cross-connect system (다수의 균일발열부품이 접촉된 광대역 회선분배 시스템 냉각용 히트파이프 시스템의 비정상 동작특성에 관한 수치적 연구)

  • No, Hong-Gu;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.734-749
    • /
    • 1998
  • A numerical study t predict the characteristics on transient operation of the heat pipe cooling system with multiple heaters for electronic system has been performed. The heat pipe cooling system of 45 cm length and 16 mm diameter was composed of evaporator section with four heaters which simulate electronic components, insulated transport section, and condenser section with a conductor which was cooled under the constant heat flux boundary condition. Two test cases were investigated in present study; Case 1 indicated that the 1st and 2nd heaters among four heaters were heated off, while the 3rd and the 4th heaters were heated on. Case 2 was the inverse situation switched from heating locations of Case 1. Case 3 indicated that the 1st and 4th heaters among four heaters were heated off, while the 2nd and 3rd heaters were heated on. The results showed that the transient time to reach the steady state is shorter for Case 1 than for Case 2. Especially, the maximum temperature among the heaters which simulate electronic components during switching operation is relatively small compared to the maximum allowable operating temperature in electronic system. It is concluded that the heat pipe cooling system in present study operate with the good thermal reliability even for sudden switching situation of the heaters.

Performance Characteristics of Organic Rankine Cycles Using Medium Temperature District Heating Water as Heat Source (지역난방용 중온수 열원 유기랭킨사이클 성능 특성)

  • Park, Woo-Jin;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2016
  • It is becoming increasingly important to make use of alternative energy source. because It is not able to rely on only fossil fuel for the recent increasing demand of energy consumption. With this situation, lots of studies for utilizing low grade energy such as industrial waste heat, solar energy, and geothermal energy have been conducted. The aim of this study is to predict the operation characteristics of working fluid by using performance analysis program (ThermoFlex) through the system analysis which is not mixing district return water but using ORC(Organic Rankine Cycle, hereinafter ORC) as a downstream cycle when accumulating district heating (hereinafter DH). In this study, We conducted the performance analysis for the case which has the district heating water temperature($120^{\circ}C$) and Flow rate of $163m^3/h$ (including District Heating return water flow), and examined several working fluid which is proper to this temperature. The case using R245fa (which is the best-case) showed 269.2kW power output, 6.37% efficiency. Additionally, Cut down on fuel was expected because of the boiler inlet temperature increase by being Formed $57.3{\sim}85^{\circ}C$ in a temperature of district heating return water, depending on a pressure change of a condenser in ORC system.

  • PDF