• Title/Summary/Keyword: Heating Period

Search Result 540, Processing Time 0.199 seconds

A Study on the Proper Quantity of Ventilation through Changing Floor Temperature in Sleeping (수면시 바닥표면온도에 따른 적정 환기량에 관한 연구)

  • Kim, Dong-Gyu;Lee, Sung;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Modern people are spending most of time in interior area. Indoor air environmental problem is one of the most effective factors influenceable to human health. Furthermore, saving energy and making ventilation system for pleasant indoor environment are necessary when it is faced shortage of energy over the world. In our country's case, it is already imposed that required quantity of air ventilation in buildings is 0.7 times per hour on "The regulation on building engineering system". As on the rise of the interests about Indoor air environment, Heat and Carbon dioxide emissions from User's metabolism, activity, furniture, and construction materials etc. could be the causes of Indoor air pollution. If these materials stays in Indoor air for so long, it could directly influence the user's health condition with a disease. As of building's sterilization improved that raised more mechanical ventilation. It also leads much energy waste in a period of high price of fossil fuel. Therefore, the way that saves energy and effective control of indoor ventilation is urgently needed. So, this study places the purpose on validating volume of indoor ventilation and user's comfortable degree by comparison CO2 emission rate through changing floor temperature.

Relation between the Building Exterior Conditions and Energy Costs in the Running period of the Apartment Housing (공동주택의 건물외부조건과 에너지비용과의 관계분석)

  • Lee, Kang-Hee;Ryu, Seung-Hoon;Lee, Yeun-Taek
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.107-113
    • /
    • 2009
  • The energy cost is resulted from the energy use. Its sources are divided into some types and depended on the building use or energy-use type. The energy cost should be affected by the amount of the energy use. The cost could be calculated to consider various factors such as the insulation, heating type, building shape and others. But it can not consider all of the affect factors to the energy cost and need to categorize the factors to the condition for estimating the cost. In this paper, it aimed at providing the estimation model in linear equation and multiple linear regression, utilizing the building exterior condition and management characteristics in apartment housing. Its survey are conducted in two parts of management characteristics and building exterior condition. The correlation analysis is conducted to get rid of the multicolinearity among the inputted factors. The number of linear equation model is 11 and includes the 1st, 2nd and 3rd equation function, power function and others. Among these, it suggested the 2nd and 3rd function and power function in terms of the statistics. In multiple linear regression model, the building volume and management area are inputted to the estimation.

Effects of Surface Radiation on the Unsteady Natural Convection in a Rectangular Enclosure

  • Baek, Seung-Wook;Kim, Taig-Young
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.1
    • /
    • pp.95-104
    • /
    • 2002
  • Numerical solution of the full Navier-Stokes equation as well as the energy equation has been obtained for the unsteady natural convection in a rectangular enclosure. One side wall was maintained at very high temperature simulating fires. Especially the effect of surface radiation was taken into account. While the enclosed air was assumed to be transparent, the internal walls directly interacted one another through the surface radiation. Due to a significant temperature difference in the flow field, the equation of state was used instead of the Boussinesq approximation. It was found that the rapid heating of the adiabatic ceiling and floor by the incoming radiation from the hot wall made the evolution at thermo-fluid field highly unstable in the initial period. Therefore, the secondary cells brought about at the floor region greatly affected the heat transfer mechanism inside the enclosure. The heat transfer rate was augmented by the radiation, resulting in requiring less time for the flow to reach the steady state. At the steady state neglecting radiation two internal hydraulic jumps were clearly observed in upper/left as well as in lower/right comer. However, the hydraulic jump in the lower/right comer could not be observed for the case including radiation due to its high momentum flow over the bottom wall. Radiation resulted in a faster establishment of the steady state phenomena.

Modeling Techniques using Virtual Fixture for Analysing the Shrinkage of Axi-symmetric Welded Structures (가상 고정물을 이용한 축 대칭 용접물의 용접 변형 해석 모델링 기법)

  • Lee, Ho-Jin;Lee, Bong-Sang;Jung, In-Chul;Shim, Deog-Nam
    • Journal of Welding and Joining
    • /
    • v.28 no.2
    • /
    • pp.60-65
    • /
    • 2010
  • Although two dimensional axi-symmetric modeling is useful for calculating the residual stresses of a cylindrical weldment such as a core barrel, this conventional axi-symmetric modeling can not express the behavior of shrinkage well in the locally heated weld zone. New technique of two dimensional axi-symmetric modeling using a virtual fixture is suggested to simulate the behavior of dimensional changes in the weld zone during the heating period of the welding. The virtual fixture in the model has a role to restrain the expansion of the high temperature heated region, which simulates equivalent intrinsic restraint effect of the weldment. In the restraint condition of the virtual fixture above the critical yield strength, the calculated shrinkages by using the suggested axi-symmetric model agreed well with those measured in a welded mock-up. The calculated residual stresses by using the suggested axi-symmetric model also agreed well with those calculated by using conventional axi-symmetric model which has beenused for calculating residual stresses in the weldment.

