• Title/Summary/Keyword: Heating Condition

Search Result 1,300, Processing Time 0.037 seconds

Design of Thermo-optic Switch with Low Power Consumption by Electrode Optimization (전극 구조의 최적화를 통한 저전력 열광학 스위치 설계)

  • Choi, Chul-Hyun;Kong, Chang-Kyeng;Lee, Min-Woo;Sung, Jun-Ho;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.266-271
    • /
    • 2009
  • We designed a thermo-optic switch based on a directional coupler with not only a high extinction ratio but also significantly low power consumption. The switch operates by using the thermo-optic effect of the polymer which the refractive index changes by heating the electrode. If the electrode is not powered (OFF), the input light will be coupled completely to the other waveguide. When the electrode is powered at a certain level (ON), input light launched into the input waveguide will remain in that waveguide due to the lower index adjusted in the other waveguide. The switch based on the directional coupler was designed using the generalized extinction ratio curve and the lateral shift of the input waveguide. The coupling length is 1,610 ${\mu}m$ and the extinction ratios are -28 and -30 dB for ON and OFF states, respectively. The electrode structures were optimized by thermal analysis. The transported heat into the waveguide is increased, as the electrode width (w) is increased and the center distance between the electrode and the waveguide (d) is decreased. Also, because the heat generated in the electrode affects the other waveguide, the temperature difference between two waveguides is varied as the given w and d. There are specific conditions which have the maximum of the temperature difference. That of the temperature difference is increased as the width and the temperature of the electrode are increased. Especially, when the switch is designed using the condition with the maximum of the temperature difference for switching, the temperature of the electrode can be decreased. We expect this condition will be the novel method for the reduction of the power consumption in a thermo-optic switch.

On Securing Continuity of Long-Term Observational Eddy Flux Data: Field Intercomparison between Open- and Enclosed-Path Gas Analyzers (장기 관측 에디 플럭스 자료의 연속성 확보에 대하여: 개회로 및 봉폐회로 기체분석기의 야외 상호 비교)

  • Kang, Minseok;Kim, Joon;Yang, Hyunyoung;Lim, Jong-Hwan;Chun, Jung-Hwa;Moon, Minkyu
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.3
    • /
    • pp.135-145
    • /
    • 2019
  • Analysis of a long cycle or a trend of time series data based on a long-term observation would require comparability between data observed in the past and the present. In the present study, we proposed an approach to ensure the compatibility among the instruments used for the long-term observation, which would allow to secure continuity of the data. An open-path gas analyzer (Model LI-7500, LI-COR, Inc., USA) has been used for eddy covariance flux measurement in the Gwangneung deciduous forest for more than 10 years. The open-path gas analyzer was replaced by an enclosed-path gas analyzer (Model EC155, Campbell Scientific, Inc., USA) in July 2015. Before completely replacing the gas analyzer, the carbon dioxide ($CO_2$) and latent heat fluxes were collected using both gas analyzers simultaneously during a five-month period from August to December in 2015. It was found that the $CO_2$ fluxes were not significantly different between the gas analyzers under the condition that the daily mean temperature was higher than $0^{\circ}C$. However, the $CO_2$ flux measured by the open-path gas analyzer was negatively biased (from positive sign, i.e., carbon source, to 0 or negative sign, i.e., carbon neutral or sink) due to the instrument surface heating under the condition that the daily mean temperature was lower than $0^{\circ}C$. Despite applying the frequency response correction associated with tube attenuation of water vapor, the latent heat flux measured by the enclosed-path gas analyzer was on average 9% smaller than that measured by the open-path gas analyzer, which resulted in >20% difference of the sums over the study period. These results indicated that application of the additional air density correction would be needed due to the instrument heat and analysis of the long-term observational flux data would be facilitated by understanding the underestimation tendency of latent heat flux measurements by an enclosed-path gas analyzer.

