• Title/Summary/Keyword: Heating period

Search Result 539, Processing Time 0.028 seconds

Economic analysis of Electric heating appliances (전기난방기구의 경제성 분석 비교)

  • Kim, Yong-Ha;Lee, Kwang-Sung;Nam, Kim-Hyun;Park, Nam-Chul;Woo, Sung-Min;Kim, Mi-Ye;Lim, Hyun-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.448-452
    • /
    • 2006
  • Many kinds of electric heating appliance is used by user interface and desire. Far infrared ray heating system can use a kind of main heating appliance. This paper gives un saving amounts, energy curtailment money and payback period between far infrared ray heating system and existing electric heating appliance - EHP, electric air heater, electric radiator, electric floor heating system - from economy analysis.

  • PDF

Development of Turbine Rotor Bending Straightening Numerical Model using the High Frequency Heating Equipment (고주파 가열 장비를 활용한 터빈로터 휨 교정수식모델 개발)

  • Park, Junsu;Hyun, Jungseob;Park, Hyunku;Park, Kwangha
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.269-275
    • /
    • 2021
  • The turbine rotor, one of the main facilities in a power plant, it generates electricity while rotating at 3600 RPM. Because it rotates at high speed, it requires careful management because high vibration occurs even if it is deformed by only 0.1mm. However, bending occurs due to various causes during turbine operating. If turbine rotor bending occurs, the power plant must be stopped and repaired. In the past, straightening was carried out using a heating torch and furnace in the field. In case of straightening in this way, it is impossible to proceed systematically, so damage to the turbine rotor may occur and take long period for maintenance. Long maintenance period causes excessive cost, so it is necessary to straighten the rotor by minimizing damage to the rotor in a short period of time. To solve this problem, we developed a turbine rotor straightening equipment using high-frequency induction heating equipment. A straightening was validated for 500MW HIP rotor, and the optimal parameters for straightening were selected. In addition, based on the experimental results, finite element analysis was performed to build a database. Using the database, a straightening amount prediction model available for rotor straightening was developed. Using the developed straightening equipment and straightening prediction model, it is possible to straightening the rotor with minimized damage to the rotor in a short period of time.

Research on the actual condition of 'Under Floor Radiant Heating for Apartment Housing' (주거용건물의 바닥복사 난방방식에 대한 실태조사 연구)

  • Woo, Byung-Kwan;Lee, Sung;Kim, Sam-uel
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.81-86
    • /
    • 2007
  • The research analyzes the arrangement of boiler and hot water header, the method of radiator pipe setting, hot water supply control, hourly heating situation of each room for underfloor radiant heating systems in Korea and suggests an alternative to improve to efficient heating method. One of the best options for install position of hot water distributor is under kitchen sink which is center point of all rooms, according to previous research of the energy saving strategies. When the radiator pipes are arranged to each individual room instead of bedrooms through livingroom and kitchen, it has energy saving effects. For rooms without occupancy according to a time period, hot water supply method should be intermittent heating rather than continuous heating. For this intermittent heating method, individual control of hot water supply is more practical, and it can lead to massive energy savings. The intermittent heating system has time-lag, so it is more effective in energy saving with mild and comfort condition if the spaces are preheated by automatic control equipment prior to required time.

Modeling of Winter Time Apartment Heating Load in District Heating System Using Reduced LS-SVM (Reduced LS-SVM을 이용한 지역난방 동절기 공동주택 난방부하의 모델링)

  • Park, Young Chil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.6
    • /
    • pp.283-292
    • /
    • 2015
  • A model of apartment heating load in a district heating system could be useful in the management and utilization of energy resources, since it could predict energy usage and so could assist in the efficient use of energy resources. The heating load in a district heating system varies in a highly nonlinear manner and is subject to many different factors, such as heating area, number of people living in that complex, and ambient temperature. Thus there are few published papers with accurate models of heating load, especially in domestic literature. This work is concerned with the modeling of apartment heating load in a district heating system in winter, using the reduced least square support vector machine (LS-SVM), and with the purpose of using the model to predict heating energy usage in domestic city area. We collected 23,856 pieces of data on heating energy usage over a 12-week period in winter, from 12 heat exchangers in five apartments. Half of the collected data were used to construct the heating load model, and the other half were used to test the model's accuracy. The model was able to predict the heating energy usage pattern rather accurately. It could also estimate the usage of heating energy within of mean absolute percentage error. This implies that the model prediction accuracy needs to be improved further, but it still could be considered as an acceptable model if we consider the nonlinearity and uncertainty of apartment heating energy usage in a district heating system.

