• Title/Summary/Keyword: Heating panels

Search Result 55, Processing Time 0.03 seconds

The Study on the Development of The Non-Gravity Fluidized Dryer (무중력 유동층 건조기 개발에 관한 연구)

  • Kim, Seok-Cheol;Bae, Dong-Kyu;Han, Ji-Woong;Kum, Sung-Min;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.9
    • /
    • pp.1195-1209
    • /
    • 2000
  • The purpose of this study is to develop the non-gravity fluidized dryer. In this non-gravity fluidized dryer the fluidized zone is produced by two paddles in mixer, which maximizes the surface area of materials and then heated air through the guiding panels dehumidify them. This can conduct the drying process quickly and control moisture contents to lower limits. The ventilation system is closed loop system, which can be changeable to open system, and can be used as a multi-purposed dryer in which mixing, drying, granulating and cooling process is conducted. In order to develop the non-gravity fluidized dryer, in the first fundamental experiments were performed to mixing accuracy and then the other parts of dryer and control system were examined to check whether they were designed properly and operated harmoniously with mixer. Also the preparatory experiments were fulfilled to examine the efficiency and reliability of the dryer. Lastly, on the basis of preparatory experiments, performance test for the non-gravity fluidized dryer carried out for the variation of the initial moisture contents, desired moisture contents, heated air velocity and heating temperature.

Numerical simulation of the thermoelectric behavior of CNTs/CFRP aircraft composite laminates

  • Lin, Yueguo;Lafarie-Frenot, Marie Christine;Bai, Jinbo;Gigliotti, Marco
    • Advances in aircraft and spacecraft science
    • /
    • v.5 no.6
    • /
    • pp.633-652
    • /
    • 2018
  • The present paper focuses on the development of a model for simulating the thermoelectric behavior of CNTs/CFRP Organic Matrix Composite (OMC) laminates for aeronautical applications. The model is developed within the framework of the thermodynamics of irreversible processes and implemented into commercial ABAQUS Finite Element software and validated by comparison with experimental thermoelectric tests on two types of composites materials, namely Type A with Carbon Nanotubes (CNT) and Type B without CNT. A simplified model, neglecting heat conduction, is also developed for simplifying the identification process. The model is then applied for FEM numerical simulation of the thermoelectric response of aircraft panel structures subjected to electrical loads, in order to discuss the potential danger coming from electrical solicitations. The structural simulations are performed on quasi-isotropic stacking sequences (QI) $[45/-45/90/0]_s$ using composite materials of type A and type B and compared with those obtained on plates made of metallic material (aluminum). For both tested cases-transit of electric current of intermediate intensity (9A) and electrical loading on panels made of composite material-higher heating intensity is observed in composites materials with respect to the corresponding metallic ones.

A Study on the Validation of Heliodon for Daylighting Performance Evaluation (자연채광성능 평가를 위한 태양고정형 Heliodon의 유용성 검증에 관한 연구)

  • Kim, Jeong-Tai;Lee, Ji-Hyun;Kim, Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.51-62
    • /
    • 2004
  • Architects may evaluate building models to see how a building will shadow itself and its neighbors at various times. A heliodon, a tilt-table which is a machine that imitates the rotation and orbit of the Earth, helps architects wanting to analyze patterns of shadow patch, passive solar heating options, site solar panels, or control solar heat gain. The heliodon swivels in three directions for setting latitude, season, and time of day. Using the device, an architect first clamps a model to the tabletop, then turns the table to the coordinates of interest. Usually, the winter and summer solstices receive strong attention, for they represent extreme cases, A more recent installation at a university adds to its heliodon a set of lamps to recreate the illumination level and more accurate patterns of shadow patch. The table holds the building model at various angles to a spotlight, which mounts in the pole. The set of scale model measurement describes the validity of various electric lamps as an artificial sun to approximate the sun's parallel rays, helping designers to distinguish between illuminated areas in and around a building and those regions falling in the shadows.

Efficient Layered Manufacturing Method of Metallic Sandwich Panel with Pyramidal Truss Structures using Infrared Brazing and its Mechanical Characteristics (피라미드 트러스형 금속 샌드위치 판재의 적외선 브레이징을 이용한 효율적 적층식 제작 및 특성에 관한 연구)

  • Lee, Se-Hee;Seong, Dae-Yong;Yang, Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.8
    • /
    • pp.76-83
    • /
    • 2010
  • Metallic sandwich panels with pyramidal truss structures are high-stiffness and high-strength materials with low weight. In particular, bulk structures have enough space for additional multi-functionalities. In this work, in order to fabricate 3-D structures efficiently, Layered Manufacturing Method (LMM) which was composed of three steps, including crimping process, stacking process and bonding process using rapid infrared brazing, was proposed. The joining time was drastically reduced by employing infrared brazing of which heating rate and cooling rate were faster than those of conventional furnace brazing. By controlling the initial cooling rate slowly, the bonding strength was improved up to the level of strength by conventional vacuum brazing. The observation of infrared brazed specimens by optical microscope and SEM showed no defect on the joining sections. The experiments of 1-layered pyramidal structures and 2-layered pyramidal structures subject to 3-point bending were conducted to determine structural advantages of multilayered structures. From the results, the multi-layered structure has superior mechanical properties to the single-layered structure.