Background effect on the measurement of trace amount of uranium by thermal ionization mass spectrometry (열이온화 질량분석에 의한 극미량 우라늄 정량에 미치는 바탕값 영향)

  • Jeon, Young-Shin;Park, Yong-Joon;Joe, Kih-Soo;Han, Sun-Ho;Song, Kyu-Seok
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.487-494
    • /
    • 2008
  • An experiment was performed for zone refined Re-filament and normal (nonzone refined) Re-filament to reduce the background effect on the measurement of low level uranium samples. From both filaments, the signals which seemed to come from a cluster of light alkali elements, $(^{39}K_6)^+$, $(^{39}K_5+^{41}K)^+$ and $PbO_2$ were identified as the isobaric effect of the uranium isotopes. The isobaric effect signal was completely disappeared by heating the filament about $2000^{\circ}C$ at < $10^{-7}$ torr of vacuum for more than 1.5 hour in zone refined Refilaments, while that from the normal Re-filaments was not disappeared completely and was still remained as 3 pg. of uranium as the impurities after the degassing treatment was performed for more than 5 hours at the same condition of zone refined filaments. A threshold condition eliminating impurities were proved to be at 5 A and 30 minutes of degassing time. The uranium content as an impurity in rhenium filament was checked with a filament degassing treatment using the U-233 spike by isotope dilution mass spectrometry. A 0.31 ng of U was detected in rhenium filament without degassing, while only 3 pg of U was detected with baking treatment at a current of 5.5 A for 1 hr. Using normal Re-filaments for the ultra trace of uranium sample analysis had something problem because uranium remains to be 3 pg on the filament even though degassed for long hours. If the 1 ng uranium were measured, 0.3% error occurred basically. It was also conformed that ionization filament current was recommended not to be increased over 5.5 A to reduce the background. Finally, the contents of uranium isotopes in uranium standard materials (KRISS standard material and NIST standard materials, U-005 and U-030) were measured and compared with certified values. The differences between them showed 0.04% for U-235, 2% for U-234 and 2% for U-236, respectively.

A STUDY ON THE IONOSPHERE AND THERMOSPHERE INTERACTION BASED ON NCAR-TIEGCM: DEPENDENCE OF THE INTERPLANETARY MAGNETIC FIELD (IMF) ON THE MOMENTUM FORCING IN THE HIGH-LATITUDE LOWER THERMOSPHERE (NCAR-TIEGCM을 이용한 이온권과 열권의 상호작용 연구: 행성간 자기장(IMF)에 따른 고위도 하부 열권의 운동량 강제에 대한 연구)

  • Kwak, Young-Sil;Richmond, Arthur D.;Ahn, Byung-Ho;Won, Young-In
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.2
    • /
    • pp.147-174
    • /
    • 2005
  • To understand the physical processes that control the high-latitude lower thermospheric dynamics, we quantify the forces that are mainly responsible for maintaining the high-latitude lower thermospheric wind system with the aid of the National Center for Atmospheric Research Thermosphere-Ionosphere Electrodynamics General Circulation Model (NCAR-TIEGCM). Momentum forcing is statistically analyzed in magnetic coordinates, and its behavior with respect to the magnitude and orientation of the interplanetary magnetic field (IMF) is further examined. By subtracting the values with zero IMF from those with non-zero IMF, we obtained the difference winds and forces in the high-latitude 1ower thermosphere(<180 km). They show a simple structure over the polar cap and auroral regions for positive($B_y$ > 0.8|$\overline{B}_z$ |) or negative($B_y$ < -0.8|$\overline{B}_z$|) IMF-$\overline{B}_y$ conditions, with maximum values appearing around -80$^{\circ}$ magnetic latitude. Difference winds and difference forces for negative and positive $\overline{B}_y$ have an opposite sign and similar strength each other. For positive($B_z$ > 0.3125|$\overline{B}_y$|) or negative($B_z$ < -0.3125|$\overline{B}_y$|) IMF-$\overline{B}_z$ conditions the difference winds and difference forces are noted to subauroral latitudes. Difference winds and difference forces for negative $\overline{B}_z$ have an opposite sign to positive $\overline{B}_z$ condition. Those for negative $\overline{B}_z$ are stronger than those for positive indicating that negative $\overline{B}_z$ has a stronger effect on the winds and momentum forces than does positive $\overline{B}_z$ At higher altitudes(>125 km) the primary forces that determine the variations of tile neutral winds are the pressure gradient, Coriolis and rotational Pedersen ion drag forces; however, at various locations and times significant contributions can be made by the horizontal advection force. On the other hand, at lower altitudes(108-125 km) the pressure gradient, Coriolis and non-rotational Hall ion drag forces determine the variations of the neutral winds. At lower altitudes(<108 km) it tends to generate a geostrophic motion with the balance between the pressure gradient and Coriolis forces. The northward component of IMF By-dependent average momentum forces act more significantly on the neutral motion except for the ion drag. At lower altitudes(108-425 km) for negative IMF-$\overline{B}_y$ condition the ion drag force tends to generate a warm clockwise circulation with downward vertical motion associated with the adiabatic compress heating in the polar cap region. For positive IMF-$\overline{B}_y$ condition it tends to generate a cold anticlockwise circulation with upward vertical motion associated with the adiabatic expansion cooling in the polar cap region. For negative IMF-$\overline{B}_z$ the ion drag force tends to generate a cold anticlockwise circulation with upward vertical motion in the dawn sector. For positive IMF-$\overline{B}_z$ it tends to generate a warm clockwise circulation with downward vertical motion in the dawn sector.

