A Study on the High Temp. Tensile Properties of B1914 Ni-base Superalloy According to Crystal Structures of Poly-, Directionally Solidified- and Single Crystal Casts (Ni기 초합금 B1914의 다결정, 방향성 및 단결정 주조구조에 따른 고온 인장 특성 연구)

  • An, Seong-Uk;Jang,Yong-Seok;Yun, Dong-Han;Im, Ok-Dong;Larionov, V.;Grafas, I.;Jin, Yeong-Hun;Lee, Jae-Hun;Seo, Dong-Lee;O, Je-Myeong;Lee, Sang-Jun;Lim, Dae-Soon
    • Korean Journal of Materials Research
    • /
    • v.8 no.9
    • /
    • pp.831-836
    • /
    • 1998
  • The B1914 Ni-base superalloy was manufactured according to crystal structures of poly-, directionally solidified- and single crystals. We observe deformation as type of different crystal structure from room to high temperature. Specimens are controled by cooling rate and thermal gradient and then heat treatment in vacuum and then cooling with Ar gas. Different crystal structure has different stress-strain characteristic. At $600^{\circ}C$, yield strength and ultimate strength is increased single-, directionally solidified- and poly crystals in order.

  • PDF

Comprehensive Analysis of Exposed Adverse Factors in Disaster Response Activities - Focused on Fire - (재난 대응 활동 시 노출가능 유해인자 종합분석 -화재 현장을 중심으로-)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.3
    • /
    • pp.420-430
    • /
    • 2014
  • Firefighters performing disaster response activities such as Fire Suppression Rescue First Aid in fire are being exposed in various adverse factors, heat, smoke, toxic gases, emotional stress, biological toxic factors and physical overload by unnatural ergonomic posture required for firefighters. But so far, there is the study for this problem only separately. There is no study about comprehesive analysis of exposed adverse factors in fire-related disaster response activities and countermeasures. The purpose of this study is to contiribute to solving the health problems and prevention of accidents of firefighters by extracting hazardous agents in disaster such as fire and by proposing countermeasures. After analyzing circumstances such as fire-suppression, rescue first aid and life-environment, exposure factors of fire are derived and exposure status is suggested according to physical chemical biological psychological aspects. The countermeasure against the noise of the physical exposure factors are proposed. The countermeasures such as protective equipment and clean room in chemical factors, infection prevention education, vaccination and periodic check system in biological factors, PTSD alleviation booth and mentoring in psychological factors are proposed.

Derivation of Optimum Operating Conditions for Electrical Resistance Heating to Enhance the Flushing Effect of Heavy Oil Contaminated Soil (중질유 오염토양의 세정효과를 증진시키기 위한 전기저항가열의 최적 운전조건 도출)

  • Lee, Hwan;Jung, Jaeyun;Kang, Doore;Lee, Cheolhyo
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.3
    • /
    • pp.219-229
    • /
    • 2020
  • This study evaluated the applicability of the convergence technology by deriving the optimum conditions about operating factors of electrical resistance heating to enhance the soil flushing effect on soil contaminated with bunker C oil in the coastal landfill area. As a result of the batch scale experiment, the flushing efficiency of the VG-2020 was higherthan that of the Tween-80, and the flushing efficiency increased by about 1.4 times at 60℃ compared to room temperature. As a result of the electrical resistance heating box experiment, soil temperature rose to 100℃ in about 40~80 minutes in soil with water content of 20~40%, and it was found that the heat transfer efficiency is excellent when the pipe-shaped electrode rod with STS 316 material is located in a triangular arrangement in saturated soil. In addition, it was confirmed that the interval between the electrode rods to maintain the soil temperature above 60℃ under the optimum conditions was 1.5 m, and the soil flushing box experiment accompanying electrical resistance heating showed TPH reduction efficiency of about 55% at 5 Pore Volume, and satisfied the Korean standard for the conservation of soil (less than TPH 2,000 mg/kg) at 10 Pore Volume.

