• Title/Summary/Keyword: Heating Period

Search Result 543, Processing Time 0.024 seconds

Heating Performance Prediction of Low-depth Modular Ground Heat Exchanger based on Artificial Neural Network Model (인공신경망 모델을 활용한 저심도 모듈러 지중열교환기의 난방성능 예측에 관한 연구)

  • Oh, Jinhwan;Cho, Jeong-Heum;Bae, Sangmu;Chae, Hobyung;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.3
    • /
    • pp.1-6
    • /
    • 2022
  • Ground source heat pump (GSHP) system is highly efficient and environment-friendly and supplies heating, cooling and hot water to buildings. For an optimal design of the GSHP system, the ground thermal properties should be determined to estimate the heat exchange rate between ground and borehole heat exchangers (BHE) and the system performance during long-term operating periods. However, the process increases the initial cost and construction period, which causes the system to be hindered in distribution. On the other hand, much research has been applied to the artificial neural network (ANN) to solve problems based on data efficiently and stably. This research proposes the predictive performance model utilizing ANN considering local characteristics and weather data for the predictive performance model. The ANN model predicts the entering water temperature (EWT) from the GHEs to the heat pump for the modular GHEs, which were developed to reduce the cost and spatial disadvantages of the vertical-type GHEs. As a result, the temperature error between the data and predicted results was 3.52%. The proposed approach was validated to predict the system performance and EWT of the GSHP system.

A Study on the Dwellings of Korean Diaspora in Russia and Central Asia (옛 소련 지역 한국인 동포의 주거건축에 관한 연구 - 단독주택 평면을 중심으로 -)

  • Lee, Sang-Hae
    • Journal of architectural history
    • /
    • v.13 no.4 s.40
    • /
    • pp.19-34
    • /
    • 2004
  • This study examines the dwellings of the Korean diaspora in Maritime Provinces of Russia, and Kazakhstan and Uzbekistan of Central Asia to find the gist of the residence transformed as Korean traditional residence culture to accept Russian foreign culture. Through the examination, transformation process of the dwellings of the Korean diaspora was found as follows: - 1st Period(1864-1937): The Korean diaspora who Immigrated to Maritime Provinces of Russia built traditional houses of Korean style and few of them lived in Russian style houses. - 2nd Period(1937-1955): The Koreans who immigrated to Central Asia from Maritime Provinces under compulsion built 'ground house' by digging the earth and installed gudeul which is a traditional Korean heating system and roofed with reed. - 3rd period(1955-1991): The Koreans built straight lined '-' shape houses with two or three rooms wherein most of them were installed with gudeul to heat the room. Around the 1940s as they economically got well, the Koreans started to build houses with Russian style with one or two rooms with gudeul or a separate building with gudeul. - 4th period(1991-present): Houses of the 3rd period are still used by being enlarged or remodeled with less use of gudeul which is well reflected on Ujeong-maul village in Russia Maritime Provinces. As can be found above, the dwellings of the Korean diaspora in Russia Maritime Provinces and Central Asia are on the process of being transformed into Russian style to adapt to Russian culture.

  • PDF

Investigation of Growth Characteristics of Commercial Cultivars and Classification into cropping System Based on Degree and Duration of Dormancy in Strawberry (딸기 주요품종의 생육특성 및 휴면정도에 따른 작형분화 연구)

  • Ra, Sang-Wook;Yoon, Wha-Mo;Woo, In-Sik;Roh, Tae-Hong
    • The Journal of Natural Sciences
    • /
    • v.11 no.1
    • /
    • pp.105-111
    • /
    • 1999
  • The objectives of this research were to determine growth characteristics of commercial cultivars of strawberry grown in Korea, then to differentiate each cuitivar into cropping system based on degree and duration of domancy and to determine starting date of greenhouse heating as forced culture. The date of floral differentiation on cuitivars such as 'Chodong' 'Shuko' 'Nyoho' was from Sep. 20 to 22. However those of 'Toyonoka', 'Reiko', 'Hokowase' etc. were Sep. 26 to 30 and that of 'Morioka(No. 16)' was Oct. 19. It indicated that the cultivars with short dormancy period 'Nyoho', 'Reiko', 'Toyonoka' etc. were suitable for forcing culture, cultivar with ordinary dormancy period such as 'Suhong' was for nearly forcing culture, cultivar with long dormancy period such as 'Hokowase' was for semi-forcing culture, and cultivar with extreamly long dormancy period such as 'Morioka (No. 16)' was for retarding culture.

