• Title/Summary/Keyword: Heat spreading

Search Result 109, Processing Time 0.036 seconds

Fabrication of Bulk High-Tc Superconductor (벌크형 고온 초전도 합성)

  • Lee, Sang Heon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.333-336
    • /
    • 2021
  • Oxide YBCO bulk superconductors are manufactured using the melt process. Because seed crystal growth method utilizes a slow-spreading layer-by-layer reaction, a long-term heat treatment is required to manufacture a single-crystal specimen of several cm. In this study, the melt process method was applied to compensate for the shortcomings of the seed crystal growth method. The thickness of the upper and lower pellets of the YBCO bulk was molded to 40 mm, and YBCO superconductor was produced by heat treatment. The measurement results of capture magnetism was in line with the literature. This results in a relationship that the higher the growth of Y211 particle in the YBCO, the higher the superconducting properties. We analyzed the YBCO superconductor, focusing on the Y2BaCuO5 particle distribution.

Recent Tectonism in the Korean Peninsula and Sea Floor Spreading (한반도(韓半島)의 신기(新期) 지형운동(地穀運動)에 관(關)하여)

  • Park, Byong Kwon;Kim, Suh Woon
    • Economic and Environmental Geology
    • /
    • v.4 no.1
    • /
    • pp.39-43
    • /
    • 1971
  • The Korean Peninsula is located between the tectonically stable Asian Continent and the tectonically active Japanese islands. The east coast of Korea shows evidence of uplift whereas the west coast shows evidence of submergence. However, radiocarbon dates indicate that the rate of submergence of the west coast of Korea is slower than the tectonically stable east coast of North America. Therefore, both east and west coasts of Korea might have been uplifted during the last post-glacial period. This uplift may result the spreading line of the from compressional strain produced along East Sea of Korea (Japan Sea) and/or the conversion hinge line of the Pacific mantle convection current plunging beneath the Asian continent. This downturn is supposed to be located in the Japan Trench. High heat flow near the east coast of Korea produces the differential strain. This strain accelerates the compressional strain of the peninsula. The Sea Floor Spreading Theory can explain the tectonism of the Korean Peninsula in Recent time. Baek-Doo Mt. and Han-Ra Mt., dormant volcanoes, may be an evidence of westward movement of the Korean Peninsula.

  • PDF

Investigation of Geothermal Sites in Korea (한국의 지열부지에 관한 연구)

  • Kim, So Gu
    • Economic and Environmental Geology
    • /
    • v.18 no.2
    • /
    • pp.167-175
    • /
    • 1985
  • Geothermal heat flow distribution of Korea is investigated in the light of geophysical data, seismicity, tectonics and gravity as well as heat flow measurements and surface temperature of hot springs. The average heat flow in Korea is found to be $1.65{\mu}cal/cm^2{\cdot}sec$ that is greater than the world's average ($1.5{\mu}cal/cm^2{\cdot}sec$). The high heat flow is located at the regions of high seismicity in Korea. They are found to be Bugok of south central, and Haeundae, Pohang and Dongnae of the southest coast in the Peninsula. The anomalously high heat flow, equal to or greater than $1.93{\mu}cal/cm^2sec$ is found in the Kyongsang Basin, indicating that it is extended from the spreading of the East Sea (Japan Sea) and its origin.

  • PDF

Empirical Modeling of Fouling Rate of Milk Pasteurization Process : A case study

  • Budiati, Titik;Wahyono, Nanang Dwi;Hefni, Muh.
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • Fouling in heat exchanger becomes a major problem of dairy industry and it increases the production cost. These are lost productivity, additional energy, additional equipment, chemical, manpower, and environmental impact. Fouling also introduces the risk of food safety due to the improper heating temperature which allow the survival of pathogenic bacteria in milk, introducing biofilm formation of pathogenic bacteria in equipments and spreading the pathogenic bacteria to milk. The aim of this study is to determine the fouling rate during pasteurization process in heat exchanger of pasteurized milk produced by Village Cooperative Society (KUD) "X" in Malang, East Java Indonesia by using empirical modeling. The fouling rate is found as $0.3945^{\circ}C/h$ with the heating process time ranged from 0 to 2 hours and temperature difference (hot water inlet temperature and milk outlet temperature) ranged from 0.654 to $1.636^{\circ}C$. The fouling rate depends on type and characteristics of heat exchangers, time and temperature of process, milk type, age of milk, seasonal variations, the presence of microorganism and more. This results will be used to plan Cleaning In Place (CIP) and to design the control system of pasteurization process in order to maintain the milk outlet temperature as standard of pasteurization.

Thermal Dispersion Analysis Using Semi-Active Particle Tracking in Near Field Combined with Two-Dimensional Eulerian-Lagrangian Far Field Model (근역에서 부력입자추적모형을 적용한 Eulerian-Lagrangian 결합에 의한 온수확산)

    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.10 no.2
    • /
    • pp.73-82
    • /
    • 1998
  • In order to simulate surface discharged heat dispersion in costal area, a 2-dimensional Eulerian-Lagrangian model for far field and semi-active particle tracking random walk model in near field has been combined. The mass of discharged heat water in near field has treated as particles with buoyancy and this is eventually converted to horizontal additive dispersion in random walk equations. This model is applied to both a simplified coastal geometry and a real site. In simple application it can simulate plume-like characteristics around discharging point than a near field-model, CORMIX/3. Actual application in the Chonsu Bay shows farther spreading of heat water in near field comparing the observed data, and this shows that the developed model might be applied with satisfaction.

