• Title/Summary/Keyword: Heating Condition

Search Result 1,302, Processing Time 0.029 seconds

Methodology for Estimating the Probability of Damage to a Heat Transmission Pipe (열수송관 파손확률 추정 방법론 개발)

  • Kong, Myeongsik;Kang, Jaemo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.11
    • /
    • pp.15-21
    • /
    • 2021
  • Losses of both life and property increased from damage to underground pipe such as heat transmission pipe buried underground in downtown because pipes are gradually aging. Considering the characteristics of the heat transmission pipe, which is not exposed to the outside and difficult to immediately identify problems such as damage, it is realistic to indirectly check the condition of the facility based on the historical information that is periodically collected through facility maintenance. In this study, a methodology for estimating the damage probability was developed by examining the history information of the heat transmission pipe, deriving an evaluation factor that is related to the damage probability. The contribution factor of the damage probability were reviewed by analyzing not only the guidelines for maintenance of heat transmission pipe of advanced European countries and domestic district heating companies, but also the cases of waterworks with similar characteristics. Evaluation factors were selected by considering not only the correlation with the damage probability but also the possibility of securing data. Based on 1999, when the construction technology and standards of heat transmission pipe changed, the damage probability estimation function according to the period of use was divided into the case of being buried before 1998 and the case of being buried after 1999, and presented. In addition, the damage probability was corrected by assigning weights according to the measured data for each evaluation factor such as the diameter, use, and management authority.

Mechanical Characteristics and Microstructures of Hypereutectic Al-17Si-5Fe Extruded Alloys Prepared by Rapid Solidification Process (급속응고법으로 제조한 과공정 Al-17Si-5Fe 합금 압출재의 미세조직 및 기계적 특성)

  • KIM, Tae-Jun;LEE, Se-dong;BECK, Ah-Ruem;KIM, Duck-Hyun;LIM, Su-Gun
    • Journal of Korea Foundry Society
    • /
    • v.39 no.2
    • /
    • pp.26-31
    • /
    • 2019
  • In this study, the mechanical characteristics and microstructure of hypereutectic Al-17Si-5Fe extruded alloys prepared by a rapid solidification process (RSP) were investigated. The hypereutectic Al alloy was fabricated by means of RSP and permanent casting. For RSP, the Al alloy melted at $920^{\circ}C$, cooling the specimens at a rate of $10^6^{\circ}C/s$ when the RSP was used, thus allowing the refining of primary Si particles more than when using permanent casting, at a rate of about 91%. We tested an extrusion RSP billet and a permanent-cast billet. Before the hot-extrusion process, heating to $450^{\circ}C$ took place for one hour. The samples were then hotextruded with a condition of extrusion ratio of 27 and a ram speed of 0.5 mm/s. Microstructural analyses of the extruded RSP method and the permanent casting method were carried out with OM and SEM-EDS mapping. The mechanical properties in both cases were evaluated by Vickers micro-hardness, wear resistance and tensile tests. It was found that when hypereutectic Al-17Si-5Fe alloys were fabricated by a rapid solidification method, it becomes possible to refine Si and intermetallic compounds. During the preparation of the hypereutectic Al-17Si-5Fe alloy by the rapid solidification method, the pressure of the melting crucible was low, and at faster drum speeds, smaller grain alloy flakes could be produced. Hot extrusion of the hypereutectic Al-17Si-5Fe alloy during the rapid solidification method required higher pressure levels than hot extrusion of the permanent mold-casted alloy. However, it was possible to produce an extruded material with a better surface than that of the hot extruded material processed by permanent mold casting.

The Study on Removing Paraloid B-72 from Painting Layer on Mural of Mireukjeon Hall at Geunsansa Temple (금산사 미륵전 벽화 채색층의 Paraloid b-72 제거방법과 안정성에 관한 연구)

  • Jin, Byung-Hyuk;Cho, Jae-Yeon;Park, Jin-Yeon;Han, Sung-Hee;Kim, Yong-Sun
    • Korean Journal of Heritage: History & Science
    • /
    • v.50 no.3
    • /
    • pp.88-109
    • /
    • 2017
  • As the technique to remove Paraloid B-72, which is known as an irreversible material, the method using organic solvent and heating, though the ways vary depending on the kind of material to be removed, has been usually used, but it has yet to apply to mud mural because of the technical limit in processing and the potential risk of damage and, moreover, the removal efficiency which also remains unproven. Thus, in a bid to seek the way to safely remove Paraloid B-72 contained in mural, the test was conducted in a way of applying a compress method, which is deemed most efficient. The solvents which are proven to be Paraloid B-72 were applied to the absorbents such as active carbon fiber and methyl cellulose and then were eluted to the surface of mud mural sample which was prepared in the same size and condition for a certain time before evaluating the stability and removal efficiency. Such test was intended to identify the applicability to the mural of Mireukjeon Hall at Geunsansa Temple, which had been treated with Paraloid B-72 for preservation in the past. As a result, the way of mixing the absorbent such as active carbon fiber and Xylene alone or with other quick vaporable solvents proved to be most efficient in removing Paraloid B-72 from mud mural and particularly Acetone:Xylene(1:1wt%) was found to be the most stable among others. Such a test outcome is expected to be a useful data for removing Paraloid B-72 from the mural of Mireukjeon Hall at Geunsansa Temple as well as for restoring other mural cultural assets in the coming days.

