• Title/Summary/Keyword: Heating pad

Search Result 66, Processing Time 0.022 seconds

The optimum Design of the Multi-flight Screw using Finite Element Analysis (다중날을 가진 스크류의 최적화 설계)

  • 최동열;조승현;김청균
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.248-256
    • /
    • 2001
  • Capacities of screw are pumping, steady flow of polymer melts, volumetric efficiency, steady volumetric throughout etc. they are affected by geometry of screw, heat flux, pressure on inside barrel, rotating velocity, friction coefficient at screw surface etc. Also the temperature of polymer melts by heating pad and injection pressure play a very important role in the injection molding machine. by computation volumetric efficiency increases as rotating velocity increases, flight number increses, and decreases as friction coefficient increases. but volumetric throughout is different :s flight number increases with helix angle variability. so in this paper we analyze thermal distortion and stress of screw includes pressure and temperature distributions by finite element analysis to understand what design factors influence on thermo-mechanical characteristics of screw.

  • PDF

Thermal Stress Induced Spalling of Metal Pad on Silicon Interposer (열응력에 의한 실리콘 인터포저 위 금속 패드의 박락 현상)

  • Kim, Junmo;Kim, Boyeon;Jung, Cheong-Ha;Kim, Gu-sung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.3
    • /
    • pp.25-29
    • /
    • 2022
  • Recently, the importance of electronic packaging technology has been attracting attention, and heterogeneous integration technology in which chips are stacked out-of-plane direction is being applied to the electronic packaging field. The 2.5D integration circuit is a technology for stacking chips using an interposer including TSV, and is widely used already. Therefore, it is necessary to make the interposer mechanically reliable in the packaging process that undergoes various thermal processes and mechanical loadings. Considering the structural characteristics of the interposer on which several thin films are deposited, thermal stress due to the difference in thermal expansion coefficients of materials can have a great effect on reliability. In this study, the mechanical reliability of the metal pad for wire bonding on the silicon interposer against thermal stress was evaluated. After heating the interposer to the solder reflow temperature, the delamination of the metal pad that occurred during cooling was observed and the mechanism was investigated. In addition, it was confirmed that the high cooling rate and the defect caused by handling promote delamination of the metal pads.

The Experimental Estimation of the Effect on the Body Heat by the Artemisia-Lotion Pad

  • Jo, Bong-Kwan;Ko, Yeong-Guy;Jang, Sang-Yeoul;Bae, Jong-Il;Kim, Jong-Kyung;Lee, Dong-Cheol;Lee, Dong-Young;Lee, Ho-Jin;Jo, Bong-Jo;Gu, Ja-Seung;Kwon, Mi-Ja
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2206-2208
    • /
    • 2003
  • This paper is performed to find the effects on body heat by stimulating the skin with the heat of a moxibustion cauterizer and the Artemisia-lotion which cause the extension of the blood vessel. The Artemisia-lotion is made by extracting the vasodilator and antioxidant compounds from the $Artemisia-CH_2Cl_2$ fraction. The moxibustion cauterizer is constructed with a DC power supply and 3 heating electrodes with PTC(Positive Temperature Coefficients) thermistor. The stimulation temperature level of the moxibustion cauterizer is $45^{\circ}C\;-48^{\circ}C$. We gave the subjects the following stimulating conditions; only heat stimulation, only Artemisia -lotion stimulation, and both stimulations. The measurement of body heat was performed with a infrared thermography system . Finally we could estimate the effects of a betterment of circulation of the blood from $Artemisia-CH_2Cl_2$ fraction.

  • PDF

Estimation of Tire Braking Force and Road Friction Coefficient Between Tire and Road Surface For Wheel Slip Control (휠 슬립 제어를 위한 타이어와 노면 사이의 타이어 제동력 및 노면 마찰계수 추정)

  • Hong, Dae-Gun;Huh, Kun-Soo;Yoon, Pal-Joo;Hwang, In-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.517-523
    • /
    • 2004
  • Recently, wheel slip controllers with controlling the wheel slip directly has been studied using the brake-by-wire actuator. The wheel slip controller is able to control the braking force more accurately and can be adapted to various different vehicles more easily than the conventional ABS systems. The wheel slip controller requires the information about the tire braking force and road condition in order to achieve the control performance. In this paper, the tire braking forces are estimated considering the variation of the friction between brake pad and disk due to aging of the brake, moisture on the contact area or heating. In addition, the road friction coefficient is estimated without using tire models. The estimated performance of tire braking forces and the road friction coefficient is evaluated in simulations.

