U형 히트파이프의 작동 특성에 관한 연구 (A Study on the Operational Characteristics of a U-shape Heat Pipe)

  • 강환국;김철주;이용수
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1711-1720
    • /
    • 2001
  • In this study, the heat transfer characteristics of a U-shape heat pipes were investigated. Heat is supplied to the U heat pipe through its middle zone(evaporator), and is released to the environment through its both arms(condensers). Both heat transfer coefficients and heat transport limitations were measured and compared with correlations previously developed for straight type heat pipes. Special concerns were focused to the cases, when each of condensers were submitted to a different cooling conditions, relatively. As a result. the heat transfer limitation of a U-shape heat pipe was found out to be 10∼15% less than the value for a straight heat pipe with an equivalent size.

창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가 (Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea)

  • 임희원;김동윤;이수만;안정혁;윤종호;신우철
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.159-166
    • /
    • 2018
  • The Korean fenestration energy consumption efficiency rating system only considers thermal performance of the heat transfer coefficient (U-value) and airtightness excluding optical characteristics of the solar heat gain coefficient (SHGC). This study analyzed annual heating and cooling energy requirements on the middle floor of apartment by optical and thermal performance of windows to evaluate the suitability of the rating system. One hundred and twenty-eight windows were analyzed using THERM and WINDOW 7.4, and energy simulation for a reference model of an apartment house facing south was performed using TRNSYS 17. The results showed that window performance was the main factor in the heating and cooling load. The heating load of the reference model was 539 kWh to 2,022 kW, and the cooling load was 376 kWh to 1,443 kWh. The coefficient of determination ($R^2$) of the heating and cooling loads driven from the SHGC were 0.7437 and 0.9869, which are more compatible than those from the U-value, 0.0558 and 0.4781. Therefore, it is not reasonable to evaluate the energy performance of windows using only the U-value, and the Korean fenestration energy consumption efficiency rating system requires a new evaluation standard, including SHGC.

삼상 Swirling 유동층에서 열전달 특성 (Characteristics of Heat Transfer in Three-Phase Swirling Fluidized Beds)

  • 손성모;신익상;강용;조용준;양희철
    • Korean Chemical Engineering Research
    • /
    • 제46권1호
    • /
    • pp.56-62
    • /
    • 2008
  • 직경이 0.102 m이고 높이가 2.5 m인 삼상 swirling(나선) 흐름 유동층에서 열전달 특성을 고찰하였다. 기체유속($U_G$), 액체유속($U_L$), 유동 입자의 크기($d_p$), 그리고 연속상인 액체의 나선 유도 흐름 액체량의 비($R_S$)가 유동층 내부 열원과 유동층간의 총괄 열전달 계수에 미치는 영향을 검토하였다. 유동층 내부 열원과 유동층간의 열전달 특성은 열원 표면과 유동층간의 온도차 요동 자료의 위상공간 투영과 Kolmogorov 엔트로피 해석으로 고찰할 수 있었으며, 나선 유도 흐름 액체량의 비($R_S$)가 0.1에서 0.4까지 증가할수록 온도차 요동 자료의 위상 공간 투영은 점점 안정되고 규칙성이 증대되는 상태를 나타내고, Kolmogorov 엔트로피 값은 감소하는 경향을 나타내었다. 열원 표면과 유동층간의 온도차 요동 자료의 Kolmogorov 엔트로피 값은 나선 유도 흐름 액체량이 증가함에 따라 최소값을 나타내었다. 열원과 유동층간의 총괄 열전달 계수는 기체 유속 및 유도입자의 크기가 증가함에 따라서 증가하였으나, 액체유속, 층공극률, 나선 유도 흐름 액체량의 비가 증가함에 따라서 최대값을 나타내었다. 내부 열원과 유동층간의 총괄 열전달 계수가 최대값을 나타낼 때의 액체의 유속 조건에서 온도차 요동자료의 Kolmogorov 엔트로피의 값도 최대값을 나타내었다. 삼상 나선흐름 유동층에서 열전달 계수와 Kolmogorov 엔트로피를 실험 변수 및 무차원군의 상관식으로 나타낼 수 있었다.

삼상슬러리 기포탑에서 액상의 표면장력이 열전달 계수에 미치는 영향 (Effects of Liquid Surface Tension on the Heat Transfer Coefficient in a Three-Phase Slurry Bubble Column)

  • 임호;임대호;진해룡;강용;정헌
    • Korean Chemical Engineering Research
    • /
    • 제50권3호
    • /
    • pp.499-504
    • /
    • 2012
  • 산업현장에서 자주 접하는 액상의 물성인 표면장력이 상대적으로 작은 액상으로 구성된 삼상슬러리 기포탑에서 총괄 열전달 특성을 고찰하였다. 기포탑 내부의 열전달 현상은 기포탑 내부의 수직 열원과 기포탑 간의 열전달계를 구성하여 고찰하였으며 열전달 계수는 정상상태에서 열원표면의 온도와 기포탑 내부의 평균 온도의 차를 측정하여 결정하였다. 기체유속($U_G$), 슬러리 상에 포함된 고체입자의 분율($C_S$) 그리고 연속 액상의 표면장력(${\sigma}_L$)이 기포탑 내부의 총괄 열전달 계수(h)에 미치는 영향을 규명하였다. 기포탑 내부 열원 표면과 기포탑 벌크영역 간의 온도차는 시간의 변화에 따른 온도차 요동을 측정하여 그 평균값으로 결정하였다. 기포탑 내부 열원표면과 기포탑 벌크 영역 간의 온도차 요동은 연속 액상의 표면장력이 감소할수록 진폭이 감소하였으며 온도차의 평균값도 감소하였다. 내부 수직 열원과 기포탑 간의 총괄 열전달 계수는 기체의 유속과 슬러리 상에 포함된 고체입자의 분율이 증가함에 따라 증가하였으며 연속 액상의 표면장력이 증가함에 따라 감소하였다. 표면장력이 물보다 작은 연속 액상의 기포탑에서 측정된 총괄 열전달 계수는 본 연구의 범위 내에서 실험변수와 무차원군의 상관식으로 나타낼 수 있었다.

스파크 점화기관의 순간열전달계수의 경험식 결정 (Determination of empirical formula for instantaneous heat transfer coefficients in a S. I. engine)

  • 한성빈;권영직;이성렬
    • 대한기계학회논문집B
    • /
    • 제21권11호
    • /
    • pp.1475-1484
    • /
    • 1997
  • A new empirical formula for instantaneous heat transfer coefficients was determined. The determination of this formula is in need for prediction of instantaneous value of heat transfer coefficients to analyze in more detail the time variation of heat transfer rate from gas to wall in combustion chamber of a spark ignition engine. As the result, following formula was determined. h=687 $p^{0.75}$ $U^{0.75}$ $D^{0.25}$ - $T^{-0.465}$ U(.theta.)=O.494 $V_{p}$ +0.73*10$^{6}$ (1.35 p dV/d.theta.+V dp/d.theta.) Using this empirical formula, the instantaneous heat transfer coefficients of gas in the combustion chamber of spark ignition engine was predicted and compared with experimental values.

The method of in-situ ASTR method diagnosing wall U-value in existing deteriorated houses - Analysis of influence of internal surface total heat transfer rate -

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jeong, Hakgeun;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.41-48
    • /
    • 2017
  • Purpose : Currently, 25% of the domestic energy consumption structure is used as building energy, and more than 18% of this energy is consumed in the residential. Accordingly, various efforts and policies that can save energy of the building is being performed. The various researchers are conducting research to diagnose the thermal performance of existing buildings. This study is to apply in the field of precision thermal insulation performance diagnostic method for thermal performance analysis of existing detached house in Seoul, Gangreung, Gyeongju, Pohang. And this paper is analyzed quantitatively measure the existing detached house energy performance. Method: Research methodology analyzed the thermal performance over the Heat Flow Meter method by applying the measurement process and method by applying the criteria of ISO 9869-1 & ASTR method. In this study, the surface heat transfer coefficient was calibrated by applying indoor surface heat transfer resistance with reference to ISO 6946 standard. The measurement error rate between the HFM diagnosis method and the ASTR diagnosis method was reduced and the measurement reliability was obtained through measurement method error verification. Result : As a result of the study, the thermal performance vulnerable parts of the building were quantitatively analyzed, and presented for methods which can be improved capable of efficient energy use buildings.

창호에 SHGC를 반영한 공동주택의 방위각별 에너지 효율성 평가를 통한 합리적인 창호 계획 방안 연구 (A Study on the optimized Performance Designing of the Window of the Apartment based on the Annual Energy Demand Analysis according to the Azimuth Angle applying the Solar Heat Gain Coefficient of the Window)

  • 이장범
    • 대한건축학회논문집:계획계
    • /
    • 제35권11호
    • /
    • pp.25-34
    • /
    • 2019
  • It is important to design windows in a reasonable way considering the performance characteristics of the elements of the window rather than just to increase the thermal energy performance of the window. In this study, the Heat-transfer Coefficient as insulation performance of the windows and together with the grade of the glass's SHGC (Solar Heat Gain Coefficient) were analyzed to relate to the energy efficiency performance of the building by azimuth angle. Based on this basic study, the Heat-transfer Coefficient of windows and the SHGC rating of glass were applied to the unit plan of apartment building, and the Heating and Cooling Demand were analyzed by azimuth angle. Apartment plan types were divided into 2 types of Non-extension and extension of balcony. The designPH analysis data derived from the variant of the Heat-transfer Coefficient and SHGC, were put into PHPP(Passive House Planning Package) to analyze precisely the energy efficiency(Heating and Cooling Demands) of the building by azimuth angle. In addition, assuming the 'ㅁ' shape layout, energy efficiency performance and potential of PV Panel installation also were analyzed by floors and azimuth angle, reflecting the shading effects by surrounding buildings. As the results of the study, the effect of Heat Gain by SHGC was greater than Heat Loss due to the Heat-transfer Coefficient. So it is more effective to increase SHGC to satisfy the same Heating Demand, and increasing SHGC made possible to design windows with low Heat-transfer Coefficient. It was also revealed that the difference in annual Heating and Cooling Demands between the low, mid and high floor households is significantly high. In addition to it, the installation of PV Panel in the form of a shading canopy over the window reduces the Cooling Load while at the same time producing electricity, and also confirmed that absolute thermal energy efficiency could not be maximized without controlling the thermal bridge and ventilation problems as important heat loss factors.