Prophylactic and therapeutic studies on intestinal giant-cystic disease of the Israel carp caused by Thelophanellus kitauei II. Effects of physical and chemical factors on T. kitauei spores in vitro (향어의 장포자충(Thelohanellus kitauei)증의 예방 및 치료에 관한 기초적 연구 II. 물리화학적 요인이 장포자충 포자에 미치는 영향)

  • Lee, Jae-Gu;Kim, Jong-O;Park, Bae-Geun
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.4
    • /
    • pp.241-252
    • /
    • 1990
  • In a basic attempt to develop the prophylactic and therapeutic measures on intestinal giantcystic disease of the Israel carp, C), prinks carpio nudum, the effects of physical and chemical factors on viability or survival of the spores of Thelchcnellus kiteuei were checked in vitro by means of extrusion test on the polar filament. When the fresh spores suspended with 0.45% and 0.9% scdium chloride solution and distilled water were laid at $5^{\circ}C$ and $28^{\circ}C$ for short terms, the extrusion rates increased until the 3rd day, meanwhile when son;e of them were suspended with Tyrode's solution at $-70^{\circ}C$ the rates increased gradually until the 8th day. Viabilities of the spores suspended with 0.9% saline and added antibiotics to the suspension at $5^{\circ}C$ for long terms lasted for 997 days and 1, 256 days (presumed values) at maximum, respectively. The spores suspended with distilled water at $28^{\circ}C$ for long terms survived 152.4 days, but the spores suspended with Tyrode's solution at $-70^{\circ}C$ for long terms showed almost the same viable pattern as early freezing stages up to 780 days. The spores suspended with Tyrode's solution, frozen at $-70^{\circ}C$ and thawed at $5^{\circ}C$, showed the highest rate of extrusion of the polar filament. In the case of frozen spores, the extrusion rates during heating tend to become higher in accordance with the increase of frozen period, and the critical points of 180 day-frozen spores to be killed were generally 78.5 hr. at $60^{\circ}C$, 23.4 hr. at $70^{\circ}C$, 189.1 min. at $80^{\circ}C$ or 10.5 min. at $90^{\circ}C$. The longer the spores were frozen, the more time was needed for the death of spores after thawing; 20 days-17.4 days, 100 days-33.2 days, and 400 days-37.8 days. The longer the spores were frozen, the more time was needed for the death of spores at a conventional when they were dried air drying condition, 540 days-23.5 days, 160 days-21.0 days, and 20 days-14.4 days. On the other hand, the longer the spores were frozen, the more spores were dead rapidly when they were irradiated with 10W UV-ray; 100 days-26.0 hr, 300 days-21.9 hr, and 540 days-13.9 hr. The time needed for killing 200 days-frozen spores by various disinfectants at 1, 000 ppd was 5.2 min. by calcium oxide, 10.4 min. by potassium permanganate, 27.8 min. by malachite green and 14.3 hr. by formalin. Transient inhibitory effects of the extrusion of the polar filament were observed by various antiprotozoal and antifungal agents in the descending order of ketoconazole. metronidasole and dapsone. The above results presume that full drying, followed by spraying CaO and maintaining sunny condition for a few days on the concrete bottoms of knish farm may be an effective method for the prevention of intestinal giant.cystic disease.

