• 제목/요약/키워드: Heating cooling load

검색결과 384건 처리시간 0.023초

표준기상데이터(부산지역) 비교 및 분석 (Analysis of Building Energy by the Typical Meteorological Data)

  • 유호천;이관호;강현구
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.13-18
    • /
    • 2009
  • Building is a major energy consumer, and now many efforts are made to save energy in the design and using equipments. The most noticeable achievement in those efforts is a building energy performance assessment program. But most programs are not satisfying enough to provide exact meteorological data, and data source and calculation, and data collection period are not clearly defined. That is common in most of domestic programs. This study collects typical meteorological data in 16 items and analyzes them with Visual DOE 4.0 to compare with existing data. The comparison found that revised data shows a 11% increase on average during cooling period from June to September, and a 13% decrease on average during heating period from December to February, in terms of building heating and cooling load in a monthly basis.

  • PDF

지열 이용 열펌프 시스템의 열성능 해석 (Analysis of Thermal Performance of Ground-Source Heat Pump System)

  • 고득용;신우철;백남춘;김욱중
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.167-172
    • /
    • 2005
  • The purpose of this study is to present the simulation results and an overview of the performance assessment of the Ground-Source Heat Pump(GSHP) system. The calculation was performed for two design factors. the spacing between boreholes and the depth of the vertical ground heat exchangers. And the simulation was carried out using the thermal simulation code TRNSYS with new model o( water to water heat pump developed by this study. As a result, it was anticipated that the yearly mean COPs of heat pump for heating and cooling are about 3.7 and 5.8 respectively and the heat pump can supply 100% of heating and cooling load all the year around.

  • PDF

개방형 지중열교환기 용량 설계 방법에 관한 연구 (Study on the Capacity Design Tool Development for Open-loop Ground Heat Exchanger)

  • 류형규;최승혁;윤희원;김유승
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.9-15
    • /
    • 2017
  • When applying geothermal systems in cities such as seoul where high density development prevails, the selection of geothermal system capable of obtaining a large capacity in the limited grounds is necessary. In this study, an easy-to-use design tool is developed in the form of spreadsheet by applying the calculation theory of existing closed-loop vertical ground heat exchanger that can be used in the early design stage of the open-loop ground heat exchanger. By only using the maximum cooling and heating load, it is possible to calculate optimal design open-loop ground heat exchanger. Further research is needed, we are plan to improve the program considering the heat loss of groundwater flowing in the inner casing, G-Function for Open-Loop, and verification by applying actual projects.

학교 건물에 설치된 지열원 열펌프 시스템의 실사용을 통한 냉난방성능 연구 (Cooling and Heating Performance Under the Actual Operating Condition of a Ground Source Heat Pump System in a School Building)

  • 김의영;정영만;송재도;이재근;김인규;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.586-589
    • /
    • 2009
  • This paper presents the performance of a water-to-refrigerant type ground source heat pump (GSHP) system installed in a school building in Korea. For analyzing the performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the input power of the GSHP system. The average cooling coefficient of performance (COP) of the heat pump was found to be 8.5 at 60% partial load condition, while the overall system COP was found to be 5.9. The average heating COP of the heat pump was found to be 6.5 at 45% partial load condition, while the overall system COP was found to be 5.0.

  • PDF

실내조명의 발열량 예측에 관한 실험 연구 (The Performance of generated Heating Energy from Interior Lighting Fixtures)

  • 최종선;임홍수;김경아;이금환;구재오;김곤
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.27-32
    • /
    • 2010
  • Approximately 20 percentage of energy consumptions in buildings is consumed as lighting energy. Thus, most of the corporations of lighting fixture have launched low energy products. However, many researchers focused on the only luminous efficacy for energy conservation and used the evaluating tool of study. This can not gauge the precise cooling load related on generated heat of artificial lighting. In order to assess an effect of the temperature variation of lighting resources, the main purpose of this study is to predict the generated heating energy from lighting by measuring the thermal variation in scale model to reduce external noise. Also this paper used MX100 data logger to record at an interval of 1 minute for 60 minutes for the temperature of interior lightings such as incandescent lamp, fluorescent light, halogen lamp and LED lamp. As a result, LED lamp generated the lowest heat. On the other hand, incandescent lamp did the highest.