Reducing Veterinary Drug Residues in Animal Products: A Review

  • Rana, Md Shohel;Lee, Seung Yun;Kang, Hae Jin;Hur, Sun Jin
    • Food Science of Animal Resources
    • /
    • v.39 no.5
    • /
    • pp.687-703
    • /
    • 2019
  • A survey we conducted suggests that the ingestion of veterinary drug residues in edible animal parts constitutes a potential health hazard for its consumers, including, specifically, the possibility of developing multidrug resistance, carcinogenicity, and disruption of intestinal normal microflora. The survey results indicated that antibiotics, parasitic drugs, anticoccidial, or nonsteroidal anti-inflammatory drugs (NSAIDs) are broadly used, and this use in livestock is associated with the appearance of residues in various animal products such as milk, meat, and eggs. We observed that different cooking procedures, heating temperatures, storage times, fermentation, and pH have the potential to decrease drug residues in animal products. Several studies have reported the use of thermal treatments and sterilization to decrease the quantity of antibiotics such as tetracycline, oxytetracycline, macrolides, and sulfonamides, in animal products. Fermentation treatments also decreased levels of penicillin and pesticides such as dimethoate, malathion, Dichlorodiphenyldichloroethylene, and lindane. pH, known to influence decreases in cloxacillin and oxacillin levels, reportedly enhanced the dissolution of antimicrobial drug residues. Pressure cooking also reduced aldrin, dieldrin, and endosulfan in animal products. Therefore, this review provides updated information on the control of drug residues in animal products, which is of significance to veterinarians, livestock producers, and consumer health.

Higher Production of Biolipids from Botryococcus braunii using Pre-treated Solvent Extraction Methods (해양생물 Botryococcus braunii에서 유래한 바이오연료의 고급생산기술: 전처리 용매추출법)

  • Kwon, Sung-Hyun;Cho, Daechul
    • Journal of Environmental Science International
    • /
    • v.28 no.11
    • /
    • pp.927-933
    • /
    • 2019
  • A lipid-enriched strain of Botryococcus braunii (UTEX 572) was cultivated in a semi-batch aeration tank to enhance biomass as well as to develop intracellular lipids and fatty acids. A 30 day period of incubation produced 1.39 g/L of biomass and 0.31 g/L of total lipids in the biomass. The grown biomass was pre-treated using several methods to extract the total lipid content efficiently: ultrasonication was found to yield the highest percentage of lipids-namely 19.8% per biomass. Direct heating of biomass in an autoclave also showed better performance than when using only conventional solvent extraction. To enhance the biomass harvest and lipid extraction efficiency, coagulation and flocculation steps were added to the extraction process. It is noteworthy that not only the solvent type but also the solvent/biomass ratio greatly affected efficiency. In addition, the moisture content of the harvested(wet) biomass affected the efficiency significantly. This study elucidated the need for future research on optimizing this extraction process.

Determination of reaction kinetics during vitrification of radioactive liquid waste for different types of base glass

  • Suneel, G.;Rajasekaran, S.;Selvakumar, J.;Kaushik, Chetan P.;Gayen, J.K.;Ravi, K.V.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.746-754
    • /
    • 2019
  • Vitrification of radioactive liquid waste (RLW) provides a feasible solution for isolating radionuclides from the biosphere for an extended period. In vitrification, base glass and radioactive waste are added simultaneously into the melter. Determination of heat and mass transfer rates is necessary for rational design and sizing of melter. For obtaining an assured product quality, knowledge of reaction kinetics associated with the thermal decomposition of waste constituents is essential. In this study Thermogravimetry (TG) - Differential Thermogravimetry (DTG) of eight kinds of nitrates and two oxides, which are major components of RLW, is investigated in the temperature range of 298-1273 K in the presence of base glasses of five component (5C) and seven component (7C). Studies on thermal behavior of constituents in RLW were carried out at heating rates ranging from 10 to $40\;K\;min^{-1}$ using TG - DTG. Thermal behavior and related kinetic parameters of waste constituents, in the presence of 5C and 7C base glass compositions were also investigated. The activation energy, pre-exponential factor and order of the reaction for the thermal decomposition of 24% waste oxide loaded glasses were estimated using Kissinger method.

