• Title/Summary/Keyword: Heat island effect

Search Result 209, Processing Time 0.03 seconds

Urbanization and Urban Heat Island Analysis Using LANDSAT Imagery: Sejong City As a Case Study (LANDSAT 영상을 이용한 세종특별자치시의 도시화와 열섬현상 분석)

  • Kim, Mi-Kyeong;Kim, Sang-Pil;Kim, Nam-Hoon;Sohn, Hong-Gyoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.1033-1041
    • /
    • 2014
  • Rapid urbanization of Korea was an unprecedented example in the world and urban population increased significantly. As a result, unbalanced distribution of population is serious problem in Korea because approximately 50% of the population is concentrated in the capital area that is 10% of nation's territory, thereby occurring various urban problems including UHI. Hence, Sejong Special Autonomous City was inaugurated officially on 2 July 2012 in order to decentralize population of capital area and induce more balanced regional development. The Sejong City has been changed drastically over a period of years as developed practically since the late 2000's and is expected to have new problems of urbanization. The land cover change due to urbanization is the main cause of UHI that urban area is significantly warmer than its surrounding areas and UHI is not only affecting urban climate change but also natural environment. So the purpose of this research is to analyze level of urbanization and UHI effect and to provide the correlation analysis between Land Surface Temperature and spectral indices. To achieve this, satellite imagery from LANDSAT were used. NDVI, NDBI, and UI were calculated using red, near-infrared, mid-infrared ($0.63{\mu}m-1.75{\mu}m$) images and LST was retrieved utilizing thermal infrared ($10.4{\mu}m-12.5{\mu}m$) image. Based on each index and LST, Changes of NDVI, UI and UHI through TVI were analyzed in Sejong City. UHI effect increased around newly constructed multi-functional administrative city, the correlation between LST and NDVI was negative and UI was strong positive.

A Geospatial Evaluation of Potential Sea Effects on Observed Air Temperature (해안지대 기온에 미치는 바다효과의 공간분석)

  • Kim, Soo-Ock;Yun, Jin-I.;Chung, U-Ran;Hwang, Kyu-Hong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.217-224
    • /
    • 2010
  • This study was carried out to quantify potential effects of the surrounding ocean on the observed air temperature at coastal weather stations in the Korean Peninsula. Daily maximum and minimum temperature data for 2001-2009 were collected from 66 Korea Meteorological Administration (KMA) stations and the monthly averages were calculated for further analyses. Monthly data from 27 inland sites were used to generate a gridded temperature surface for the whole Peninsula based on an inverse distance weighting and the local temperature at the remaining 39 sites were estimated by recent techniques in geospatial climatology which are widely used in correction of small - scale climate controls like cold air drainage, urban heat island, topography as well as elevation. Deviations from the observed temperature were regarded as the 'apparent' sea effect and showed a quasi-logarithmic relationship with the distance of each site from the nearest coastline. Potential effects of the sea on daily temperature might exceed $6.0^{\circ}C$ cooling in summer and $6.5^{\circ}C$ warming in winter according to this relationship. We classified 25 sites within the 10 km distance from the nearest coastline into 'coastal sites' and the remaining 15 'fringe sites'. When the average deviations of the fringe sites ($0.5^{\circ}C$ for daily maximum and $1.0^{\circ}C$ for daily minimum temperature) were used as the 'noise' and subtracted from the 'apparent' sea effects of the coastal sites, maximum cooling effects of the sea were identified as $1.5^{\circ}C$ on the west coast and $3.0^{\circ}C$ on the east and the south coast in summer months. The warming effects of the sea in winter ranged from $1.0^{\circ}C$ on the west and $3.5^{\circ}C$ on the south and east coasts.

Effect on the Temperature in Forest Dominant Vegetation Change (산림 우점식생 변화가 온도에 미치는 영향)

