• Title/Summary/Keyword: Heating panels

Search Result 55, Processing Time 0.023 seconds

Field Enhanced Rapid Thermal Process for Low Temperature Poly-Si TFTs Fabrications

  • Kim, Hyoung-June;Shin, Dong-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.665-667
    • /
    • 2005
  • VIATRON TECHNOLOGIES has developed FE-RTP system that enables LTPS LCD and AMOLED manufacturers to produce poly-Si films at low cost, high throughput, and high yield. The system employs sequential heat treatment methods using temperature control and rapid thermal processor modules. The temperature control modules provide exceptionally uniform heating and cooling of the glass substrates to within ${\pm}2^a\;C$. The rapid thermal process that combines heating with field induction accelerates the treatment rates. The new FE-RTP system can process $730{\times}920mm$ glass substrates as thin as 0.4 mm. The uniform nature of poly-Si films produced by FE-RTP resulted in AMOLED panels with no laser-Muras. Furthermore, FE-RTP system also showed superior performances in other heat treatment processes involved in poly-Si TFT fabrications, such as dopant activation, gate oxide densification, hydrogenation, and pre-compaction.

  • PDF

Women's Comfort Temperature Range and Dynamic Temperature Change for Maintaining Thermal Comfort in Low Temperature Environment (저온환경에서 여성 온열쾌적성 유지를 위한 쾌적온도범위 및 동적 온도변화 연구)

  • Kim, Soyoung;Lee, Okkyung;Lee, Heeran
    • Fashion & Textile Research Journal
    • /
    • v.22 no.6
    • /
    • pp.853-861
    • /
    • 2020
  • Various types of clothing are being developed to boost thermal comfort during cold winters along with research on change of body temperature when heating is applied. There is a noticeable behavioral difference by gender when using heating panels in a cold environment; however, research on women has been insufficient. This study find a temperature range that provides sustainable thermal comfort in a low temperature environment by observing temperature and change of temperature when subjects are classified according to physical activities or cold sensitivities. For the study results, 8 women in their 20s were subjected to experiment in a low temperature environment for 75 minutes (sitting position: 30 min., running: 15 min., and sitting position: 30 min.). Subjects were asked to turn on/off the heating panel freely to analyze the range of comfortable temperature and clothing microclimate; in addition, skin temperature and heating panel temperature were measured and analyzed at 9 points. As a result, temperature at which subjects turn on and off the heating panel indicated a statistically meaningful difference between the cold sensitivity group depending on exercise or non-exercise. The range of comfortable abdomen temperature was wider than the lower back and was significantly reduced when the subject was running. The range of comfortable temperature was also largest for the heating panel temperature, microclimate, and skin temperature in suggesting that adequate adjustment will be required depending on the surrounding environment or movement of the wearer.

Assessment of Utilization of Auxiliary Heating Device for Prevention of Condensation in Built-in Furniture in Winter (겨울철 공동주택에서 붙박이장 내 보조난방장치를 활용한 결로 저감 효과 평가)

  • Lee, Hyun-Hwa;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.99-106
    • /
    • 2017
  • Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Most of all, occupants in residential buildings has suffered from property damages due to the condensation and mold of built-in furniture. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. The aim of paper is to analyze the characteristics of adjacent area around built-in furniture's condensation problem and the thermal environment around the built-in furniture in winter through the field measurements at apartment buildings. In this research, the thermal conditions and surface temperature around the built-in furniture were measured during winter season. In this research, we analyzed thermal conditions for built-in furniture which were applied and not applied auxiliary heating device. In results, it is important to consider increasing surface temperature for using heater and decreasing absolute humidity due to the occupants' behavior around built-in furniture for preventing condensation.

Investigation on Thermal Effect for a Low Earth Orbit Satellite during Imaging Maneuvering (지구 저궤도 위성의 영상임무 자세에 따른 열적 영향 고찰)

  • Kim, Hui-Kyung;Lee, Jang-Joon;Hyun, Bum-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.12
    • /
    • pp.1216-1221
    • /
    • 2008
  • A low earth orbit satellite with a fixed solar array always has a sun-pointing attitude during daylight, and changes into a nadir-pointing attitude for a imaging mission. Since external heating sources to the satellite panels are Earth irradiation and Albedo during most of daylight in a sun-pointing attitude, the thermal environment condition is relatively stable. However, direct sunlight which is the greatest environmental heating has an affect on the satellite panels during a mission period (10% of one orbit) in a nadir-pointing attitude. In satellite thermal design, thermal effects of a nadir-pointing mission attitude due to this thermal environment change need to be evaluated although the duration of a nadir-pointing attitude is short. Therefore, a nadir-pointing attitude during a mission is incorporated into thermal model and by the thermal analysis result, thermal effects on the satellite are investigated.

Flexible Planar Heater Comprising Ag Thin Film on Polyurethane Substrate (폴리우레탄 유연 기판을 이용한 Ag 박막형 유연 면상발열체 연구)

  • Seongyeol Lee;Dooho Choi
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.1
    • /
    • pp.29-34
    • /
    • 2024
  • The heating element utilizing the Joule heating generated when current flows through a conductor is widely researched and developed for various industrial applications such as moisture removal in automotive windshield, high-speed train windows, and solar panels. Recently, research utilizing heating elements with various nanostructures has been actively conducted to develop flexible heating elements capable of maintaining stable heating even under mechanical deformation conditions. In this study, flexible polyurethane possessing excellent flexibility was selected as the substrate, and silver (Ag) thin films with low electrical resistivity (1.6 μΩ-cm) were fabricated as the heating layer using magnetron sputtering. The 2D heating structure of the Ag thin films demonstrated excellent heating reproducibility, reaching 95% of the target temperature within 20 seconds. Furthermore, excellent heating characteristics were maintained even under mechanically deforming environments, exhibiting outstanding flexibility with less than a 3% increase in electrical resistance observed in repetitive bending tests (10,000 cycles, based on a curvature radius of 5 mm). This demonstrates that polyurethane/Ag planar heating structure bears promising potential as a flexible/wearable heating element for curved-shaped appliances and objects subjected to diverse stresses such as human body parts.

