• Title/Summary/Keyword: Heat management system

Search Result 407, Processing Time 0.033 seconds

A Study on the Actual Status of Heat Transfer oils in Industries for Process Safety Management (공정안전관리 사업장의 열매체유 사용실태에 관한 연구)

  • Lee, Keun Won;Lee, Joo Yeob
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.33-39
    • /
    • 2014
  • Heat transfer oils are used in applications such as chemical plant heating systems, refinery heat exchange systems, certain gas processes, injection molding systems, and pulp and paper processing. These oils are extremely stable and resistant to thermal and oxidative degradation. In the event of a spill or accidental release of heat transfer oils, it can be ignited easily when there is an ignition source. This study discusses the status of safety management through the actual status of the heat transfer oils to prevent fire and explosion accidents in industries for process safety management. The actual status of the heat transfer oils in process system of industries surveyed by a questionnaire developed. The results of this study can be used to help establishment of safety management to prevent fire and explosion accidents, such as the management of heat transfer oils, safe operation and maintenance in heat transfer oil processes.

Numerical Simulation of a System Heat Pump Adopting an Integral Optimum Regulating Controller (적분형 최적 레귤레이터 적용 시스템 히트펌프 제어 시뮬레이션 연구)

  • Kim, Yongchan;Choi, Jong Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.398-405
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system that utilizes package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance, along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only an easy distribution control, allowing free combination of indoor units with different models and different capacities, but also wide applications to intelligent air conditioning. However, the control algorithms of the system heat pump are limited in the open literature, due to complicated operating conditions. In this paper, an inverter-driven system heat pump having two indoor units with electronic expansion valves (EEV) was simulated in the cooling mode. An integral optimum regulating controller employing the state space control method was also simulated, and applied to the system-heat pump system, to obtain efficient control of the MIMO (multi input multi output) system. The simulation model for the controller yielded satisfactory prediction results. The new control model can be successfully utilized as a basic tool in controller design.

Transient Performance of a System Heat Pump with the Variation of Compressor Speed and EEV Openings (시스템 히트펌프의 압축기 주파수 및 전자팽창밸브 개도 변화에 따른 과도성능 특성)

  • Lee, Sang-Hyeok;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.3
    • /
    • pp.11-18
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system utilizing package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only easy distribution control allowing free combination of indoor units with different models and different capacities, but also wide applications to an intelligent air conditioning. In this study, the transient performance of a system heat pump was analysed with the variation of compressor speed and EEV openings. The superheat was selected as a control parameter of the system, because the variation of it was consistent with each indoor unit capacity.

Development of Cooling System for Thermal Management and Water Balance in Fuel Cell Vehicle (연료전지 차량의 열 및 물 균형 유지를 위한 냉각 시스템 개발)

  • Kim, Seong-Kyun;Lee, Seung-Yong;Kim, Chi-Myung;Park, Yong-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.113-117
    • /
    • 2006
  • This paper Is for development of cooling module in order to maintain heat and water balance in fuel cell vehicle. Thermal management system for fuel cell is disadvantage because the temperature of coolant is lower than that of ICE and heat duty of radiator is higher. By CFD simulation, cool ing module was developed for water balance of system. Hot chamber test and hot area/high altitude test on cool ing module was completed.

  • PDF

A study on temperature characteristic of the gases supplied to SOFC system by utilizing the ship exhaust gas (선박 배기가스 활용에 따른 SOFC 시스템 공급가스의 온도특성에 관한 연구)

  • Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.822-828
    • /
    • 2013
  • Since the operating temperature of Solid Oxide Fuel Cell (SOFC) is high, the heat management of the gases supplied to fuel cell system is important. In this paper, the temperature characteristic of the gases supplied to the anode and the cathode of the fuel cell is studied in case of utilizing the waste heat contained in the ship exhaust gas as a heat source to heat up the fuel, gas and water supplied to a 500kW SOFC system for a ship power. For the fuel cell system proposed in this paper, the temperature of gases supplied to the anode and the cathode was the highest temperature at 963K when the exhaust gas of the fuel cell was utilized as the heat source for gases supplied to fuel cell system instead of utilizing the ship exhaust gas. In addition, the engine power did not effect on the temperature of gases supplied to the fuel cell stack.