온실용 이중피복 및 보온재의 관류열전달계수 산정을 위한 수치적 연구 (A Numerical Study for Calculation of Overall Heat Transfer Coefficient of Double Layers Covering and Insulation Material for Greenhouse)

  • 이종원;김동건;이현우
    • Current Research on Agriculture and Life Sciences
    • /
    • 제33권2호
    • /
    • pp.41-47
    • /
    • 2015
  • 본 연구는 온실용 피복재 및 보온재의 조합에 대한 시뮬레이션 해석모델을 개발하여 관류열전달계수를 산정하고 측정된 결과와 비교하여 타당성을 평가하기 위해 수행되었으며 결과를 요약하면 다음과 같다. 유리이중피복의 경우 이중피복 사이의 공기층이 두꺼워짐에 따라 관류열전달계수가 서서히 작아져서 공기층 두께가 25 mm 이상이 되면 관류열전달계수의 변화가 거의 없는 것을 확인할 수 있었다. 또한 온도차가 증가함에 따라 관류열전달계수도 증가하는 것을 확인할 수 있었다. 두 플라스틱 피복재 사이에는 대류에 의한 열전달이 활발하게 일어나기 때문에 비정상 유동에 의한 열전달이 발생하고 이로 인해 온도분포도 비선형적으로 변하는 것으로 사료된다. 플라스틱 피복재 및 보온재들의 간격이 50~200 mm범위에서 변화할 때에 피복재의 간격은 관류열전달계수 큰 영향을 미치지 않는다는 사실을 확인할 수 있었다. 천공복사를 고려한 경우와 고려하지 않은 경우 모두 핫박스의 내외부 온도차가 $30^{\circ}C$인 조건에 대해서는 수치해석결과와 실험결과가 대체로 잘 일치하였다. 따라서 핫박스의 내외부 온도차가 $30^{\circ}C$ 이상인 조건에서 수치해석을 통해 관류열전달계수를 산정한다면 신뢰성 있는 값을 얻을 수 있을 것으로 판단된다.

BES를 이용한 온실용 보온커튼의 관류열전달계수 산정 (Evaluation of Overall Heat Transfer Coefficient of Different Greenhouse Thermal Screens Using Building Energy Simulation)

  • 라쉬드아드난;이종원;이현우
    • 생물환경조절학회지
    • /
    • 제27권4호
    • /
    • pp.294-301
    • /
    • 2018
  • 겨울철에 열손실을 줄이기 위해 많은 온실에서 보온커튼을 사용하고 있다. 그러나 적절한 보온커튼을 선택할 때 판단 자료로 활용할 수 있는 명확한 기준이 없는 실정이며 이를 위해서는 보온재의 보온 특성에 대한 정량적인 값이 필요하다. 본 연구에서는 BES를 사용하여 보온커튼의 관류열전달계수를 산정하는 시뮬레이션 모델을 개발하였다. 일중 및 이중 PE필름 피복에 대한 관류열전달계수의 실험값을 사용하여 시뮬레이션 결과를 검증하였다. 검증된 모델을 사용하여 문헌에서 제시된 각종 열적 특성을 가진 보온커튼에 대한 관류열전달계수를 산정하고 비교분석하였다. 개발된 시뮬레이션 모델은 다양한 보온커튼의 관류열전달계수를 산정하는 데 활용될 수 있을 것이며, 제시된 관류열전달계수는 보온커튼의 성능을 정량적으로 비교하는데 유용하게 활용될 수 있을 것으로 판단된다.

표면방사율에 따른 복사단열시스템의 열관류성능 평가 연구 (Evaluation of U-value for Radiant Barrier Systems in Relation to Surface Emissivity)

  • 김기세;이동규;윤종호;송인춘
    • 태양에너지
    • /
    • 제20권3호
    • /
    • pp.39-50
    • /
    • 2000
  • Radiant barrier systems(RES) constructed with low emissivity materials bounded by an open air space can be used to reduce the net radiation transfer between two surfaces. To analyze the heat transfer characteristics of the radiant barrier systems which consist of a single-glass and radiation barriers, a simple theoretical model based on energy balances was suggested. And the model was validated by means of the experimental results. Using a guarded hot box, the temperatures of layers in selected RES and energy use for each cases were measured. The results show that the model well explained the heat transfer characteristics of those RES. Also, the heat transfer coefficient correlations considering natural and forced convection heat transfer ware suggested. It is found that the heat transfer efficiency of a RBS with aluminium surface improved up to 66.6% over that of a single glazing system.