• Title/Summary/Keyword: Heated Tube

Search Result 192, Processing Time 0.023 seconds

The design method of overheat protection orifice for power plant boiler super heated tube (발전용 보일러 주증기 튜브 과열방지용 오리피스 설계기법)

  • Kim, Bum-Shin;Yoo, Seong-Yeon;Ha, Jung-Su;Kim, Eui-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.373-378
    • /
    • 2003
  • It is important that overheat protection of super heated tube in boiler operation and maintenance. The overheat of super heat tube can make damage and rupture of tube material, which causes accidental shutdown of boiler. The super heated tube overheat is almost due to the lack of uniformity of gas temperature distribution. There are two ways to protect overheat of super heated tube. The one is to control hot gas operation pattern which is temperature or flow distribution. the other is to control super heated steam flow distribution. The former is difficult than the later, because of control device design. In this paper steam flow control method which uses orifices is proposed to protect overheat of super heat tube.

  • PDF

Study on The Free Convection in a Heated Vertical Open Tube (수직관내에서의 자연대류에 관한 연구)

  • ;;Kim, Hee Dong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.1 no.3
    • /
    • pp.146-155
    • /
    • 1977
  • The free convection in a vertical tube open at both ends and heated at the heated at the wall is studied by analytical approach and checked by experiment. The flow is assumed to be both stable and laminar. The incompressible boundary layer equations fot the system were solved by a finite difference method for conditions of constant wall temperature and conctant wall heat flux. Temperature profiles of the flow in the tube were measured by thermocouples and are compared with the calculated profiles. Agreement of the analytical and experimental results was good.

Study on Fresh Air Load Reduction System by Using Geothermal Energy - Reducing Effect of a Fresh Air Load by Combining with Air-heated Solar Collector - (지열을 이용한 공조외기부하저감 시스템에 관한 연구 - 공기식 집열기와의 병용에 의한 공조외기부하저감 효과 -)

  • Son Won-Tug;Lee Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1218-1226
    • /
    • 2004
  • This paper presents thermal behaviors and performances of a fresh air load reduction system by using earth tube system combined with air-heated solar collector. The earth tube system reduces a fresh air load by heat exchange with soil throughout the year. In the previous experimental research, it was clarified that the earth tube system was very useful as a fresh air load reduction system. However, since outlet temperature of the fresh air which was heated by earth tube system was below 15$^{\circ}C$ in winter, it is not suitable to introduce the fresh air into the place of residence directly. Therefore, a simulation model using the simple heat diffusion equation was used to examine a rising effect of outlet air temperature in winter by combining with air-heated solar collector. An improvement of annual performance by control of operation is also quantitatively examined. In conclusion, it is confirmed that its performance is improved by control of operation throughout the year and outlet air temperature rose by combining with air-heated solar collector.

A Study on Critical Heat Elux Characteristics in a Two-Phase Concentric-Tube Thermosyphon (2중관형 2상 열사이폰의 한계열유속 특성에 관한 연구)

  • Kim, Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1419-1426
    • /
    • 2002
  • An experimental study was made to elucidate critical heat flux(CHF) characteristics in a two-phase concentric-tube thermosyphon. The experiment was performed by using saturated water, over the experimental range of configuration: inner diameter of heated outer tube D=12mm, outer diameter of unheated inner tube do=3 to 10mm and heated tube length L=100 to 1000mm. The experiment shows that the CHF is enhanced with increase in the inner tube diameter, and that the CHF decreases beyond a certain diameter of the inner tube. There is an optimum diameter for inner tube that maximizes the CHF, for each tube length and test liquid. The CHF maximum is about two to eight times as large as that without an inner tube. For a large inner tube, the CHF characteristics is similar to that for natural convective boiling in a vertical annular tube.

A Study on Al Hot Forming Using Air Bulging (Air Bulging을 이용한 열간 알루미늄 성형에 관한 연구)

  • Park, D.H.;Kim, T.J.
    • Transactions of Materials Processing
    • /
    • v.24 no.1
    • /
    • pp.20-27
    • /
    • 2015
  • Hot tensile tests were conducted at different temperatures ranging from $20^{\circ}C$ to $550^{\circ}C$ to evaluate the mechanical properties of Al5052 seamless tubes. Such tubes can provide the technological foundation for complex forming using hot air bulging. Hot air bulging is one of the recently developed hydroforming techniques and it has some limitations in terms of cycle times. The benefits of hot air bulging are weight and cost savings through part consolidation and reduced post-forming processes such as welding and piercing. In order to extend the forming limits of Al lightweight material hot air bulging was investigated. A heated tube was placed in a heated die and sealed at the ends by sealing cylinders. The heated tube was subsequently expanded against the die cavity wall by internal pressure using air medium. The results of the current study show that axial feeding speed and air pressure have an effect on the formability of Al tubes during air bulging at elevated temperatures.

