• 제목/요약/키워드: Heat room

검색결과 1,149건 처리시간 0.028초

Thermal analysis of two main CCS(cargo containment system) insultaion box by using experimental thermal properties (실험적 열적 물성치를 반영한 CCS 방열박스의 열전달 해석)

  • Choi, Sung-Woong;Roh, Jeong-U;Kim, Moo-Sun;Lee, Woo-Il
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • 제24권4호
    • /
    • pp.429-438
    • /
    • 2011
  • In this paper, experiment of thermal conductivity among thermal properties for CCS insulation material was carried out under the condition ranged from room temperature to cryogenic temperature. CCS insulation system should be sustained under cryogenic temperature($-163^{\circ}C$), and lots of investigations will be conducted how to block the heat to insulation material. CCS components which consist of various materials are especially the main interests, and how the temperature of the entire CCS along the location is should be investigated through these studies. With the experimental thermal properties, the steady state thermal analysis of the entire cargo system was conducted. When the LNG leaked through the insulation system with external impact, temperature distribution and thermal safety of secondary barrier, especially plywood and hull structure, was observed.

Development of the simulator for marine auxiliary boiler system (선박용 보조 보일러 시스템 시뮬레이터 개발)

  • Kim, Myoung-Hwan;So, Myung-Ok;Jung, Byung-Gun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권2호
    • /
    • pp.236-241
    • /
    • 2013
  • It requires long time and high cost for an apprentice engineer to reach the level of getting various experiences of engine space machinery and preparing for emergency situations. Therefore reducing the time and cost, several types of simulator that give the very similar surroundings to the ship engine room, relevant to STCW-95 are used for systematic education and training to get many experiences and good judgement in emergency. Since most simulators that are operated in Korea were imported from foreign countries, it is difficult to directly implant the amendments of STCW Convention and reflect International Maritime Organization (IMO) model courses. This study describe a development of marine auxiliary boiler simulator that makes the apprentice engineer easier to understand the relationship between equipments in steam system such as auxiliary boiler, exhaust gas boiler, and steam turbine.

Strength of Crack Healed-Specimen and Elastic Wave Characteristics of Al2O3/SiC Composite Ceramics (알루미나 탄화규소 복합세라믹스 균열치유재의 강도와 탄성파 특성)

  • Kim, Hae-Suk;Kim, Mi-Gyeong;Kim, Jin-Uk;An, Seok-Hwan;Nam, Gi-U
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제31권4호
    • /
    • pp.425-431
    • /
    • 2007
  • [ $Al_2O_3/SiC$ ]composite ceramics were sintered to evaluate the bending strength and elastic wave characteristics. The three-point bending test was carried out under room temperature. The elastic wave was detected by fracture wave detector. The crack healing behavior was investigated from 1373 K to 1723 K. The bending strength of $Al_2O_3/SiC$ composite by nanocomposite is higher than that of $Al_2O_3$ monolithic. Crack-healing behavior depended on an amount of additive powder $Y_2O_3$. In $Al_2O_3/SiC$ composite ceramics with 3 wt. % $Y_2O_3$ for additive powder, the bending strength at 1573 K is about 100% increase than that of the smooth specimens. From the result of wavelet analysis of elastic wave signal, the smooth specimen and heat treated specimen of $Al_2O_3$ monolithic and $Al_2O_3/SiC$ composite ceramics showed characteristics of frequency about 58 kHz. The strength of $Al_2O_3/SiC$ composite ceramics was a little higher than those of $Al_2O_3$ monolithic. The dominant frequencies were high with increasing of $Y_2O_3$ for additive powder. The dominant frequencies had direct connection with the bending strength.

