• Title/Summary/Keyword: Heat-island

Search Result 491, Processing Time 0.03 seconds

On the Persistence of Warm Eddies in the East Sea (동해 난수성 에디의 장기간 지속에 관하여)

  • JIN, HYUNKEUN;PARK, YOUNG-GYU;PAK, GYUNDO;KIM, YOUNG HO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.2
    • /
    • pp.318-331
    • /
    • 2019
  • In this study, comparative analysis is performed on the long-term persisted warm eddies that were generated in 2003 (WE03) and in 2014 (WE14) over the East Sea using the HYCOM reanalysis data. The overshooting of the East Korea Warm Current (EKWC) was appeared during the formation period of those warm eddies. The warm eddies were produced in the shallow Korea Plateau region through the interaction of the EKWC and the sub-polar front. In the interior of the both warm eddies, a homogeneous water mass of about $13^{\circ}C$ and 34.1 psu were generated over the upper 150 m depth by the winter mixing. In 2004, the next year of the generation of the WE03, the amount of the inflow through the western channel of the Korea Strait was larger, while the inflow was lesser than its climatology during 2015 corresponding to the development period of the WE14. The above results suggest that the heat and salt are supplied in the warm eddies through the Tsushima Warm Current (TWC), however the amount of the inflow through the Korea Strait has negligible impact on the long-term persistency of the warm eddies. Both of the warm eddies were maintained more than 18 months near Ulleung island, while they have no common feature on the pathways. In the vicinity of the Ulleung basin, large and small eddies are continuously created due to the meandering of the EKWC. The long-term persisted warm eddies in the Ulleung Island seem to be the results of the interaction between the pre-existed eddies located south of the sub-polar front and fresh eddies induced by the meanderings of the EKWC. The conclusion is also in line with the fact that the long-term persisted warm eddies were not always created when the overshooting of the EKWC was appeared.

Comparison of ASTER Satellite and Ground-Based Surface Temperature Measurements for Urban Heat Island Studies (도시열섬연구를 위한 ASTER 위성영상과 지표면의 표면온도 비교)

  • Song, Bong-Geun;Park, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.3
    • /
    • pp.104-124
    • /
    • 2017
  • This study aimed to validate the ASTER surface temperature using field measurements over various land use types in the urban area of Changwon City, South Korea. The ASTER surface temperature was measured by collecting eight images during daytime and nighttime in June and September from 2012 to 2014, and field measurements were conducted over the same period when the satellite images were taken. The analyses showed that the surface temperature measured in the field during the daytime was higher than that of satellite imageries by $5{\sim}10^{\circ}C$, and the gap was higher in built-up areas. The calibration models of surface temperature showed a 60% explanatory power in areas other than parks, indicating that the models are reliable. During nighttime, except for the summer month of August, ASTER surface temperature was determined to be approximately $2^{\circ}C$ higher in contrast to daytime.

Metallurgical Study of Bronze Relics Excavated from Sanoesa Temple, Chongju (청주(淸州) 사뇌사지(思惱寺址) 출토 청동유물의 금속학적 조사)

  • Kwon, H.N.;Yu, H.S.;Ahn, B.C.
    • Journal of Conservation Science
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • In 1993, many bronze artifacts were excavated from the Sanoesa Temple(思惱寺), Chongju, Chungbuk. Twelve items were selected and chemically analyzed with AA Spectrometry and ICP-Atomic Emission Spectrometry. They were also observed under the optical microscopy and SEM. According to the results from chemical analysis, production method and use, these artifacts were classified into four groups: casting, wrought and welding products, and bells. Cast products, probably used for ritual, were alloy of 70% Cu, 10% Sn and 20% Pb. They showed ${\alpha}+{\beta}$ phase as a typical microstructure of casting. The ${\delta}$ phase was rarely observed due to the small amount of Sn. These artifacts included more lead than other alloys. They showed segregation like island-shape on the lead part. Wrought products used for daily too1s. were alloy of 80% Cu and 20% Sn. Since they were consist of ${\alpha}$ phase and martensite ${\beta}$ phase, it could be presumed that they were heat-treated. The production method could be identified from twinned grains in ${\alpha}$ phase. Lead was not included in because it had a bad effect to alloy. The bells were alloyed with 85% Cu, 10% Sn, 5% Pb or 90% Cu and 10% Sn. They show the dendrite structure because they were cast and alloyed with many tin. Weldinged were alloyed with 83% Cu, 12% Sn and 5% Pb. lt showed the fine dendrite structure because of fast cooling in air.

