• 제목/요약/키워드: Heating and load test machine

검색결과 6건 처리시간 0.025초

고온가열을 받은 고강도 콘크리트의 역학적 특성에 관한 실험적 연구 (An Experimental Study on the Mechanical Properties of High Strength of High Strength Concrete Subject to High Temperature Heating)

  • 이태규;신승봉;김영선;이승훈;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.9-12
    • /
    • 2007
  • Recently, research and development related to high strength concrete for the high rise and large scale reinforced concrete building has been actively promoted in worldwide by national and private research project. But, it is reported that violent explosive explosion would be happened when it was exposed in fire. In the existed study, a explosion in a reinforced concrete structure looses the organism by the different contraction and expansion of hardened cement paste and aggregate, and causes crack by thermal stress. In case of the Europe, Japan and America, they have studied the explosion for a long time. However it would hardly study the explosion in domestic, So it is needed base on mechanical properties of fire deterioration in high strength concrete. Therefore, this study is intend as an mechanical properties of specimen to high heating by heating and load test machine and $700^{\circ}C$. As a result, it is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design high strength concrete.

  • PDF

Multi-Channel Mechanical Test Machine for HANARO (I)

  • Song, M.S.;Choi, Y.;Cho, M.S.;Kim, B.G.;Kang, Y.H.
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2004년도 추계학술발표회 발표논문집
    • /
    • pp.979-980
    • /
    • 2004
  • A multi-channel mechanical test machine for HANARO was designed and fabricated based on the design criteria of the multi-channel mechanical test machine sustained at the working conditions of $<400{\square}$, 3 W/g of gamma heating rate, $5{\times}10^{20}\;n/cm^2$, neutron flux and maximum load of 200 MPa. The multi-channel mechanical test machine made of 304 stainless steel consisted of four modules. Two of them locate upper part of the machine and the others locate lower part with 90 degree rotation. Each module was evaluated by determine load-displacement curve of zirconium specimen. Thermal insulators were also made by electron spark-machining of pure aluminum which was prepared in a domestic company.

  • PDF

비재하 가열시험 및 Stub 시험체를 활용한 CFT기둥의 역학적 특성평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Mechanical Properties of CFT Column by Unstressed Test and Stub Specimen)

  • 이대희;이태규;이의배;김영선;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.209-213
    • /
    • 2008
  • Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) because material and method are required to be diversification and High-Performance according to increase the super-high structure. But, CFT column lose bearing capacity under fire because steel tube is exposed to outside. As a result, structure is collapsed and then it cause much damage. In case of the Europe, Japan and America, they have studied the fire-resistance performance of CFT under fire for a long time. However, it would have hardly studied it in domestic because it is much difficulty about experiment machine and cost. So it is needed base on fire-resist performance of CFT under fire. Therefore, this study dynamic specificity of stub column which made tester of stub column based on facts of strength and mixing fiber evaluated used heating and load testing machine. As a result, it is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design high strength concrete.

  • PDF

Reduced LS-SVM을 이용한 지역난방 동절기 공동주택 난방부하의 모델링 (Modeling of Winter Time Apartment Heating Load in District Heating System Using Reduced LS-SVM)

  • 박영칠
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.283-292
    • /
    • 2015
  • A model of apartment heating load in a district heating system could be useful in the management and utilization of energy resources, since it could predict energy usage and so could assist in the efficient use of energy resources. The heating load in a district heating system varies in a highly nonlinear manner and is subject to many different factors, such as heating area, number of people living in that complex, and ambient temperature. Thus there are few published papers with accurate models of heating load, especially in domestic literature. This work is concerned with the modeling of apartment heating load in a district heating system in winter, using the reduced least square support vector machine (LS-SVM), and with the purpose of using the model to predict heating energy usage in domestic city area. We collected 23,856 pieces of data on heating energy usage over a 12-week period in winter, from 12 heat exchangers in five apartments. Half of the collected data were used to construct the heating load model, and the other half were used to test the model's accuracy. The model was able to predict the heating energy usage pattern rather accurately. It could also estimate the usage of heating energy within of mean absolute percentage error. This implies that the model prediction accuracy needs to be improved further, but it still could be considered as an acceptable model if we consider the nonlinearity and uncertainty of apartment heating energy usage in a district heating system.

지역난방 동절기 공동주택 온수급탕부하의 LS-SVM 기반 모델링 (LS-SVM Based Modeling of Winter Time Apartment Hot Water Supply Load in District Heating System)

  • 박영칠
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.355-360
    • /
    • 2016
  • Continuing to the modeling of heating load, this paper, as the second part of consecutive works, presents LS-SVM (least square support vector machine) based model of winter time apartment hot water supply load in a district heating system, so as to be used in prediction of heating energy usage. Similar, but more severely, to heating load, hot water supply load varies in highly nonlinear manner. Such nonlinearity makes analytical model of it hardly exist in the literatures. LS-SVM is known as a good modeling tool for the system, especially for the nonlinear system depended by many independent factors. We collect 26,208 data of hot water supply load over a 13-week period in winter time, from 12 heat exchangers in seven different apartments. Then part of the collected data were used to construct LS-SVM based model and the rest of those were used to test the formed model accuracy. In modeling, we first constructed the model of district heating system's hot water supply load, using the unit heating area's hot water supply load of seven apartments. Such model will be used to estimate the total hot water supply load of which the district heating system needs to provide. Then the individual apartment hot water supply load model is also formed, which can be used to predict and to control the energy consumption of the individual apartment. The results obtained show that the total hot water supply load, which will be provided by the district heating system in winter time, can be predicted within 10% in MAPE (mean absolute percentage error). Also the individual apartment models can predict the individual apartment energy consumption for hot water supply load within 10% ~ 20% in MAPE.

열분해 온도와 성형압력의 영향에 따른 비정질 탄화규소 블록의 치밀화 (Effect of pyrolysis temperature and pressing load on the densification of amorphous silicon carbide block)

  • 주영준;주상현;조광연
    • 한국결정성장학회지
    • /
    • 제30권6호
    • /
    • pp.271-276
    • /
    • 2020
  • 본 연구에서는 유기 규소 폴리머(organosilicon polymer)인 폴리카보실란(polycarbosilane, PCS)을 사용하여 비정질 탄화규소 블록을 제조를 진행하였다. 다양한 형상의 치밀한 탄화규소 블록은 큐어링된 PCS 미세분말을 일축가압성형기를 통해 2~8 ton 하중을 가한 후 1100℃, 1200℃, 1300℃, 1400℃의 열처리 과정을 거쳐 제조되었으며, 물리적 화학적 특성 분석을 위해 열중량분석기(TGA), 주사전자현미경(SEM), 에너지분광분석법(EDS), 만능시험기(UTM)을 이용하였다, 제조된 탄화규소 성형체는 열분해 온도가 증가함에 따라 SiO와 CO 가스로의 분해가 발생하였고, 비정질의 구조에서 β-SiC 결정입자가 성장함을 보였다. 또한, 밀도와 굴곡강도는 1100℃의 열분해 온도에서 제조된 탄화규소 성형체가 1.9038 g/㎤과 6.189 MPa으로 가장 높았다. 제조된 비정질 탄화규소 블록은 이전에 보고된 마이크로파 도움 발열체와 같이 다른 분야에 적용 가능할 것으로 기대된다.