• Title/Summary/Keyword: Heat-load test

Search Result 364, Processing Time 0.03 seconds

A Study on the Operating Control of a 2-Stage Heat Pump System with Screw Compressors (스크류 2단 압축 열펌프 시스템의 운전 제어 방안에 관한 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Lee, Young-Soo;Ra, Ho-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.501-505
    • /
    • 2006
  • A preliminary performance test of a 30RT 2-stage screw heat pump was carried out in order to develop a high performance large-scale unutilized energy source heat pump, which will be used in district heating and cooling. Two issues on the system control were investigated in this study, A stable 2-stage heating operation is guaranteed only if the load-side water inlet temperature is over a certain value, to where the 1-stage heating operation should be done first from a cold start. An oil shortage problem in low stage compressor, which depends on the degree of suction superheat, was solved by the proper oil level control scheme.

  • PDF

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.227-227
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler(G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 80K를 Heat Load 기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.118-118
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M 냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler (G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K와 1st STG Temp. 80K를 Heat Load기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF

Physical Properties of Cement Boards Mixed Pearlite and Expanded Graphite (펄라이트와 팽창흑연을 혼입한 시멘트 보드의 물리적 특성)

  • Lee, Ju-Won;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.65-66
    • /
    • 2023
  • Recently, the importance of improving air quality has been greatly highlighted due to environmental problems such as indoor air pollution, and efforts are being made to improve indoor air quality not only in Korea but also around the world. In this situation, this study aims to study the physical properties of cement boards using pearlite with excellent physical adsorption performance due to micropores in materials, expanded graphite that is widely used as a flame retardant to prevent heat transfer in the event of a fire. The experimental items are bending fracture load and impact resistance. The bending destruction load at the fiber mixing rates 1, 2, 3, and 4 (%) did not meet the standard 140N, but the bending destruction load at 5% was 168.2N, and the impact resistance of the fiber mixing rates 1 and 2 (%) could not be measured due to cracks and damage, and the impact resistance at 3, 4, and 5 (%).

  • PDF

A Study on Thermal Ratcheting Structure Test of 316L Test Cylinder (316L 시험원통의 열라체팅 구조시험에 관한 연구)

  • Lee, H.Y.;Kim, J.B.;Koo, G.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.243-249
    • /
    • 2001
  • In this study, the progressive inelastic deformation, so called, thermal ratchet phenomenon which can occur in high temperature liquid metal reactor was simulated with thermal ratchet structural test facility and 316L stainless steel test cylinder. The inelastic deformation of the reactor baffle cylinder can occur due to the moving temperature distribution along the axial direction as the hot free surface moves up and down under the cyclic heat-up and cool-down of reactor operations. The ratchet deformations were measured with the laser displacement sensor and LVDTs after cooling the structural specimen which experiences thermal load up to $550^{\circ}$ and the temperature differences of about $500^{\circ}C$. During structural thermal ratchet test, the temperature distribution of the test cylinder along the axial direction was measured from 28 channels of thermocouples and the temperatures were used for the ratchet analysis. The thermal ratchet deformation analysis was performed with the NONSTA code whose constitutive model is nonlinear combined kinematic and isotropic hardening model and the test results were compared with those of the analysis. Thermal ratchet test was carried out with respect to 9 cycles of thermal loading and the maximum residual displacements were measured to be 1.8mm. It was shown that thermal ratchet load can cause a progressive deformation to the reactor structure. The analysis results with the combined hardening model were in reasonable agreement with those of the tests.

  • PDF

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards (KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.63-72
    • /
    • 2017
  • This study fabricated a low-voltage 10 circuit distribution board based on the KEMC (Korea Electrical Manufacturers Cooperative) 2102-610 standard and performed a characteristics assessment of the developed 10 circuit distribution board to secure product stability. The developed 10 circuit distribution board is designed to have the characteristics of insulation materials, as well as resistance to corrosion ultraviolet radiation and mechanical impact. The developed distribution board is fabricated to have an appropriate protection class of enclosure, electric shock prevention and protection circuits, switchgear and its components, internal electrical circuits and connectors, external conduct terminal, insulation characteristics, temperature rise test, heat resistance, etc. The developed 10 circuit distribution board consists of a single phase circuit and 3-phase circuits. It is possible to measure in real time the leakage current generated from the load distribution line by installing a sensor module at the load side of each of the branched switchgears. In addition, it is possible to increase a circuit according to the use and purpose of the load and to also manage and check the load in real time. Temperature rise tests were performed on the developed 10 circuit distribution board at 18 places including the inlet connection, main circuit and distribution circuit bus bars and bus bar supports, etc. The highest temperature of $65.3^{\circ}C$ was measured at the R-Phase of the connection of the MCCB power supply for the branch circuit bus bar and a temperature rise of $61.6^{\circ}C$ was measured at the T-Phase of the load side. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state.

AZ3l Mg alloy Texture and Bending Characteristics (AZ31Mg 합금의 집합조직과 벤딩 특성)

  • Kim, In-Soo;Akramov, S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.75-76
    • /
    • 2008
  • In this study, texture development and bending characteristics of strong {0002} textured were observed. AZ31 Mg alloy sheets were prepared along the angle of 0 and 12.5 degrees to the lolling direction or {0002} texture. Prepared samples with different angles to the rolling direction were rolled at room temperature condition and after subsequent heat treatment to investigate texture with x-ray diffractometer, respectively The specimen having along the angles of 0 degree to rolling direction shows the highest load and 12.5 degrees specimen shows the highest displacement among any other specimens in bending test.

  • PDF

Welding Properties of 1000MPa Class High Strength Steel Sheets for Car Body Using Disk Laser (자동차용 1000MPa급 고장력 강판의 Disk 레이저용접 특성)

  • Seol, Hyun-Uk;Song, Mun-Jong;Lee, Kyu-Hyun;Lee, Mun-Yong;Kim, Sok-Won
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.5
    • /
    • pp.8-12
    • /
    • 2012
  • Application for laser welding have increased steadily in recent years due to its benefits such as high speed, high productivity and high density energy heat source. In this study, the influence of welding parameters was investigated on penetration characteristics, mechanical properties including formability test in disk laser welded 1000MPa class steels. A shielding gas was used and bead-on-plate test was performed with various welding speeds. The main welding test was performed by butt welding with various welding speeds at 2.5 kW laser power.

Development of a Real-Time Steady State Detector of a Heat Pump System to Develop Fault Detection and Diagnosis System (열펌프의 고장진단시스템 구축을 위한 정상상태 진단기 개발)

  • Kim, Min-Sung;Yoon, Seok-Ho;Kim, Min-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2070-2075
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF