에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구 (The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance)

  • 윤희원;류형규
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.

탄소강관의 ERW 용접부 홈부식 손상에 관한 연구 (A Study on Grooving Corrosion at the Weld of a Low Carbon Steel Pipe Made by Electrical Resistance Welding)

  • 김용;이보영
    • Journal of Welding and Joining
    • /
    • 제22권5호
    • /
    • pp.58-64
    • /
    • 2004
  • Although leakage at a low carbon steel pipe made by electrical resistance welding (ERW) was reported due to grooving corrosion, the cause for the corrosion has not yet been cleared. In order to clarify the main cause, failure analysis on the leaked pipe was carried out, followed by metallographic investigation and corrosion test for the various ERW pipe made with different welding heat input. The microstructure, particularly inclusion content, of the weldment is dependant on the welding heat input applied. For an improper low heat input, the amount of inclusion at the weld was high. High inclusion content accelerated grooving corrosion at the weld. It is therefore that welding heat input should be controlled based on the carbon content of the pipe in order to improve the corrosion resistance of the ERW pipe.

HEAT PIPE TYPE EXHAUST HEAT RECOVERY SYSTEM FOR HOT AIR HEATER

  • Kang, G.C.;Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.654-661
    • /
    • 2000
  • Area of greenhouse increases rapidly up to 45,265ha by the year of 1998 in Korea. Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat of the oil combusted in the furnace. In order to recapture the heat of this exhaust gas and to recycle for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The exhaust heat recovery system was made for space heating in the greenhouse. The system consisted of a heat exchanger made of heat pipes, ${\emptyset}15.88{\times}600mm$ located in the rectangular box of $600{\times}550{\times}330mm$, a blower and air ducts. The rectangular box was divided by two compartments where hot chamber exposed to exhaust gas in which heat pipes could pick up the heat of exhaust gas, and by evaporation of the heat transfer medium in the pipes it carries the heat to the cold compartment, then the blower moves the heat to greenhouse. The number of heat pipe was 60, calculated considering the heat exchange amount between flue gas and heat transfer capacity of heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/hr depending on the inlet air temperature of 12 to $-12^{circ}C$ respectively when air flow rate $1,100\textrm{m}^3/hr$. The exhaust gas temperature left the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the air and the flue gas, the temperature difference was collected by the air and the warm air temperature was about $60^{circ}C$ at the air flow rate of $1,100\textrm{m}^3/hr$. This heat pipe type exhaust heat recovery system can reduce fuel cost by 10% annually according to the economic analysis.

  • PDF

열전소자와 PF Type 진동형 히트파이프를 이용한 냉.난방기에 관한 연구 (The Experimental Study on Cooling-Heating System Using Thermoelectric Module and Parallel Flow Type Oscillating Heat Pipe)

  • 김종수;임용빈;조원호
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.741-747
    • /
    • 2004
  • The purpose of this study was to develop a cooler/heater using a thermoelectric module combined with a parallel flow type oscillating heat pipe with R-142b as a work ing fluid. The experiment was performed for 16 thermoelectric modules (6 A/15 V, size: 40${\times}$40${\times}$4 mm), varying design parameters of the heat pipe (inclination angle, working fluid charging ratio, etc) . Experimental results indicate that the optimum charging ratio and the inclination angle of the parallel flow type oscillating heat pipe were 30% by volume and 30%, respectively. The maximum cooler/heater capacity were 479W (COP : 0.47) and 630W (COP : 0.9), respectively.

Cooling-Heating System Using Thermoelectric Module and Parallel Flow Type Pulsating Heat Pipe

  • Kim Jeong-Hoon;Im Yong-Bin;Lee Seong-Ho;Lee Euk-Soo;Kim Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권4호
    • /
    • pp.217-224
    • /
    • 2005
  • The purpose of this study was to develop a cooler/heater using a thermoelectric module combined with a parallel flow type pulsating heat pipe with R-142b as a working fluid. The experiment was performed for 16 thermoelectric modules (6A/15V, size: $40\times40\times4mm$), varying design parameters of the heat pipe (inclination angle, working fluid charging ratio, etc.). Experimental results indicate that the optimum charging ratio and the inclination angle of the parallel flow type pulsating heat pipe were $30\%$ by volume and $30^{\circ}$, respectively. The maximum cooler/heater capacity were 479 W (COP: 0.47) and 630 W (COP: 0.9), respectively.