  • PDF

Heating Performance of Hot Water Supplying System in Greenhouse (온수배관을 이용한 온실의 난방성능)

  • Yoon, Yong-Cheol;Shin, Yik-Soo;Kim, Hyeon-Tae;Bae, Seoung-Beom;Choi, Jin-Sik;Suh, Won-Myung
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.79-87
    • /
    • 2012
  • This research was conducted to obtain basic data with regard to the heating performance that would be produced by installing an aluminum hot water pipe inside the greenhouse with the goal of reducing the heating energy in greenhouse. The research results are summarized as follows. The degree of difference in relation to the temperature by height within the greenhouse during the entire experiment was significant - within the range of 4.0~$7.0^{\circ}C$. The temperature difference between incoming and outgoing water was about $3.3^{\circ}C$ greater when FCU was activated compared to when it was not activated. Meanwhile, the amount of energy consumed increased about 36.2~40.1%. The amount of pyrexia per hour also increased by 44.6~52.0%. During the experiment period, circulated flux was within the range of 0.48~$0.49L{\cdot}s^{-1}$ while average fluid speed was 1.53~$1.56m{\cdot}s^{-1}$. The average temperature difference between incoming and outgoing water was 6.24~$11.50^{\circ}C$. The amount of heating value by each set temperature within the minimum outdoor temperature range of -14.0~$-0.6^{\circ}C$ was 135,930~307,150 kcal, and the range was within the 9,610~$19,630kcal{\cdot}h^{-1}$ per hour. This demonstrated that about 23~53% heating energy of the maximum heating load could be supplied. Total radiating value and amount of energy consumed were 2,548,306 kcal and 3,075.7 kWh, respectively. When heating takes place using oil, which is a fossil fuel, the total amount of light oil consumed was 281.6 L while the cost was 321,000 won. When the electricity cost for farms is applied, the total cost was about 110,730 won, which is about 33.5% of the cost required compared to oil consumption. The temperature at in the experiment area was about 8.3~$14.6^{\circ}C$ higher compared to that of the control area.

Air Quality Monitoring in Daejeon City with Long-Term NO2 and SO2 Passive Diffusive Samplers (장기 NO2 및 SO2 Passive Diffusive Sampler(PDS)를 이용한 대전시 대기질 모니터링)

  • Yim, Bong-Been;Kim, Sun-Tae;Jung, Jae-Ho;Lee, Bum-Jin
    • Journal of Environmental Science International
    • /
    • v.16 no.2
    • /
    • pp.187-195
    • /
    • 2007
  • Long-term passive diffusive samplers(PDS) have been used to measure $NO_2\;and\;SO_2$ concentrations at 21 sampling sites in Daejeon, Korea during the period of January 2000 - December 2002. The spatial distributions of annual $NO_2\;and\;SO_2$ concentrations were mapped. Average annual $NO_2$ concentration over the sampling period was $28.5{\pm}12.5\;ppb$, ranging from 1.2 to 81.7 ppb. Average annual $SO_2$ concentration over the sampling period was $7.7{\pm}4.8\;ppb$, ranging from 0.6 to 26.8 ppb. On average, $NO_2$ concentration was approximately 5.8%(1.6 ppb) larger in 2002. $SO_2$ concentration was decreased by 13%(1.1 ppb) during the sampling period. The seasonal variation of $NO_2\;and\;SO_2$ concentration was observed with a tendency to be higher in fall and winter. $NO_2\;and\;SO_2$, concentrations measured at different site types(patterns of land use) show significant difference. The observed difference in concentration was associated with difference in emissions of $NO_2$ from motor vehicles and $SO_2$ by non-traffic fuel consumption for heating.

Design of Energy Model of Greenhouse Including Plant and Estimation of Heating and Cooling Loads for a Multi-Span Plastic-Film Greenhouse by Building Energy Simulation (건물에너지시뮬레이션을 활용한 연동형 온실 및 작물에너지모델 설계 및 이의 냉·난방부하 산정)

  • Lee, Seung-No;Park, Se-Jun;Lee, In-Bok;Ha, Tae-Hwan;Kwon, Kyeong-Seok;Kim, Rack-Woo;Yeo, Uk-Hyeon;Lee, Sang-Yeon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.123-132
    • /
    • 2016
  • The importance of energy saving technology for managing greenhouse was recently highlighted. For practical use of energy in greenhouse, it is necessary to simulate energy flow precisely and estimate heating/cooling loads of greenhouse. So the main purpose of this study was to develope and to validate greenhouse energy model and to estimate annual/maximum energy loads using Building Energy Simulation (BES). Field experiments were carried out in a multi-span plastic-film greenhouse in Jeju Island ($33.2^{\circ}N$, $126.3^{\circ}E$) for 2 months. To develop energy model of the greenhouse, a set of sensors was used to measure the greenhouse microclimate such as air temperature, humidity, leaf temperature, solar radiation, carbon dioxide concentration and so on. Moreover, characteristic length of plant leaf, leaf area index and diffuse non-interceptance were utilized to calculate sensible and latent heat exchange of plant. The internal temperature of greenhouse was compared to validate the greenhouse energy model. Developed model provided a good estimation for the internal temperature throughout the experiments period (coefficients of determination > 0.85, index of agreement > 0.92). After the model validation, we used last 10 years weather data to calculate energy loads of greenhouse according to growth stage of greenhouse crop. The tendency of heating/cooling loads change was depends on external weather condition and optimal temperature for growing crops at each stage. In addition, maximum heating/cooling loads of reference greenhouse were estimated to 644,014 and $756,456kJ{\cdot}hr^{-1}$, respectively.

