• Title/Summary/Keyword: Heating of agricultural facilities

Search Result 35, Processing Time 0.026 seconds

Heat Loss Audit and Assessment of the Greenhouses Using Infrared Thermal Image Analysis (적외선 열화상 분석을 통한 온실의 열손실 진단 및 평가)

  • Moon, Jong-Pil;Yun, Nam-Kyu;Lee, Sung-Hyoun;Kim, Hak-Joo;Lee, Su-Jang;Kim, Young-Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.2
    • /
    • pp.67-73
    • /
    • 2010
  • Unlike Urban building, horticultural facilities has a lot of heat loss through plastic or glass covering material which could be much influential to growing plant and consuming energy for heating greenhouse. In many cases, heat loss from a break of cover, a gap of joint sealing, the entrance to greenhouse and windows for ventilation are the main factors considered in calculating the heating load for horticultural facilities. however the normal observation through human eye and digital camera could not recognize where the heat loss occurred. but the infrared thermal image camera with detecting thermal difference could be very effective for noticing heat loss by analyzing infrared thermal image. In this study, greenhouse structure, covering material, internal and external provisions for Horticultural facilities were surveyed in different sites and Infrared thermal camera shooting and image analysis were performed for auditing heat loss from cultivation facilities The results from this study were that unexpected heat loss had been noticed in 7 representative cases of greenhouse such as side wall covered with single or double plastic, and the joint of horizontal thermal curtain, roof without horizontal thermal curtain, entrance to greenhouse, windows for ventilation. the most important factors for keeping heat energy were whether the horizontal thermal curtain with multifold thermal material was installed or not. The internal or external covering using multifold thermal curtain proved to be the most effective ways to keep heat energy from losing through heat transmission, heat radiation. from inside to outside the horticultural facilities.

The Effects of Renewable Energy in Agricultural Sector (농업분야 신재생에너지 보급현황 및 파급효과 분석)

  • Park, Jiyun;Kim, Yeonjoong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.224-235
    • /
    • 2019
  • The increase in the amount of energy used in the agricultural sector due to the expansion of agricultural machinery and greenhouse horticulture has caused a range of problems, such as an increase in the cost of input, such as heating costs and greenhouse gas emission. To overcome these problems, this study examined the current status of energy use in greenhouse horticulture as well as the change patterns of non-taxable oil and agricultural electricity, and reviewed the current status of the supply of renewable energy and energy saving facilities for agriculture. This study investigated the area of advanced and renewable energy and energy saving facilities implemented, applied the energy saving ratio of advanced and renewable energy and energy saving facilities, and determined the effects of renewable energy in the agricultural sector, such as increase in production, decrease in heating cost, reduction in Government financial expenditure, reduction in greenhouse gas emission, and oil substitution effect.

Thermal and Physicochemical Characteristics of Solid Fuel Extruded with Cattle Feedlot Manure (우분 성형 고형연료의 열 및 물리화학적 특성)

  • Lee, Gwi-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.35 no.1
    • /
    • pp.64-68
    • /
    • 2010
  • Cattle feedlot manure could be used effectively as the solid fuel for heating of agricultural facilities. Therefore, this study was carried out to investigate the thermal and physicochemical characteristics of solid fuel extruded with cattle feedlot manure. Calorific values of the solid fuel extruded with cattle feedlot manure, which was dried to the moisture contents of 0.0% (w.b) and 35.0% (w.b,) were 14,906 kJ/kg and 11,797 kJ/kg, respectively. Calorific value of extruded solid fuel was linearly decreased with the increase of moisture content. The first, second, and third reaction point during thermal pyrolysis of solid fuels extruded with cattle feedlot manure was investigated as $108.1^{\circ}C$, $312.2^{\circ}C$, and $459.4^{\circ}C$, respectively. The maximum reaction point was presented at the temperature of $312.2^{\circ}C$. Weight loss of extruded cattle feedlot manure during thermal pyrolysis until $600^{\circ}C$ was reached to about 60%. Volume decrease of initial extruded cattle feedlot manure was 61% during drying for the use as solid fuel. Maximum strength of extruded cattle feedlot manure, which was dried as the moisture content of 10% (w.b.) was 41,9150 N/$m^2$. Ignition gas analysis of extruded cattle feedlot manure presented that it has small amount of $NO_x$ and $SO_x$. It was shown that dried cattle feedlot manure had main components of C and O including small amount of Mg, Si, and Ca.