Development of a Method to Estimate the Seasonal Heating Load for Plastic Greenhouses (플라스틱 온실의 기간난방부하 산정 방법 개발)

  • Nam, Sang Woon;Shin, Hyun Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.37-42
    • /
    • 2015
  • In order to provide fundamental data for the creation of environmental design criteria for horticultural facilities, we developed a method to easily calculate the seasonal heating load applying heating degree-hour while taking into account heating load reductions due to solar radiation in the daytime, and reviewed through greenhouse heating experiments. Heating experiments and measuring meteorological environments were carried out in three greenhouses located at Buyeo, Cheonan, and Buan, and we derived reduction factors of seasonal heating load according to hours of sunshine. Daily mean hours of sunshine during the experiment period in each of the greenhouse was 4.0 to 8.3 hours, and the reduction factor of seasonal heating load was 0.64 to 0.85, has been shown to decrease linearly with the increase in hours of sunshine. A method to estimate the seasonal heating load for greenhouses was developed using the reduction factor of seasonal heating load derived from the greenhouse heating experiment, including the adjustment factor of seasonal heating load according to hours of sunshine. The developed method was validated through heating experiments in a greenhouse located at Cheonan. Greenhouse seasonal heating loads calculated by the method developed in this study were analyzed to show the estimate error of 1.2 to 5.0%. It showed that the accuracy increased 2.3 times more than when using the heating load reduction factor of 0.75 applied uniformly in previous studies. Thus, the calculation method of seasonal heating load for greenhouses considering hours of sunshine developed in this study could be utilized for energy estimation, management planning, and economic evaluation in greenhouse design.

Browning Reaction of Fresh Ginseng (Panax ginseng C.A. Meyer) as Affected by Heating Temperature (가열온도에 따른 수삼의 갈변반응 특성)

  • 이종원;이성계
    • Journal of Ginseng Research
    • /
    • v.19 no.3
    • /
    • pp.249-253
    • /
    • 1995
  • In the browning reaction of Korean ginseng, it appears that enzymatic and non-enzymatic browning reaction occurred in the initial stage of heating fresh ginseng at low temperature, and then non-enzymatic browning reaction followed in the drying period after heating. Activation energy of the browning reaction for red ginseng was about 9.0 kcal/mol. Browning reaction of red ginseng was accede- rated with an increase in steaming time, and a great extent of browning reaction occurred between 60-90 min of steaming at 10$0^{\circ}C$. Browning pigments of red ginseng were mostly water soluble subset.

  • PDF

A Study on the Acceptance of the 'On-dol' in the Official - Residences Built by the Japanese Colonist in 1905~1945 - (1905~1945년에 지어진 일본 관사의 온돌 수용 - 국가기록원 소장 일제시기 관영건축도면을 중심으로 -)

  • Baek, Yun-Jin;Jeon, Bong-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.1-9
    • /
    • 2010
  • The purpose of this study is to analyze the acceptance of the On-dol, Korean underfloor heating system, in the official residences built by the japanese colonist in 1905~1945. The On-dol is the main element that formed Korean housing culture throughout our her history. Since the climate of Korea is colder than that of Japan, the Japanese-style house built in Korea needed to take measures for the harsher winter. Therefore the official residences built during the japanese colonial period, built after the Japanese-style house, accepted the On-dol as additional heating system for their houses. Over forty years the official residences were constructed in large quantities, and many of the official residences also installed the On-dol. Some important changes were discovered about the acceptance of the On-dol. To define this concretely, this study was performed empirically through the comparison and analysis of governmental architectural drawings. There is great significance to consider that an architectural element of Korea influenced the Japanese-style houses. In conclusion, differences between the official residences with the On-dol and those without, during the latter stage of the japanese colonial period have founded. These results demonstrate that this element of traditional korean architecture affected the development of foreign houses built in Korea.