Bilateral Sciatic Neuropathy Following Rhabdomyolysis: A Case Report (횡문근융해증 이후 나타난 양측 좌골신경병: 증례보고)

  • Lee, Sang Yoon;Cha, Jun Min;Kim, Seong Woo;Jeon, Ha Ra
    • Journal of Electrodiagnosis and Neuromuscular Diseases
    • /
    • v.20 no.2
    • /
    • pp.139-143
    • /
    • 2018
  • Rhabdomyolysis is a syndrome caused by injury to skeletal muscles and involves leakage of large quantities of potentially toxic intracellular contents into the plasma. It is known that rhabdomyolysis results in peripheral nerve injury, however, reports of bilateral sciatic neuropathy following rhabdomyolysis are rare. We report a case involving a 42-year-old female patient with no past medical history, who presented with sudden bilateral calf pain, redness, and burning sensation with weakness of both lower extremities after sleeping on an electric heating pad following alcohol drinking. Lower extremity magnetic resonance angiography (MRA) revealed multifocal edema with enhancement of bilateral lower extremity muscles. Clinical and electrodiagnostic tests were consistent with the diagnosis of bilateral sciatic neuropathy following rhabdomyolysis. This is a rare case of bilateral sciatic neuropathy following rhabdomyolysis.

Clinical Characteristics of Thermal Injuries Following Free TRAM Flap Breast Reconstruction (확장 광배근 근피판술을 이용한 유방재건술)

  • Park, Jae Hee;Bang, Sa Ik;Kim, Suk Han;Im, So Young;Mun, Goo Hyun;Hyon, Won Sok;Oh, Kap Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.408-415
    • /
    • 2005
  • Following a transverse rectus abdominis musculocutaneous(TRAM) flap breast reconstruction, denervated state of the flap causes the flap skin prone to thermal injury, calling for special attention. During the last 5 years, 69 breast reconstruction with 72 free TRAM flaps, were performed. Four out of thesse 69 patients sustained burn injury. Heat sources were a warm bag(n=2), heating pad(n=1) and warming light (n=1). The thermal injuries occured from 2 days to 3 months following the reconstruction. Three patients healed with conservative treatment, but one patient required debridement and skin graft. Initially 3 out of 4 patients with the burn had shown superficial 2nd degree burn with small blebs or bullae. However all 4 patients healed with scars. Mechanism of burn injuries of the denervated flap are known to be resulting from; 1) loss of behavioral protection due to denervation of flap with flap elevation and transfer, 2) loss of autonomic thermoregulatory control with heat dissipation on skin flap vasculature contributing to susceptibility of burn injury. 3) changes of immunologic and normal inflammatory response increasing thromboxane, and a fall in substance P & NGF (nerve growth factor). Including the abdominal flap donor site, sensory recovery of the reconstructed breast varies individually from 6 month even to 5 years postoperatively. During this period, wound healing is delayed, resulting in easier scarring compared to that observed in the sensate skin. Patients should be carefully informed and warned of possible burn injuries and taught to avoid exposure to heat source at least until 3 years postoperatively.

Clinical Characteristics of Thermal Injuries Following Free TRAM Flap Breast Reconstruction (횡복직근 유리피판술로 유방재건 후 발생한 화상의 임상적 특성)

