• 제목/요약/키워드: Heating gun

검색결과 142건 처리시간 0.025초

수산소 혼합가스를 이용한 선상가열 특성 (The Characteristics of Line Heating Using Hydrox Gas)

  • 김홍건;곽이구
    • 한국생산제조학회지
    • /
    • 제20권4호
    • /
    • pp.407-411
    • /
    • 2011
  • The technology of line heating has evolved in various methods. Among them, fossil fuels like ethylene gas and LPG(Liquid Petroleum Gas) are widely used due to their simple utility. In the meantime, the technology implementing high frequency for line heating has also been developed continually, but its manufacturing technology or application includes lots of problems by now. One of the main characteristics of line heating using conventional technolob'Y is the quenching effect followed by heating process. On the other hand, hydrox gas which is mixed by hydrogen and oxygen is a prominent candidate for an application without above shortcomings. Especially, it is found that line heating using hydrox gas is tremendously effective taking low cost as well as low noise. In this paper, a small cell with high efficiency which can minimize installing space is developed to deal with the problem installing in narrow place. Experiments to prove the validation, efficiency and effectiveness is carried out by characterizing in the line heating of steel. It is found that the energy saving of using hydrox gas for line heating is significant and that the deviation performance is reduced by 78~89%. Furthermore, the noise is also reduced as amount of 18.3% though the heating time is not too different.

유도가열 시스템을 위한 새로운 전류형 풀-브릿지 공진형 인버터 설계 (Design of New Current Full-Bridge Resonant Inverter for Induction Heating System)

  • 이상훈;임상길;송성근
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.59-69
    • /
    • 2012
  • There are two types of inverters that are generally used in induction heating systems: voltage type inverters and high-frequency half-bridge inverters. This paper proposes a new resonant inverter for induction heating systems using the current type full-bridge method. The proposed method can remove capacitors at the input end, and enables unity power factor operation by preventing phase differences of voltage and current. Furthermore, Zero Voltage Switching (ZVS) which is in tune with current type inverter can be adopted and continuous power adjustment is possible through duty ratio changes and frequency modulation in switching operation. Simulations and experiments showed that the proposed current type full-bridge resonant inverter could be used for unity power factor control and ZVS operation in induction heating systems.

반복전기공급에 따른 발열모르타르의 발열 특성 (Heat generation characteristics of the heating mortar according to repeated electricity supply)

  • 김영민;임창민;권현우;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.170-171
    • /
    • 2022
  • In recent years, due to the occurrence of traffic accidents caused by black ice in winter, the number of personal injuries is increasing rapidly. Black ice is a phenomenon that occurs like a thin layer of ice on the road surface. Accordingly, many developments of heat-generating concrete are being developed to remove ice by increasing the temperature by supplying constant electricity to places where black ice is likely to occur. These heating elements are being developed by mixing a conductive material represented by carbon nanotubes with concrete. However, research up to now has been focused on efficient temperature rise and derivation of the optimum mixing ratio, and the evaluation of maintaining heat generation performance during continuous repetition is insufficient. Therefore, in this study, a heating test specimen was manufactured and 50V power was repeatedly supplied to evaluate the heating characteristics.

  • PDF

Employing high-temperature gas flux in a residual salt separation technique for pyroprocessing

  • Kim, Sung-Wook;Heo, Dong Hyeon;Kang, Hyun Woo;Hong, Sun-Seok;Lee, Sang-Kwon;Jeon, Min Ku;Hur, Jin-Mok;Choi, Eun-Young
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1866-1870
    • /
    • 2019
  • Residual salt separation is an essential step in pyroprocessing because its reaction products, as prepared by electrochemical unit processes, contain frozen residual electrolyte species, which are generally composed of alkali-metal chloride salts (e.g., LiCl, KCl). In this study, a simple technique that utilizes high-temperature gas flux as a driving force to melt and push out the residual salt in the reaction products was developed. This technique is simple as it only requires the use of a heating gun in combination with a gas injection system. Consequently, $LiNO_3-ZrO_2$ and $LiCl-ZrO_2$ mixtures were successfully separated by the high-temperature gas injection (separation efficiency > 93%), thereby demonstrating the viability of this simple technique for residual salt separation.