  • PDF

Analysis of Critical Control Points through Field Assessment of Sanitation Management Practices in Foodservice Establishments (현장실사를 통한 급식유헝별 위생관리실태 분석)

  • Kwak Tong-Kyung;Lee Kyung-Mi;Chang Hye-Ja;Kang Yong-Jae;Hong Wan-Soo;Moon Hye-Kyung
    • Korean journal of food and cookery science
    • /
    • v.21 no.3 s.87
    • /
    • pp.290-300
    • /
    • 2005
  • Increased sanitation management of foodservice establishments is required because most of the reported foodborne-disease outbreaks were in the foodservice industry. The purpose of this study was to determine the important control points for good sanitation. In this study, we inspected twenty foodservice establishments in Seoul, Kyunggi, Kyungnam with a self-developed monitoring tool. These foodservice establishments included secondary schools, universities, and industries. Six of them had appointed as the HACCP-certified establishments from the Korea Food and Drug Administration. The inspection was conducted from June to August in 2002. The inspection tool consisted of nine dimensions and sixty-five items. The dimensions were 'personal sanitation', 'supply of raw food', 'food storage', 'handling of raw food and ready-to-eat', 'cleaning and sterilization', 'waste control', 'pest control', and 'control of establishment and equipment' The highest possible score of this inspection tool is 105 points. Statistical data analysis was completed using the SPSS Package(11.0) for descriptive analysis Kruskal-Wallis. The score for the secondary schools (83.6 points) was higher than for the others and number of in compliance item was 50.9 on average. Therefore, we concluded that the secondary schools' sanitation condition was good. The foodservice establishments acquired HACCP certification was 89.7 points, which was significantly higher than that of establishments not applying foodservices in total score. Instituting the HACCP system in a foodservice is very effective for sanitation management. Many out of the compliance observations were found in the dimensions of 'waste control', 'control of establishment and equipment', and 'supply of raw food' 'Clean condition of refrigerator' item was $65\%$ out of the compliance that was the highest percent in this study. 'Notify and observance of heating/reheating temperature' was $45\%$ out of compliance. Items which were over $30\%$ out of compliance were 'sterilization of knifes and chopping boards in cooking', 'education of workers', 'maintain refrigerator temperature blow $5^{\circ}C$', and 'countermeasure of infection workers' In the results, most of the foodservice establishments were poorly managed in temperature control and cross-contamination. The important control points revealed in this study were preventing contamination, cooking temperature compliance, management of raw food and refrigerator. Therefore foodservice establishments should pay attention to education and training about important control points. The systematic sanitation management monitoring tool developed in this study can be effectively applied for conducting self-inspection and improving the sanitary conditions of their own foodservice operations.

Antioxidant and Antibacterial Activities of Glycyrrhiza uralensis Fisher (Jecheon, Korea) Extracts Obtained by various Extract Conditions (한국 제천 감초(Glycyrrhiza uralensis Fisher)의 추출 조건별 추출물의 항산화 및 항균 활성 평가)