Study on Heating Load Characteristics and Thermal Curtain Effects for Simple Silkworm Rearing Houses(I) -Heating Load Coefficient and Maximum Heating Load- (간이잠실(簡易蠶室)의 난방(暖房) 부하특성(負荷特性) 및 보온(保溫)커튼 설치효과(設置効果)에 관(關)한 연구(硏究)(I) -간이잠실(簡易蠶室)의 난방(暖房) 부하계수(負荷係數) 및 최대(最大) 난방부하(暖房負荷)-)

  • Choe, K.J.;Lee, D.H.;Park, K.K.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.4
    • /
    • pp.346-354
    • /
    • 1990
  • In order to provide basic references for the design of heating on simple silkworm rearing house, the actual change of heating load coefficient by progress of adult silkworm rearing day from the reared in silkworm rearing house, the heating load coefficient by types of silkworm rearing houses and the heating requirement and the maximum heating load by types of silkworm rearing houses were determined. The results obtained from the study were as follows : 1. The average heating load coefficients of NS, OS and CC type simple silkworm rearing houses were $24.1KJ/m^2-hr-^{\circ}C$, $19.8KJ/m^2-hr-^{\circ}C$, and $10.8KJ/m^2-hr-^{\circ}C$, respectively. 2. The change of heating load coefficient by progress of silkworm rearing day after reared into simple silkworm rearing house could be expressed as Fig. 4. 3. Heating degree-hour for adult silkworm rearing in Suweon district was calculated as $951.6^{\circ}C-hr$ for spring season and $610.5^{\circ}C-hr$ for autumn season. 4. Yearly heating requirement of the NS type was estimated twice more than that of the CC type. Thus, some kinds of reinforced thermal adiabatic facilities is desirable for NS type. 5. The time for maximum heating load was turned out at the 4th instar during the spring season and after the mounting during the autumn season. 6. This study was performed in Suweon district. However, the estimated and analyzed data could be adapted to the major silkworm rearing district if their meteorology data were adjusted.

  • PDF

Prediction of Greenhouse Energy Loads using Building Energy Simulation (BES) (BES 프로그램을 이용한 국내 대표적 대형온실의 에너지 부하 예측)

  • Lee, Sung-Bok;Lee, In-Bok;Homg, Se-Woon;Seo, Il-Hwan;Bitog, P. Jessie;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Han, Chang-Pyoung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.3
    • /
    • pp.113-124
    • /
    • 2012
  • Reliable estimation of energy load inside the greenhouse and the selection of cooling and heating facilities are very important preceding factors to save energy as well as initial and maintenance costs of operating a greenhouse. Recently, building energy simulation (BES) technique to simulate a model similar to the actual conditions through a variety of dynamic simulation methods, and predict and analyze the flow of energy is being actively introduced and developed. As a fundamental research to apply the BES technique which is mainly used for analysis of general buildings, to greenhouse, this research designed four types of naturally-ventilated greenhouses using one of commercial programs, TRNSYS, and then compared and analyzed their energy load properties, by applying meteorological data collected from six regions in Korea. When comparing the greenhouse load of each region depending on latitude and topographical characteristics through simulation, Chuncheon had nearly 9~49 % higher heating load per year than other regions, but its annual cooling load was the reverse to it. Except for Jeju, 1-2W type greenhouses in five regions showed about 17 % higher heating load than a widespan type greenhouse, and 1-2W type greenhouses in Chuncheon, Suwon, Cheongju, Daegu, Cheonju and Jeju had 23 %, 20 %, 17 %, 16 %, 18 % and 20 % higher cooling load respectively than a wide span-type one. Glasshouse and vinyl greenhouse showed 8~11 % and 10~12 % differences respectively in heating load, while 2~10 % and 7~10 % differences in cooling load respectively.

Data Analysis for Structural Design of Pleurotus Eryngii Cultivation Facilities (큰느타리버섯 재배사의 구조설계용 자료 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.3
    • /
    • pp.29-37
    • /
    • 2005
  • This study was carried out to file up structural design data for optimizing Pleurotus eryngii growing houses. Design data are including current farm status of Pleurotus eryngii growing houses in the aspect of structural configuration as well as environmental conditions to be controlled and maintained inside. A structural analysis was performed for the on-farm structures as well as some structures modified and suggested through field survey and analysis. The results are summarized as follows. According to the results of status analysis, Pleurotus eryngii growing houses were categorized as arch-roofed simple type and sandwich panel type. Though the size of Pleurotus eryngii cultivation facilities were considerably diverse, the basic dimensions of Pleurotus eryngii cultivation facilities showed relatively similar pattern: more or less of 20m of length, $6.6\~7.0m$ of width, $4.6\~5.0m$ of peak height, $1.2\~1.6m$ of bed width, and 4 layers of bed. In the aspect of spatial use of cultivation facilities, suggested models were shown to be mostly reasonable in the aspect of heating and cooling, micro-meteorological stability, land use efficiency per unit floor area, etc.. Especially, the standard models suggested so far were thought to be not efficient in its surface area and spatial volume per unit floor area as well as its uneffective structural design in the area around ceiling. In the results of structural analysis for the models suggested through this study by using those section frames to be found on farms, the panel type structures of both single span and double span were estimated to be over designed, whereas arch-roofed pipe houses were mostly found to be under-designed.