800℃ 조건에서의 시멘트 경화체의 균열 특성 (Cracking Behavior of Cement and Concrete Damaged by High Temperature of 800℃)

  • 지우람;박지웅;신기돈;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.26-27
    • /
    • 2017
  • In this study, the cracking characteristics of cured pastes at 800℃ were investigated by X-ray CT. The test specimens were fabricated with and without aggregate, and the heating rate condition was applied at rapid heating (10.0℃/min). It is considered that the rapid heating condition does not cause a temperature gradient phenomenon because the temperature difference between the surface and the center of the sample is small due to a low heating rate unlike an actual fire. The cracking condition of the specimens without aggregate was more severe than that of specimens with aggregate.

  • PDF

Estimation of nuclear heating by delayed gamma rays from radioactive structural materials of HANARO

  • Noh, Tae-yang;Park, Byung-Gun;Kim, Myong-Seop
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.446-452
    • /
    • 2018
  • To improve the accuracy and safety of irradiation tests in High flux Advanced Neutron Application ReactOr (HANARO), the nuclear energy deposition rate, which is called nuclear heating, was estimated for an irradiation capsule with an iridium sample in the irradiation hole in order. The gamma rays emitted from the radioisotopes (RIs) of the structural materials such as flow tubes of fuel assemblies and heavy water reflector tank were considered as radiation source. Using the ORIGEN2.1 code, emission rates of delayed gamma rays were calculated in consideration of the activation procedure for 8 years and 2 months of HANARO operation. Calculated emission rates were used as a source term of delayed gamma rays in the MCNP6 code. By using the MCNP code, the nuclear heating rates of the irradiation capsules in the inner core, outer core, and heavy water reflector tank were estimated. Calculated nuclear heating in the inner core, outer core, and heavy water reflector tank were 200-260 mW, 80-100 mW, and 10 mW, respectively.

산림바이오매스 이용 마을단위 지역난방에 관한 주민 인식 분석 - 화천 산림탄소순환마을 사례를 중심으로 - (An Analysis of Residents' Perception on District Heating in the Village Unit Using Forest Biomass - Focused on the Case of Forest Carbon Circulation Village in Hwacheon -)

  • 유선화;김성학
    • 한국환경과학회지
    • /
    • 제29권4호
    • /
    • pp.339-349
    • /
    • 2020
  • This study aims to identify participating resident awareness of the improvements to forest carbon cycle villages created by the Korea Forest Service by introducing a system for district heating basedon forest biomass in mountainous areas. Hwacheon Forest Carbon Circulation village was established in Paroho-neureup village in Yuchon-ri, Hwacheon-gun between 2011 and 2013. However, its operation has not been smooth due to the increasing number of households rapidly leaving the district heating system. This study surveyed 76 households that participated in the district heating system using forest biomass in the early stages of the project. This includes households participating in the district heating system(participating households) and households not currently participating in the district heating system(withdrawal households) from September 2019. Surveys focused on the process of participating in forest carbon cycle village projects, and satisfaction in local heating and policy requirements. Of the 67 households, excepting those not allowed to participate in the survey due to death or having moved elsewhere, 36 households participated and 31 households the were in the process of leaving the village were also included. As a result, there was a significant difference between participating and exiting households in the motivation and satisfaction level of district heating. The results of this study are expects to reflect the importance of awareness of residents in the operation of the forest carbon cycle village. This will be utilized as an important dataset for improvement as a means to promote the re-entry if outgoing households. It will also help set the direction of the forest town revitalization project, utilizing forest biomass in the future.