  • Ha, Ji Hoon;Jeong, Yoon Ju;Seong, Joon Seob;Kim, Kyoung Mi;Kim, A Young;Fu, Min Min;Suh, Ji Young;Lee, Nan Hee;Park, Jino;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.4
    • /
    • pp.361-373
    • /
    • 2015
  • This study was carried out to evaluate the antioxidant and antibacterial activities of Glycyrriza uralensis Fisher (Jecheon, Korea) extracts obtained by various extraction conditions (85% ethanol, heating temperatures and times), and to establish the optimal extraction condition of G. uralensis for the application as cosmetic ingredients. The extracts obtained under different conditions were concentrated and made in the powdered (sample-1) and were the crude extract solutions without concentration (sample-2). The antioxidant effects were determined by free radical scavenging activity ($FSC_{50}$), ROS scavenging activity ($OSC_{50}$), and cellular protective effects. Antibacterial activity was determined by minimum inhibitory concentration (MIC) on human skin flora. DPPH free radical scavenging activity of sample-1 ($100{\mu}g/mL$) was 10% higher in group extracted for 6 h than 12 h, but sample-2 didn't show any significant differences. The extraction yield extracted with same temperature for 12 h was 2.6 times higher than 6 h, but total flavonoid content was 1.1 times higher. These results indicated that total flavonoid content hardly increased with increasing extraction time. Free radical scavenging activity, ROS scavenging activity and cellular protective effects were not dependent on the yield of extraction, but total flavonoid content of extraction. Antibacterial activity on three skin flora (S. aureus, B. subtilis, P. acnes)of sample-1 in different extraction conditions were evaluated on same concentration, and the group extracted at 25 and $40^{\circ}C$ showed 16 times higher than methyl paraben ($2,500{\mu}g/mL$). In conclusion, 85% ethanol extracts of G. uralensis extracted at $40^{\circ}C$ for 6 h showed the highest antioxidant and antibacterial activity. These results indicate that the extraction condition is important to be optimized by comprehensive evaluation of extraction yield with various conditions, yield of active component, and activity test with concentrations, and activity of 100% extract, for manufacturing process of products.

Mineralogical Study on the Clay Formation and Heavy Metal Speciation in the Acidified Soil Profile of the Onsan Industrial Area (온산공업지역 산성 토양 프로화일 내에서의 점토광물의 생성과 중금속 이온의 거동에 관한 광물학적 연구)

  • 이상수;김수진
    • Journal of the Mineralogical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • The present study is focused on the granite weathering and soil formation, and the heavy metal contamination in soils in the Onsan industrial area. For profile study, soil sampling was conducted on each depth and experimental analyses have been conducted on those samples. X-ray diffraction analyses show that clay minerals consist mainly of kaolin minerals, vermiculite, and minor illite. Most of kaolin minerals in the lower kiwi of the profile consist of halloysite as confirmed by formamide intercalation, but the content of halloysite decreases gradually toward the surface since it has been transformed to kaolinite in the upper part of the profile. Thermal treatment by heating at $110^{\circ}C,\;300^{\circ}C,\;and\;550^{\circ}C$ shows a diffuse and broad peak the between 10 and $14\;{\AA}$ region in X-ray diffractograms. This suggests the possible existence of the hydroxy-Al interlayerecl vermiculite. Na-citrate extraction method reaconfirms this result showing transition of $14\;{\AA}$ peak to $10\;{\AA}$ In by removing the interlayer materials and restoring the vermiculite to its original state. The occurrence of hydroxy-Al interlayered vermiculite is also supported by soil pH distribution room 3.9 In the lower part to 3.6 in the upper part of the profile. Sequential extraction experiment was conducted to investigate the states of heavy metals in soils. The experiment shows that relatively high amounts of heavy metals are concentrated in the upper part of the profile and that most of them are bound to Fe/Mn oxides and organic matters while less concentration in clay minerals. The result indicates that most of heavy metal pollutants are concentrated in the surface soil and that the low concentrations of heavy metals in clays are mainly due to the low adsorption capacities of clay minerals such as kaolin minerals and hydroxy-Al interlayered vermiculite in acidified soil condition.