Improvement of Acid Digestion Method by Microwave for Hazardous Heavy Metal Analysis of Solid Refuse Fuel (고형연료제품의 유해중금속 분석을 위한 마이크로파 산 분해법의 개선)

  • Yang, Won-Seok;Park, Ho-Yeun;Kang, Jun-Gu;Lee, Young-Jin;Lee, Young-Kee;Yoon, Young-Wook;Jeon, Tae-Wan
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.7
    • /
    • pp.616-626
    • /
    • 2018
  • The quality standards of solid refuse fuel (SRF) define the values for 12 physico-chemical properties, including moisture, lower heating value, and metal compounds, according to Article 20 of the Enforcement Rules of the Act on Resource Saving and Recycling Promotion. These parameters are evaluated via various SRF Quality Test Methods, but problems related to the heavy metal content have been observed in the microwave acid digestion method. Therefore, these methods and their applicability need improvement. In this study, the appropriate testing conditions were derived by varying the parameters of microwave acid digestion, such as microwave power and pre-treatment time. The pre-treatment of SRF as a function of the microwave power revealed an incomplete decomposition of the sample at 600 W, and the heavy metal content analysis was difficult to perform under 9 mL of nitric acid and 3 mL of hydrochloric acid. The experiments with the reference materials under nitric acid at 600 W lasted 30 minutes, and 1,000 W for 20 or 30 minutes were considered optimal conditions. The results confirmed that a mixture of SRF and an acid would take about 20 minutes to reach $180^{\circ}C$, requiring at least 30 minutes of pre-treatment. The accuracy was within 30% of the standard deviation, with a precision of 70 ~ 130% of the heavy metal recovery rate. By applying these conditions to SRF, the results for each condition were not significantly different and the heavy metal standards for As, Pb, Cd, and Cr were satisfied.

The Study on the Power Consumption for Glass Melting by Cold Crucible Melter (CCM용융에 대한 유리용융 조건 연구)

  • Jin, Hyun-Joo;Lee, Kyu-Ho;Jung, Young-Jae;Bae, So-Young;Kim, Tae-Ho;Jung, Young-Joon;Kim, Young-Seok;Lee, Kang-Taek;Ryu, Bong-Ki
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.2
    • /
    • pp.65-68
    • /
    • 2008
  • Generally CCM (cold crucible melting) is not suitable for melting glass. However, in this study we described the quantitative relationship between the basic property of glass and power balance, the power absorption in the melt, the losses in the coil and the cold crucible, for melting glass in CCM. The dependence of power balance on the applied frequency and the electric conductivity has been found. Above 300 kHz, the glass (B) contained alkali ion which has the low resistance $3.0{\Omega}{\cdot}cm$ at $900^{\circ}C$ and $1.36{\Omega}{\cdot}cm$ at $1,100^{\circ}C$ was melted easily and 60% of the overall power was absorbed in the melt and 30% and 10% of the overall power was lost in the cold crucible and coil respectively. Under the same condition, the glass (A) contained non-alkali ion was not melted easily and 50% of the overall power was absorbed in the melt and 40% and 10% of the overall power was lost in the cold crucible and coil respectively. In conclusion, the small absorbed power of the overall power in melt prevented a successful melting as for glass A, and the successful melting depends on the relative size of the absorbed power in melt irrespective of the melting volume. Hence, as typical for direct induction heating method(CCM), the successful melting strongly depended on the chosen working frequency based on electric conductivity of glass, power balance and the control of the critical power which was absorbed in melt.

