• Title/Summary/Keyword: Heating Period

Search Result 543, Processing Time 0.027 seconds

A Study on Pore Pressure Evaluation of Concrete Lining in Road Tunnel Fire (도로터널 라이닝 화재조건 콘크리트 라이닝 공극압력 특성에 관한 연구)

  • Park, Kyung-Hoon;Kim, Heung-Youl;Yoo, Yong-Ho;Lee, Chul-Ho;Kim, Hyung-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.484-489
    • /
    • 2008
  • We carried out a one-way heating experiment on the PC panel manufactured by changing the filling depths(20,30,40,50mm) of concrete regarding the fire strength in order to measure the inner concrete pressure which is a direct cause of concrete spalling. This fire experiment was conducted under the fire strength conditions of ISO 834 Standard, Modified Hydrocarbon and the maximum value of Pore Pressure was measured. As a result of analyzing the time it took to reach maximum pressure, it showed that the time rising to the maximum pressure of high strength concrete of 40MPa is slower than that of a 24MPa tunnel lining. In case of ISO fire conditions, spalling damage might take place in heating period of $20{\sim}40$ minutes in the range of $100{\sim}200^{\circ}C$ temperature. In case of MHC fire conditions, the area damaged by fire can appear after a lapse of $25{\sim}50$ minutes in the range of $150{\sim}250^{\circ}C$ temperature.

  • PDF

The Study on the Energy self-sufficiency and Economic Analysis of KIER Zero Energy Solar House (제로에너지 솔라하우스(KIER ZeSH)의 에너지 자립도 및 경제성 분석)

  • Jeong, Seonyeong;Baek, Namchoon;Yoo, Changkyoon;Yoon, Eungsang;Yoon, Jongho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.64.1-64.1
    • /
    • 2010
  • In this study, the energy and economic analysis of KIER Zero Energy Solar House (KIER ZeSH) was carried out. KIER ZeSH was designed and constructed in the end of 2009 for the purpose of more than 70% energy self-sufficiency in total load as well as less than 20% of additional construction cost. The several building energy conservation technologies like as super insulation, high performance window, wast heat recovery system, etc and renewable energy system. The renewable heating and cooling system is a kind of solar thermal system combined with geo-source heat pump as a back-up device. The capacity of 3.15kW solar BIPV system was also installed on the roof. The measurement by monitering system of ZeSH was conducted for one year from November 2009 to October 2010. The energy self-sufficiency and economic analysis were conducted based on the this monitering result. As a result, the energy self sufficiency is about 83% which is higher than that of the target and the payback period is 11 years.

  • PDF

An Experimental Study on the Flow Characteristics Inside an Open Two-Phase Natural Circulation Loop (개방된 2상 자연순환 회로내의 유동특성에 관한 실험적 연구)

  • 경익수;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1313-1320
    • /
    • 1993
  • Flow patterns inside the riser section and the effects of the heater inlet-and exit-restrictions, liquid charging level and the heater inlet subcooling on the flow characteristics inside an open two-phase natural circulation loop were studied experimentally. Three basic circulation modes were observed ; periodic circulation (A)(flow oscillations with incubation(no boiling) period), continuous circulations(stable operation mode with no flow oscillations), and periodic circulation (B) (flow oscillations with continuous boiling). The circulation rate increases and then decreases with the increase of the heating rate and the maximum circulation rate appears with the continuous circulation mode. The decrease of the inlet-restriction or the increase of the exitrestriction destabilizes the system. When the liquid charging level or the inlet subcooling decreases, the continuous circulation mode starts at the lower heating rate and the system is stabilized.