  • PDF

The Effects of Urban Forest on Summer Air Temperature in Seoul, Korea (도시림의 여름 대기온도 저감효과 - 서울시를 대상으로 -)

  • 조용현;신수영
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.4
    • /
    • pp.28-36
    • /
    • 2002
  • The main purpose of this study was to estimate a new regression model to explain the relationship between urban forest and air temperature in summer, 2001. This study consists of two parts: correlation coefficient analysis and regression analysis. According to correlation coefficient analysis, thermal infra-red radiations of the major land use categories found significant difference in each category. However there were no significant relationship between the data (thermal infra-red radiation and NDVI) derived from Landsat-7 ETM+ image and air temperature at Automatic Weather Stations(AWSs). After estimating various regression models for summer air temperature, the final models were chosen. The final regression models consisted of two variables such as forest m and traffic facilities area. The regression models explained over 78% of the variability in air temperatures. The regression models with variables of forest area and traffic facilities area showed that the coefficient of the first variable was even more significant than the second one. However, the negative impact of the traffic facilities area was slightly greater than the positive impact of the forest area. Consequently, the effects of forest area and traffic facilities area were apparent to explain summer air temperature in Seoul. Therefore two policies have the most important implications to mitigate the summer air temperature in Seoul: to expand and to conserve the urban forest; and to change the Oafnc facilities'characteristics. The results from this study are expected to be useful not merely in informing the public that urban forest mitigates summer air temperahne, but in urging the necessity of budgets for trees and managing urban forests. It is recommended that field swey of summer air temperature be Performed for the vadidation of the models. The main purpose of this study was to estimate a new regression model to explain the relationship between urban forest and air temperature in summer, 2001. This study consists of two parts: correlation coefficient analysis and regression analysis. According to correlation coefficient analysis, thermal infra-red radiations of the major land use categories found significant difference in each category. However there were no significant relationship between the data (thermal infra-red radiation and NDVI) derived from Landsat-7 ETM+ image and air temperature at Automatic Weather Stations(AWSs). After estimating various regression models for summer air temperature, the final models were chosen. The final regression models consisted of two variables such as forest m and traffic facilities area. The regression models explained over 78% of the variability in air temperatures. The regression models with variables of forest area and traffic facilities area showed that the coefficient of the first variable was even more significant than the second one. However, the negative impact of the traffic facilities area was slightly greater than the positive impact of the forest area. Consequently, the effects of forest area and traffic facilities area were apparent to explain summer air temperature in Seoul. Therefore two policies have the most important implications to mitigate the summer air temperature in Seoul: to expand and to conserve the urban forest; and to change the traffic facilities'characteristics. The results from this study are expected to be useful not merely in informing the public that urban forest mitigates summer air temperature, but in urging the necessity of budgets for trees and managing urban forests. It is recommended that field survey of summer air temperature be Performed for the vadidation of the models.

An Analysis of Cold Air Generation Area Considering Climate-Ecological Function -A Case Study of Changwon, South Korea- (기후생태적 기능을 고려한 찬공기 생성지역 분석 -창원시를 대상으로-)

  • Song, Bong-Geun;Park, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.13 no.1
    • /
    • pp.114-127
    • /
    • 2010
  • The purpose of this study is to find out cold and fresh air producing areas using climate-ecological functions in Changwon city, Gyeongsangnam-do, South Korea. The evaluation of climate-ecological functions were composed of the six factors: patch size with cold air generation and inflow functions, farmland and grassland ratio, mean slope degree, cross section types, mean slope length and roughness of bottom in valley. The analysis results of each evaluation factor in the study area were divided into 5 grades according to the capacity of cold air generation. The first-grade area with the highest factor values for cold air generation was take up 3.51% of the total study area, second grade was 13.48%, third grade was 31.65%, fourth grade was 27.28%, and fifth grade was 24.09%. According to the spatial distribution of cold air producing areas, the valleys around Mt. Bongnim, Changwon tunnel, and Anmin tunnel had higher evaluation grade. It will require the future research to establish the climate-ecological conservation areas and to construct the wind corridor based on the long-term microclimatic monitoring.