Effect of Vertically Rising Pressure Providing Spinal Canal Segment Motion on Symptom Relief in Patients with Parkinson's Disease (척추관 분절운동을 제공하는 수직 상승 압력이 파킨슨병 환자의 증상 완화에 미치는 영향)

  • Do-Hyun, Ahn;Hyeun-Woo, Choi;Kyung-Mi, Jung;Na-Young, Kim;Jong-Min, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.787-797
    • /
    • 2022
  • The purpose of this study was to confirm the reduction of pain and symptom relief of Parkinson's disease by vertically stimulating the spine through the application of a mechanical bed capable of thermal and massage stimulation. For this purpose, after confirming the segmental motion of the spine due to the use of a medical combination stimulation bed for Parkinson's disease patients, VAS, ODI, gait ability, and spiral drawing tests were performed, and the relationship between the variables was identified. In the 10-day visual analog scale and evaluation of low back pain dysfunction, the average trend of decreasing after bed use was confirmed. For walking ability, a decrease in the moving time and an increase in the moving distance were observed. In the spiral drawing test, the mean test time after using bed was significantly lower than before. As a result, it suggested the possibility of using it as an auxiliary method for recovery and pain relief of Parkinson's disease patients due to spinal segmental movement with mechanical heating and massage. However, this study is a preliminary study, and there is a small number of subjects, so additional research is needed that considers the number and condition of future subjects in detail.

Measurements of Void Concentration Parameters in the Drift-Flux Model (상대유량 모델내의 기포분포계수 측정에 관한 연구)

  • Yun, B.J.;Park, G.C.;Chung, C.H.
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.91-101
    • /
    • 1993
  • To predict accurately the thermal hydraulic behavior of light water reactors during normal or abnormal operation, the accurate estimation of the void distribution is required. Up to date, many techniques for predicting void fraction of two-phase flow systems have been suggested. Among these techniques, the drift-flux model is widely used because of its exact calculation ability and simplicity. However, to get more accurate prediction of void fraction using drift-flux model, slip and flow regime effects must be considered more properly In the drift-flux method, these two effects are accounted for by two drift-flux parameters ; $C_{o}$ and (equation omitted). At earlier stage, $C_{o}$ is measured in a circular tube. In this study, $C_{o}$ is experimentally determined by measuring local void fraction and vapor velocity distribution in a rectangular subchannel having 4 heating rods which simulates nuclear subchannels. The measurements are peformed with two-electrical conductivity probes which are known to be adequate for measuring local parameters. The experiments are performed at low flow rate and the system pressure less than 3 atmo spheric pressure. In this experiment, (equation omitted), is not measured, but quoted from well-known empirical correlation to formulate $C_{o}$. Finally, $C_{o}$ is expressed as a function of channel averaged void fraction. fraction.

  • PDF

A Study on Atmospheric Turbulence-Induced Errors in Vision Sensor based Structural Displacement Measurement (대기외란시 비전센서를 활용한 구조물 동적 변위 측정 성능에 관한 연구)

  • Junho Gong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.1-9
    • /
    • 2024
  • This study proposes a multi-scale template matching technique with image pyramids (TMI) to measure structural dynamic displacement using a vision sensor under atmospheric turbulence conditions and evaluates its displacement measurement performance. To evaluate displacement measurement performance according to distance, the three-story shear structure was designed, and an FHD camera was prepared to measure structural response. The initial measurement distance was set at 10m, and increased with an increment of 10m up to 40m. The atmospheric disturbance was generated using a heating plate under indoor illuminance condition, and the image was distorted by the optical turbulence. Through preliminary experiments, the feasibility of displacement measurement of the feature point-based displacement measurement method and the proposed method during atmospheric disturbances were compared and verified, and the verification results showed a low measurement error rate of the proposed method. As a result of evaluating displacement measurement performance in an atmospheric disturbance environment, there was no significant difference in displacement measurement performance for TMI using an artificial target depending on the presence or absence of atmospheric disturbance. However, when natural targets were used, RMSE increased significantly at shooting distances of 20 m or more, showing the operating limitations of the proposed technique. This indicates that the resolution of the natural target decreases as the shooting distance increases, and image distortion due to atmospheric disturbance causes errors in template image estimation, resulting in a high displacement measurement error.