Analysis of a Cryogenic Nitrogen-Ambient Air Heat Exchanger Including Frost Formation (착상을 고려한 극저온 질소-대기 열교환기의 해석)

  • 최권일;장호명
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.825-834
    • /
    • 2000
  • A heat exchanger analysis is performed to investigate the heating characteristics of cryogenic nitrogen by ambient air for the purpose of cryogenic automotive propulsion. The heat exchanger is a concentric triple-passage for supercritical nitrogen, and the radial fins are attached on the outermost tube for the crossflow of ambient air. The temperature distribution is calculated for the nitrogen along the passage, including the real gas properties of nitrogen, the fluid convections and the conductions through the tube walls and the fins. Since the wall temperature of the outer (ambient side) tube is very low in most cases, a heavy frost can be formed on the surface, affecting the heat exchange performance. By the method of the similarity between the heat and the mass transfer of moist air, the frost growth and the time-dependent effectiveness of the heat exchanger are calculated for various operating conditions. It is concluded that the frost formation can augment the heating of nitrogen during the initial period because of the latent heat, then gradually degrades the heat exchange because of the increased thermal resistance. Practical design issues are discussed for the flow rate of nitrogen, the velocity and humidity of ambient air, and the sizes of the fin.

  • PDF

Effect of Thawing Methods and Storage Periods on the Quality of Frozen Cooked Rice

  • Oh, Myung-Suk
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.3
    • /
    • pp.234-240
    • /
    • 1998
  • This study attempted to determine the effect of various thawing methods and storage periods on the quality of froen cooked rice. Frozen cooked rice was thawed at four different methods, such as pressure cooking, conventional cooking, microwave heating and thawing at room temperature after 10 days, 30days and 90 days frozen storage. We conducted a physico-chemical analysis (moisture content, dehydration rates, degree of gelatinization, color value and texture) and sensory evalution on the frozen-thawed cooked rice. The study showed that there were no significant differences on the quality characteristics of frozen-thawed cooked rice during the storage period of 90 days. However, the thawing method of pressure cooking caused high moisture content, rapid dehydration rates, and a high degree of gelatinization on the cooked rice. Thus, the desirabililty for the rice diminished becaused of the excess moisture content and the change of appearance and testure in the rice due to the high temperature. There were similiar quality characteristics to the cooked rice after forzen-thawing whether by conventional cooking or by microwave heating and just after cooking. Thawing at room temperature also caused a significant decrease in quality characteristics.

  • PDF

A Study on Laser-Assisted Machining Process of Silicon Nitride (질화규소의 Laser-Assisted Machining 공정에 관한 연구)

  • Lim, Se-Hwan;Lee, Jae-Hoon;Shin, Dong-Sig;Kim, Jong-Do;Kim, Joo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.48-56
    • /
    • 2009
  • In this paper, laser-assisted machining(LAM) has been employed to machine hot isostatically pressed (HIPed) Si3N4 work pieces. Due to little residual flaws and porosity, HIPed $Si_3N_4$ work pieces are more difficult to machine compared to normally sintered $Si_3N_4$ workpieces. In LAM, the intense energy of laser was used to enhance machinability by locally heating the workpiece and thus reducing yield strength. In experiments, the laser power ranges from 200W to 800W and the diameter of work pieces is 16mm. While machining, the surface temperature was kept nearly constant by laser heating except for a short period of rise time of max. 58 seconds. Results showed as feed rate increases the surface temperature of $Si_3N_4$ workpieces decreases slightly, whereas the effect of depth of cut is disregardable. With a laser power of 800W, achievable maximal depth of cut as 0.7mm and feed rate was 0.03mm/rev.

Comparative Analysis of Weather Data for Heating and Cooling Load Calculation in Greenhouse Environmental Design (온실의 냉난방부하 산정을 위한 외부기상자료 비교분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.174-180
    • /
    • 2014
  • Standard weather data available to greenhouse environmental design are limited in most regions of the country. So, instead of using standard weather data, in order to find the method to build design weather data for greenhouse heating and cooling, design outdoor weather conditions were analyzed and compared by TAC method and frequency analysis using climatological normal and thirty years from 1981 to 2010 hourly weather data provided by KMA and standard weather data provided by KSES. Average TAC values of outdoor temperature, relative humidity and insolation using thirty years hourly weather data showed a good agreement with them using standard weather data. Therefore, in regions which are not available standard weather data, we suggest that design outdoor weather conditions should be analyzed using thirty years hourly weather data. Average of TAC values derived from every year hourly weather data during the whole period can be established as environmental design standards, and also minimum and maximum of them can be used as reference data.