Investigation of surface homogeneity of (3200) Phaethon

  • Lee, Hee-Jae;Kim, Myung-Jin;Kim, Dong-Heun;Moon, Hong-Kyu;Choi, Young-Jun;Kim, Chun-Hwey;Lee, Byeong-Cheol;Yoshida, Fumi;Roh, Dong-Goo;Seo, Haingja
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.45.1-45.1
    • /
    • 2018
  • We present observational evidence of the surface homogeneity on Phaethon based on the time-series multi-band photometry and spectrometry. The observations of Phaethon were conducted in Nov.-Dec. 2017. We confirmed that Phaethon is a B-type asteroid, as was previously known, and its rotational color variation was not detected. During our observation period, the sub-solar latitude of this asteroid was approximately $55^{\circ}S$, corresponding to the southern hemisphere of the body. Thus, we found that the southern hemisphere of Phaethon has a homogeneous surface from our observation results. In addition, we compared our spectra with archival data to investigate the latitudinal surface properties of the asteroid. The result showed that it doesn't have a latitudinal color variation. To verify this assumption, we investigated its solar-radiation heating effect, and the result suggested that this asteroid underwent a uniform thermal metamorphism regardless of latitude, which is consistent with our observations. Based on this result, we discuss the homogeneity of the surface of the body.

  • PDF

An experimental and numerical analysis of concrete walls exposed to fire

  • Baghdadi, Mohamed;Dimia, Mohamed S.;Guenfoud, Mohamed;Bouchair, Abdelhamid
    • Structural Engineering and Mechanics
    • /
    • v.77 no.6
    • /
    • pp.819-830
    • /
    • 2021
  • To evaluate the performance of concrete load bearing walls in a structure under horizontal loads after being exposed to real fire, two steps were followed. In the first step, an experimental study was performed on the thermo-mechanical properties of concrete after heating to temperatures of 200-1000℃ with the purpose of determining the residual mechanical properties after cooling. The temperature was increased in line with natural fire curve in an electric furnace. The peak temperature was maintained for a period of 1.5 hour and then allowed to cool gradually in air at room temperature. All specimens were made from calcareous aggregate to be used for determining the residual properties: compressive strength, static and dynamic elasticity modulus by means of UPV test, including the mass loss. The concrete residual compressive strength and elastic modulus values were compared with those calculated from Eurocode and other analytical models from other studies, and were found to be satisfactory. In the second step, experimental analysis results were then implemented into structural numerical analysis to predict the post-fire load-bearing capacity response of the walls under vertical and horizontal loads. The parameters considered in this analysis were the effective height, the thickness of the wall, various support conditions and the residual strength of concrete. The results indicate that fire damage does not significantly affect the lateral capacity and stiffness of reinforced walls for temperature fires up to 400℃.

Hygroscopicity of 1:2 Choline Chloride:Ethylene Glycol Deep Eutectic Solvent: A Hindrance to its Electroplating Industry Adoption

  • Brusas, John Raymund;Dela Pena, Eden May B.
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.387-397
    • /
    • 2021
  • Deep eutectic solvents have been established as feasible metal electroplating solvent alternatives over traditional toxic aqueous plating baths. However, water, either added intentionally or unintentionally, can significantly influence the solvent's physical properties and performance, thereby hindering its industry application. In this study, the hygroscopicity, or the ability to absorb moisture from the environment, of synthesized ethaline (1:2 choline chloride:ethylene glycol) was investigated. The kinematic viscosity, electrical conductivity, electrochemical window, and water content of ethaline were monitored over a 2-week period. Karl Fischer titration tests showed that ethaline exposed to the atmosphere displayed significant hygroscopicity compared to its unexposed counterpart. 1H NMR spectroscopy revealed that water vapor was readily absorbed at the surface due to the hydrophilic groups present in the ethaline molecule. Water uptake resulted in the decrease in viscosity, increase in electrical conductivity and narrowing of the electrochemical window of ethaline. Solution heating at 100℃ removed the absorbed moisture and allowed the recovery of the solvent's initial properties.