• Title/Summary/Keyword: HeatPump

Search Result 1,591, Processing Time 0.032 seconds

A Study on the Infrastructure of All-electric Houses in the Viewpoint of Hydrogen Economy (수소경제 관점의 전기에너지주택 보급기반 구축에 관한 연구)

  • Hwang, Sung-Wook;Lee, Hyeon-Ju;Kim, Kang-Sik;Nah, Hwan-Seon;Kim, Jung-Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.1
    • /
    • pp.100-109
    • /
    • 2012
  • In this paper, some ideas are proposed to establish the infrastructure of all-electric houses which are able to reduce primary energy consumption and $CO_2$ emission by adopting heat pump systems and induction heating cookers excluding the use of fossil fuel energy. This electrification concept is based on the consumption of only one type of energy which means electricity as secondary energy and the conventional fossil fuel energy is just consumed to generate electricity as primary energy. All-electric house is laid on the extension of the hydrogen economy in a long-term viewpoint so that the effectiveness of this new conceptual house is estimated analyzing the reduction of $CO_2$ emission. In this analysis, the balance of electricity supply and demand is considered including the construction of new power plants by renewable energy such as nuclear, IGCC and fuel cell because decarbonization is an essential element of hydrogen technology and economy and this action is accomplished in both supply and demand side of electricity. The results are able to contribute to develop various useful hydrogen policies and strategies and some detail researches are required previously to make the best application of this new conceptual house.

A Study on the Control of the Temperature and Relative Humidity in Greenhouse by Adjusting the Amount of Natural Ventilation and Fog Spray Quantity (자연환기량과 포그분무량 조절에 의한 온실 온습도의 동시제어 기법 연구)

  • Kim, Youngbok;Sung, Hyunsoo;Hwang, Seungjae;Kim, Hyeontae;Ryu, Chanseok
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.31-50
    • /
    • 2016
  • To develope a greenhouse fog cooling system to control the temperature and relative humidity simultaneously to the target value, a theoretical analysis and experiments were done. The control process includes the measuring of environmental variables, setting and coding of the water and heat balance equations to maintain the target temperature and relative humidity in greenhouse, calculating of the open level of the greenhouse roof window that governs the natural ventilation and spray water quantity, and operating of the motor to open/close the roof window and pump to spray for water. The study results were shown to be very good because the average air temperature in the greenhouse was kept to be about $28.2^{\circ}C$ with the standard deviation of about $0.37^{\circ}C$ compared to the target temperature of $28^{\circ}C$ and the average relative humidity was about 75.2% compared to the target relative humidity was 75% during the experiments. The average outside relative humidity was about 41.0% and the average outside temperature was $27.2^{\circ}C$ with the standard deviation of about $0.54^{\circ}C$. The average solar intensity in the greenhouse was 712.9 W. The wind velocity of outside greenhouse was 0.558 m/s with the standard deviation of 0.46 m/s.

UNCERTAINTY AND SENSITIVITY ANALYSIS OF TMI-2 ACCIDENT SCENARIO USING SIMULATION BASED TECHNIQUES

  • Rao, R. Srinivasa;Kumar, Abhay;Gupta, S.K.;Lele, H.G.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.807-816
    • /
    • 2012
  • The Three Mile Island Unit 2 (TMI-2) accident has been studied extensively, as part of both post-accident technical assessment and follow-up computer code calculations. The models used in computer codes for severe accidents have improved significantly over the years due to better understanding. It was decided to reanalyze the severe accident scenario using current state of the art codes and methodologies. This reanalysis was adopted as a part of the joint standard problem exercise for the Atomic Energy Regulatory Board (AERB) - United States Regulatory Commission (USNRC) bilateral safety meet. The accident scenario was divided into four phases for analysis viz., Phase 1 covers from the accident initiation to the shutdown of the last Reactor Coolant Pumps (RCPs) (0 to 100 min), Phase 2 covers initial fuel heat up and core degradation (100 to 174 min), Phase 3 is the period of recovery of the core water level by operating the reactor coolant pump, and the core reheat that followed (174 to 200 min) and Phase 4 covers refilling of the core by high pressure injection (200 to 300 min). The base case analysis was carried out for all four phases. The majority of the predicted parameters are in good agreement with the observed data. However, some parameters have significant deviations compared to the observed data. These discrepancies have arisen from uncertainties in boundary conditions, such as makeup flow, flow during the RCP 2B transient (Phase 3), models used in the code, the adopted nodalisation schemes, etc. In view of this, uncertainty and sensitivity analyses are carried out using simulation based techniques. The paper deals with uncertainty and sensitivity analyses carried out for the first three phases of the accident scenario.