A Study on the Relationship of Air Pollution and Meteorological Factors : Focusing at Kwanghwamun in Seoul (대기오염농도와 기상인자의 관련성 연구: 서울 광화문지점을 중심으로)

  • 신찬기;한진석;김윤신
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.213-220
    • /
    • 1992
  • Simple correlation analysis, factor analysis, and multi-variate analysis have been performed to analyze the relationship between air pollution and meteorological factors for air pollution and meteorological data measured at Kwanghwamun in Seoul during the period of one year(January 1990 $\sim$ December 1990). As a result of simple correlation and factor analysis, $SO_2$, TSP and CO concentrations have shown high negative correlation with temperature and among these indicating that these are related with pollutant emission trend based upon heating fuel usage. Ozone has a good corrleation with solar radiation and relative humidity to have a closed relation with $O_3$ generation reaction mechanism. The result of multi-variate correlation analysis shows that the concentration of $SO_2$ and CO are adequate for correlation model with ambient temperature and wind speed and $O_3$ concentrations are adequate for that with solar radiation and wind speed. $SO_2$ and CO levels are considered to be affected first of all by heating fuel usage as a emssion source and wind speed as a dispersion effect. The $SO_2$ concentration in the condition that the temperature fall below zero is explained by multilicative model with wind speed, only one variable.

  • PDF

Effects of Flavonoids and a-Tocopherol on the Oxidation of n-3 Polyunsaturated Fatty Acids -1. Inhibition of Fish Oil Oxidation by Heating and During Storage- (n-3고도 불포화 지방산의 산화억제에 미치는 플라보노이드와 a-토코페롤의 효과 -1. 정제어유의 가열 및 저장 중 산화억제 효과-)

  • JUNG Dong-Yun;KWON Mi-Na;HONG Jeong-Hwa;BYUN Dae-Seok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.2
    • /
    • pp.155-165
    • /
    • 1994
  • To evaluate the antioxidant effect of flavonoids and a-tocopherol on purified fish oil(up to $40\%$ of n-3 polyunsaturated fatty acids), lipid peroxidation, and fatty acids content during storage and upon heating were determined. The potential of these compounds for inhibiting and delaying both oxidation and lipoxygenase processes was also evaluated. The oxidation of fish oil was effectively inhibited by flavonoids and a-tocopherol. The antioxidizing effect of these compounds increased in proportion to their concentration. The addition of a-tocopherol and catechin-a-tocopherol mixture were prolonged induction period of lipid oxidation by 3.5 to 4 times. All other flavonoids also shown more than twice the prolonging effect. Lipoxygenase activity was decreased by catechin and a-tocopherol effectively.

  • PDF

Analysis of the Phase Change Temperatures and the Latent Heat Characteristics of $H_2O$-NaCl Mixtures for the Cold thermal Energy Storage (냉축열을 위한 $H_2O$-NaCl 혼합물의 상변화 온도와 잠열 특성분석)

  • Song, H.K.;Ro, J.G.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.57-65
    • /
    • 1999
  • In this study $H_2O$-NaCl mixture was selected as a cold thermal storage material and its phase change temperature($liquid{\Leftrightarrow}solid$) was controlled with the molar concentration of NaCl. Ion dipole interaction mechanism and the fusion and crystallization structure of $H_2O$-NaCl were visualized with the low and high concentration of NaCl in the heating and cooling processes. In this study, the original cause of the appearance of two steps phase change period in heating and cooing processes were found by the visualization of the ion dipole interaction mechanism of $H_2O$-NaCl, and the theoretical equation of the phase change temperature variation in the NaCl high molar concentration was rearranged.

  • PDF