• Title/Summary/Keyword: Heat-Regeneration

Search Result 115, Processing Time 0.021 seconds

Performance Test of Low Temperature Regeneration Polymeric Desiccant Rotor (고분자 제습로터의 저온재생 성능시험)

  • Lee, Jin-Kyo;Lee, Dae-Young;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.629-632
    • /
    • 2009
  • The polymeric desiccant rotor is made from the super absorbent polymer by ion modification. The moisture sorption capacity of the super desiccant polymer(SDP) is 4 to 5 times larger than those of common desiccant meterials such as silica gel or zeolite. It is also known that SDP can be regenerated even at the relatively low temperature. To fabricate the desiccant rotor, firstly the SDP was laminated by coating the SDP on polyethylene sheet. Then corrugated and rolled up into a rotor. The diameter, the depth, the dimensions of the corrugated channel, etc. were pre-determined from numerical simulation on the heat and mass transfer in the desiccant rotor. The dehumidification performance was tested in a climate chamber. The relevant tests were carried out at the process air inlet temperature of $32^{\circ}C$, the regeneration air inlet temperature of $60^{\circ}C$ and the inlet dew-point temperature of both the process air and the regeneration air of $18.5^{\circ}C$, when the rotation period is long, the moisture sorption is not effective. In the desiccant rotor developed in this study, the optimum rotation period is found about 350s at the regeneration temperature of $60^{\circ}C$. It was found from further experiments that the optimum rotation tends to decreases as the regeneration temperature increases. Meanwhile, the outlet temperature of the process air deceases monotonically as the rotation period increases.

  • PDF

Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer (액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구)

  • Choi, K.H.;Yoon, J.I.;Kim, B.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.2
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.

An Experimental Study on the Characteristics of Flame Stabilization in a Small Heat-Regenerative Combustor of Counter-Current Channels (대향류 채널 소형 열재생 연소기의 화염안정 특성에 관한 실험적 연구)

  • Cho, Sang-Moon;Kim, Nam-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.491-498
    • /
    • 2007
  • Flame characteristics of a methane-air premixed flame stabilized in a heat-regenerative small combustor were investigated experimentally. A small combustor having two counter-current shallow channels and a combustion space at one side was developed. In which the channel-gap was less the ordinary quenching distance of a stoichiometric methane-air premixed flame. Two design parameters of channel gap and thickness of the middle wall, which is located between two channels for unburned and burned gases, were varied. Flame stabilization conditions and characteristic flame behaviors were experimentally examined. Conclusively, Blowout conditions were governed mostly by the scale of the combustion space, and flashback conditions into the channel are dominated by the channel gap. Surface temperatures of the combustor were between 100 to 500$^{\circ}C$. Additionally, two distinctive flame stabilization modes of radiation and well-stirred?reaction were observed and their applicability was discussed.

Thermal Performance Simulation of Cogeneration Power Plants (열병합 발전플랜트의 열성능 해석)

  • Lee, Dong-Won;O, Myeong-Do;Lee, Jae-Heon;Jo, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.451-460
    • /
    • 2001
  • An analysis program for the thermal performance prediction of steam turbine cogeneration systems with multi-extraction, reheat and regeneration has been developed on the basis of the thermodynamic heat balance method. Heat balance analyses were performed for a commercial cogeneration power plant using the program. Its appropriateness was verified by comparing its heat balance results with those of other commercial programs and those provided by the original system designer. Further parametric analyses were carried out and performance improvement measures in designing the plant were suggested.

A Fundamental Study on the Composition for the Hybrid Dehumidification System Using Thermoelectric Device (열전소자를 활용한 하이브리드 제습시스템의 구성에 관한 기초적 연구)

  • Ryu, Seong-Ryong;Yeom, Ho-Jin;Lee, Hyun-Jae;Cho, Hyun
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.618-626
    • /
    • 2018
  • In this paper, the hybrid dehumidification system using thermoelectric device is based on the idea of utilizing waste heat from the heat dissipation side of thermoelectric device as a heat source to regenerate chemical desiccant. We would like to apply this system to spaces required dehumidification due to continuous moisture generation or local high humidity in the houses. And, we want to confirm the possibility of developing the hybrid dehumidification system that combines passive dehumidification using chemical desiccant with active dehumidification using thermoelectric device.

Thermodynamic Performance Analysis of Ammonia-Water Power Generation System Using Low-temperature Heat Source and Liquefied Natural Gas Cold Energy (저온 열원과 LNG 냉열을 이용하는 암모니아-물 동력 사이클의 열역학적 성능 해석)

  • Kim, Kyoung Hoon;Kim, Kyung Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.6
    • /
    • pp.483-491
    • /
    • 2014
  • In this study, a thermodynamic analysis was carried out for a combined power generation system using a low-temperature heat source in the form of sensitive energy and liquefied natural gas cold energy. An ammonia-water mixture, which is a zeotropic mixture, was used as the working fluid, and systems with and without a regenerator were comparatively analyzed. The effects of the mass fraction of ammonia and the condensation temperature of the working fluid on the system variables, including the net work production, exergy destruction, and thermal and exergy efficiencies, are analyzed and discussed. The results show that the performance characteristics of the system varied sensitively with the ammonia concentration or condensation temperature of the working fluid. The system without regeneration was found to be better in relation to the net work per unit mass of the source fluid, whereas the system with regeneration was better in relation to the thermal or exergy efficiency.