Energy Performance Evaluation of a Double-skin Facade with a Venetian Blind in Residential Buildings (주거건물용 이중외피 시스템의 블라인드 조절에 따른 에너지 성능평가에 관한 연구)

  • Lee, So-Yeun;Kang, Jae-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • 제30권6호
    • /
    • pp.1-9
    • /
    • 2010
  • Apartment balcony has been remodeled since the government permitted remodeling in January 2006.But extended balcony has great impact on building heat gain and loss. Therefore It has problems such as increase of heating and cooling energy. So $\underline{t}echnical$ solutions about window solar gain in summer is an urgent matter. The Purpose of this study is to evaluate energy performance of a blind in a double-skin facade in residential buildings by using EnergyPlus program. The results show that slat angles of $90^{\circ}$ is best in energy performance if we do not consider daylight. Poorly daylighted living room needs electric light and it also causes high cooling load. On the other hand, the results show that the application of blinds controlled automatically is best for energy performance when we consider daylight. Blind slat angles of $50\sim60^{\circ}$ have best performance when blinds are controlled in this angle throughout the day on a clear day in August. Blind slat angles of $0\sim30^{\circ}$ have best performance when blinds $\underline{are\;controlled}$ in this angle throughout the day on a cloudy day (more than 7 of total sky cover) in August.

A Study on the Analysis of Heating and Cooling Load through Applying Window Film Insulation (열 차단 필름의 적용에 따른 냉난방 부하 분석에 관한 연구)

  • Kim, Seok-Hyun;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • 제33권6호
    • /
    • pp.47-53
    • /
    • 2013
  • In order to reduce the energy consumption of the building, much effort is being made. The problems are that excessive solar radiation in summer and the heat loss in winter by the increase of window area. To prevent this problems, government limited the window area ratio or the performance of windows in new buildings. In order to reduce energy consumption of the existing buildings, the window film insulation is spotlight because the window film insulation was simple to installation. This study confirmed the performance of the window film insulation and affect to heating & cooling load of buildings. The impact of the window film insulation coating was confirmed by experiment. And this study confirmed the annual heating & cooling load by simulation. As a results, the surface temperature of coated window was higher than the surface temperature of existing window. The window film insulation was increased surface temperature of window. And this study confirmed that the increased surface temperature was slightly affected the room air temperature through experiment of the insulation box. The results of the heating and cooling load by simulation, this study confirmed that the case of coated window film insulation decreased cooling load in summer and increased heating load in winter. Also the annual total heating & cooling load was increased a little in the case of coated the window film insulation.

Crystal structure of Mn-Co-Ni thermistor (Mn-Co-Ni 서미스터의 결정구조 분석)

  • Lee, Jung-Il;Mhin, Sungwook;Ryu, Jeong Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • 제25권5호
    • /
    • pp.225-229
    • /
    • 2015
  • This study was performed to investigate crystal structure of cubic spinel-type monophase oxide composed of the Mn-Co-Ni ternary system. Starting material was prepared by mixing Mn, Co, Ni oxides then evaporation to dryness. The XRD patterns were analyzed by in-situ XRD as increasing temperature from room temperature to $1400^{\circ}C$ in air atmosphere. The cubic spinel phase was existed in a temperature range from $900^{\circ}C$. However, separation of NiO phase was detected from $1300^{\circ}C$, which was the origin of deterioration in the crytallinity. The surface morphology of the manufactured NTC thermistors were analyzed by FE-SEM for comparison of good and bad samples.

Physiological Activities of Citrus Peel Extracts by Different Extraction Methods and Gamma Irradiation (추출방법과 감마선 조사에 따른 귤피 추출물 생리활성의 변화)

  • 강호진;조철훈;김덕진;서재수;변명우
    • Food Science and Preservation
    • /
    • 제10권3호
    • /
    • pp.388-393
    • /
    • 2003
  • Citrus peel extract was prepared using 70% ethanol solution by two extraction conditions (20$^{\circ}C$ for 72 hours and 85$^{\circ}C$ for 3 hours). The effect of gamma-irradiation on the changes of physiological activity also investigated at 0, 5, 10 and 20 kGy of absorbed doses. Color characteristics, DPPH radical scavenging, tyrosinase inhibition and nitrite scavenging activities of the extracts were measured at 41$^{\circ}C$ for 30 days. Color values were different by extraction methods at the initial stage, which heat-extracted sample had lower L$\^$*/ - but higher a$\^$*/ - and b$\^$*/ -values than those extracted at room temperature. Irradiation changed color of the extract lighter by increasing Hunter color L$\^$*/ - and a$\^$*/ -values. DPPH radical scavenging, tyrosinase inhibition and nitrite scavenging activities were not affected by either extraction methods or irradiation but significantly reduced by storage time. Therefore, when the cost-effective extraction methods is selected, the citrus peel extracts, which is a major byproduct in citrus processing, could be used as a functional material in various applications.