Spot Cooling System Development for Ever-bearing Strawberry by Using Low Density Polyethylene Pipe (연질 PE관을 이용한 여름딸기 부분냉방기술 개발)

  • Moon, Jong Pil;Kang, Geum Choon;Kwon, Jin Kyung;Lee, Su Jang;Lee, Jong Nam
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.149-158
    • /
    • 2014
  • The effects of spot cooling on growing ever-bearing strawberry in hydroponic cultivation during summer by spot cooling system was estimated in plastic greenhouse located in Pyeongchang. The temperature of cooling water was controlled by heat pump and maintained at the range of $15{\sim}20^{\circ}C$. Cooling pipes were installed in root zone and very close to crown. Spot cooling effect was estimated by applying system in three cases which were cooling root zone, crown plus root zone, and crown only. White low density polyethylene pipe in nominal diameter of 16 mm was installed on crown spot, and Stainless steel flexible pipe in nominal diameter of 15A was installed in root zone. Crown and root zone cooling water circulation was continuously performed at flowrates of 300 ~ 600 L/hr all day long. Strawberry yields by test beds were surveyed from Aug. 1 to Sep. 30. The accumulated yield growth rate compared with a control bed of crown cooling bed was 25 % and that of crown plus root zone cooling bed was 25 % and that of root zone cooling bed was 20 %. The temperatures of root spot in root zone cooling was maintained at $18{\sim}23.0^{\circ}C$ and that of crown spot in crown cooling was maintained at $19{\sim}24^{\circ}C$. Also, the temperatures of root spot in crown plus root zone cooling bed was maintained at $17.0{\sim}22.0^{\circ}C$ and that of crown spot was maintained at $19{\sim}25^{\circ}C$.

Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor (오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.

A Study on the Energy Improvement Plan of using Passive Design with Exterior Envelopes and Renewable Energy for Bio Safety Labotratory (외피의 Passive Design 요소와 신재생에너지를 적용한 생물안전 밀폐시설의 에너지 시스템 개선방안 연구)

  • Hwang, Ji Hyun;Bum, Do;Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.491-496
    • /
    • 2014
  • In general, the entire air supply of a bio-safety laboratory (BSL) should be exhausted on the outside to ensure bio-safety, and the air conditioning system should always be operated to maintain a difference in the room pressure. As a result, the annual energy consumption of such a building is approximately five or ten times higher than that of an office building of the same magnitude. Thus, this study applies an actual operating system that targets BSL. The energy consumption is analyzed using the Energy Plus V8.0 program (an energy analysis program), and five kinds of cases that depend on the energy consumption of the basic BSL system are also analyzed. As a result, the energy consumption in Case 1 (basic system) is of 324.95 GJ. When the basic system of Case 1 is compared to that in Case 2 (basic system+passive design with exterior envelopes), an annual energy savings of is 6.9% is achieved. For Case 3 (basic system+Photovoltaic, PV) 12.7% is achieved, and for Case 4 (Solar Geothermal Hybrid System of renewable energy, SGHS) 49.5% is achieved. If a passive design with exterior envelopes and renewable energy system (PV+SGHS) is combined, as in Case 5, the energy consumption would be 118.15 GJ. Therefore, when this last system is compared to a basic system, the passive design with exterior envelopes and renewable energy system (PV+SGHS) can reduce energy consumption by 63.6%.