Effects of Outer Tube Length on Pool Boiling in an Annulus with Closed Bottoms (하부폐쇄 환상공간의 외부 튜브길이가 풀비등에 미치는 영향)

  • Kang Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.749-755
    • /
    • 2006
  • To improve pool boiling heat transfer in an vertical annulus with closed bottoms, the length of an outer tube has been changed from 0.2m to 0.6m. For the test, a heated tube of 19.1mm diameter and water at atmospheric pressure have been used. Annular conditions are made using glass tubes fabricated around the heated tube. The gap size of the annulus is 3.65mm. To elucidate effects of the outer tube length on heat transfer results of the annulus are compared with the data of a single unrestricted tube and the annulus with wider gap size of 6.35mm. Throughout the tests much higher heat transfer coefficients are observed for the annulus of 3.65mm gap size comparing to the other two cases. The change in the outer tube length results in much variation in heat transfer coefficients. Moreover, with shortening the length of outer tube the possibility of the CHF occurrence can be removed.

A Study on the Rewetting Phenomena of a Heated Tube by Bottom Flooding (下部注入 에 의한 加熱管 의 再水着 現象 에 관한 硏究)

  • 정문기;이영환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.1
    • /
    • pp.48-56
    • /
    • 1984
  • In order to estimate the fuel rod temperature during the reflooding phase of the PWR LOCA, it is essential to obtain a better understanding of the rewetting mechanism. This paper presents the results of analytical and experimental investigations aimed at analyzing the rewetting phenomena in a heated tube. A two-dimensional solution of the rewetting for a tube is described and used to yield the correlation of the rewetting heat transfer coefficient as the function of flooding rate and inlet subcooling. This correlation prediction is in good agreement with the experimental data.

Content Analysis of YouTube Vidoes Regarding Heated Tobacco Products: Focus on Product and Health Harm Information, and Creator Characteristics (궐련형 전자담배 YouTube 동영상 내용 분석: 제품 및 건강 유해성 정보, creator 특성을 중심으로)

  • Choi, Youjin
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.389-397
    • /
    • 2019
  • As the usage of e-cigarettes and its effects on health harms receive attentions, the debate over regulating e-cigarette industry's' social media marketing has been heated. While the industry has aggressively employed social media marketing such as YouTube, little research has examined what kinds of e-cigarette information is delivered to Korean viewers through YouTube. This study investigated the presence of product-related information and health harm information in the videos, and the characteristics of YouTube creators. The proportion of female creators was smaller than male creators, but more than female smoking rates. The results showed that product-related information such as taste, design and convenience was mentioned more than half the videos, but health ham was mentioned less. Videos which mentioned convenience and design tended to not mention health harm. These results could be used to support the current regulation approach over e-cigarette YouTube marketing.

An Experiment on Thermosyphon Boiling in Uniformly Heated Vertical Tube and Asymmetrically Heated Vertical Channel

  • Kwak, Ho-Young;Jeon, Jin-Seok;Na, Jung-Hee;Park, Hong-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.98-107
    • /
    • 2001
  • Continuing efforts to achieve increased circuit performance in electronic package have resulted in higher power density at chip and module level. As a result, the thermal management of electronic package has been important in maintaining or improving the reliability of the component. An experimental investigation of thermosyphonic boiling in vertical tube and channel made by two parallel rectangular plates was carried out in this study for possible application of the direct immersion cooling. Fluorinert FC-72 as a working fluid was used in this experiment. Asymmetric heated channel of open periphery with gap size of 1, 2, 4 and 26mm and uniformly heated vertical tubes with diameter of 9, 15 and 20mm were boiled at saturated condition. The boiling curves from tested surfaces exhibited the boiling hysteresis. It was also found that the gap size is not a significant parameter for the thermosyphonic boiling heat transfer with this Fluorinert. Rather pool boiling characteristics appeared for larger gap size and tube diameter. The heat transfer coefficients measured were also compared with the calculation results by Chens correlation.

  • PDF

A STEADY FLOW MODEL OF A MAGNETIC FLUX TUBE CONSTRAINED TO OBSERVED DIFFERENTIAL EMISSION MEASURE

  • BONG SU-CHAN;CHAE JONGCHUL;YUN HONG SIK
    • Journal of The Korean Astronomical Society
    • /
    • v.33 no.3
    • /
    • pp.159-163
    • /
    • 2000
  • We have investigated one dimensional steady flow model of a typical magnetic flux tube in the solar transition region constrained to observed Differential Emission Measure (DEM) for the average quiet-Sun deduced by Raymond & Doyle (1981) with a flux tube geometry conforming to Doppler shifts of UV lines measured by Chae, Yun & Poland (1998). Because local heating and filling factor in the transition region are not well known, we considered two extreme cases, one characterized by the filling factor= 1 ('filled-up model') and the other set by local heating=0 ('not-heated model'). We examined how much the heating is required for the flux tube by recomputing a model through adjustment of the filling factor in such a way that 'not-heated model' accounts for the observed DEM.

  • PDF