히트파이프와 용융염을 사용하는 태양열 축열조의 설계 (Design of a Solar Thermal Storage System Employing Heat Pipes and Molten Salts)

  • 이정륜;부준홍
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.86-91
    • /
    • 2011
  • Thermal design was conducted for a solar thermal storage system in a medium-temperature range between $200^{\circ}C$ and $400^{\circ}C$. The system was composed of heat pipes as heat carrier and molten salts as phase-change storage material. Each heat pipe penetrated through the storage system and had two heat-exchanging sections at both ends to interact with high-and low-temperature steams, while it exchanged heat with molten salts in the middle section. During a heat-storage mode, the heat pipes transferred heat from the hot steam at one side to the molten salts and it transferred heat from the molten salt to the cold steam at the other side during the heat-dissipating mode. A tube-bank type heat exchanger theory was applied to this design task to meet the required inlet and outlet temperatures of the steams depending on the operation modes. Several design variables were considered including the lengths of evaporator and condenser of a heat pipe, traverse and longitudinal pitches of the pipe, and the number of rows of the heat pipes for two different molten salt baths. An optimum design results were presented with discussion.

  • PDF

삽입물에 의한 관내 층류열전달 증진에 관한 실험적 연구 (An Experimental Study on Enhancement of Laminar Flow Heat Transfer in a Circular Pipe with Inserts)

  • 권영철;장근선;정지환
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.667-673
    • /
    • 2000
  • In order to understand the laminar flow heat transfer enhancement by the swirl flow, the effects of heat transfer in a circular pipe with a twisted tape insert were investigated experimentally. In the present study, the uniform heat flux condition was considered. The laminar heat transfer correlations were developed using the least-square-fit from the surface temperature distribution of an electrically-heated pipe and flow property data. Average Nusselt number correlations with the twisted tape insert were expressed as a function of swirl parameter, Reynolds number and Prandtl number. In the case of the twisted ratio y = 6.05, the mean Nusselt number increased approximately 500% and the friction factor increased approximately 300%, compared to the case of the empty pipe, respectively.

  • PDF

대체 난방용 히트파이프 온도 제어 시스템 설계에 관한 연구 (A Study on the Temperature Control System Design of Heat Pipe for Alternative Heating)

  • 윤석암;서장수;조경재;차인수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.908-912
    • /
    • 2003
  • The waste heat recovery system using heat pipe was tested for the consideration of developing the high-efficiency waste heat recovery technology. Heat pipe, a effective device that can quickly transfer large amounts of heat energy using the phase change of the working fluid and the characteristics of Electric Heater Bars used for alternative heating system are introduced In this paper. In order to increase energy efficiency, the system which controls the status of electric heater bars and the temperature of heat pipe installed has developed.

  • PDF

2 성분 혼합물을 작동유체로 사용하는 태양열 집열기용 히트파이프의 실험적 연구 (An Experimental Study of a Heat pipe with Binary Mixture Working Fluid for Solar Collector)

  • 정의국;부준홍;정원복
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.13-18
    • /
    • 2003
  • Heat pipes with binary mixture fabricated and tested for applications where condenser temperature is in a range of $10^{\circ}C$ to $130^{\circ}C$. The pipe materials 8.0 mm O.D. cupper tube and the working fluids are ethanol-water mixtures. The total length of test of the heat pipe was 1710mm in which evaporator section was 1570mm, adiabatic section was 50mm and condenser section was 90mm. Mixing ratios of ethanol and water could be variable in mole fraction. Temperature of condenser section was $10^{\circ}C$, $80^{\circ}C$ and $130^{\circ}C$. Heat pipe performance experimental study was accomplished with change of mixing ratio in these temperatures. The fill charge ratio was 20% of the heat pipe volume. Wick structure was woven-wire and method of experimental work was that thermal load was increased 20W step until the heat pipe wall temperature reached at $150^{\circ}C$. Results were following: At coolant $10^{\circ}C$ and $130^{\circ}C$, mixing ratio that have beat thermal performance was 0.8M+ and at coolant $80^{\circ}C$, was 0.3 ${\sim}$ 0.5 M+.

  • PDF

히트파이프를 사용한 태양열 축열시스템의 성능모사 및 해석 (Performance Simulation and Analysis of the Solar Thermal Storage System Using Heat Pipe)

  • 정의국;부준홍;김종규;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.80-85
    • /
    • 2009
  • Mathematical modeling and performance simulation results were shown for the solar thermal storage system which used heat pipe. The thermal storage system was composed of thermal storage tank and charging/discharging heat exchanger with one by the heat pipes. Heat pipe heat exchanger was attached to system, and could carry out charging and discharging to thermal storage tank at the same time. Height of the thermal storage tank was 600 mm, and that of the charging/discharging heat exchanger was 400 mm. Length of the heat pipe was the same as the total height of thermal storage system, and outer and inner diameter were 25.4 mm(O.D.) and 21.4 mm(I.D.) respectively. Diameter of the circular was 43 mm(O.D.), and fin geometries were considered as the design parameters. High temperature phase change material(PCM), $KNO_3$ and low temperature PCM, $LINO_3$ were charged to storage tank to adjust working temperature. Total size of thermal storage system able to get heat capacity more than 500 kW was calculated and the results were shown in this study. Number of heat pipe was required more than maximum 500, and total length of thermal storage system was calculated to the more than maximum 3 m at various condition.

  • PDF