A Study on Reductive Furnace for Copper Annealing Using Catalytic Combustion (촉매연소를 이용한 동 열처리용 환원로에 관한 연구)

  • Jeong, Nam-Jo;Kang, Sung-Kyu;Song, Kwang-Sup;Cho, Sung-June;Yu, Sang-Phil;Ryou, In-Su
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.83-89
    • /
    • 2001
  • Most technologies of reduction process used in the heat treatment of existent metal products are related to metals applied to bolts and parts of automobiles, and nonmetal such as copper. Heating conditions and reduction gases produced in above processes depend on types of products to be treated thermally but heating systems employ electricity commonly and the reduction gases are separated into additional production equipment and a gas dryer and inefficiently provided into the system. Electrical heating system has the advantage of convenient temperature-control but is not economical because of disadvantages of high electricity-running cost and extra installation cost of a transformer. Accordingly, development of the system which has economical heating mode in which provision of reduction gas and heating conditions are unified is necessary for improvement of economy and efficiency in current reduction processes. This study aimed to develop a new advanced heat treatment furnace using catalytic combustion. thereby minimizing the cost during heating, supplying heat and reductive gas at the same time and controlling operating condition freely by changing electrical heating system to heating system by the gas combustion and regeneration of wasted heat.

  • PDF

Comparison of Carbon Dioxide Absorption in Aqueous MEA, DEA, TEA, and AMP Solutions

  • Kim, Young Eun;Lim, Jin Ah;Jeong, Soon Kwan;Yoon, Yeo Il;Bae, Shin Tae;Nam, Sung Chan
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.783-787
    • /
    • 2013
  • The separation and capture process of carbon dioxide from power plants is garnering interest as a method to reduce greenhouse gas emissions. In this study, aqueous alkanolamine solutions were studied as absorbents for $CO_2$ capture. The solubility of $CO_2$ in aqueous alkanolamine solutions was investigated with a continuous stirred reactor at 313, 333 and 353 K. Also, the heat of absorption ($-{\Delta}H_{abs}$) between the absorbent and $CO_2$ molecules was measured with a differential reaction calorimeter (DRC) at 298 K. The solubility and heat of absorption were determined at slightly higher than atmospheric pressure. The enthalpies of $CO_2$ absorption in monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), and 2-amino-2-methyl-1-propanol (AMP) were 88.91, 70.44, 44.72, and 63.95, respectively. This investigation showed that the heat of absorption is directly related to the quantity of heat for absorbent regeneration, and is dependent on amine type and $CO_2$ loading.

Exergy Analysis of Regenerative Ammonia-Water Rankine Cycle for Use of Low-Temperature Heat Source (저온열원 활용을 위한 암모니아-물 재생 랭킨사이클의 엑서지 해석)

  • Kim, Kyoung-Hoon;Ko, Hyung-Jong;Kim, Se-Woong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.1
    • /
    • pp.65-72
    • /
    • 2012
  • Rankine cycle using ammonia-water mixture as a working fluid has attracted much attention, since it may be a very useful device to extract power from low-temperature heat source. In this work, the thermodynamic performance of regenerative ammonia-water Rankine cycle is thoroughly investigated based on the second law of thermodynamics and exergy analysis, when the energy source is low-temperature heat source in the form of sensible energy. In analyzing the power cycle, several key system parameters such as ammonia mass concentration in the mixture and turbine inlet pressure are studied to examine their effects on the system performance including exergy destructions or anergies of system components, efficiencies based on the first and second laws of thermodynamics. The results show that as the ammonia concentration increases, exergy exhaust increases but exergy destruction at the heat exchanger increases. The second-law efficiency has an optimum value with respect to the ammonia concentration.

Regeneration of Intervertebral Disc Using Gellan Sponge Loading PLGA Microspheres (PLGA 미립구가 함유된 젤란검 스폰지를 이용한 추간판 조직 재생)

  • Park, Hyunwoo;Kim, Hye Yun;Kwon, Soon Yong;Khang, Gilson;Kim, Yong-Sik
    • Polymer(Korea)
    • /
    • v.39 no.1
    • /
    • pp.144-150
    • /
    • 2015
  • Gellan gum as a natural polysaccharide has good heat resistance, acid resistance and enzymes resistance. However, one of the drawbacks of gellan gum might be the lower mechanical strength. In this work, gellan gum scaffolds were mixed with poly(lactic-co-glycolic acid) (PLGA) microsphere in order to improve mechanical properties. The gellan gum scaffolds with various contents of PLGA microsphere were prepared for the regeneration of disc tissues. To evaluate the mechanical strength of hybrid structure of gellan gum and PLGA microsphere, compression strength of the fabricated scaffolds was measured. MTT analysis, SEM observation, histological evaluation and RT-PCR were performed to confirm the effect on the cell growth and extracellular matrix secretion. As a result, it showed the best cell proliferation and extracellular matrix secretion in gellan gum sponge containing 50% PLGA microspheres. In conclusion, this study confirmed that the hybrid structure of gellan gum and PLGA microspheres was found suitable in regeneration of the intervertebral disc.