선풍기의 운전 상황별 발열특성 및 전류신호 검출 (Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations)

  • 김두현;이흥수
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.

전자유도가열용 Full-Bridge 고주파 공진형 인버터의 개발 (Development of Full-Bridge High-Frequency Resonant Inverter for Electromagnetic Induction Heating)

  • 권혁민;신대철;김용주;김기환
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2943-2946
    • /
    • 2003
  • In this paper are described the indirect induction healed boiler and induction boated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20[kHz]to 50[kHz]. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

Full-Bridge 고주파 공진형 인버터를 이용한 유도가열시스템의 개발에 관한 연구 (A Study on the Development of Induction Heating System for Using Full-Bridge High-Frequency Resonant Inverter)

  • 권혁민;김성호;신대철;김용주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.19-22
    • /
    • 2003
  • In this paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20 [kHz] to 50 [kHz]. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

석유팬히터 기화기내 유동장 해석 (Numerical Analysis of Kerosene Burner)

  • 홍용주;심성훈;김인규;김영수
    • 연구논문집
    • /
    • 통권27호
    • /
    • pp.109-118
    • /
    • 1997
  • Kerosene Burner has widely used in domestic heating appliance. Higher combustion efficiency is required to save fuel and clean exhaust gas. The combustion characteristics in kerosene burner highly depends on the performance of evaporating liquid kerosene. And performance of evaporating effect on generation of tar. In this study, flow and heat transfer of kerosene burner is simulated by FLUENT/UNS using unstructured mesh system and discrete phase model to analyze performance of evaporating kerosene liquid. The simulated results show very complicated flow pattern and back flow at the exit of burner.

  • PDF

간접유도가열용 고주파 공진형 인버터 시스템에 관한 연구 (A Study on the High-Frequency Resonant Inverter System for Indirect Induction Heating)

  • 권혁민;신대철;김기환;김용주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.322-325
    • /
    • 2002
  • In this paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20kHz to 50kHz. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted Into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

Experimental and Theoretical Studies on the Dynamic Characteristics During Speed Down of Inverter Heat Pump

  • Hwang, Yoon-Jei;Kim, Ho-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권1호
    • /
    • pp.29-39
    • /
    • 2000
  • A series of tests were performed to verify the transient characteristics of heat pump in heating and cooling mode when operating speed was varied over the 30 to 102Hz. One of the major issues that has not been addressed so far is transient characteristics during speed modulation. The model for cycle simulation has been developed to predict the cycle performance under conditions of decreasing drive frequency and the results of the theoretical study were compared with the results of the experimental study. The simulated results were in good agreement with the experimental result within 10%. The transient cycle migration of the liquid state refrigerant causes significant dynamic change in system. Thus, the migration of refrigerant was the most important factor whenever do experimental results analysis or develop simulation model.

  • PDF

전압형 고주파 인버터를 이용한 간접유도가열 열유체 에너지시스템과 그 성능평가 (Electromagnetic Indirect Induction Fluid Heating System using High-Frequency Inverter and Its Performance Evaluations)

  • 김용주;신대철;김기환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.483-486
    • /
    • 2001
  • This Paper the state-of-the art indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter whice can operate in the frequency range from 20kHz to 50kHz. A specially-designed induction heater composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates is inserted into the ceramic type vessel with external working coil connected to the inverter and tubelence fluid through this induction heater in moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

가정용 비상 전원 절체 모듈 개발 (A Development of Energency Power Automatic Transfer Module in home)

  • 주남규;김관영;김남호;이종명
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.321-323
    • /
    • 2009
  • When power failure occurs at multi-housing complex, auxiliary generator or emergency generator starts to provide power to households. This power is connected to emergency power ELB(Earth Leakage Breaker) at home distribution panel board and supplies power only for emergency light in living room but for heating system, refrigerator and other inevitable apparatuses that are in need of uninterruptible power. Since those domestic appliance are fed from common power line, they are inoperable during power failure. Our research is to resolve this problem by developing compatible relay-drive common/emergency-power ATS (automatic transfer switch) for home distribution panel board. In case of power failure, it transfers automatically and commences to provide power from emergency generator. Through this, Consumers can reach satisfaction where common power loads operate without any problem under both ordinary and power failure condition.

  • PDF

디젤오염토양의 TPH 분해를 위한 마이크로파의 가열특성 (Enhanced TPH Degradation of Diesel-Contaminated Soil by Microwave Heating)

  • 정병길;김대용;김정권
    • 한국환경과학회지
    • /
    • 제17권5호
    • /
    • pp.479-484
    • /
    • 2008
  • The application of microwave technology has been investigated in the remediation of diesel-contaminated soil. The paper deals with economic assessment by means of cost analysis and degradation characteristics at different microwave powers for total petroleum hydrocarbon (TPH) in diesel contaminated soils. The soils from S Mountain around the D University were sampled. The samples were screened with 2.0 mm mesh and dried for 6 hours before the diesel was added into the dried soils. The diesel-contaminated soil (3,300 mg THP/kg soil) was prepared with diesel (S Co.). The drying process was carried out in a microwave oven, a standard household appliance with a 2,450 MHz frequency and 700 W of power. The experiments were conducted from 0 to 20 minutes as the microwave powers increased from 350W to 500W to 700W. The concentrations of TPH were analysed using a gas chromatography/mass spectrometer (GC/MS). The initial concentration of TPH was 3,300 mg TPH/kg soil. The weight of contaminated soil was 200g. The concentration of TPH was decreased to 1,828 mg TPH/kg soil (44.7%), 1,347 mg TPH/kg soil (59.2%) and 1,014 mg TPH/kg soil (69.3%) at 350W, 500W and 700W for 15 minutes respectively. In addition, the curve was best fit with first order kinetics using the least-square method. The ranges of a first order rate constant k and r-square were $0.0298{\sim}0.0375min^{-1}$ and $0.9373{\sim}0.9541$ respectively.