• 제목/요약/키워드: Heating control

검색결과 1,581건 처리시간 0.028초

강판의 곡가공 자동화를 위한 수치제어 시스템의 개발 (Development of Numerical Control System for Plate forming Automation)

  • 이주성
    • 한국해양공학회지
    • /
    • 제17권1호
    • /
    • pp.72-79
    • /
    • 2003
  • This paper deals with the development of an interface program for automatic plate forming, which can exchange information between the heating line information generation program and the automatic heating apparatus. In this paper, the performance of the developed interface program has been verified from the view point of numerical position control. By applying the interface program to the operation of the automatic heating apparatus, an experiment of line heating has been conducted for several steel plate models. Based on the experimental results, a simplified relation to estimate angular distortion has keen derived as a natural characteristic of the present automatic heating apparatus. As a result of the present study, the prototype of the automatic plate forming system has been constructed, and its application to the real surface models found in the ship will be presented in the near future.

주거용건물의 바닥복사 난방방식에 대한 실태조사 연구 (Research on the actual condition of 'Under Floor Radiant Heating for Apartment Housing')

  • 우병관;이성;김삼열
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.81-86
    • /
    • 2007
  • The research analyzes the arrangement of boiler and hot water header, the method of radiator pipe setting, hot water supply control, hourly heating situation of each room for underfloor radiant heating systems in Korea and suggests an alternative to improve to efficient heating method. One of the best options for install position of hot water distributor is under kitchen sink which is center point of all rooms, according to previous research of the energy saving strategies. When the radiator pipes are arranged to each individual room instead of bedrooms through livingroom and kitchen, it has energy saving effects. For rooms without occupancy according to a time period, hot water supply method should be intermittent heating rather than continuous heating. For this intermittent heating method, individual control of hot water supply is more practical, and it can lead to massive energy savings. The intermittent heating system has time-lag, so it is more effective in energy saving with mild and comfort condition if the spaces are preheated by automatic control equipment prior to required time.

매설용 전기 발열 매시의 융설 효과에 대한 현장 적용성 연구 (A Study on Field Applicability of Underground Electric Heating Mesh)

  • 서영찬;서병석;송중곤;조남현
    • 한국도로학회논문집
    • /
    • 제15권2호
    • /
    • pp.19-27
    • /
    • 2013
  • PURPOSES : This study aims to investigate the snow-melt effects of an underground electric heater's snow-melt system via a field performance test, for evaluating the suitability of the system for use on a concrete pavement. The study also investigates the effectiveness of dynamic measures for clearing snow after snowfall events. METHODS : In order to check the field applicability, in November 2010, specimens were prepared from materials used for constructing concrete pavements, and underground electric heating meshes (HOT-mesh) were buried at depths of 50 mm and 100 mm at the site of the Incheon International Airport Construction Research Institute. Further, an automatic heating control system, including a motion sensor and pavement-temperature-controlled sensor, were installed at the site; the former sensor was intended for determining snow-melt effects of the heating control system for different snowfall intensities. Pavement snow-melt effects on snowy days from December 2010 to January 2011 were examined by managing the electric heating meshes and the heating control system. In addition, data on pavement temperature changes resulting from the use of the heating meshes and heating control system and on the dependence of the correlation between the outdoor air temperature and the time taken for the required temperature rise on the depth of the heating meshes were collected and analyzed. RESULTS : The effects of the heating control system's preheat temperature and the hot meshes buried at depths of 50 mm and 100 mm on the melting of snow for snowfalls of different intensities have been verified. From the study of the time taken for the specimen's surface temperature to increase from the preheat temperature ($0^{\circ}C$) to the reference temperature ($5{\sim}8^{\circ}C$) for different snowfall intensities, the correlation between the burial depth and outdoor air temperature has been determined to be as follows: Time=15.10+1.141Depth-6.465Temp CONCLUSIONS : The following measures are suggested. For the effective use of the electric heating mesh, it should be located under a slab it may be put to practical use by positioning it under a slab. From the management aspect, the heating control system should be adjusted according to weather conditions, that is, the snowfall intensity.

인버터 타입 오일냉각기의 온도제어 특성에 관한 연구 (Characteristics of Temperature Control in the Inverter Type Oil Coolers)

  • 이상호;이찬홍;박천홍
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.233-236
    • /
    • 2003
  • In this Paper, the temperature control error and cooling characteristics of inverter typ coolers are evaluated to predict application validity of coolers under heating pattern and amount The temperature control error of coolers small in 15~70% range of the max. cooling ability. At less than 15% of max. cooling ability has the inverter type cooler a basic temperature control error $\pm0.5^{\circ}C$ and acts as on/off type coolers. The inverter type cooler is unsuitable for precision temperature control under the complex heating pattern. But PID control of cooler including the heating system is an alternative for the case.

