• 제목/요약/키워드: Heat-care

검색결과 158건 처리시간 0.021초

폭염대비 독거노인을 위한 u-Care 서비스 제안 (u-Care Service for Elderly People Living Alone to Prepare for Extreme Heat)

  • 김지영;김정옥;박승룡;허용;류기윤
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.343-347
    • /
    • 2008
  • In Korea it continues to grow elderly population, especially the elderly who lived alone and above-average temperatures is increased by global worming lately. So that, to take immediate action and to solve social isolation for elderly people living alone, we prospect it plays an important role ubiquitous information technology(IT) such as Geosensor based on GIS, RFID and wireless sensor networks, etc. In this paper, we searched domestic and foreign response status of heat wave for the elderly and proposed u-Care service for the elderly to stay indoors during heatwave warning. In future, we will design u-Care system and carry out various researches on accuracy, revitalization, the law, etc.

  • PDF

히트펌프에서 탄화수소냉매 적용에 관한 실험적 연구 (An Experimental Study on Application of Hydrocarbon Refrigerants for Heat Pump)

  • 유성연;박동성;강태석;이제묘
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1264-1269
    • /
    • 2004
  • This research describes the application of hydrocarbon refrigerants for heat pump system which is needed for fish farm. Tested refrigerants are HCFC-22 and hydrocarbon refrigerants(CARE 50 and ASR-20). CARE 50 is mixture of R-290 and R-170, and ASR-20 is mixture of R-152a, R-290 and other additives. Heat pump consist of shell and tube heat exchanger, scroll compressor, expansion valve and accumulator. Manual expansion valve is used for testing of wide range evaporating temperature. Hydrocarbon refrigerants show a good performance as an alternative for HCFC-22 in the range of evaporating temperature from $-6^{\circ}C$ to $6^{\circ}C$.

  • PDF

일반인의 냉온요법에 대한 인식 조사 (The study of recognition on cold and heat application of the adult)

  • 김민정
    • 기본간호학회지
    • /
    • 제6권3호
    • /
    • pp.452-463
    • /
    • 1999
  • This study was performed to inquire into recognition of cold and heat application. The subjects in the study were 429 adults who were collected by disproportional quota sampling according to age, sex. The instrument was 36 questions that constitured closed questions and semiopened questions that encluded general characteristics, recognition of cold and heat applications. and what will you do when requested cold and heat applications on abdomial and perineal areas. Data were collected from september 25 to October 25, 1998. Data was analysed by SPSS/win, into frequency, Pearson correlation, t-test, ANOVA. The results were following. 1) The subjects consisted of male and female who was from teenage to fifty year old above. According to general characteristics, who endureed moderate cold-heat application, had constitutional fever, good sweat, and taked a cold bath accationally. And the woman think that their body were more cold than man. and the number of cold bath was less than man. Woman felt more harder than man that endured exposing cold. According to the recognitions of cold-heat applications, the 61.9% of the subjects think that cold application is more positive, and the 61.7% of the subjects think that heat application is more positive. 2) The subjects think that oral cavity, abdomen, back, extremes must be warm. 3) The percents of cold or heat application at abdomen were 77.4%, 86.5% respectely and the percents of cold or heat application at perineum were 56.9%. 93.6% respectely. With the above results. we know that the subjects have the fixed perceptions that each body part has to maintain its temperature. especially, they think that postpartum care is correlated with cold-heat application. So when we intervent nursing care, we also must regard their recognitions of cold and heat applications. and we need to educate and explain correctly about cold-heat application.

  • PDF

림프부종 환자의 자가관리에 관한 실태 조사 (A Study on Self-care among the Lymphedema Patients)