Study on Indoor Thermal Performance Analysis upon PCM Temperature applicable to the Double Skin Facade System in the Winter (동절기 이중외피 시스템에 적용 가능한 PCM재료의 온도설정에 따른 실내 열 성능 분석에 관한 연구)

  • Ryu, Ri;Seo, Jang-hoo;Kim, Yong-seong
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.43-48
    • /
    • 2015
  • Purpose: Recently, many countries around the world are actively looking for the ways to make full use of natural energy sources and also develop and apply an environmentally friendly system designed to save building energy consumption. Under these circumstances, this study intended to determine the applicability and energy saving effect by deriving the indoor thermal performance characteristics and the PCM temperature appropriate for a double skin façade to reduce indoor energy consumption through the application of different PCM temperatures to double skin façade and perform a performance evaluation depending on the application or non-application of PCM to a double skin façade. Method: For this study, the physical variables of the double skin façade with PCM were configured through a preliminary examination based on an experimental measurement, and experimental measurements were taken with a total of 7 types of mockup cases: Type-1 (Basic), the basic double skin façade, Type-2 (PCM $18^{\circ}C$) which was applied to the inner skin of the double skin façade depending on the phase-change temperature of PCM, Type-3 (PCM $20^{\circ}C$), Type-4 (PCM $22^{\circ}C$), Type-5 (PCM $24^{\circ}C$), Type-6 (PCM $26^{\circ}C$), and Type-7 (PCM $28^{\circ}C$) with reference to the data analysis of the basic double skin façade which preceded this study, to analyze the indoor thermal performance of the double skin façade depending on PCM temperature and the installation or non-installation of a double skin façade applying PCM based on the selected unit space. Result: Indoor thermal performance was analyzed depending on the PCM temperature applicable to double skin façade, and the analysis of heating energy reduction showed that Type-2 (PCM $18^{\circ}C$) gained 15.9% more heat compared with Type-1 (Basic) and secondly, Type-3 (PCM $20^{\circ}C$) gained 11.5% more heat. Based on these findings, it is deemed possible that the use of energy for heating can be reduced when heat coming indoors increases during the heating period, and the appropriate temperature for PCM applied to the inner skin of a double skin façade to reduce heating energy in winter, Type-2 (PCM $18^{\circ}C$) showed the highest efficiency and Type-3 (PCM $20^{\circ}C$) was also deemed appropriate.

Reaction Rate Analysis of CO2 Gasification for Indonesian Coal Char at High Temperature and Elevated Pressure (고온, 고압조건에서의 인도네시아 석탄촤의 CO2 가스화 반응)

  • Lisandy, Kevin Yohanes;Kim, Ryang-Gyoon;Hwang, Chan-Won;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.781-787
    • /
    • 2014
  • A pressurized wire mesh heating reactor (PWMR) can provide high pressure and temperature experimental conditions up to 50 atm and 1750 K, respectively. This equipment was developed to evaluate the intrinsic reaction kinetics of $CO_2$ gasification. A PWMR utilizes a platinum (Pt) wire mesh resistance to generate heat with a direct current (DC) electricity supply. This DC power supply can then be controlled by computer software to reach the exact expected terminal temperature and heating period. In this study, BERAU (sub-bituminous Indonesian coal) was pulverized then converted into char with a particle size of $90-150{\mu}m$. This was used in experiments with various pressures (1-40 atm) and temperatures (1373-1673 K) under atmospheric conditions. The internal and external effectiveness factor was analyzed to determine the effects of high pressure. The intrinsic reaction kinetics of BERAU char was obtained using $n^{th}$ order reaction rate equations. The value was determined to be 203.8kJ/mol.