Characteristics of Non-gravity Fluidized Dryer (무중력 유동층 건조기의 건조특성에 관한 연구)

  • Kim, S.C.;Bae, D.K.;Han, J.W.;Kum, S.M.;Lee, C.E.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.220-227
    • /
    • 2000
  • The purpose of this study is to develop the non-gravity fluidized dryer. In this non-gravity fluidized dryer the fluidized zone is produced by two paddles in mixer, which maximizes the surface area of materials and then heated air through the guiding panels dehumidify them. This can conduct the drying process quickly and control moisture contents to lower limits. The ventilation system is closed loop system, which can be changeable to open system, and can be used as a multi-purposed dryer in which mixing, drying, granulating and cooling process is conducted. In order to develop non-gravity fluidized dryer, in the first the fundamental experiments performed to mixing accuracy and then the other parts of dryer and control system were examined to check whether they were designed properly and operated harmoniously with mixer. Also the preparatory experiments were fulfilled to examine the efficiency and reliability of dryer. Lastly, on the basis of preparatory experiments in case the initial moisture contents, desired moisture contents, heated air velocity and heating temperature were vary, performance test for the non-gravity fluidized dryer carried out.

  • PDF

A Study on the Eco-Tecnique of EcoCenter - Focused on the Building Material and Solar System - (에코센터의 생태건축기술에 관한 연구 - 건축재료와 태양에너지활용시스템을 중심으로 -)

  • Choi, Young-Ho;Shim, Woo-Gab
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.65-72
    • /
    • 2004
  • Ecological architecture enables people to recycle and reuse architectural resources within the category of ecosystem and also to minimize the effect on environment in a whole process, including architectural planning, usage and exhaustion to use sustainable energies. Rammed earth wall construction method utilized in EcoCenter located in Crystalwaters ecological village in Austrailia is a good example, which maximizes its advantages and also covers its limits to use soil and wood as structural resources. In a case of wood, they used non-treated timber to minimize environmental load and utilized used materials in openings. In the roofs, aluminum coated steel which is plated with zinc collects rain effectively even though it is not regenerable. Nontoxic finishes and insulation in floor and ceiling with used papers are able to minimize its environmental load. Solar energy system applied in EcoCenter enables them to market extra energy with electricity companies as well as support needs of its own buildings to utilize photovoltaic panel system with PV panels. Passive solar system is planned effectively in heating and cooling to apply regenerative walls in a use of rammed earth wall construction and natural ventilation systems through openings.

A Development of Counter Flow Type of Cooling System for Effective Panel Cooling (효과적인 패널 냉각을 위한 대향류형 냉각장치의 개발)

  • Lee, Joong-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.802-807
    • /
    • 2010
  • The high efficient and cooling system is very important to the control panels of electrical distributors, and Industrial automated system including computer. Also, it can be used widely in various industrial systems such as industrial robots, numerically controlled machining center, and so on. The cooling method which flowing gasses were forced to circulate by compulsion was adapted in this study. then development of counter flow type of cooling system for effective panel cooling. In the present study, fin assembly was developed for this cooling system. As results, the developed system has the improvements of cooling performances and radiant heat ratio. Its increasing of airflow mass is about 20%, and radiation rate of heating is twice or more as high as the conventional system.

Evaluation of Residential Performance in Commercialization of Flexible Unit Infra Free Residential for Disaster (재난 시 대응을 위한 Flexible-Unit형 인프라 프리(임시)주거의 성능평가)

  • Park, Beungyong;Cho, Jinkyun;Jeong, Yongdae;Lee, Wonhak
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.37-49
    • /
    • 2018
  • In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.

A Study on the Improvement Direction of Life Safety Codes for High Fire Risk Building Applications (화재위험성이 높은 건축물의 용도를 대상으로 한 인명안전기준의 개선방향)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Lee, Byeong-Heun;Koo, In-Hyuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.53-54
    • /
    • 2021
  • Grenfell Tower was renovated in 2014 and 2016 at a high cost to replace the exterior materials, windows and co-heating facilities of the building. The exterior materials used during the repair work were sandwich panels filled with polyethylene and plastic, which were expanded on the aluminum metal surface. It is a product called Celotex RS 5000, a low-resolution but inexpensive repair material, and is currently an external material that cannot be used in high-rise buildings. Similar domestic fire cases began to focus social attention on the safety of high-rise buildings through the Busan Residential Complex Fire (2010), Uijeongbu Urban Living Housing Fire (2015), and Ulsan Residential Complex Fire (2020), and residents' safety concerns are increasing. In Korea, the occurrence and risk of similar fires are high, so setting up fire prevention measures through fire case investigation is considered the most basic measure in securing human safety. Therefore, the purpose of this study is to examine the status of fire damage caused by domestic and foreign eruptions, domestic and international research status and related regulations on external materials and windows starting from the Grenfell Tower fire in England.

  • PDF

Analysis of the Risk of Heat Generation due to Bolt Loosening in Terminal Block Connector Parts (볼트풀림에 의한 터미널 블록의 접속부 발열 위험성 분석)

  • Yeon, Yeong-Mo;Kim, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.67-75
    • /
    • 2020
  • In this study, the risk of heat generation due to normal and overload currents that vary with the abnormal loosening angle of wire-connecting bolts were identified. The risks were analyzed based on the thermal characteristics to minimize the carbonization accidents of terminal blocks inside distribution panels typically used in industrial sites. We applied a method for measuring the heating temperature and temperature variations in the terminal blocks in real-time by installing a resistance temperature detector sensor board in the terminal block. The experimental results showed that the terminal block model with a low-rated current exhibited a higher heating temperature, thus, confirming the need to select the terminal block capacity based on load currents. Additionally, the higher the rated current of the terminal block with a high-rated current and the higher the degree of loosening, the faster the carbonization point. Such heating temperature monitoring enabled real-time thermal temperature measurement and a step-by-step risk level setting through thermal analysis. The results of the measurement and analysis of carbonization risks can provide a theoretical basis for further research regarding the risk of fire due to carbonization. Furthermore, the deterioration measurement method using the temperature sensor board developed in this study is widely applicable to prevent fires caused by poor electrical contact as well as risk-level management.