A Study on Extracting Bottom Water Taking in Concern of Temperature Level Boundaries (수온층을 고려한 저층수 취수 기술에 관한 연구)

  • Sim, Kyung-Jong;Park, Hee-Moon;Lim, Hyun-Mook;Cho, Su;Lee, Su-Yul;Park, Tae-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1285-1290
    • /
    • 2008
  • The interest in use of new field of energy and unused existing potential energy has been raised in number of advanced countries including South Korea. As a respond of the interest and the following reactions, a new technology which helps to reduce bad environmental factors and decrease national energy consumption rate in the way of extract cold-heat energy in dam water. This research focuses on a method that enables taking the water flows in desirable temperature range whilst keeping water temperature boundaries of bottom level water. The analysis was made in simulating on CFD. In order to keep the temperature boundary level, a deep well pump was set in piping in the simulation. As the significant result, the most alteration in temperature was found when the smallest size of pipe was plumbed. However, when the flow has small value of velocity, no matter how big the piping size was, the temperature variation was negligible. Therefore, possible hypothesis was made as bigger piping as fast flow will have better function in the way to keep the temperature boundary level.

  • PDF

Themodynamic Characteristics of a Two-Stage Binary Absorption Cycle (2단(段) 2원(元) 흡수(吸收)사이클의 특성(特性)에 관(關)한 연구(硏究))

  • Lee, Y.H.;Rie, D.H.;Kashiwagi, T.;Seo, J.Y.
    • Solar Energy
    • /
    • v.15 no.1
    • /
    • pp.29-38
    • /
    • 1995
  • This paper concerns the study of a two-stage binary absorption cycle employing the refrigerant/absorbent combinations of $LiBr/H_2O$ and $NH_3/H_2O$. This cycle consists of coupling two single-effect absorption cycles so that the first stage absorber and condenser produces heating water to evaporate refrigerant in the evaporator of the second stage. The effect of operating variables such as evaporator temperature, condenser and absorber temperature, and generator temperature on the coefficient of performance and temperature lift have been studied for two-stage binary absorption heat pump systems. It is found that this cycle has a large temperature lift at $105^{\circ}C$ of optimum generator temperature to obtain $50^{\circ}C$ of condenser temperature.

  • PDF

A Study of Closed OTEC Power Plants (폐쇄형 해양온도차발전 사이클에 관한 연구)

  • Shin, Sang-Ho;Jung, Dong-Soo;Kim, Chong-Bo;Seo, Tae-Beom;Chun, Won-Gee;Auh, P. Chung-Moo
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.23-33
    • /
    • 1997
  • In this paper, performance of various working fluids is evaluated for the closed Ocean Thermal Energy Conversion(OTEC) power plant operating on Rankine cycle. The evaporator and condenser are modeled via UA and LMTD method while turbine and pump are modeled by specifying isentropic efficiencies. R22, Propane, Propylene, R134a, R125, R143a, R32, R410A and Ammonia are used as working fluids. Results show that newly developed fluids such as R410A and R32 that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. The superheat at the evaporator exit and subcooling at the condenser exit do not affect the performance of the simple OTEC power cycle. Turbine efficiency and heat exchanger size influence greatly the performance of the Rankine cycle. Finally, it was shown that closed OTEC power plants can practically generate electricity when the difference in warm and cold sea water inlet temperatures is greater than $20^{\circ}C$.

  • PDF

Performance Analysis of a $CO_2$ Two-Stage Twin Rotary Compressor ($CO_2$ 2단 트윈 로타리 압축기 성능해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • Analytical investigation on the performance of a two stage twin rotary compressor for $CO_2$ heat pump water heater system has been carried out. A computer simulation program was made based on analytical models for gas compression in control volumes, leakages among neighboring volumes, and dynamics of moving elements of the compressor. Calculated cooling capacity, compressor input, and COP were well compared to those of experiments over the compressor speeds tested. For the operating condition of suction pressure of 3 MPa, and discharge pressure of 9 MPa, and compressor inlet temperature of $35^{\circ}C$, the compressor efficiency was calculated to be 80.2%: volumetric, adiabatic, and mechanical efficiencies were 88.3%, 93.2%, and 92.7%, respectively. For the present compressor model, volumetric and adiabatic efficiencies of the second stage cylinder were lower by about $6{\sim}7%$ than those of the first stage mainly due to the smaller discharge port at the second stage. Parametric study on the discharge port size showed that the compressor performance could be improved by 3.5% just by increasing the discharge port diameter by 20%.