• 제목/요약/키워드: Heating Pressure

검색결과 917건 처리시간 0.031초

배압터빈을 사용하는 열병합발전소의 열 회수 온도에 따른 성능특성 분석 (Performance Analysis on CHP Plant using Back Pressure Turbine according to Return Temperature Variation)

  • 임신영;이종준;전영신;김형택
    • 한국유체기계학회 논문집
    • /
    • 제19권6호
    • /
    • pp.26-33
    • /
    • 2016
  • Combined heat and power (CHP) system is one of the power generation system which can generate both electricity and heat. Generally, mid-size and big-size CHP plant in Korea generate electricity from gas turbine and steam turbine, then supply heat from exhaust gas. Actually, CHP can supply heat using district heater which is located at low pressure turbine exit or inlet. When the district heater locates after low pressure turbine, which called back pressure type turbine, there need neither condenser nor mode change operating control logic. When the district heater locates in front of low pressure turbine or uses low pressure turbine extraction steam flow, which calls condensing type turbine, which kind of turbine requires condenser. In this case, mode change operation methods are used for generating maximum electricity or maximum heat according to demanding the seasonal electricity and heat.

피복된 전열면에서의 비등특성(대기압 이하의 압력에서) (Behavior of boiling heat transfer at coated heating surface(In the range of subatmosptheric pressure))

  • 문대영;오수철;임장순
    • 대한설비공학회지:설비저널
    • /
    • 제6권1호
    • /
    • pp.1-8
    • /
    • 1977
  • This paper describes an experimental investigation which has been carried out with distilled water with the range of heat flux and pressure covering 7,400-28,000kcal/$m^2/h$ and 0.42-1.0332kg/$cm^{2}abs$, respectively. In this experiment, Nickel coated mirror surface heater of 5 cm O.D. was used as a heating source. The conclusions summerized as follows;1. The useful correlation of the test data for the heat transfer coefficient is presented as a function of the pressure. $$a/a_{s}=c{\times}p\;0.18$$ where a is the heat transfer coefficient and $a_s$ is the heat transfer coefficient at atmospheric pressure and p is the pressure, C is constant. 2. The bubble diameter near the heating surface and rising velocity increased with the heat flux. 3. A decrease in pressure results in the decrease of the number of nucleation sites and the increase of the bubble volume. 4. Bubble rising velocity differences are incrased maximumly up to $200\%$ of that at atmopheric pressure.

  • PDF

가열 속도에 따른 콘크리트의 폭렬 특성 및 내부 수증기압력 평가 (Evaluation of Spalling Property and Water Vapor Pressure of Concrete with Heating Rate)

  • 최경철;이태규;남정수;박병근;김규용
    • 콘크리트학회논문집
    • /
    • 제24권5호
    • /
    • pp.605-612
    • /
    • 2012
  • 콘크리트의 폭렬 발생 메커니즘에 대해서는 수증기압력에 의한 파괴, 내 외부의 온도 차이에 의해 발생하는 표면 압축력에 의한 파괴, 앞선 두 가지 요인의 복합작용에 의한 파괴가 있다. 이러한 폭렬에 영향을 주는 요인은 콘크리트 자체의 재료적 특성과 관계된 내부 요인과 환경에 의한 외부 요인으로 나눌 수 있으며 폭렬 현상을 이해하기 위해서는 두 가지 요인에 대한 충분한 고려가 필요하다. 외부 환경의 요소로써 가열 속도가 다른 경우 콘크리트 내부의 수분응집 및 수증기압력의 거동이 달라질 것으로 판단된다. 따라서 이 연구에서는 30, 50, 70, 90, 110 MPa의 다양한 강도 영역의 콘크리트를 대상으로 ISO-834 표준가열곡선과 $1^{\circ}C/min$의 가열 속도를 적용하여 가열 속도에 따른 콘크리트의 폭렬 성상 및 수증기압력, 열팽창 변형을 평가하였다. 실험 결과 콘크리트의 폭렬은 급속 가열조건에서 발생하며, 콘크리트가 고강도화될수록 폭렬에 의한 단면손실량이 증가하였다. 또한, 가열 초기에 콘크리트 표면부의 수증기압력 상승 속도 및 가열 속도에 따른 열팽창에 의한 초기압력 상쇄효과가 콘크리트의 폭렬 발생에 중요한 영향을 미치는 것으로 나타났다.

