건물 내장재의 화재위험성 평가 방법 (A Fire Hazard Assessment of Interior Finish Materials)

  • 김운형
    • 한국화재소방학회논문지
    • /
    • 제12권2호
    • /
    • pp.17-28
    • /
    • 1998
  • 건물 화재시 예상되는 내장재의 실째 화재성농올 기준으로 한 위험성 명가방법올 제시하였다. 이률 위해 ISO Room Corner Test. (9705)를 기준으로 Qui ntie re의 화재확산 모델을 이용하여 내장재의 열 적 특성과 플래쉬 오버 도달시간과의 상관성을 유도하고 스쩨덴의 실제 시험결과와 비교 분석하였다. 이 결과, 내장재의 상대척인 화재위험성은 화재확산 변수 b륨 기준으로 명가될 수 있었다.

  • PDF

질화규소 요업체의 기지상 결정화가 파괴인성에 미치는 영향 (Effect of Crystallization of Matrix Phase on the Fracture Toughness of Silicon Nitride Ceramics)

  • 김남균;김도연;강대갑
    • 한국세라믹학회지
    • /
    • 제24권4호
    • /
    • pp.364-368
    • /
    • 1987
  • The Si5AION7 specimens containing 20% YAG composition have been sintered and then heat treated to induce the crystallization of the matrix glassy phase. Crystallization of YAG phase during the heat treatment was detected from the X-ray diffraction patterns and the consequent changes in room temperature toughness as well as in microstructures were investigated. Almost all the glassy boundary phase were found to crystallize even after 5 minutes of heat treatment and the KC at room temperature decreased accordingly. The results show that the matrix crystallization can be induced by slow cooling from the sintering temperature.

  • PDF

A Room-Corner Fire Model을 적용한 건축내장재의 화재확산 특성 평가(1)

  • 김운형
    • 방재기술
    • /
    • 통권24호
    • /
    • pp.32-39
    • /
    • 1998
  • A room-corner fire scenario of ISO 9705 with flame spread model developed by Quintiere is applied to the interior finish materials to show the sensitivity of properties derived from AST, E-1321 and ASTM E-1354 is investigated and various range of thermal properties by the author were analyzed in the model. There are including flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The time for total energy release rate to reach 1MW is examined. Though some areas are neede for improvements, The model appears to predict good results with all the range of input properties and could be

  • PDF

궤도차량용 보조동력장치 엔진룸 내부 열유동 특성에 관한 연구 (A Study on Thermal and Fluid Characteristics inside Engine Room of Auxiliary Power Unit for Tracked Vehicle)

  • 이태의;서정세;정상환;박영식
    • 한국정밀공학회지
    • /
    • 제26권12호
    • /
    • pp.85-93
    • /
    • 2009
  • This research is intended to grasp the characteristics of heat flow inside auxiliary power device engine room to obtain the design basic data through numerical analysis and experiment. For experiment cost reduction, numerical analysis was done to obtain quantitative data by observing the change in temperature distribution of major parts according to changes in normal condition, incompressible condition, engine surface heat emission rate and absorption temperature with the use of commercial STAR-CD. The experiment was done by grasping the temperature distribution of major interested parts inside engine room in loaded and unloaded conditions during engine operation. The temperature distribution data here will serve as useful design data during APU engine room designing.

블라인드 설치 위치에 따른 실내열환경 변화에 관한 연구 (A Study on the Change of Indoor Thermal Environment According to the location of Blinds)

  • 황덕수;이경희
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.113-118
    • /
    • 2011
  • In order to prevent incoming solar radiation, it is necessary to study about blinds' blocking out effects of heat that are installed at the balcony at an apartment house. To figure out the heating effects from the windows, a study for indoor thermal environment according to the location of blinds is also needed. In order to find out the changes of indoor thermal environment, we'll compare models of a house building with or without Venetian blinds: one place has an extended living room removing a balcony and another one has a normal balcony. The result is as follows. Without blinds, the place with an extended living room has benefits for saving heat compare to the place with a normal balcony. It's because the warm air heated by the incoming solar radiation moves into the living room through convection current and radiation which causes an increase of the indoor temperature. At an extended living room, the temperature difference from outside and inside, when blinds were installed inside, was $1.9^{\circ}C$ while it was $0.6^{\circ}C$ when the blinds were installed at outside of the balcony. It is evaluated that setting up the blind outside prevents much heat. At the space with a normal balcony, installing blinds at living room windows can save much heat compare to installing blinds at windows at the balcony. The indoor temperature was low when blinds were installed. It can be said that blinds block heat from the incoming solar radiation. Moreover, when blinds are installed, there is a big change of indoor temperature due to the radiation from the blinds' slat and convective activities in between the blinds and windows. This also has to be considered.

열펌프 성능향상을 위한 공기 열교환기 부착효과 (Attachment of the Air Heat Exchanger for COP Improvement in the Heat Pump)

  • 노정근;송현갑;박용규
    • Journal of Biosystems Engineering
    • /
    • 제27권3호
    • /
    • pp.235-240
    • /
    • 2002
  • Performance of the heat pump with attaching an air heat exchanger was investigated in the heating condition when the air heat exchanger was worked in the ambient air temperature of -5 to 11$\^{C}$ and air flow rate of 542 to 747 ㎡/h. Performance tests for heating condition were conducted in an experimental room equipped with heat pump. The performance tests were performed in a ambient temperature of -4 ∼ 11$\^{C}$, and room temperature of 4∼22$\^{C}$ respectively. Measured data(temperature, capacity of heat transfer and consumption of electronic power) were analyzed to the efficiency of HEEVA(Heat Exchanger fur the Evaporator), overall heat transfer coefficient and COP of heat pump. The results of inlet temperature for evaporator increased that the temperature was 2 ∼6$\^{C}$, and inlet temperature for condenser decreased that the temperature was 3 ∼ 8$\^{C}$. The results of comparing efficiency of HEEVA for the ratio of heat exchange between hot air and cold air showed that efficiency were considered to 91% because of the ratio of 83∼98%. The results of comparing of COP for the heat pump increased that improvement COP was approximately 0.3∼7.5 than HEEVA had not been operated.

