• 제목/요약/키워드: Heat-wave

검색결과 738건 처리시간 0.021초

열유속 상지연이 존재하는 열전도 현상에 대한 연구 (A Study of the Heat Conduction Phenomena with a Phase Lag of Heat Flux)

  • 김창복;김경근;정한식;정효민;최두열;최순호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.684-690
    • /
    • 2008
  • In most engineering applications related with the heat conduction phenomena, a conventional Fourier heat conduction equation has been successfully applied and it has supplied quite reasonable results. However, it is well known that the Fourier heat conduction equation is failed in the application to the extremely small space and short time, in other words, a nano-scale system and a pico-second time. In this study, non-Fourier effect was evaluated in the heat conduction by considering the concept of a phase lag model. The results show the existence of a heat wave, which means that the heat is transferred with a finite speed while an infinite speed of heat transfer is assumed in the conventional Fourier heat conduction. In addition, the copper and the gold are tested to evaluate the phase lag time between the heat flux and the temperature gradient. The results show that the gold has the heat wave speed faster than that of the copper consistent with the prediction based on an actual experiment.

촌관척(寸關尺)부의 검측한 부정맥과 Electrocardiographic 결과의 한의학적 검토 (The Oriental Medical Study about the Arrythmia Detected on the Radial Pulses and the Result of ECG.)

  • 류희영;허은정;김지현;윤정미;전성하
    • 동의신경정신과학회지
    • /
    • 제19권2호
    • /
    • pp.165-193
    • /
    • 2008
  • Objective: The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒)type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. Method & Conclusion: 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using ECG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the ECG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血) had downward aptitude of QRS wave, the wave which had both Cold(寒)) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈)is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). Result : From these results, we will have to study about ECG which using in tests of change of Parkinsons disease.

  • PDF

Resistive Grounding Technique of Heat Sink for Reducing Radiation Noise

  • Ahn, Chang-Hoi;Oh, JaeHyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1724-1728
    • /
    • 2014
  • Heat sink has been used to help an electrical device operate in normal temperature condition. But heat sink radiates unwanted electromagnetic wave, which may cause electromagnetic interference problem. A resistance loaded grounding technique is proposed to reduce electromagnetic wave radiation by a heat sink. Numerical simulations are accomplished to find optimal loading resistance. Also electromagnetic fields radiated by from a heat sink are measured and compared with the simulation results. The test results verify the usefulness of the proposed technique.

Airside Performance of Convex Louver Fin-and-Tube Heat Exchangers

  • Kim, Nae-Hyun;Oh, Wang-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권3호
    • /
    • pp.100-107
    • /
    • 2008
  • The heat transfer and friction characteristics of heat exchangers having convex louver fins are experimentally investigated, and the results are compared with those of wave fin counterparts. Eighteen samples (nine convex louver fin samples and nine wave fin samples) which had different fm pitches (1.81 mm to 2.54 mm) and tube rows (one to four) were tested. The convex angle was $11.7^{\circ}$. The j factors are insensitive to fin pitch, while f factors increase as fin pitch increases. The effect of fin pitch on f factor is more significant for the wave fin compared with the convex louver fin. It appears that the complex fin pattern of the convex louver fin induces intense mixing of the flow, and thus reduces the effect of fin pitch. Both the j and f factors decrease as the number of tube row increases. However, as the Reynolds number increases, the effect of tube row diminishes. Comparison of the convex louver fin j factors with those of wave fin reveals that convex louver fin j factors are 18% to 29% higher than those of wave fin. The f factors are 16% to 34% higher for the convex louver fin. The difference increases as fin pitch decreases. Existing correlation fails to adequately predict the present data. More data is needed for a general correlation of the convex louver fin geometry.

국내 폭염 저감 시설의 온열 만족도에 대한 연구 (A Study on Thermal Satisfaction of Domestic Heat Wave Reduction Facilities)

  • 전용준;박률;박경순
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권1호
    • /
    • pp.1-11
    • /
    • 2022
  • As abnormal climates occur due to the increase in greenhouse gases at home and abroad, various problems such as human casualties, crop damage, energy depletion, and economic loss due to heat diseases, which are one of the extreme climate phenomena, are following one after another. In response, the government has established the 'Climate Crisis Response Special Committee' since 2018, when it recorded the greatest damage in history due to heat waves, and has been carrying out budget formation and reform of laws and systems every year to respond to heat waves. However, in relation to the heat wave damage reduction facility that is being expanded with a large budget, there is no prior research related to the degree of heat loss due to the use of the facility, the difference in effects between specific groups, and the economic effect that comes back compared to the invested budget. Therefore, from a midto long-term perspective, it is expected that it will be difficult to establish a clear direction for policy making. Therefore, in this study, representative facilities were selected according to the principle of heat reduction among the currently expanded heat damage reduction facilities, and a questionnaire survey was conducted for users of each reduction facility (waterfall, awning, pond, and elastic pavement). Accordingly, the change in the sense of heat according to the use of the heat damage reduction facility was checked, and the change in the sense of heat according to the group characteristics (gender, age, metabolic rate) was analyzed to examine the characteristics of the relationship between the facility and the users.