멜라민시트 적층 MDF 마루판재의 가열에 의한 치수변화 (Dimensional Change of Melamine Sheet Laminated MDF Flooring by Heating)

  • 민일홍;김의식;한규성
    • Journal of the Korean Wood Science and Technology
    • /
    • 제24권4호
    • /
    • pp.32-39
    • /
    • 1996
  • The overall purpose of this study was to investigate the dimensional changes of melamine sheet laminated medium density fiberboard(MDF) floorings by sub-heating system(Ondol). This study was also conducted to improve the properties of melamine sheet laminated MDF floorings. The effects of density, resin content, manufacturing speed of MDF and types of melamine sheet on dimensional and weight changes of floorings were investigated. The results were as followings. 1. Dimensional and weight change of melamine sheet laminated MDF flooring by heating decreased with decreasing the density of MDF. 2. Dimensional and weight change of melamine sheet laminated MDF flooring by heating decreased with increasing the resin content of MDF. 3. Dimensional and weight change of melamine sheet laminated MDF flooring by heating decreased with decreasing the manufacturing speed of MDF. 4. Dimensional change of melamine sheet laminated MDF flooring in width direction by heating was doubled than that in machine direction. 5. Dimensional change and curling of high pressure melamine laminate(HPM) laminated MDF flooring by heating was less than those of low pressure melamine laminate(LPL) flooring. 6. Weight loss of melamine sheet laminated MDF flooring by heating has linear relationship with shrinkage.

  • PDF

Thermal-Hydraulic Test Facilities and Some Test Results of Integrated Heating Reactors

  • Jia, Haijun;Wu, Shaorong;Jiang, Shengyao
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.211-216
    • /
    • 1996
  • Since the middle of the eighties of this century a research program both for heating reactor and investigation of heating reactor thermal-hydraulics has been carried out in Institute of Nuclear Energy Technology(INET) of Tsinghua university in China. This kind of heating reactor is a light water cooled and integrated natural circulation reactor with low system pressure and low quality at the exit of core. Because of relatively long riser and low system pressure. a little change of the quality at the exit of the core will result in a relatively large variation of void fraction in the riser. Two full scale test loops. HRTL-5 and HRTL-200 simulating the HR-5 and HR-200 heating reactors in geometry and operation parameters respectively, and some test results from the HRTL-200 test facility are shown in this paper. The range of studied system pressure is from 1.0MPa to 4.0MPa, the largest heat flux is about 50 W/cm2, and the quality at the exit of test section is less than 5%.

  • PDF

P/M법과 유도가열법을 이용한 A1 Foam 재료의 기공제어 (Control of Cell Morphology of Al Foams fabricated by P/M Method and Induction Heating)

  • 윤성원;이승후;강충길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2001년도 추계학술대회 논문집
    • /
    • pp.289-292
    • /
    • 2001
  • Aluminium foams, having a closed cell structure, fabricated by applying the powder compact method and an induction heating were studied. The powdered A6061 mixed with the powdered titanium hydride as a foaming agent was hot pressed into a foamable precursor. The resulting precursor was foamed by induction heating up to desired temperature. The effects of the titanium hydride content ($0.3{\~}1.5 wt.\%$), pressing pressure of the foamable precursor material (50-150kN), the forming temperature ($610{\~}690^{\circ}C$) and heating rate during foaming on the expansion behavior of the foam were investigated.