Design of Energy Model of Greenhouse Including Plant and Estimation of Heating and Cooling Loads for a Multi-Span Plastic-Film Greenhouse by Building Energy Simulation (건물에너지시뮬레이션을 활용한 연동형 온실 및 작물에너지모델 설계 및 이의 냉·난방부하 산정)

  • Lee, Seung-No;Park, Se-Jun;Lee, In-Bok;Ha, Tae-Hwan;Kwon, Kyeong-Seok;Kim, Rack-Woo;Yeo, Uk-Hyeon;Lee, Sang-Yeon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.123-132
    • /
    • 2016
  • The importance of energy saving technology for managing greenhouse was recently highlighted. For practical use of energy in greenhouse, it is necessary to simulate energy flow precisely and estimate heating/cooling loads of greenhouse. So the main purpose of this study was to develope and to validate greenhouse energy model and to estimate annual/maximum energy loads using Building Energy Simulation (BES). Field experiments were carried out in a multi-span plastic-film greenhouse in Jeju Island ($33.2^{\circ}N$, $126.3^{\circ}E$) for 2 months. To develop energy model of the greenhouse, a set of sensors was used to measure the greenhouse microclimate such as air temperature, humidity, leaf temperature, solar radiation, carbon dioxide concentration and so on. Moreover, characteristic length of plant leaf, leaf area index and diffuse non-interceptance were utilized to calculate sensible and latent heat exchange of plant. The internal temperature of greenhouse was compared to validate the greenhouse energy model. Developed model provided a good estimation for the internal temperature throughout the experiments period (coefficients of determination > 0.85, index of agreement > 0.92). After the model validation, we used last 10 years weather data to calculate energy loads of greenhouse according to growth stage of greenhouse crop. The tendency of heating/cooling loads change was depends on external weather condition and optimal temperature for growing crops at each stage. In addition, maximum heating/cooling loads of reference greenhouse were estimated to 644,014 and $756,456kJ{\cdot}hr^{-1}$, respectively.

Estimation of C Storage and Annual $CO_2$ Uptake by Street Trees in Gyeonggi-do (경기도 도시가로수의 탄소저장량과 연간 이산화탄소 흡수량 산정)

  • Park, Eun-Jin;Kang, Kyu-Yi
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.5
    • /
    • pp.591-600
    • /
    • 2010
  • We estimated and compared C storages and annual $CO_2$ uptakes by 9 dominant tree species planted along the streets. DBH and age by tree species were measured in the sites selected considering the planting status and distributions of tree species, and biomass, C storage, growth rate, and annual $CO_2$ uptake were estimated for each species. As a result, L. tulipifera, M. glyptostroboides, P. occidentalis were classified into fast-growing group, P. serrulata, G. biloba, Z. serrata, S. japonica, A. palmatum showed intermediate growth rates, and P. densiflora was slow-growing. Average C storage per tree was 205kgC/tree and ranged from 518kgC/tree(L. tulipifera) to 41kgC/tree(P. densiflora). Average annual $CO_2$ uptake by urban street trees over their lifespan ranged from $7.6kgCO_2$/tree/y to $99.1kgCO_2$/tree/y and L. tulipifera was the greatest, followed by glyptostroboides and P. occidentalis, and P. densiflora was the lowest. Total annual $CO_2$ uptake by all street trees in Gyeonggi-do, estimated based on the annual $CO_2$ uptake by each species, was as small as approximately 0.67% of that by forest in Gyeonggi-do. However, urban trees are still important because forest area continues to decrease and urbanization occurs annually in Gyeonggi-do, and should be managed considering their multi-functional aspects, including mitigation of heat island effect and building energy saving(indirect $CO_2$ uptake).