Association Between Air Conditioning Use and Self-reported Symptoms During the 2018 Heat Wave in Korea

  • Lee, Yong-Han;Bae, Sanghyuk;Hwang, Seung-sik;Kim, Jong-Hun;Kim, Kyoung-Nam;Lim, Youn-Hee;Kim, Miji;Jung, Sohwa;Kwon, Ho-Jang
    • Journal of Preventive Medicine and Public Health
    • /
    • 제53권1호
    • /
    • pp.15-25
    • /
    • 2020
  • Objectives: The purpose of this study was to investigate the health effects of air conditioning use during the 2018 heat wave in Korea, included the highest temperature ever recorded in the nation. Methods: The participants in this study were 1000 adults aged 19 years and older recruited from across Korea. The participants were asked about their experience of symptoms of various diseases, disruptions of their daily lives, and use of air conditioning during the heat wave. The associations between air conditioning use during the heat wave and health outcomes were analyzed using the chisquare test and multiple logistic regression models. Results: Among participants who lacked air conditioning in the main space where they spent time outside the home, 33.9%, 8.1%, 43.5%, and 19.4% experienced symptoms of heat-related, cardiovascular, nervous system diseases, and air-conditioningitis, respectively. In comparison, participants who did have air conditioning outside the home experienced the same symptoms at proportions of 21.0%, 1.9%, 26.8%, and 34.2%, respectively (p=0.027, 0.007, 0.007, and 0.023, respectively). Among participants who had no air conditioner at home, 10.0% were absent from school or work due to the heat wave. In contrast, among participants who had an air conditioner at home, only 3.7% were absent as a result of the heat wave (p=0.007). Conclusions: When air conditioning was not used at home or in the main space where participants spent time outside the home during the 2018 heat wave, adverse health effects were more prevalent, but the risk of air-conditioningitis was reduced.

베타인이 폭염 오리의 짧은 사슬지방산 및 혈액 프로파일에 미치는 효과 (Effect of dietary betaine on short chain fatty acid and blood profile in meat duck exposed to extreme heat stress)

  • 황보종;방한태;박병성
    • 한국응용과학기술학회지
    • /
    • 제32권3호
    • /
    • pp.394-404
    • /
    • 2015
  • This study investigated the pharmacodynamics of betaine on the blood profile and short chain fatty acid levels in meat ducks exposed to heat wave. 400 heads of Cherry valley (Anasplatyrhynchos) meat ducks were completely randomized to 5 treatments (4 repetitions each), and were raised for 42 days. They were grouped into T1 (heat wave control group without betaine), T2 (betaine 400 ppm), T3 (betaine 800 ppm), T4 (betaine 1200 ppm), and T5 (normal control group without betaine). Compared to T1, the betaine addition groups showed higher body weight gain at shipment, with T3 showing the highest significant difference. For hematological indictors measured (red blood cells and platelets), the betaine addition groups showed significantly higher values than the heat wave control group. The pH of the former was lower but their electrolytes ($K^+$, $P^+$, and $Cl^-$) were significantly higher compared to the latter. For blood gas concentration, the former showed a significantly higher value than the latter. For the total short chain fatty acids, acetic acid, and propionic acid, the betaine addition groups and group fed broiler-high temperature diet showed higher values than the heat wave control group. On the other hand, the former showed significantly lower values in butyric acid, isobutyric acid, valeric acid, and isovaleric acid than the latter group. These results suggest that betaine has the pharmacodynamics that mediate heat stress, via the maintenance and control of the blood profile, osmotic pressure, gas concentration, and short chain fatty acid, of meat ducks under heat wave.

대구의 2016년 폭염시기 열 스트레스 지표의 비교 (Comparison of Several Heat Stress Indices for the 2016 Heat Wave in Daegu)

  • 김지혜;김해동
    • 한국환경과학회지
    • /
    • 제26권12호
    • /
    • pp.1399-1405
    • /
    • 2017
  • We compared the spatial distribution of several heat stress indices (the Wet-Bulb Globe Temperature(WBGT) index, Environmental Stress Index (ESI), and Modified Discomfort Index(MDI)) for the heat wave of June 6~August 26, 2016, in Daegu. We calculated the heat stress indices using data from the high density urban climate observation network in Daegu. The observation system was established in February. 2013. We used data from a total of 38 air temperature observation points (23 thermometers and 18 automatic weather stations). The values of the heat stress indices indicated that the danger level was very high from 0900-2000h in downtown Daegu. The daily maximum value of the WBGT was greater than or equal to $35^{\circ}C$. The differences in the heat stress indices from downtown and rural areas were higher in the daytime than at nighttime. The maximum difference was about 4 before and after 1400h, and the time variations of the heat stress indices corresponded well. Thus, we were able to confirm that the ESI and MDI can be substituted with the WBGT index.

다양한 형상의 판형 휜을 장착한 원통다관형 열교환기의 열성능 해석 (Thermal Performance Analysis of a Shell-and-Tube Heat Exchanger with Plate Fins of Various Shape)

  • 신지영;손영석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.648-656
    • /
    • 2004
  • In this study, a highly efficient shell-and-tube heat exchanger with plate fins is considered to improve thermal performance of the conventional shell-and-tube heat exchanger. This type of shell-and-tube heat exchanger with plate fins of various shape is simulated three-dimensionally using a commercial thermal-fluid analysis code. CFX4.4. The effect of the shape of the plate fin on heat transfer characteristics is also investigated by the simulation. Plate fins of four different shapes. plane, plane-slit. wave. and wave-slit fins, are considered. The flow fields, pressure drop and heat transfer characteristics in the heat exchanger are calculated. It is proved that the shell-and-tube heat exchanger with plate fins is superior to the conventional shell-and-tube heat exchanger without plate fins in terms of heat transfer. The shape of the plate fin is important in the performance of a heat exchanger such as heat transfer and pressure drop.

Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

  • Tatiana Dias Costa;Elison da Fonseca e Silva;Paula Liparini Caetano ;Marcio Jose da Silva Campos ;Leandro Marques Resende ;Andre Guimaraes Machado;Antonio Marcio Resende do, Carmo
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.6.1-6.10
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickel-titanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (Ecorr). The pitting potential (Epit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for Ecorr) and the Student t-test for independent samples (for Epit). Results: The mean Ecorr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with Epit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.