  • An, Mi-Yeon;Hong, Suk-Hwan
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.1
    • /
    • pp.97-104
    • /
    • 2018
  • This study investigated the effect of forest type changes in Daegu, the hottest city in Korea, on the land surface temperature (LST). The LST change by forest type was analyzed by 2scene of Landsat TM image from 1990 to 2007. The land cover types were classified into 4 types; forest areas, urban areas, cultivated areas and other areas, and water areas. The forest areas were further classified into the coniferous tree areas and the broadleaf tree areas. The result of the statistical analysis of the LST change according to the forest type showed that the LST increased when the forest was changed to the urban area. The LST increased by about $0.6^{\circ}C$ when a broadleaf tree area was changed to an urban area and about $0.2^{\circ}C$ when a coniferous tree area was changed to an urban area. This was the temperature change as the result of the simple type change for 17 years. The temperature change was larger when considering both cases of the forest type being retained and changed. The LST increased by $2.3^{\circ}C$ more when the broadleaf tree areas were changed to the urban areas than when broadleaf trees were maintained. The LST increased by $1.9^{\circ}C$ more when the coniferous tree areas were changed to the urban areas than when the coniferous tree areas were maintained. The LST increased by $0.4^{\circ}C$ more when the broadleaf tree areas were destroyed than when the coniferous tree areas were destroyed. The results confirmed that the protection of broadleaf trees in urban forests was more effective for mitigating climate change.

An Observation Study of the Relationship of between the Urban and Architectural Form and Microclimate (도시·건축형태와 미기후의 관계에 대한 관찰 연구)

  • Lee, Gunwon;Jeong, Yunnam
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.11
    • /
    • pp.109-119
    • /
    • 2018
  • This study investigates the effect of urban and architectural forms on the microclimate in urban areas. It applies urban and architectural elements such as urban form and tissue and building form and characteristics as the main influences on the microclimate within urban area. Among the 23 Automated Weather Stations (AWS) installed within Seoul city by the Korea Meteorological Administration, 6 sites were selected for the analysis, based on their different urban and architectural characteristics, and actual measurements were conducted in August 2017 using individual AWS equipment. Also, the measurements of microclimate and urban and architectural elements within a 500m radius of the AWS measurement points were collected and analyzed. The result of the analysis shows that the microclimate elements, such as wind speed, solar radiation, and temperature, were affected by the direction of the streets, the width, depth, and height of the buildings, the topographic elevation and direction and the traffic volume. This study is expected to contribute to mitigating urban heat island effect and setting the foundation for sustainable cities through development of urban management methods and techniques including the relationship between built environment elements and microclimate.

An Analysis of the Effect of Reducing Temperature and Fine Dust in the Roadside Tree Planting Scenario (가로수 식재 시나리오에 따른 기온 및 미세먼지 저감 효과 분석)

  • Jeong-Hee EUM;Jin-Kyu MIN;Ju-Hyun PARK;Jeong-Min SON;Hong-Duck SOU;Jeong-Hak OH
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.2
    • /
    • pp.68-81
    • /
    • 2023
  • This study aims to establish a scenario based on the spacing and arrangement of the roadside trees to reduce heat waves and fine dust in cities that occurred during the urbanization process and to quantitatively analyze the degree of reduction. The ENVI-met 5.0.2v model, a micro-climate simulation program, was used to analyze the degree of improvement in the thermal environment and fine dust according to the roadside tree scenario. As a result of temperature analysis according to street tree spacing, the narrower the distance between roadside trees, the lower the temperature during the day as the number of planted trees increased, and a similar pattern was shown regardless of the distance between roadside trees in the morning and evening. In the case of fine dust emitted from the road, the concentration of fine dust increased slightly due to the increase in roadside trees, but the concentration of sidewalks where people walk increased slightly or there was no difference because of blocking fine dust on trees. The temperature according to the arrangement of street trees tended to decrease as the number of planted trees increased as the arrangement increased. However, not only the amount of trees but also the crown projected area was judged to have a significant impact on the temperature reduction because the temperature reduction was greater in the scenario of planting the same amount of trees and widening the interval of arrangement. In terms of the arrangement, the fine dust concentration showed a difference from the results according to the interval, suggesting that the fine dust concentration may change depending on the relationship between the main wind direction and the tree planting direction. By quantitatively analyzing the degree of thermal environment and fine dust improvement caused by roadside trees, this study is expected to promote policies and projects to improve the roadside environment efficiently, such as a basic plan for roadside trees and a project for wind corridor forests.