The Properties of Au-Al Alloy Thin Films with a Thermal Evaporator for Purple Gold (퍼플골드를 위한 열증착법으로 제조된 Au-Al 합금 박막의 물성연구)

  • Kim, Jun-Hwan;Song, Oh-Sung
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.5
    • /
    • pp.466-472
    • /
    • 2008
  • Purple Gold is the alloy consisting of 78wt%Au-22wt%Al, and is expressed as a chemical formula, $AuAl_2$. Lately it is being used for the material of accessories or the decorative ornaments, being one of the colored golds having the peculiar purple color, like White Gold and Pink Gold. Purple Gold has the weak point in shaping through casting process due to the bad malleability and castability, being the intermetalic compound of Au and Al. Therefore, it is possible to produce the final product only by the cutting and the grinding process or to use it as a decorative coat with the thin film evaporation. This study implemented two kinds of thin film experiments. One is the case that heat treatment was made after Au and Al deposition evaporated separately with a weight ratio 78:22 on the 200nm$SiO_2$/Si substrate. The other is the case that the surface deposition was made through the vacuum evaporation, keeping the glass substrate temperature remain room temperature, using the bulk $AuAl_2$ as a source. The final film property was measured, focusing on the Purple Gold's color and thickness through the bare eye inspection, the microstructure analysis, the surface resistance analysis, the color difference analysis, and XRD analysis. Purple Gold was not formed, as the excessive surface agglomeration occurred, in case of being produced and treated thermally with 12.5nmAu/40nmAl/200nm$SiO_2$/Si structure. Our results suggest that of Purple Gold films, showing the same purple color as the bulk's, were successfully deposited with the direct thermal evaporation from the $AuAl_2$ bulk source.

A Comparison of Laser Flash and the Divided-bar Methods of Measuring Thermal Conductivity of Rocks (암석 열전도도 측정을 위한 Laser Flash Method와 Divided-bar Method 비교)

  • Oh, Jae-Ho;Kim, Hyoung-Chan;Park, Jeong-Min
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.387-397
    • /
    • 2011
  • In this study, we conducted the study of the merits and demerits of the laser flash and the divided-bar methods for measuring the thermal conductivity of rocks and investigated applicability of the divided-bar apparatus which was developed by KIGAM. The laser flash method can measure thermal diffusivity, specific heat capacity, and thermal conductivity of rocks with even small thickness (< ~3 mm) in the high temperature range($25-200^{\circ}C$) in non-contact mode. For the laser flash method, samples must be uniform and homogeneous. In the case of the divided-bar method, the apparatus measures only thermal conductivity of rock samples at the room temperature. We measured thermal conductivities of 12 rock samples with low density and high porosity using two methods. In the laser flash method, there exist potential errors caused by the effect of pulse dispersion and reflection by various minerals and porosity in rock samples; the difference in thermal conductivity values measured on the front surface and the opposite surface ranges from 0.001 to 0.140 W/mK with the standard deviation of 0.003~0.089 W/mK, which seems to be caused by heterogeneity of rock samples. On the contrary, the divided-bar apparatus shows stable thermal conductivity measurements and relatively small measurement errors; the difference in thermal conductivity values, just as we applied to the laser frash method, is 0.001~0.016 W/mK with the standard deviation 0.001~0.034 W/mK. In turn, the divided-bar method can be applied to more thick samples that are more representative of bulk thermal conductivity.