  • 조명옥;정향미;전점이;손수경;우영자;노미영;박순옥
    • 성인간호학회지
    • /
    • 제15권3호
    • /
    • pp.383-392
    • /
    • 2003
  • Purpose: The purpose of this descriptive study was to gain basic data to develop a self-care protocol for the lymphedema patients. Method: The subjects of this study consisted of 115 patients with lymphedema from 8 hospitals and two community health and welfare centers in Busan and Seoul. The data was collected with questionnaire by self reporting of patients between March 2001 and December 2001. Data was analyzed by mean and percentage. Result: For self-care activities in daily life, compliance of 'use skin care preparations', 'use heat and cold', 'protect from local compression on affected limbs', 'protect from insect biting', 'use aids to protect affected limbs', 'take diuretics and take protein diet' did not reach to 50%. For self-care activities related to complex physical therapy, 28.7% of subjects complied with compression garment, 14.8% with manual lymph drainage, and 13.0% with exercise. 20.0% of subjects tried to treat with acupuncture and 13.9% with heat therapy. Conclusion: From this study, it is suggested that patients need to get a self-care education with correct information about self care activities and health care professionals need to develop more convenience self-care techniques of massage and exercise.

  • PDF

산후조리원 이용 산모의 산후조리 인지도와 수행도 (A Study on the Level of Recognition & Performance of Traditional Postpartal Care for postpartal Women in Postpartum Care Center)

  • 박심훈;김현옥
    • 여성건강간호학회지
    • /
    • 제8권4호
    • /
    • pp.506-520
    • /
    • 2002
  • The purpose of this study is to research the degree of recognition & performance of traditional postpartal care for postpartal women and to provide the basic data for improvement of service in a postpartum care center. The respondents of this study were 100 women of 6 postpartum care centers within a C province from Oct. 20 to Dec. 10, 2000. The instruments of measure were used for collecting data on the degree of recognition & performance of traditional postpartal care developed by the researcher. Data analysis consisted of frequency, percentage, mean, standard deviation, paired t-test, t-test, ANOVA which are calculated by Scheffe test and Cronbach's alpha which is used as a reliance level by using a SPSS-PC+. The results of the study were as follows:1. The average score for the degree of recognition of traditional postpartal care(Sanhujori) for postpartal women was $3.09{\pm}.31$, and they recognized that it was important. The methods which were ranked were as follows; Protecting the body from a harmful state, invigorating the body by the argumentation of heat and avoidance of cold, handling with whole heart, and keeping clean, resting without working, eating well. 2. The average score for the degree of performance of traditional postpartal care (Sanhujori) for postpartal women was $2.81{\pm}.31$, and they performed that it was important, too. The methods which were ranked were as follows; Protecting the body from a harmful state, invigorating the body by the augumentation of heat and avoidance of cold, eating well, handling with whole heart, and keeping clean, resting without working. 3. There were significant differences statistically (paired-t=-8.39, p=.000) of the degree of recognition & performance of traditional postpartal care(Sanhujori) for the postpartal women. The degree of recognition was higher than the degree of performance. So, the recognition of traditional postpartal care (Sanhujori) was higher than the performance of it. 4. There were no statistical differences of the degree of recognition & performance of traditional postpartal care(Sanhujori) among the postpartal women's age, religion, job, educational background, delivery frequency, delivery method or the sex of baby. So, the Characteristics of the respondents were not influenced as far as the degree of recognition & performance of traditional postpartal care(Sanhujori). 5. There were significant differences statistically of the degree of performance of traditional postpartal care(Sanhujori) among the 5 postpartum care centers except 1 postpartum care center(p<.01). So, the recognition of traditional postpartal care(Sanhujori) was higher than the performance of traditional postpartal care(Sanhujori) in the 5 postpartum care centers. But there was performed as good as recognition in only 1 postpartum care center.

  • PDF

원자력발전소 기기냉각수계통의 판형열교환기 적용성 (Applicability of Plate Heat Exchanger to Plant Cooling Water Systems in Pressure Water Reactor)

  • 임혁순
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.505-510
    • /
    • 2001
  • Advanced Pressurized Reactor 1400(APR1400), which is a standard evolutionary advanced light water reactor(ALWR), has been developed from 1992 as one of long-term Government Project(G-7). The APR-1400 is designed to operate at the rated output of 4000MWt to produce an electric power output of around 1450MWe. Due to the increased electric power, In Nuclear Power plant huge quantities of heat are generated in the thermo-dynamic process used for producing electrical energy. So, There is considerationly additional cooling, Heat transfer area and increased cooling water of Heat Exchanger which take care of the different smaller cooling duties within the nuclear power plant. We review applying to PRE instead of Shell-and-Tube Heat exchanger. In this paper, we describe the major design features of PRE, Comparison between a PHE and a Shell-and-Tube Heat Exchanger, and then Applicability of Plate Heat Exchanger in Nuclear Power Plant Component Cooling water systems.