실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석 (A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds)

  • 현인탁;이재호;윤여범;이광호
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.

수평형 지중열교환기를 이용한 건물일체형 지열시스템의 도입타당성 분석 (The feasibility study for the building integrated geothermal system using the horizontal heat exchanger)

  • 채호병;남유진;윤성훈
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.81-87
    • /
    • 2015
  • Recently, in order to prevent increasing energy usages in the international community, many countries have attempted to develop the innovative renewable energy systems. Among the renewable energy systems, Ground source heat pump(GSHP) system which supply the heating, cooling and hot water in the building has been attracted by its stability of heat production and high efficiency. However, the initial drilling costs become very expensive and the construction period takes longer the other systems, because GSHP system needs more than 100 m depth drilling. In this study, in order to reduce initial costs of the GSHP, the building integrated geothermal system using the horizontal heat exchanger was developed. The heating and cooling load in the standard housing model was calculated by a simulation and the system design capacity in the high-rise apartment was decided by the total load. Based on the system design capacity, the high-rise apartments were applied to a BIGS and vertical GSHP system and there are analyzed about initial costs. In the result, the initial cost of BIGS could reduce 24% of the initial cost of the vertical GSHP system.

시뮬레이션을 통한 실내 오염물질 확산의 예측 방법 (A Prediction of the Indoor Contaminant diffusion using Network Simulation)

  • 강기남;송두삼
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.311-318
    • /
    • 2006
  • CFD simulation is a tool very useful to predict the generation and absorption of the contaminant from the construction materials for the single room condition. However, there is a limit in multi-room simulation for analyzing air movement and contaminant concentration at the condition that the door of each room was closed. A lot of network simulation tool were developed which can used to analyze the mass transfer and contaminant concentration as results in the multi-room condition. However, existing network simulation method was not able to analyze the change of the heating and cooling load with the ventilation as though the change of the indoor air-pollution density was predictable. In this study, new approach to predict heating/cooling load and indoor contaminant concentration will be reviewed. New indoor contaminant concentration module reviewed in this study wad coupled with existing ESP-r network simulation method. The validity of new approach will be analysed for comparison the results of simulation and field measurement results.

  • PDF

Analysis of restrained steel beams subjected to heating and cooling Part II: Validation and parametric studies

  • Guo, Shi-Xiong;Li, Guo-Qiang
    • Steel and Composite Structures
    • /
    • 제8권1호
    • /
    • pp.19-34
    • /
    • 2008
  • This paper presents the results of a validation and parametric study for the theory presented in the companion paper. The parameters investigated include the stiffness of axial and rotational restraints, load ratio, depth-span ratio of the beam, the yield strength of steel, load type and the temperature distribution in the crosssection of the beam.

온도와 부하의 비선형성을 이용한 단기부하예측에서의 TAR(Threshold Autoregressive) 모델 (TAR(Threshold Autoregressive) Model for Short-Term Load Forecasting Using Nonlinearity of Temperature and Load)

  • 이경훈;이윤호;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권9호
    • /
    • pp.399-399
    • /
    • 2001
  • This paper proposes TAR(Threshold Autoregressive) model for short-term load forecasting including temperature variable. In the scatter diagram of daily peak load versus daily high or low temperature, we can find out that the load-temperature relationship has a negative slope in the lower regime and a positive slope in the upper regime due to the heating and cooling load, respectively. TAR model is adequate for analyzing these phenomena since TAR model is a piecewise linear autoregressive model. In this paper, we estimated and forecasted one day-ahead daily peak load by applying TAR model using this load-temperature characteristic in these regimes. The results are compared with those of linear and quadratic regression models.