Acidic and steaming treatments of tteokbokki rice cake to improve its microbial and textural properties (떡볶이 떡의 미생물 안전성 및 식감 향상을 위한 유기산과 증숙 처리)

  • Cheon, Hee Soon;Cho, Won-Il;Lee, Su Jin;Chung, Myong-Soo;Choi, Jun-Bong
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.502-506
    • /
    • 2017
  • To improve the storage and firmness of Tteokbokki tteok Korean-style rice cakes with spicy sauce, steaming of the rice dough, soaking of the rice cake in acidic solution, and heat sterilization were conducted sequentially. The untreated control could be stored for 1 month under cold conditions, but this was extended to 10 months at room temperature ($15-30^{\circ}C$) after immersion in lactic acid solution (pH 4.0) for 20 min and heating to $100^{\circ}C$ for 30 min. The mechanical strength, which was related to firmness, was significantly increased to $11.4kgm/s^2$ compared with the untreated rice cakes ($8.8kgm/s^2$, p<0.05) and the overall descriptions of the sensory evaluation, including texture, was significantly higher than the control (p<0.05). The average size of the pores in the treated rice cakes was smaller than that of the conventional sample and the texture was improved as a result of decreased starch elution from smaller pores.

The Physiological Responses and Subjective Sensation in the Subjects Wearing Dust-free Garment for Semiconductor Industrial Environments (방진복 착용에 따른 인체의 온열생리적 특성 및 주관적 감각)

  • 권오경;이창미
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.255-263
    • /
    • 1998
  • Dust-free garment prevents contamination which otherwise is caused by skin and clothes to protect from dust or dirt. Therefore, it requires high performance and should function as a working clothes. Clothes are a medium between human and thermal environmental system, and it is required to study human enviroment to ensure comfortableness of clothes and to satisfactorily go along with enviroment .This study investigates the physical and physiological features of dust-free garment used in the clean room at a semiconductor factory in oredr to scientifically clarify what the dust-free garmint is as well as to contribute to the design and development of high performance material and clothes. Three kinds of dust-free fabrics (DFG-I, DFG-II, DFG-III) which are being developed by a local company are used to manufacture dust-free garment. These dust-free garments are dressed and tested in such an enviroment as similar to semiconmemts with temperature at 23${\pm}$1$^{\circ}C$ and humidity at 50${\pm}$5%RH in order to investigate the thermo physiological and psychological features of human body. The results of this study are as follows. The results of this study are as follows. 1.The mean skin temperature was significantly different among the clothes, subjects and experimental time. Temperature tends to rise from the time of exercising load. Continuous motion coupled sealed clothes prevents heat transmittance, and temperature rises in the order of DFG-l, DFG-ll and DFG-lll as time course. 2.As for the skin temperature by local timperature is minimun on the head and torso and increares remarkably at the terminal part of human body. 3. As for the body mass loss was significantly higher in DFG-lll than DFG-l and DFG-ll. 4. Though there is no significant difference in the temperature within clothes among the kind of clothes temperature is 1$^{\circ}C$ higher in the back. Temperature within all the dust-free garments 29.7$^{\circ}C$ in the back and 31.3$^{\circ}C$ in the chest which belong to the comfort zone(31-33$^{\circ}C$). The relative humidity is 39.7%RH in the chest and 33.8%RH in the back which is slightly below the comfort zone(40-60%RH) 5. The thermal sensation belong to the comfort zone regardless of the kinds of clothes. The subjects feels a slight fatigue as times goes. As for the subjective sense of subjects the mean skin temperature as well as temperature and humidity within clothes show similar tendency. This means that they relate with each other.

  • PDF

Effects of Annealing Temperature on Interface Properties for Al/Mild Steel Clad Materials (어닐링 온도 변화가 Al/연강 클래드재의 계면 특성에 미치는 영향)