Effects of Oil Unsaponifiables and Plant Extracts on the Thermal Oxidation of Oils at $180^{\circ}C$ (유지 불검화물과 식물체 추출물이 식용유의 $180^{\circ}C$ 가열 산화에 미치는 효과)

  • Jung, Mun-Yhung;Yoon, Suk-Hoo;Kim, Seong-Yeol;Lee, Jee-Hyeun
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.860-868
    • /
    • 1997
  • The effects of oil unsaponifiables (8 species) and methanolic plant extracts (53 species) on the thermal oxidation of oils during 14 or 16 hour heating at $180^{\circ}C$ were studied by analyzing the fatty acid composition of soybean oil or cottonseed oil. All the unsaponifiables tested did not show any antioxidative activities on the thermal oxidation of soybean oil. However, among the 53 species of methanolic plant extracts, some species (Rheum undulatum L., Chelidonium majus L. var. asiaticum and Eugennia caryopyllata T.) showed very strong antioxidative activities on the thermal oxidation of cottonseed oil. The antioxidative activities of methanolic extracts of these 3 species on thermal oxidation of cottonseed oil during an extended heating period were also studied by heating cottonseed oils for 7 hours a day for 8 days at $180^{\circ}C$. The methanolic extracts of Chelidonium majus L. v. asiaticum and Eugennia caryopyllata T. greatly reduced both polymer formation and linoleic acid decomposition after the 8 day heating at $180^{\circ}C$. However, the methanolic extracts of Rheum undulatum L. was effective for the reduction of polymer formation, but not for the reduction of linoleic acid decomposition.

  • PDF

Changes of the phsico-Chemical Characteristics of oils treated by the ${\gamma}$-ray irradiation (I) -The Extracted soybean oil- (방사선 조사선량에 따른 유지의 이화학적 성질변화 (I))

  • 임국이
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.4
    • /
    • pp.77-88
    • /
    • 1992
  • To investigate the oxidative stabilities of the ${\gamma}$-ray irradiated soybean during storage and heating and some physico-chemical characteristics of soybean and the extracted soybean oil (SBO) with/without the ${\gamma}$-ray irradiation were determined. The ${\gamma}$-ray level use in irradiation for soybean were 2.5, 5.0 and 10.0 KGY respectively and Acid Value, Peroxide Value, Conjugated Diene Value, Composed Fatty Acids amounts, and Trans Fatty Acid occurrence were determined for all samples, which were incubated at 45$\pm$1$^{\circ}C$ for 25 days heated at 180$\pm$1$^{\circ}C$ for 30 hours. And these values of the ${\gamma}$-ray treated samples were compared to those of nontreated samples. The results were obtained as follows : 1. According to the increased level of the ${\gamma}$-ray irradiation, there was little difference in Dielectric Constant, Viscosity, and the Induction Period by Rancimat. But, in case of 5.0 KGY, oxidative stability was increased more twice than that of non-irradiation. In the quantity of fatty Acids composition of the extracted soybean oil irradiated with 10.0 KGY, palmitic, oleic and linoleic acids were less increased thanb those of non-irradiation, while stearic, linolenic acids were decreased. In the case of 2.5 KGY irradiation, stearic and oleic acids were increased. 2. The Acid Value of SBO according to the ${\gamma}$-ray irradiation level was almost not change, but was 0.1 lower than that of non-irradiation during incubation (45$\pm$1$^{\circ}C$). The Peroxide Value of SBO with the ${\gamma}$-ray irradiation, was very lower than that of non-irradiation, but its effect on oxidative stability was better of SBO treated with 5.0 KGY and 10.0 KGY. In the Fatty Acids composition of SBO, palmitic, stearic, oleic acids were increased, while linoleic, linolenic acids were decreased during incubation(45$\pm$1$^{\circ}C$). This tendency was more obvious due to the ${\gamma}$-ray level. While heating(180$\pm$1$^{\circ}C$), the Acid Value of SBO treated with the ${\gamma}$-ray irradiation was decreased, the Acid Value of SBO irradiated with 2.5 KGY was the lowest. Also the peroxide Values of SBO treated with 5.0 KGY, 10.0 KGY were very lower than that of non-irradiation. Conjugated Diene Value of SBO was almost unchanged according to the ${\gamma}$-level and heating time. 3. When the methyl linoleate was irradiated with the ${\gamma}$-ray, the Trans Fatty Acid was little produced. In case of SBO with non-irradiation, the trans C18:1 was occured about 6.5~7.9%, but trans C18:2 and C18:3 were not shown, while SBO irradiated with the ${\gamma}$-ray 2.5, 5.0, 10.0 KGY, trans C18:3 and C18:2 amount in SBO were increased according to heating time, but trans C18:3 was little occured. As these results, the effects of the ${\gamma}$-ray irradiation to oil containing food were to cut down the energy for food storage and to increase oxdative stability during storge. And also it was shown to be the best that 10.0 KGY of the ${\gamma}$-ray irradiation would be applied to soybean.

  • PDF