  • PDF

고강도 콘크리트의 수화열 저감에 미치는 혼화재 종류 및 대체율의 영향에 관한 연구 (A Study on the Effect of Admixture Types and Replacement Ratio on Hydration Heat Reduction of High-Strength Concrete)

  • 김무한;최세진;오시덕;김용로;이종호
    • 한국건축시공학회지
    • /
    • 제2권2호
    • /
    • pp.145-150
    • /
    • 2002
  • The hydration of cement paste occurs when the cement is miked with water. During the hydration, hydration heat causes the thermal stress depending on the site of concrete and the cement content. Especially in the high-strength concrete, we must give care to the concrete due to its large cement content. In this study conduction calorimeter and concrete insulation hydration heat meter were used to investigation the hydration heat characteristics of cement and concrete. To reduce hydration heat of high-strength concrete, several types of replacement of fly-ash and blast-furnace slag powder were used in this experiment. As a result of this study, it was found that hydration heat of high-strength concrete was reduced by replacement of fly-ash and blast-furnace slag powder. In case of high-strength concrete using blast-furnace slag powder, the max-heat arrival time was delayed but an effect of heat reduction was lower than a case of high-strength concrete using fly-ash, because it was considered that the heat-dependence property of blast-furnace slag powder was higher than that of fly-ash.

놀이방 퍼즐매트의 화재위험성에 관한 연구 (A Study on the Fire Hazards of Puzzle Mats in Group Day Care Home)

  • 박형주
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.73-78
    • /
    • 2008
  • The fire hazards and combustion heat of puzzle mats in group day care home were analysed using variable external irradiation level. The fire hazards such as ignition time, ignition temperature, mass loss rate, and flame temperature profile were measured. Incident heat fluxes of $15kW/m^2$, $20kW/m^2$, $25kW/m^2$, $35kW/m^2$, $50kW/m^2$ and $75kW/m^2$ were selected for these experiments. All samples were tested in the horizontal orientation and were wrapped in a single layer of aluminium foil. Each sample was nominally 20mm thick and 100mm square. Five samples of puzzle mat were tested in the study : Type A, B, C, D and E. Type A, B and C are all general grades whereas Type D and E are both Flame retardant grades. As results, Type E of FR-grade showed the best characteristics in safety of the early fire from ignition time, critical heat flux, and ignition and flame temperature data of this study. All specimen of G-grade(Type A, B and C), however, showed the weak in safety of fire.

열감지장치의 응답시간지수와 경계구역 (Installed Spacing and Reponse Time Index of Heat Detection Devices)

  • 권오승;이복영;김동석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1996년도 학술발표회
    • /
    • pp.72-75
    • /
    • 1996
  • The objectives of this paper investigate the effect of installed spacing on the activation of spot type heat detection devices. The flow of hot gases under a ceiling resulting from the impingement of a fire plume activates heat detectors and sprinklers. Local temperature and velocity in this ceiling jet are usually expressed with the function of a ceiling height, the distance from a fire location and the heat release rate of fire. And detectors having different. RTI respond in different ways to the same temperature and velocity of ceiling jet. Thus great care should be taken to decide installed spacing of heat detection devices by considering above effects.

  • PDF

혼화재 종류 및 대체율에 따른 고강도콘크리트의 수화열 저감 효과 (Reducing effect for Hydration Heat of High-Strength Concrete according to Admixture Types and Replacement Ratios)

  • 유범재;김용로;최세진;김상윤;김상규;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.409-414
    • /
    • 2001
  • The hydration of cement paste occurs when the cement is mixed with water. During the hydration, hydration heat causes the thermal stress depending on the size of concrete and the cement content. Especially in the high-strength concrete, we must give care to the concrete due to its large cement content. In this study, conduction calorimeter and concrete insulation hydration heat meter were used to investigate the hydration heat characteristics of cement and concrete. To reduce hydration heat of high-strength concrete, several types of replacement of fly-ash and blast-furnace slag powder were used in this experiment.

  • PDF