Drying Characteristics of Plating Sludge by Microwave (마이크로파 가열에 의한 도금슬러지 건조특성)

  • 문경환;손종렬;김덕찬
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.9-15
    • /
    • 1998
  • Microwave heating and drying processes have been well established in various industrial applications. Feasibilities of successful application of microwave drying to many material have been shown on the laboratory or pilot-plant scale. The microwave drying behavior of plating sludge are considered in this paper. The plating sludge containing 70%, 80% and 90% water exposed to microwave power at 2,450 MHz, 700W. An experimental microwave drying apparatus was designed and constructed to monitor weight loss during drying. By studying the drying characteristic curve, the moisture in sludge was almost classified into two categories : free moisture and intestinal moisture. And the critical moisture contents at which the drying rate ceases to be constant were from 10.1 to 10.5%. A simple drying model is proposed which may be used to describe drying behavior of plating sludge. The constant rate and the falling rate periods in microwave drying were addressed separately. From the eqation of constant rate period the drying rate constants decreased exponentially with increasing depth. Microwave heating compared with conventional heating offered higher heating rates from 9 to 16 times. Therefore, microwave drying process can be effective in removing moisture from plating sludge.

  • PDF

Experimental Study on the Characteristics of Combustion in the Indirect Moxibustion with Ginger (격강구(隔薑灸)의 연소(燃燒) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Geon-mok;Lee, Geon-hui;Moon, Sung-jae;Hwang, Byung-chun;Guk, Uo-suk;Jang, Ji-yeon;Kim, Yang-jung;Jang, Jae-ho;Yun, Ju-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.3
    • /
    • pp.193-214
    • /
    • 2004
  • Objective : The purpose of this study is to investigate the mechanism and effect of moxibustion with ginger objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with ginger. Methods : We have selected the indirect moxibustion with ginger among many indirect moxibustions. We produced a slice of ginger to a thickness of 3, 4, 5mm and the moxa cone having a diameter of 8mm, a height of 10mm for making a comparative study of characteristics of moxa cone according to change the density. We have made a comparative study of the thermodynamic characteristics of moxibustion with ginger with or without holes. We measured combustion times and calculated temperatures, temperature gradients in each period during a combustion of moxa. Results : 1. We found out it was not significantly influenced by the existence of the punched holes in a slice of ginger because the punched holes grow smaller immediately. 2. The duration of the preheating period became longer according to thickness of a slice of ginger and was not directly proportional to the density of moxa cone. The duration of the preheating period was extremely short when it burned a 100mg moxa cone. That was influenced by the density of moxa cone. 3. The duration of the heating period became longer according to thickness of a slice of ginger likewise the preheating period bacause the density of moxa cone had effected on the combustion characteristics. The duration of the heating period was extremely long when it burned a 100mg moxa cone. On the other hand the maximum temperature in the heating period was appeared that the combustion with a thin slice of ginger was highest and measured that the large density of moxa cone was higher. But the maximum temperature in the heating period was about $37.8^{\circ}C{\sim}44.2^{\circ}C$respectively lower in others. 4. The duration of the retaining period was some doubling shorter than that of the heating period that is concerned the shape of moxa cone. The temperature measured the close of a retaining period was $36.6^{\circ}C{\sim}41.8^{\circ}C$, that was considerably lower temperature. 5. The mean ascending temperature velocity and the mean descending temperature velocity were $0.042{\sim}0.073^{\circ}C/sec$, $-0.027{\sim}-0.064^{\circ}C/sec$ respectively. Then, the ascending temperature velocity was some faster than the ascending temperature velocity. Conclusions : The quantitative standard for obtaining the effective heating stimulation is that if the slice of ginger made a hole in it, we had to use the needle above 1.5mm diameter. The recommended size of a slice ginger is the 14mm diameter and the 2~3mm thickness. The moxa cone is formed the conical shape that the base diameter was 8mm, the height was 10mm, the density was $600mg/cm^2$.

  • PDF

Influence of PE Film House culture with Non Heating on Growth and Yield of Forage Rape (무가온 Vinyl House 재배가 사초유채의 생산특성과 수량에 미치는 영향)

  • 안계수;권병선;정동희;김상곤
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.16 no.3
    • /
    • pp.215-218
    • /
    • 1996
  • This study examines the possibility of early production of forage rape (cv. Akela and Velox) in the period of wintering. Bolting date was Feb. 2 to Feb. 9 in PE film house culture by non-heating and Mar. 3 to Mar. 12 in open field culture. And flowering date was Feb. 24 to Mar. 3 in PE film house culture by non-heating, so it was 30~50 days faster than the open field culture of Apr. 17 to Apr. 22. Fresh matter yield was 8, 356~4, 887 kg/10a in PE film house culture by non-heating, so it was 1, 431~1, 603 kg/10a yield increase than in the open field culture of 7, 253~7, 456 kg/10a Dry matter yield was 953~963 kg/10a in PE film house culture by non-heating, so it was 71~284 kg/10a yield increase than in the open field culture of 669~892 kg/10a.

  • PDF