Development of Heat Pump System for High Efficiency Engine Vehicle (고효율엔진 차량 히트펌프 시스템 개발)

  • Park, Byung-Duck;Won, Jong-Phil;Lee, Won-Suk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.1
    • /
    • pp.21-26
    • /
    • 2007
  • As DDI or GDI engine discharges very low heat due to its high thermal efficiency, the heat source is not enough for heating the passenger compartment in cold climate condition. To remedy the heating problem, the conventional HFC-134a automotive air-conditioning system has been attempted to run as a heat pump mode. Futhermore, an auxiliary electric heater of new type was equipped to the heat pump air-conditioning loop as a new approach. Hence, a proto-type heat pump air conditioner has been made and tested to investigate the feasibility of the HFC-134a automobile air-conditioning system that could be worked as a heat pump. The experiment results showed that the sufficient heating capacity could be obtained by adding a heat pump with an new electric type auxiliary heater into the conventional heat core in low temperature condition.

  • PDF

Study on the Performance Characteristics of the Thermosyphon Used for the Vehicle Operated at Low Temperature Conditions (저온작동 조건에서 자동차용 써모사이폰의 성능특성에 관한 연구)

  • Lim, Taek-Kyu;Lee, Ho-Seong;Won, Jong-Phil;Cho, Chung-Won;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.510-515
    • /
    • 2012
  • The objective of this study is to investigate low temperature performance characteristics of the thermosyphon with/without wick. Thermosyphons using water as the working fluid are tested with variations of wick, charge amount of the working fluid, outdoor temperature, and heat load for the evaporator section at a low temperature. As a result, the heat transfer of thermosyphon was optimized at the charge amount of 40% and increased with the rise of the outdoor temperatures.

Experimental Study on Heat Transfer Characteristics of Thermosyphon Using Nanofluids (나노유체를 이용한 써모사이폰의 열전달 성능 특성에 관한 실험적 연구)

  • Lee, Moo-Yeon;Cho, Chung-Won;Lee, Ho-Seong;Won, Jong-Phil;Lim, Taek-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.11
    • /
    • pp.1073-1079
    • /
    • 2012
  • This study aims to experimentally investigate the heat transfer characteristics of a thermosyphon using nanofluids. A thermosyphon with three individual pipes, which share the internal volume of the evaporator section, was designed, and its performance was tested for various charge amounts, input powers of the evaporator section's heater, and concentrations of working fluids. The optimized charge amount of the thermosyphon using distilled water was 30%, and the thermal resistance of the thermosyphon with $TiO_2$ nanofluid was 18.1% lower than that with Ag nanofluid. In addition, the heat transfer performance of the thermosyphon with $TiO_2-1%$ was optimized at an input power of 300 W at the evaporator section's heater and a charge amount of 30%.

Heat Exchangers for Gas Turbine Cycles and Thermal Management (롤스로이스 기술개발 동향)

  • Stieger, Rory
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.465-465
    • /
    • 2011
  • Rolls-Royce is a global company producing advanced power systems for use on land, at sea and in the air. In order to develop competitive products and services, Rolls-Royce invests in technology, infrastructure and capability with much of the research carried out in a global network of University Technology Centres, such as the UTC in Thermal management at Pusan National University. Heat exchangers and thermal management play a critical role in today's gas turbine engines, maintaining the fuel and oil temperatures within the correct operational range. Future products are likely to place an increased duty on the thermal management system and thus require advances in heat exchanger design, installation and manufacturing. Heat exchangers further have the potential to play a vital role in Advanced Cycle Gas Turbine products. The Intercooled and recuperated WR21 marine gas turbine engine recently entered service with the Royal Navy and is delivering very attractive fuel burn in service. The development of an advanced cycle aero-engine is a significantly greater challenge, requiring better understanding of compact and light weight heat exchanger surfaces, novel installations and ducting systems and may required novel manufacturing techniques to achieve the volume, weight and cost necessary to realise a viable advanced cycle gas turbine aero-engine.

  • PDF

A Study on the Cooling Performance Improvement of Pouch Battery Thermal Management System for Electric Vehicles (전기자동차 파우치형 배터리 열관리 시스템의 냉각성능 향상에 대한 연구)

  • Shin, Jeong-Hoon;Lee, Jun-Kyoung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.715-724
    • /
    • 2022
  • In many electric vehicles, large-capacity pouch-type lithium-ion battery packs are mainly used to increase the mileage on a single charge. The lithium ion battery should be operated within the temperature range of 25℃ to 40℃ because the battery performance can be rapidly deteriorated due to an increase in internal temperature. Battery thermal management system (BTMS) can give the suitable temperature conditions to battery by water cooling method. In this research, the heat transfer characteristics (the battery temperature distributions and the water flow characteristics) were analyzed by CFD method to investigate the thermal performance of the cooling plate with 4-pass water flow structure. Moreover, the effect of the presence of fins between the battery cell was identified. The fins made smooth temperature distributions between the battery cells due to the heat spreading and lower the average battery cells temperature.