마을회관의 태양열 시스템적용에 관한 연구 -경상북도 영양군 입암면을 중심으로- (A Study on the Application Solar Heating System of Village Hall)

  • 유인호
    • 한국산업융합학회 논문집
    • /
    • 제13권3호
    • /
    • pp.145-151
    • /
    • 2010
  • This study is for getting basic data through grasping the obtained heat by structure of each unit and the effects of environment improvement based on judgement for whether or not a solar heating system of renewable energy installations is possible to set up in village hall public buildings as community center and senior citizen center. Conducting a survey of community center and senior citizen center in Ibam-Myon, Yeongyang-Gun, Gyeongsangbuk-Do and the analysis, obtained solar heat of 414,309,678 kcal every year and from this, effects of 131.48995 $TCO_2$. These figure equate to 26,298 pines effect. These results show that the advantage of reducing building operating costs in the long run besides effects of environment improvement.

  • PDF

Heating and Cooling Energy Conservation Effects by Green Roof Systems in Relation with Building Location, Usage and Number of Floors

  • Son, Hyeong Min;Park, Dong Yoon;Chang, Seong Ju
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.11-19
    • /
    • 2014
  • Building energy consumption takes up almost 25% of the total energy consumption. Therefore, diversified ways, such as improving wall and window insulation, have been considered to reduce building energy consumption. Recently, green roof system has been explored as an effective alternative for dealing with reducing heating and cooling energy, thermal island effect and improving water quality. However, recent studies regarding a green roof system have only focused on building energy reduction without considering the applied usage, location, and story of the green roof system. Therefore, this study pays attention to the heating and cooling energy in relation to the applied usage, location, and story of a green roof system for investigating its impact on energy reduction. The result of simulations show that the reduction in heating energy consumption is higher when applied to Cherwon-gun province which has a continental climate condition, compared to the city of Busan that is distinguished by its warm climate. Cooling energy saving turns out to be higher when the green roof system is applied to Busan in comparison with Cherwon. As for the applied usage or function of the building, residential space acquires the highest heating and cooling energy saving effect rather than commerce, educational or office space because of HVAC's running time based on usage. When it comes to the story of the green roof, both heating and cooling energy saving become the highest when the green roof is applied to single-storied buildings. The reason is that single story building is affected by the ground largely. Generally, the variations of heating energy consumption are larger than the cooling energy consumption. The outcome of the simulations, when a green roof system is applied, indicates that the energy consumption reduction rate is dynamically responding to the applied usage, location, and story. Therefore, these factors should be counted closely for maximizing the reduction of energy consumption through green roof systems.

강원 영동지역의 관광철 폐기물 및 발열량 특성 (Characteristics of Municipal Solid Wastes and Heating Value in Tourist Season of the eastern side of Gangwondo)

  • 이해승;최용범
    • 환경위생공학
    • /
    • 제21권1호
    • /
    • pp.66-75
    • /
    • 2006
  • When we looked at the seasonal food dregs of the eastern side of gangwondo, gangneung city's summer and winter food dregs showed 25.9 and 25.8% respectively due to the presence of beach areas and ski resorts. Sokcho city showed 28.12% in summer and yangyang gun's summer food dregs showed 40.2%. Yangyang gun's august food dregs showed 2.7 times larger than annual average amount. Outlook density showed regional characteristics. Data showed that food dregs' amount rate has been reduced gradually from 2005 because of the prohibition of direct filling up. As a result of compositions analysis, the eastern side of gangwondo's water fraction of living dregs were lower than that of chuncheon city where is located at the gangwondo's inland area. chuncheon city's data showed residential areas 53.5%, community areas 56.8% and commercial areas 55.6%. These discrepancies caused by the characteristics of dregs discharge type and climate. The caloric value of dregs has been increased incrementally after the ban of food dregs' direct filling up. Therefore, heating value of the dregs exceeds the existing furnace design spec and it can cause high caloric value problems, so we need additional research to solve these problems.