Studies on the Direct Sowing Culture of Rice in Reclaimed Paddy Field (간척답 벼 직파재배에 관한 연구)

  • Lee, Seok-Su;Shim, Jae-Sung
    • The Journal of Natural Sciences
    • /
    • v.5 no.2
    • /
    • pp.49-62
    • /
    • 1992
  • This study was carried out to investigate the emergence, growth and yield components in rice inassoccation with Several cultivation methods direct sowing flooded paddy field(DSF), direct sowing by airplane(DSA), direct sowing in dry paddy field(DSD), 8days seedling planting(8DS), and 35days seedlingplanting(35DS). Also this study was attempeted to know the effects of calcium peroxide on germinationand early growth of rice under different soil conditions, seeding depth, application of organic matter,indirect sowing flooded paddy field.1. Rate of emergence was 73% in DSF, 70% in DSA, 62% in DSD, respectively, under the different cultivation method of rice in reclaimed paddy field.2. Degree of lodging in relation to cultivation was 5 at both DSF and DSA, 3 at DSD, 2 at both 8DS and 35DS respectively.3. Maximum tiller number was 568 per m2 at DSF and 527 at DSA. Heating was delayed for 4 days at DSF, 8 days at DSD and 2 days at 8DS as comparison with that at 35DS.4. Yield was higher 1% to 3% at DSF than that at DSA and DSD while decreased by 12% as compared with that of seedling planting.5. Total dry weight of seedling was decreased by 57% at 8DS, 60% at DSF 63% at DSD, respectively, under 0.3% of salinity. Ratio of decreasing in dry weight was higher with high salinity.6. The amount of O2 released was recorded highest to 2 to 3days after irrigatition, thereafter remaining constant to 10 days after irrigatition.7. The optimum coating amount of calcium peroxide for germination was a half of rice seed weight with 1 cm sowing depth and one-fold with 2-cm sowing depth when rice straw was not applied. With rice straw applied, on the other hand, the amount of peroxide was one-fold with 1-cm sowing depth. It was found that, under the condition of applied 600kg/10a, of 2-cm soil depth with rice straw calcium peroxide coating had no effect on emergence of rice seedling.8. In reclaimed paddy field, lodging degree was 7 with direct sowing by machine and 9 with direct sowing by hand.9. Yield was increased by 5% by applying rice straw with direct sowing by machine.

  • PDF

Toxin Profile in the Liver of Puffer Fish, Takifugu niphobles, and Changes in Mouse Toxicity by pH and Heating Conditions (복섬 간장의 독성분과 pH 및 가열 조건에 따른 독성의 변화)

  • Jang, Jun-Ho;Yun, So-Mi;Kim, Jung-Soo;Lee, Jong-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.5
    • /
    • pp.612-617
    • /
    • 2008
  • Tetrodotoxin (TTX) analogues were first determined from the liver extracts of puffer fish, Takifugu niphobles, by LC/MS with Hydrophilic Interaction Liquid Chromatography (HILIC). In total, 7 TTX analogues were detected within 20 minutes as follows; 5,6,11-trideoxyTTX (34.0%, 1,029.6 nmol/g), 6,11-dideoxyTTX (29.3%, 887.6 nmol/g), TTX (22.1%, 667.8 nmol/g), 4,9-anhydro-TTX (11.2%, 339.3 nmol/g), 11-deoxyTTX+5-deoxyTTX (2.6%, 78.6 nmol/g), and 4-epiTTX (0.8%, 23.6 nmol/g). Mouse toxicity of diluted liver extracts showed the highest toxicity at pH 3 (8.7 MU/mL) and decreased, as increasing pH, to 1.4 MU/mL at pH 10. At acidic (pH 5) and neutral conditions (pH 7), mouse toxicity of liver extracts (79 MU/mL) decreased slowly, as increasing temperature from $80^{\circ}C$ to $115^{\circ}C$, and time until 1 hour; in contrast, at the akaline condition (pH 9), the toxicity decreased rapidly to the more than half within 10 minutes. Individual toxicity of the fillet of T. niphobles were between $43.2{\sim}106.7$ MU, and $64{\sim}78%$ of its toxicity was eluted to soup when boiled with 3 volumes of water during 10 minutes.