A Validation Study of Temperature Field Predicted by Computational Fire Model for Spray Fire in a Multi-Compartment (다중구획공간내 분무화재시 화재해석모델의 온도장 검증연구)

  • Kim, Sugn-Chan
    • Fire Science and Engineering
    • /
    • 제28권5호
    • /
    • pp.23-29
    • /
    • 2014
  • The present study has been conducted to investigate the validity of the computational fire model and the results predicted by BRANZFIRE zone model and FDS field model are compared with a real scale fire test with spray fire in a multi-compartment. The liquid spray fires fueled with toluene and methanol are used as the fire source and the quantitative measurement of heat release rate is performed in an isolated ISO-9705 compartment with a standard door opening. The temperature field predicted by FDS model showed good agreement with the measurement in the fire room and the corridor, and BRANZFIRE model also gave acceptable result in spite of its simplicity and roughness. The mean temperature predicted by FDS model corresponds with measurement within maximum discrepancy range of 25% and the overall mean value of FDS model matched well with experimental data less than 10%. This study can contribute to establish the limitation and application scope of computational fire model and provide reference data for applying to reliable fire risk assessment.

Cold Plasma Treatment Effects on the Physicochemical and Biodegradable Properties of a Corn Biomass-containing Polyester Film (옥수수 바이오매스를 함유한 폴리에스터 필름의 물리 화학적 특성과 생분해 특성에 대한 콜드 플라즈마 처리의 영향)

  • Song, Ah Young;Oh, Yoon Ah;Oh, Se Jun;Min, Sea Cheol
    • Korean Journal of Food Science and Technology
    • /
    • 제47권2호
    • /
    • pp.224-232
    • /
    • 2015
  • The effects of cold plasma (CP) treatments on the physicochemical and biodegradable properties of a corn biomass-containing polyester (CBPE) film were studied. The CBPE film was treated with CP generated by $N_2$, $O_2$, He, Ar, or dry air at 400-900 W and 667 Pa for 10-40 min. The glass transition temperature of the CBPE film ($-30.2--28.6^{\circ}C$) was not affected by the CP treatment, while the elastic modulus and water vapor permeability decreased (p<0.05). The ink printability was improved by the treatment and the improved printability was maintained during storage for 56 days at room temperature. Roughness of the film increased after treatments and the level of roughness appeared to increase during storage. Heat and microbial biodegradability of the CBPE film was improved by the air-CP treatment (p<0.05). These results have demonstrated the potential of applying CP treatments to improve the flexibility, printability, and biodegradability of CBPE films.

The Planning of Temporary Housing for Post Application of Mega Sports Facilities - Focused on the 2018 Winter Olympics - (메가스포츠시설의 사후 활용을 위한 임시주거 계획 - 2018평창동계올림픽을 중심으로 -)

  • Lee, Jong-Chan;Kang, Youn-Do;Kim, Byung-Sean
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.41-46
    • /
    • 2016
  • Purpose: This is a study on the planning of temporary housing for post application of Mega Sports facilities. The subject of the study is 2018 Pyeongchang Winter Olympics, which is to suggest building an alternative temporary housing using shipping containers(high cube), which solve the lack of accommodations and recycle temporary housing after Olympics, save money and be eco-friendly in Olympics. Method: This study includes this ; research on the a fact-finding survey about Mega sports facilities post application and demand survey on 2018 Pyeongchang Winter Olympics accomodations and an analysis about temporary housing plan. Furthermore we decided temporary housing building plan by analyzing residents' needs and traits of the housing etc. Through this, we made a schematic design for household units. Result: As a result, this study is a plan of making space, forms, and structure. The planned size is $38.4m^2$(L:12m, W:3.2m) except balcony, and indoor height is 2.5m. The space consists of entrance, bathroom, bedroom and living room with folding furniture system. Also there's a detailed floor plan of the ceiling, wall, and floor we drew up. The ceiling and wall consist of dampproof film, noncombustible board, fire proof urethane form, and color-designed sheet. The floor is composed of floor tile, cement mortar, light concrete(with heat coil), insulation, and dampproof film. Additionally, this study is a plan of interior dry wall with detail using modular construction method for work efficiency and quality improvement.