Design of Aerosol Generator for Inhalation Toxicology Study of Lead and Evaluation with Real Time Monitoring (납의 흡입독성 연구를 위한 에어로졸 발생장치의 고안 및 실시간 모니터링을 이용한 성능평가)

  • Jeung Jae Yeal;Kim Jung Man;Kim Tae Hyeung;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.2
    • /
    • pp.373-379
    • /
    • 2002
  • This paper was the design of aerosol generator for inhalation toxicology study of lead and evaluation with real time monitoring, and applied several engineering methodology to classical aerosol generator to cope with it's disadvantages. According to the testing conditions, source temperature 50℃ and inlet-duct band heater temperature 150℃, aerosol generation results for sodium chloride and lead acetate were as followings: CPM(Count Per Minute) for Sodium chloride that used for the testing material in aerosol generation and inhalation system was decreased in the 2nd and the 3rd hour's serial trials, but CVs(coefficient of variation) were maintained within 10%. CPMs for 5 and 2.5 gram of lead acetate that used for aerosol generation and inhalation exposure of lead showed similar results because of the sedimentation of lead acetate on piezoelectric crystal with time. For that reason, heating and mixing of nebulizing solution will be needed to generate lead aerosol with stable profile and maximum generation efficiency. Fluctuations of 10 and 5 gram lead acetate were low but 2.5gram was high. However, CVs for 10, 5, and 2.5gram lead acetate were within 10%. Considering the theoretical efficiencies for sodium chloride and lead acetate, 5gram sodium chloride and 2.5gram lead acetate were appropriate choice. Aerosol generation characteristics for two materials with 1 hour interval were different with respect to the fluctuation of CPM and the decrease to 10gram in it's material. For that reason, sodium chloride can not be used to estimate the aerosol generation and it's related parts for lead acetate. According to the testing conditions, source temperature 20, 50, 70℃, and inlet-duct band heater temperature 20, 50, 100, 150, 200℃, aerosol generation results for sodium chloride and lead acetate were as followings: Excluding inlet-duct band temperature 200℃, maximum CPM for sodium chloride was manifested in source temperature 70℃ with each inlet-duct band temperature conditions. We suggest that this condition was the optimum in the design of aerosol generator, inhalation system, and the testing. Maximum CPMs for 10, 5, and 2.5gram sodium chloride were from source temperature 70℃ and inlet-duct band temperature 20℃. Excluding inlet-duct band temperature 50, 200℃, maximum CPMs for lead acetate were indicated in source temperature 50℃ with each inlet-duct band temperature conditions. We suggest that this condition was the optimum in the design of aerosol generator, inhalation system, and the testing for lead inhalation study. Source and inlet-duct band temperatures for 10, 5, 2.5gram lead acetate were 50 and 100℃, 50 and 100℃, 50 and 150℃, respectively. In conclusion, considering above 2 paragraphs of results for aerosol generation, 5gram efficiencies for sodium chloride, lead acetate were higher than 2.5gram's. If inlet-duct band temperature was same, aerosol generation was increased with increase of source temperature. To get maximum aerosol generation will be the conditions that set the appropriate inlet-duel band temperature for each materials and increase the source temperature.

Effect of Soil Temperature on the Emergence - Speed of Rice and Barnyardgrasses under Dry Direct - Seeding Condition (토양온도(土壞溫度)가 벼와 피의 출아속도(出芽速度)에 미치는 영향(影響))

  • Kwon, Y.W.;Kim, D.S.;Park, S.W.
    • Korean Journal of Weed Science
    • /
    • v.16 no.2
    • /
    • pp.81-87
    • /
    • 1996
  • Seeds of rice, cv. Ilpoom, and barnyardgrasses(Echinochloa crus-galli, vars. oryzicola, crux-galli, and praticola) were sown for a characterization of their responses to temperature during emergence under a dry direct-seeded condition. A laboratory-made aluminum block apparatus for emergence-temperature control conferred a linear continuous temperature gradient from 10 to $30^{\circ}C$ to the seeds from cooling to heating ends of the apparatus. The lowest temperature for emergence was $12.3^{\circ}C$ for rice cv. Ilpoom, and $11.0^{\circ}C$ for the three varieties of Echinochloa spp.. Percent emergence of rice increased sharply with an increase in temperature by ca. $20^{\circ}C$, then leveled-off, while those of barnyardgrasses increased almost linearly with temperatures up to $30^{\circ}C$. In rice the time required for emergence after seeding was shortened exponentially with increased temperature while those for barnyardgrasses were shortened almost linearly from 11 to $30^{\circ}C$. The temperature-response characteristic of rice in emergence-speed was almost the same among those for the 1st emergence, emergence by 25, 50, 75%, or average emergence time. At $13^{\circ}C$, $346.7^{\circ}C$ days of accummulated temperature(26.67 days) were required for the 1st emergence in rice while 131.7, 136.0, and $138.7^{\circ}C$ days(10.13, 10.46, and 10.67 days) were required for the 1st emergence in E. spp., vars. crus-galli, praticola, and oryzicola, respectively. Greater cold tolerance and increasingly faster emergence of barnyardgrasses than rice below $20^{\circ}C$ seem to render the barnyardgrasses as much more competitive than rice at lower temperatures.

  • PDF