  • PDF

바닥 복사난방 시스템의 실내온도 제어방안에 관한 시뮬레이션 연구 (Simulation Study for Control Strategies of Indoor Air Temperature in Floor Radiant Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.21-26
    • /
    • 2016
  • In this study, the control strategies of indoor air temperature in floor radiant heating system were researched by computer simulation. The temperature difference based time control method using the difference of indoor set temperature and indoor temperature is compared with the existing On-Off control one for heating control performances. As a result, the temperature difference based time control method shows better thermal environmental characteristics in case of selected operational conditions in comparison with existing control one.

선상 가열을 위한 고주파 유도 가열의 수치 해석 (Numerical analysis of induction heating for the application of line heating)

  • 강중규;이장현;신종계
    • 대한조선학회논문집
    • /
    • 제37권3호
    • /
    • pp.110-121
    • /
    • 2000
  • 선상가열의 열원으로는 가스 가열법, 고주파 유도 가열법, 그리고 레이저 가열법 등이 사용될 수 있다. 가스 가열법은 많은 조선소등에서 사용되고 있으나 가열 후 얻어지는 잔류변형을 제어하는데 많은 어려움이 있다. 고주파 유도 가열법은 비교적 정확한 변형량 제어가 가능하다는 장점을 가지고 있어서 새로운 선상가열 열원으로서 활용될 수 있을 것이다. 본 연구에서는 고주파 유도가 열법을 이용한 선상 가열의 변형 특성 및 가열장치의 특성을 파악하기 위한 기본단계로써 고주파 유도가열에 의한 열변형 과정에 대한 해석을 시도하였다. 전자장 해석과 와전류 해석, 와전류에 의하여 판에 발생하는 온도 분포, 그리고 열탄소성 변형 해석을 수행하였다.

  • PDF

3방 비례제어 조절밸브 개발 및 성능 연구 (Development of Three-Way Proportional Control Valve and Performance Study)

  • 이종화;정택수;조종두;김주용
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.218-223
    • /
    • 2014
  • Korea District heating corp. recently give an attention to combine the district heating and supply pipes as a two pipe system that are in the present system separated with room heating and warm water supply pipe, and the two pipe system is commonly applied for heating service in European countries. In the new two pipe system, only one heat source is supplied to a house and partitioned into room heating and warm water supply by household substation. So the effective distribution of supplied heat source in accordance to user intention is very important. This paper presents the development and performance test of three-way proportional control valve for a combined heat source system in district heating. The proposed valve is controlled to partition heat source into two different directions : hot water distributor for space heating and household substation for warm water supply in response to the pressure drops of tap water caused by the user. The performance investigation is shown within 3% of error compared to the theoretical model of the three-way proportional valve and its controllability is verified.

Induction Heating PWM High Frequency Inverter using New Active Auxiliary Resonant Snubber

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Kim, Hong-Sin;Jung, Sang-Hwa;Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제22권3호
    • /
    • pp.40-51
    • /
    • 2008
  • This research presents a new active auxiliary resonant snubber with for induction heating PWM high frequency inverter solving the problem of induction heating PWM high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the active auxiliary resonant snubber with for induction heating PWM high frequency inverter. The inverter circuit which is attempted by the on-off operation of a switch has the effect of reducing the power loss due to soft switching and high frequency switching. This confirms that power regulation is possible on a continuous basis from 0.25[kW] to 2.84[kW] where the duty factor(D) changes from 0.08 to 0.3 under zero current switching which operates by an asymmetrical pulse width modulating control. The power conversion efficiency is 95[%]. Due to these results, the active auxiliary resonant snubber for an induction heating PWM high frequency inverter is considered effective as a source of induction heating.

긴 지연시간을 갖는 온수난방 제어시스템의 디지틀 가변구조제어 (Digital variable structure control of a hot-water heating control system with long dead time)

  • 안병천;장효환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.232-237
    • /
    • 1991
  • Digital Variable Structure Controller(DVSC) is proposed to control variable speed recirculating pump for hot-water heating control system. In this study, nonlinear sliding line is used beyond output error boundary layer and PID sliding line is used within the layer. For long dead time compensation, constraint is added to Smith predictor algorithm. Steady state error is eliminated by using the proposed sliding line in spite of heating load change. By decreasing sampling time, good sliding motion is yielded but system output noise bv flow dynamics is amplified.

  • PDF

밸브제어기용 전력선 통신 모뎀을 이용한 에너지 절약형 난방제어 시스템 (Energy Saving Heating Control System Using the Power Line Communication Modem for a Valve Controller)

  • 김명호;이태봉
    • 전기학회논문지P
    • /
    • 제55권3호
    • /
    • pp.123-127
    • /
    • 2006
  • In a heating control system, the indoor temperature controller transfers temperature signals inputted from the temperature sensor and the user to the valve controller. The valve controller receives these signals then the valve controller controls the valve driving motor on two position control and controls the indoor temperature. When setting up a new valve driving motor from a long distance it is necessary to set up a new valve controller. But occasionary, due to construction, It is impossible to wire between the existing valve controller and the new valve controller. In this situation, the new and existing valve controllers can communicate via power line communication. In this paper it is proposed heating control system controls on two position control via power line communication.