  • Lee, Paik Kwon;Bae, Joon Sung;Ahn, Sang Tae;Oh, Deuk Young;Rhie, Jong Won;Han, Ki Taik
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.403-407
    • /
    • 2005
  • Following a transverse rectus abdominis musculocutaneous(TRAM) flap breast reconstruction, denervated state of the flap causes the flap skin prone to thermal injury, calling for special attention. During the last 5 years, 69 breast reconstruction with 72 free TRAM flaps, were performed. Four out of thesse 69 patients sustained burn injury. Heat sources were a warm bag(n=2), heating pad(n=1) and warming light (n=1). The thermal injuries occured from 2 days to 3 months following the reconstruction. Three patients healed with conservative treatment, but one patient required debridement and skin graft. Initially 3 out of 4 patients with the burn had shown superficial 2nd degree burn with small blebs or bullae. However all 4 patients healed with scars. Mechanism of burn injuries of the denervated flap are known to be resulting from; 1) loss of behavioral protection due to denervation of flap with flap elevation and transfer, 2) loss of autonomic thermoregulatory control with heat dissipation on skin flap vasculature contributing to susceptibility of burn injury. 3) changes of immunologic and normal inflammatory response increasing thromboxane, and a fall in substance P & NGF (nerve growth factor). Including the abdominal flap donor site, sensory recovery of the reconstructed breast varies individually from 6 month even to 5 years postoperatively. During this period, wound healing is delayed, resulting in easier scarring compared to that observed in the sensate skin. Patients should be carefully informed and warned of possible burn injuries and taught to avoid exposure to heat source at least until 3 years postoperatively.

Effect of retrograded rice on weight control, gut function, and lipid concentrations in rats

  • Ha, Ae-Wha;Han, Gwi-Jung;Kim, Woo-Kyoung
    • Nutrition Research and Practice
    • /
    • v.6 no.1
    • /
    • pp.16-20
    • /
    • 2012
  • The effects of retrograded rice on body weight gain, gut functions, and hypolipidemic actions in rats were examined. When the retrograded rice was produced by repetitive heating and cooling cycles, it contained significantly higher amounts of resistant starch ($13.9{\pm}0.98%$) than is found in common rice ($9.1{\pm}1.02%$) (P < 0.05). Sprague-Dawley rats were fed either common rice powder or retrograded rice powder, and mean body weight gain was significantly lower in the retrograded rice group (P < 0.05). The liver weight of the retrograded rice group ($14.5{\pm}0.5\;g$) was significantly lower than that of the common rice group ($17.1{\pm}0.3\;g$, P < 0.05). However, the weights of other organs, such as the kidney, spleen, thymus, and epididymal fat pad were not significantly affected by rice feeding. Intestinal transit time tended to be lower in rats fed retrograded rice when compared to rats fed the common rice, but the difference was not significant. The retrograded rice diet significantly increased stool output when compared to that in the common rice powder diet (P < 0.05), whereas fecal moisture content (%) was significantly higher in the retrograded rice group ($23.3{\pm}1.2$) than that in the common rice group ($19.1{\pm}1.2$) (P < 0.05). The retrograded rice group had significantly lower plasma cholesterol (P < 0.05), liver cholesterol (P < 0.05), and triacylglycerol contents in adipose tissue (P < 0.05) when compared to those in the common rice group. In conclusion, retrograded rice had higher resistant starch levels compared with those of common rice powder, and it lowered body weight gain and improved lipid profiles and gut function in rats.

Low-resistance ohmic contacts to p-$Hg_{0.7}$$Cd_{0.3}$Te (p-$Hg_{0.7}$$Cd_{0.3}$Te에 낮은 저항의 접촉을 얻는 방법에 대한 연구)

  • Kim, Kwan;Chung, Han;Kim, Sung-Chul;Lee, Hee-Chul;Kim, Choong-Ki;Kim, Hong-Kook;Kim, Jae-Mook
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.10
    • /
    • pp.87-93
    • /
    • 1994
  • Ohmic contacts between Au and p-HgHg_{0.7}Cd_{0.3}Te$ with low specific contact resistance have been obtained. The contact region of the wafer is first pre-heated for 5 seconds in a rapid thermal processing equipment. The temperature reaches a maximum value of about 200$^{\circ}C$ at the end of the 5 seconds. Next, a thin Au film is formed on the contact region by immersing the sample in AuCl$_{3}$ solution. the sample is then post-annealed in the same condition as the pre-heating after Pb/In pad metals are deposited on the electroless Au contacts. The specific contact resistance measured by transmission line model is 5${\times}10^{-3}{\Omega}cm^{2}$ at 80K. RBS and differential Hall measurement data suggest that the above low resistance ohmic contact is ascribed to surface traps and increased gold diffusion rate.

  • PDF

Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition (병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구)

  • Kang In-Seak;Choi Dong-Kyu;Kim Taig-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.