  • Jeong, Eun-Wook;Kim, Hoi-Bong;Kim, Dong-Yong;Kim, Min-Jung;Cho, Young-Rae
    • Korean Journal of Materials Research
    • /
    • v.22 no.11
    • /
    • pp.591-597
    • /
    • 2012
  • For heat exchanger applications, 2-ply clad materials were fabricated by rolling of aluminum (Al) and mild steel sheets. Effects of annealing temperature on interface properties, especially on inter-layer formation and softening of strain hardened mild-steel, for Al/mild steel clad materials, were investigated. To obtain optimum annealing conditions for the Al/mild steel clad materials, annealing temperature was varied from room temperature to $600^{\circ}C$. At the annealing temperature about $450^{\circ}C$, an inter-layer was formed in an island-shape at the interface of the Al/mild steel clad materials; this island expanded along the interface at higher temperature. By analyzing the X-ray diffraction (XRD) peaks and the energy dispersive X-ray spectroscopy (EDX) results, it was determined that the exact chemical stoichiometry for the inter-layer was that of $Fe_2Al_5$. In some samples, an X-layer was formed between the Al and the inter-layer of $Fe_2Al_5$ at high annealing temperature of around $550^{\circ}C$. The existence of an X-layer enhanced the growth of the inter-layer, which resulted in the delamination of the Al/mild-steel clad materials. Hardness tests were also performed to examine the influence of the annealing temperature on the cold deformability, which is a very important property for the deep drawing process of clad materials. The hardness value of mild steel gradually decreased with increasing annealing temperature. Especially, the value of hardness sharply decreased in the temperature range between $525^{\circ}C$ and $550^{\circ}C$. From these results, we can conclude that the optimum annealing temperature is around $550^{\circ}C$ under condition of there being no X-layer creation.

Computer Simulation Study for Analyzing Alternative Refrigerants in Residential Air-conditioners (가정용 냉방기의 대체 냉매 성능 분석을 위한 전산 해석 연구)

  • Yoo, Hwaan-Kyu;Jung, Dong-Soo
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.75-90
    • /
    • 1995
  • This paper is concerned about alternative refrigerants for HCFC22 used in room air conditioners and heat pumps. Computer simulation of residential air conditioners using refrigerant mixtures is carried out. Following refrigerants are selected as the pure refrigerants constituting the mixtures studied: R32, R124, R125, R134, R134a, R143a and R152a. Simulation results are presented fur the following mixtures: R32/R134a, R32/R152a, R32/R134, R32/R124, R143a/R134a, R143a/R152a, R143a/R124, R125/R134a, R125/R152a, R125/R124, R32/R152a/R134a, R32/R152a/R134, R32/R152a/R124. The best fluid is found to be the ternary mixture of R32/R152a/R124. For that mixture, the coefficient of performance(COP) and volumetric capacity for refrigeration(VCR) are 13.7% larger and 23% smaller than the respective values for HCFC22. R32/R124 mixture is the best binary fluid pair whose COP and VCR are 13.4% larger and 9.6% smaller than those for HCFC22.

  • PDF

Evaluation of Combustion gas during Fire Tests of Veneers Coated with Ammonium Salts (암모늄염으로 도포시킨 베니어판의 연소 시에 발생하는 연소가스 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.93-99
    • /
    • 2016
  • This study tested the combustion characteristics of veneer specimens coated with four kinds of ammonium salts. Each veneer specimen was coated three times with 20 wt.% ammonium salt solutions at room temperature. After drying, the combustion characteristics of the specimens coated with chemicals, were investigated using the cone calorimeter (ISO 5660-1, 2). The specimens coated with monoammonium phosphate (MAPP) and, diammonium phosphate (DMPP) showed a 6.7% and, 10.0%, lower mean heat release rate ($HRR_{mean}$), respectively, than that of the uncoated specimen. On the other hand, the specimens coated with MAPP showed a 15.7% higher $CO_{peak}$ production rate and the specimens coated with DAPP showed by 8.2% lower rate than that of the uncoated specimen. The veneer coated with ammonium sulfate (AMSF) and DAPP showed a 9.6% and 33.3% lower the peak smoke production rate ($SPR_{peak}$) than that of the uncoated specimen. In addition, the time to the peak smoke extinction area ($SEA_{peak}$) was delayed by 38.4% in the specimens coated with DAPP than the uncoated specimen. Therefore, DAPP inhibited the combustion properties of the veneer and showed a tendency to reduce smoke production.