Analysis of the Outdoor Design Conditions for Greenhouse Heating and Cooling Systems in Korea (온실의 냉난방시스템 설계용 외부기상조건 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.308-319
    • /
    • 2016
  • In order to set the outdoor weather conditions to be applied to the design standard of the greenhouse heating and cooling system, outdoor air temperature and heating degree-hour for heating design, dry bulb temperature, wet bulb temperature and solar irradiance for cooling design were analyzed and presented. For every region in Korea, we used thirty years from 1981 to 2010 hourly weather data for analysis, which is the current standard of climatological normal provided by KMA. Since the use of standard weather data is limited, design weather conditions were obtained using the entire weather data for 30 years, and the average value of the entire data period was presented as a design standard. The design weather data with exceedance probability of 1, 2.5, and 5% were analyzed by the TAC method, and we presented the distribution map with exceedance probability of 1% for heating and 2.5% for cooling which are recommended by design standards. The changes of maximum heating load, seasonal heating load and maximum cooling load were examined by regions, exceedance probabilities, and setpoint temperatures. The proposed outdoor design conditions can be used not only directly for the greenhouse heating and cooling design, but also for the reinforcement of heating and cooling facilities and the establishment of energy saving measures. Recently, due to the climate change, sweltering heat in summer and abnormal temperature in winter are occurring frequently, so we need to analyze weather data periodically and revise the design standard at least every 10 years cycle.

Economic Analysis of Pleurotus Eryngii Cultivation Facilities (큰느타리버섯 재배사의 경제성 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.6
    • /
    • pp.31-41
    • /
    • 2006
  • The analysis used in this work was cost-benefit analysis method. All future costs and returns of a given mushroom house were discounted to the time of initial investment (present) by means of 3.5% discount rate. Then the cost of ownership was compared to the return from the system. This analysis method has been developed and coded into a balance sheet for use on a EXCEL program. Using this programmed analysis,a large number of the case studies were examined using different combinations of economic conditions. These results will be very useful to individuals considering investment in a mushroom house, or any similar production system. By the way of the sensitivity analysis for each important parameter, the change of the marginal cost-benefit period could be finally determined. These parameters were typically construction cost of mushroom house, cost of cooling system, required cooling and heating energy amounts, unit price of mushroom media bottle, growing number of media bottles, production weight per unit bottle, sale price of mushroom, and annual number of growing period, etc.

Conceptual Directions of Village Community Center into a Rural Elderly's Welfare Service Space in Chonbuk Province (농촌 마을회관의 노인 복지서비스 공간으로의 활용 방안 - 평면과 이용행태 분석을 중심으로 -)

  • Choi, Byungsook;Park, Sunhee;Oh, Chanok;Hong, Chansun;Im, Sangbong
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.8 no.2
    • /
    • pp.80-93
    • /
    • 2006
  • This purpose was to explore various directions of elderly service welfare space in village community center. Data were collected 3 types that floor plans of village community centers from 24 villages, interview data of these centers use and needs from 24 aged leaders or 96 elderly. The results were as followed: 1) The floor plans of more than 50% was type IV that was composed a basic spaces(entrance, living room, two rooms, kitchen), a toilet space, a heating system space and a storage space. This type was a current basis of the rural village community centers for elderlies. 2) Elderlies used the centers at winter or out of agricultural season, and visited these to pass the time and to promote friendship among them. 3) Also they went these to take a meal together and to save down personal heating expenses. Their needs for centers were a temporary share dwelling space at winter, a maintain social relationship throughout a health, a education and a side work activity, supplying health or sports facilities, and setting up toilet space. Therefore the current centers were needed to add functions of a temporary share dwelling, a energy saving heat system and a social promoting relationship, and so these could be represented to a elderly welfare service center in rural villages.

  • PDF

An Estimation of the Acreage Response Function of Major Vegetables in Gyeongnam Province (경남지역 주요 채소류 재배면적 반응함수 추정)

  • Cho, Jae-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.131-137
    • /
    • 2021
  • This study estimated acreage response functions for greenhouse paprika, greenhouse strawberry, open-land garlic, and open-land spinach by using Gyeongsangnamdo agricultural income data. The results show that the cultivation area for greenhouse paprika increased because the agricultural management costs decreased, and the risk of price volatility was relatively low. On the other hand, the cultivation area for greenhouse strawberries decreased due to increasing agricultural management costs and the greater risk of price volatility. In the case of open-land garlic and spinach, the cultivation area remained stagnant due to the greater risk of price volatility, despite increasing agricultural revenue. We derived several policy implications from our results. The risk of price volatility in agricultural products is greater for crops grown on land rather than crops grown in greenhouses. Therefore, the local government needs to adopt the "agricultural revenue guarantee insurance" in preference to crops grown on land rather than crops grown in greenhouses. On the other hand, in the case of greenhouse crops, agricultural management costs are very high. Thus, local government should focus on replacing old facilities and supplying smart-farm facilities that reduce agricultural management costs such as heating costs.