A Study on the Characteristics of the Earth Heat Extraction Using Termosyphon (Termosyphon의 지열채열 성능에 관한 고찰)

  • Shin, H.J.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.226-233
    • /
    • 1993
  • Thermosyphons are simple devices that can passively transport thermal energy over relatively large distance with little temperature degradation. Especially, the thermosyphon system requires no costly energy input and is completely maintenance free. These attributes permit the use of low grade thermal energy for thermal control of structures including the stabilization of highway foundations. This paper presents the experimental results of the snow melting system in which thermosyphon was utilized to ransfer the earth energy to the pavement to remove snow and ice. The test facility, three earth heated and one unheated test panels, is designed to investigate the variables associated with removing snow and ice from pavement surfaces. The results of these test show that the earth heated panel surface temperature is higher $2{\sim}6^{\circ}C$ than unheated panel when the ambient air temperature is $-7^{\circ}C$. The thermal performance of this earth source thermosyphon system for road heating showed that there was no snow on the heated test panels when the snowfall was 5cm average for the region.

  • PDF

Measurement of Step Difference using Digital Holography of ITO Thin Film Fabricated by Sputtering Method (스퍼터링 공법으로 제작한 ITO 박막의 디지털 홀로그래피를 이용한 단차에 대한 측정)

  • Jung, Hyun Il;Shin, Ju Yeop;Park, Jong Hyun;Jung, Hyunchul;Kim, Kyeong-suk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.84-89
    • /
    • 2021
  • Indium tin oxide (ITO) transparent electrodes, which are used to manufacture organic light-emitting diodes, are used in light-emitting surface electrodes of display EL panels such as cell phones and TVs, liquid crystal panels, transparent switches, and plane heating elements. ITO is a major component that consists of indium and tin and is advantageous in terms of obtaining sheet resistance and light transmittance in a thin film. However, the optical performance of devices decreases with an increase in its thickness. A digital holography system was constructed and measured for the step measurement of the ITO thin film, and the reliability of the technique was verified by comparing the FE-SEM measurement results. The error rate of the step difference measurement was within ±5%. This result demonstrated that this technique is useful for applications in advanced MEMS and NEMS industrial fields.

Temperature Distribution Characteristics for Changes in Hot Water Flow in A Small Ocher Jjimjilbang (소형 황토 찜질방의 온수유량 변화에 대한 온도분포 특성)

  • Cho, Dong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.7
    • /
    • pp.74-80
    • /
    • 2020
  • The ocher jjimjilbang for a single-person household that will be studied in this study is 2.1 ㎡ in size, and this study was conducted to implement well-being room heating that is beneficial to health by supplying radiant heat provided by hot water during room heating by embedding hot water panels in the walls of the ocher jjimjilbang to configure a hot water circulating system. In addition, the ocher bed and the ocher walls, which have been verified through many study findings and reference materials, were constructed so that the living life with a bed and the ocher jjimjilbang would be implemented simultaneously. As the mass flow rate of the hot water increased, the magnitude of the wall temperature rise thanks to the hot water increased, and as the flow rate of the hot water increased, the transfer rate of the heat transferred from the wall of the ocher jjimjilbang to the air inside the wall of the ocher jjimjilbang increased.

The Analysis of the Heat Transfer Characteristic in a PDP Ventilation Chamber (PDP용 배기로내 열전달 현상에 관한 해석)

  • Park, Hyung-Gyu;Chung, Jae-Dong;Kim, Charn-Jung;Lee, Joon-Sik;Park, Heui-Jae;Cho, Young-Man;Cho, Hae-Kyun;Park, Deuk-Il
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.385-391
    • /
    • 2000
  • An analysis of the heat transfer in a PDP ventilation chamber has been conducted to investigate the required heat curve and temperature uniformity of the panels. Firstly, experiment in a test chamber has been carried out and compared with the unsteady 3D numerical simulation. Reasonable agreement was found, which suggested that the employed numerical model had its credibility in an actual PDP ventilation process. On this ground, tact-type heating/cooling system was analyzed. The panel temperature was more uniform in the $40^{\circ}C$ tact-type system than in the $80^{\circ}C$ one. Comparison of full simulation of a cart and simplified simulation of one panel shows the panel pitch, which is closely related to a production rate, can be also predicted.

  • PDF

The characteristics of heat storage and emission of PCM in Ondol system (잠열저장재를 이용한 온돌판넬의 축열 및 방열특성에 관한 연구)

  • Cho, Soo;Yoo, Je-In;Chung, Hun-Saeng
    • Solar Energy
    • /
    • v.10 no.2
    • /
    • pp.38-43
    • /
    • 1990
  • The present study was to investigate the use of a phase change material for hydronic radiant floor heating. Two identical unit test cells sized $1.8m^L{\times}1.8m^W{\times}1.8m^H$ were built and installed with specially designed $1.6cm^T{\times}9cm^W{\times}80cm^H$ aluminum Ondol-panels holding 1.25kg of calcium chloride hexahydrate(CCH) each. It was found that the Ondol-panel with CCH reduced the room temperature fluctuations and maintains the phase changing temperature for considerably long duration, $2{\sim}4$ times of heating hour, over no-CCH one.

  • PDF