  • PDF

Experimental study of bubble flow behavior during flow instability under uniform and non-uniform transverse heat distribution

  • Al-Yahia, Omar S.;Yoon, Ho Joon;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • 제52권12호
    • /
    • pp.2771-2788
    • /
    • 2020
  • Experiments are conducted to study bubble flow behavior during the instability of subcooled boiling under uniform and non-uniform transverse heating. The non-uniform heat distribution introduces nonuniform bubble generation and condensation rates on the heated surface, which is different from the uniform heating. These bubble generation and condensation characteristics introduce a non-uniform local pressure distribution in the transverse direction, which creates an extra non-uniform pressure on the flowing bubbles. Therefore, different bubble flow behavior can be observed between uniform and non-uniform heating conditions. In the uniform heating, bubble velocity fluctuations are low, and the bubbles travel straight along the axial direction. In the non-uniform heating, more fluctuation in the bubble velocity occurs at low mass flow rate and high subcooled inlet temperatures, and reverse flow is observed. Additionally, the bubbles show a zigzag trajectory when they pass through the channel, which indicates the existence of cross flow in the transverse direction.

바이패스용 3-Way 밸브를 장착한 온수 난방시스템의 압력 및 유량 특성 평가 (Performance Test of Pressure and Flow Rate in a Hot-Water Heating System with 3-Way Valves for Flow Bypass)

  • 허전;이석종;성재용;이명호;윤재동
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.269-274
    • /
    • 2007
  • A 3-way valve has been applied to a distributor in a hot-water heating system and the performance of the system was evaluated in view of the variations of pressure drop and flow rate. The 3-way valve has been designed to bypass overplus hot-water when a control valve is closed. Note that the flow goes through heating pipeline in normal operation. In the present study, the measured pressure drops in each part of the flow paths show that the contribution to the total pressure drop is in the order of the supply header with control valves, piping system of each room and return header of the distributor, even though the amount of it is different according to the flow paths. As a result of performance test by sequential closing of the control valves, the variations of pressure drop and flow rate in the distributor with 3-way valves is much lower than those with previous 2-way valves, which prevent noises induced by pressure fluctuations.

온간 하이드로포밍 공정을 위한 시스템 설계 (Process Design for the Tubular Hydroforming at Elevated Temperatures)

  • 김봉준;박광수;손성만;이문용;문영훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.226-229
    • /
    • 2006
  • Process design has been performed for the warm hydroforming of light weight alloy tubes. For the heating of tubes, specially designed induction heating system has been adopted to ensure rapid heating of tubes. The induction heating system uses 30kHz frequency induction coil in order to concentrate the energy in the tube and prevent the energy loss. But the induced heat by the integrated heating system, consisting of induction coil, tube, pressure oil and dies, was normally not equally distributed over the length and circumference of the tube specimen, and consequent temperature distribution was non-uniform. So additional heating element has been inserted into the inside of the tube to maintain the forming temperature and reduce temperature drop due to heat loss to the molds. And for that heat loss, a heat insulation system has also been installed. The drop in flow stress at elevated temperatures results in lower internal pressure for hydroforming and lower clamping forces. The proposed warm hydroforming process has been successfully implemented when applying 6061 aluminum extruded tubes.

  • PDF

탁상용 소형 사출 성형기 개발 (Developed Compact Injection Molding Machine for Desktop)

  • 이병호;신동화
    • 한국산업융합학회 논문집
    • /
    • 제21권5호
    • /
    • pp.257-263
    • /
    • 2018
  • It is a small injection molding machine for table top considering the material heating mechanism and the design and structure stability by securing the mechanism that compresses the inside of the material heating tube by using the electric actuator and by providing space between the body and the material heating tube to reduce heat loss Develop body. An electric actuator suitable for applying pressure to the inside of a material heating tube is a mechanical system composed of a rigid structure. Since a large force is repeatedly applied to the electric actuator and the push rod, the interaction between the moving parts and the dynamic Maximum stress through analysis and prediction of fatigue life of critical parts The pushrod reflects the structural analysis results of the electric actuator and the push rod, and pushes the inside of the material heating tube by the push rod to inject the molten material from the nozzle into the mold. The pushrod operates by the operation of the electric actuator. The material heated by the coil heater is ejected through the nozzle by the pressure of the material heating tube, and the material heating tube and the nozzle are also lowered at the same time as the push rod is lowered, so that the material is closely adhered to the mold. We want to study the completion of the injection.