  • PDF

Preparation and characterization of expanded graphite/Ag nanoparticle composites for the improvement of thermal diffusion

  • Hong, Seok Hwan;Lee, Won Gyu
    • Korean Chemical Engineering Research
    • /
    • v.56 no.3
    • /
    • pp.410-415
    • /
    • 2018
  • Expanded graphite (EG)/Ag nanoparticle composites were synthesized by the chemical reduction of Ag ions, followed by the addition of expanded graphite into an Ag reducing solution. The prepared composites showed uniform dispersion of Ag nanoparticles on the surface of expanded graphite and exhibited relatively higher thermal conductivities than those of pure expanded graphite. In the case of 10% Ag content in the composite, the thermal conductivity in the thickness direction was 78% higher than the pure expanded graphite. We suggest that EG/Ag nanoparticle composites are a strong candidate for advanced heat spreading material.

Ventilation Effects on Smoke Behavior in Rescue Station for Tunnel Fires (철도터널 화재시 구난역 내의 연기거동에 미치는 배연효과에 관한 수치연구)

  • Jang, Won-Cheol;Kim, Dong-Woon;Ryou, Hong-Sun;Lee, Seong-Hyuk
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2130-2138
    • /
    • 2008
  • The present study investigates the ventilation effects on smoke spreading characteristics in railway tunnels with the rescue stations. Experiments were carried out for n-heptane pool fires with a square length 4 cm at different fire locations, and the heat release rates (HRR) were obtained by the measurement of burning rates. In addition, using the commercial code (FLUENT), the present article presents numerical results for smoke behavior in railway tunnels with rescue station, and it uses the MVHS (Modified Volumetric Heat Source) model for estimation of combustion products resulting from the fire source determined from the HRR measurement. As a result, it is found that smoke propagation is prevented successfully by the fire doors located inside the cross-passages and especially, the smoke behavior in the accident tunnel can be controlled through the ventilation system because of substantial change in smoke flow direction in the cross-passages.

  • PDF

Deflection Characteristics of Permanent Formwork Using Multi-layer Insulation (다층형 단열재를 사용한 영구거푸집의 처짐 특성)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Yong;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.130-131
    • /
    • 2019
  • As part of recent low-energy policies, thermal insulation standards for buildings are being tightened every year. In addition, the conventional styrofoam insulating material has a problem that the thickness of the heat insulating material to achieve a standard heat permeability is rapidly increased. Due to the thick insulation, there is a high risk of spreading vulnerable structures such as fire due to lack of space between buildings. On the other hand, the method of using the insulation as a formwork is known to be excellent cost saving effect through the reduction of the formwork usage and the simplification of the external insulation work. In order to solve this problem, this study aims to fabricate a multi-layered insulator that combines high-performance phenolic foam insulation and styrofoam insulation and evaluate the deflection characteristics for use as formwork.

  • PDF

A Study on the Cooling Performance Improvement of Pouch Battery Thermal Management System for Electric Vehicles (전기자동차 파우치형 배터리 열관리 시스템의 냉각성능 향상에 대한 연구)

  • Shin, Jeong-Hoon;Lee, Jun-Kyoung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.715-724
    • /
    • 2022
  • In many electric vehicles, large-capacity pouch-type lithium-ion battery packs are mainly used to increase the mileage on a single charge. The lithium ion battery should be operated within the temperature range of 25℃ to 40℃ because the battery performance can be rapidly deteriorated due to an increase in internal temperature. Battery thermal management system (BTMS) can give the suitable temperature conditions to battery by water cooling method. In this research, the heat transfer characteristics (the battery temperature distributions and the water flow characteristics) were analyzed by CFD method to investigate the thermal performance of the cooling plate with 4-pass water flow structure. Moreover, the effect of the presence of fins between the battery cell was identified. The fins made smooth temperature distributions between the battery cells due to the heat spreading and lower the average battery cells temperature.

A Study on Fire Spread and Evacuation Risk of Conduit Combustion in Ceiling Hiding Place (천장 은폐장소 전선관 연소에 따른 화재확산 및 피난 위험도에 관한 연구)

  • Park, Kwang-Muk;Jeon, Jae-Kam;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.55-65
    • /
    • 2020
  • In this study, the ISO 5660 and ISO 5659 combustion tests were conducted with synthetic resin conduits (CD, VE) and metal conduit (ST) used for wiring work in electrical facilities, which can be installed in ceiling concealed places. Then, fire spreading and evacuation risks were analyzed based on the measured data. In the ISO 5660 test, CD of 120.5 MJ/㎡, VE of 81.9 MJ/㎡, and ST of 4.9 MJ/㎡ were measured. In the ISO 5659 test, the CD 1320, VE 731, and ST 102 were measured, and then the maximum smoke densities were measured for CD 605 s, VE 740 s, and ST 1,200 s. In terms of fire spreading and evacuation risk, the CD conduit, VE conduit, and ST conduit were in order. In the fire spreading risk analysis, total heat emission was calculated as 4,820 MJ/㎡, 4,267 MJ/㎡, and 196 MJ/㎡ for CD, VE, and ST, respectively. Evacuation risk analysis shows at transmittance of 89%, CD is 127 s, VE is 35 s, and ST is 969 s. At transmittance of 79%, representing almost invisible concentration, CD is 157 s and VE is 50 s. The CD and VE conduits had a high fire spreading and evacuation risks, while the ST conduit had little effect on fire spreading and evacuation risk.