복사열전달을 고려한 모형 온수온돌 주택 열성능 시뮬레이션 (Simulation of the Thermal Performance on an Ondol House with Hot Water Heating in Consideration of Radiation Heat Transfer)

  • 최영돈;윤종호;홍진관;이남호;강대호
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.295-305
    • /
    • 1993
  • Thermal performance of test cell of model hot water Ondol house was simulated by equivalence heat resistence and heat capacity method. In this method wall was replaced by two equivalence and one heat capacity. This method enables to simulate the variation of temperature of each element of model house. The effect of pipe diameter, pitch of pipe and with or without consideration of inter-radiation between wall surfaces on the energy consumption rate were investgated. Results show that radiations between the ground surface of room and wall surfaces contribute to the heating of room air by reducing the convection heat loss through the wall surfaces.

  • PDF

3차원 실내공간의 가열장애물에 대한 열전달 및 난류유동의 수치해석 (A Numerical Analysis of Turbulent Flow Field and Heat Transfer in a Three Dimensional Room with a Heat Generating Obstacle)

  • 정효민
    • 수산해양기술연구
    • /
    • 제31권1호
    • /
    • pp.107-119
    • /
    • 1995
  • 3차원 실내공간의 상부에서 일정유속이 유입하여 양측면 하부쪽으로 유출될 경우, 책상형의 가열 장애물 영향에 의한 유동장의 변화와 온도분포를 수치계산 한 결과 다음과 같은 결론을 얻었다. (1)표준 k-$\varepsilon$ 2 방정식 모델로 난류유동장을 해석한 결과 장애물을 기준으로 상하부에는 독립적인 큰 재순환 영역이 존재함을 알 수 있었다. (2) 유입류의 속도 변화에 따른 전제적인 유동패턴은 큰 변화없이 상사적인 분포를 하는 것을 알 수 있었다. (3) 유입속도가 감소함에 따라서, 공간에 대한 발열체의 온도영향이 커진다. (4) Re수가 작은 범위 (10 상(4)-10 상(5)에서는 열전달이 급격히 상승하여, Re수가 10 상(5)이상이 도면 열전달이 거의 일정하다.

  • PDF

지하생활공간 화재시 풍속에 따른 열유동 특성 연구 (Experimental Study on Heat Flow According to the Wind Velocity in an Underground Life Space)

  • 김영노;석창목;김화중
    • 한국화재소방학회논문지
    • /
    • 제21권3호
    • /
    • pp.61-68
    • /
    • 2007
  • 본 연구에서는 지하생활공간을 대상으로 풍속의 변화에 대한 축소모델 실험을 통하여 열유동 및 화재성상을 분석하였다. 풍속이 증가할수록 화재실의 온도상승 시간은 빨라지고, 실의 온도도 증가하였다. 그리고 풍속이 증가할수록 화재실의 개구부에서 최고온도를 나타내었다. 화재확산에 따른 열유동은 풍속이 증가할수록 와류확산을 촉진시켜 연기발생과 화염의 크기를 증가시키고, 인근실의 내부보다 통로에서 높은 온도분포를 나타내었다. 끝으로 지하생활공간의 화재시 열유동은 풍향과 풍속에 의해 화재확산이 결정되어지고 풍속이 증가할수록 온도증가와 감소는 빠르게 진행됨을 확인할 수 있었다.

반도체 PR 공정의 클린룸내 CFD 기반 화재 사고 영향 분석 (CFD-based Fire Accident Impact Analysis in Clean Room for semiconductor PR Process)

  • 천광수;이진석;박명남
    • 한국가스학회지
    • /
    • 제25권6호
    • /
    • pp.35-44
    • /
    • 2021
  • 반도체 공정 중 PR (Photo Resist) 공정은 여러 인화성 물질을 혼합하여 사용하는 공정으로, 공정 장비가 Clean Room 내 설치되어 인화성 물질이 누출되는 경우 질식, 화재, 폭발 사고로 이어질 위험성이 크므로, 물질 누출시 발생할 수 있는 사고에 대한 영향을 분석하고, 작업자들의 안전을 보장할 수 있는지 평가하는 것이 필요하다. 본 연구는 FLACS CFD - Fire Module을 이용하여 10개의 누출, 화재 시나리오에 대한 CFD Simulation을 통해 Clean Room 내부 가상으로 설정한 Monitor Point에서의 복사열 및 온도 변화 값을 확인하였다. Clean Room 내부에서 발생한 화재는 층간 구조물에 높은 복사열을 전달하지만, 그 범위가 상당히 제한적이며, 단일 화재 사고로 인해 붕괴될 가능성이 희박하다. 화재 사고로 인해 탈출구로 이어지는 2 곳의 계단이 동시에 높은 복사열에 노출되는 시나리오는 없어, 화재 발생시 작업자가 탈출 가능하였다. 또한 복사열 및 온도 상승의 수준은 아래층으로 이동하면서 급격하게 낮아지는 것을 확인하였으며, API 520의 기준에 따라 작업자가 30초 동안 버틸 수 있는 복사열인 6.31 kW/m2에 노출된 작업자도 화재가 발생한 Clean Room 내부에서 충분히 탈출할 수 있음을 확인하였다.