The Analysis of Instantaneous $CO_2$ Uptake and Evapotranspiration of Herbaceous Plants for Artificial Roof Greening (옥상녹화용 초본식물의 순간 $CO_2$ 흡수 및 증발산량 분석)

  • Ahn, Geun-Young;Han, Seung-Won;Lee, Eun-Heui
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.1
    • /
    • pp.91-101
    • /
    • 2011
  • The purpose of this study is to demonstrate the positive effects of artificial ground greening on the reduction of carbon dioxide ($CO_2$) which can help improve ecological functions in cities and mitigation of climate change, through quantifying $CO_2$ uptake and evapotranspiration by the process of photosynthesis of some plants. Experiment of $CO_2$ uptake and evapotranspiration was conducted by measurement of $CO_2$ exchange rate using the infrared gas analyzer, for 7 month, growing season from May to November 2009, 2 times a month. The result was as follows; The $CO_2$ uptake quantity per $cm^2$ of Chrysanthemum zawadskii was the highest rate at $21.47{\times}10^{-6}g/cm^2/s$ and Poa pratensis was $16.20g{\times}10^{-6}g/cm^2/s$. The stronger was light of intensity, the higher were $CO_2$ uptake rate of most plants. In quantity of evapotranspiration, Poa pratensis was the highest rate at $8.75{\times}10^{-5}g/cm^2/s$ and Aquilegia buergariana was $8.66{\times}10^{-5}g/cm^2/s$. From this study, it is confirmed that artificial ground greening has capacity of absorption $CO_2$ and effects on improving urban microclimate.

Analysis of Vertical Structure of Atmosphere on the Middle Part of the Yellow Sea (서해 중부 해상 대기의 연직구조 분석)

  • Yun, Yong Hun;Im, Ju Yeon;Kim, Baek Jo;Kim, Tae Hui;Seo, Jang Won;Jo, Ha Man
    • Journal of the Korean earth science society
    • /
    • v.21 no.1
    • /
    • pp.22-22
    • /
    • 2000
  • To search out the characteristics of the lower and the upper atmospheric vertical structure, we selected the island(Oeyoundori Ochun-myen Poryeng city Chung-Nam) as an observation site, which is thought to represent the characteristics of ocean well, and observed the vertical structure of the atmosphere by Radiosonde. By using the results of the observation, we analyzed the changes of relative humidity(RH), temperature and wind when the cyclone and the anticyclone passed and compared the results in case of each event. To compare the vertical structure of the ocean atmosphere with those of the continent, we analyzed the values observed with using Radiosonde at Osan site.Through this study, we found that relative humidity changed as the cyclone and the anticyclone passed. That is, when the cyclone came, RH increased first in the upper atmosphere than in the lower and when the high came, RH in the upper decreased sharply to 10%. And the variations of relative humidity in ocean are bigger than those in continent. In the future, we plan to find out the relation between the vapor water in ocean and continent seasonally and daily through the observation in ocean and continent at same time.

Analysis of Vertical Structure of Atmosphere on the Middle Part of the Yellow Sea (서해 중부 해상 대기의 연직구조 분척)

  • Youn, Yong-Hoon;Lim, Joo-Yun;Kim, Baek-Jo;Kim, Tae-Hee;Seo, Jang-Won;Cho, Ha-Man
    • Journal of the Korean earth science society
    • /
    • v.21 no.1
    • /
    • pp.23-39
    • /
    • 2000
  • To search out the characteristics of the lower and the upper atmospheric vertical structure, we selected the island(Oeyoundori Ochun-myen Poryeng city Chung-Nam) as an observation site, which is thought to represent the characteristics of ocean well, and observed the vertical structure of the atmosphere by Radiosonde. By using the results of the observation, we analyzed the changes of relative humidity(RH), temperature and wind when the cyclone and the anticyclone passed and compared the results in case of each event. To compare the vertical structure of the ocean atmosphere with those of the continent we analyzed the values observed with using Radiosonde at Osan site. Through this study, we found that relative humidity changed as the cyclone and the anticyclone passed. That is, when the cyclone came, RH increased first in the upper atmosphere than in the lower and when the high came, RH in the upper decreased sharply to 10%. And the variations of relative humidity in ocean are bigger than those in continent. In the future, we plan to f d out the relation between the vapor water in ocean and continent seasonally and daily through the observation in ocean and continent at same time.

  • PDF