Metallurgical Study of Bronze Relics Excavated from Sanoesa Temple, Chongju (청주(淸州) 사뇌사지(思惱寺址) 출토 청동유물의 금속학적 조사)

  • Kwon, H.N.;Yu, H.S.;Ahn, B.C.
    • Journal of Conservation Science
    • /
    • v.9 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • In 1993, many bronze artifacts were excavated from the Sanoesa Temple(思惱寺), Chongju, Chungbuk. Twelve items were selected and chemically analyzed with AA Spectrometry and ICP-Atomic Emission Spectrometry. They were also observed under the optical microscopy and SEM. According to the results from chemical analysis, production method and use, these artifacts were classified into four groups: casting, wrought and welding products, and bells. Cast products, probably used for ritual, were alloy of 70% Cu, 10% Sn and 20% Pb. They showed ${\alpha}+{\beta}$ phase as a typical microstructure of casting. The ${\delta}$ phase was rarely observed due to the small amount of Sn. These artifacts included more lead than other alloys. They showed segregation like island-shape on the lead part. Wrought products used for daily too1s. were alloy of 80% Cu and 20% Sn. Since they were consist of ${\alpha}$ phase and martensite ${\beta}$ phase, it could be presumed that they were heat-treated. The production method could be identified from twinned grains in ${\alpha}$ phase. Lead was not included in because it had a bad effect to alloy. The bells were alloyed with 85% Cu, 10% Sn, 5% Pb or 90% Cu and 10% Sn. They show the dendrite structure because they were cast and alloyed with many tin. Weldinged were alloyed with 83% Cu, 12% Sn and 5% Pb. lt showed the fine dendrite structure because of fast cooling in air.

  • PDF

Estimation of C Storage and Annual $CO_2$ Uptake by Street Trees in Gyeonggi-do (경기도 도시가로수의 탄소저장량과 연간 이산화탄소 흡수량 산정)

  • Park, Eun-Jin;Kang, Kyu-Yi
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.5
    • /
    • pp.591-600
    • /
    • 2010
  • We estimated and compared C storages and annual $CO_2$ uptakes by 9 dominant tree species planted along the streets. DBH and age by tree species were measured in the sites selected considering the planting status and distributions of tree species, and biomass, C storage, growth rate, and annual $CO_2$ uptake were estimated for each species. As a result, L. tulipifera, M. glyptostroboides, P. occidentalis were classified into fast-growing group, P. serrulata, G. biloba, Z. serrata, S. japonica, A. palmatum showed intermediate growth rates, and P. densiflora was slow-growing. Average C storage per tree was 205kgC/tree and ranged from 518kgC/tree(L. tulipifera) to 41kgC/tree(P. densiflora). Average annual $CO_2$ uptake by urban street trees over their lifespan ranged from $7.6kgCO_2$/tree/y to $99.1kgCO_2$/tree/y and L. tulipifera was the greatest, followed by glyptostroboides and P. occidentalis, and P. densiflora was the lowest. Total annual $CO_2$ uptake by all street trees in Gyeonggi-do, estimated based on the annual $CO_2$ uptake by each species, was as small as approximately 0.67% of that by forest in Gyeonggi-do. However, urban trees are still important because forest area continues to decrease and urbanization occurs annually in Gyeonggi-do, and should be managed considering their multi-functional aspects, including mitigation of heat island effect and building energy saving(indirect $CO_2$ uptake).

Cost-effective assessment of filter media for treating stormwater runoff in LID facilities (비용 효율적 강우유출수 처리를 위한 LID시설의 여재 평가)

  • Lee, Soyoung;Choi, Jiyeon;Hong, Jungsun;Choi, Hyeseon;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.2
    • /
    • pp.194-200
    • /
    • 2016
  • The impervious surface rate increased by urbanization causes various problems on the environment such as water cycle distortion, heat island effect, and non-point pollutant discharges. The Low Impact Development (LID) techniques are significantly considered as an important tool for stormwater management in urban areas and development projects. The main mechanisms of LID technologies are hydrological and environmental pollution reduction among soils, media, microorganisms, and plants. Especially, the media provides important functions on permeability and retention rate of stormwater runoff in LID facilities. Therefore, this research was performed to assess the pollutant removal efficiency for different types of media such as zeolite, wood chip, bottom ash, and bio-ceramic. All media show high pollutant removal efficiency of more than 60% for particulate materials and heavy metals. Double layered media is more effective in reducing heavy metals by providing diverse sizes of micro-pores and macro-pores compared to the single layered media. The results recommend the use of different sizes of media application is more cost-effective in LID than a single size of media. Furthermore, soluble proportion of total heavy metal in the stormwater is an important component in proper media selection and arrangement.

Urbanization Effects on Reference Evapotranspiration (도시화에 따른 수문기후변화 II (도시화가 기준 증발산량에 미치는 영향))

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.7
    • /
    • pp.571-583
    • /
    • 2007
  • The effects of climatic changes owing to urbanization, geographical and topographical conditions on Penman-Monteith reference evapotranspiration, and energy and aerodynamic terms of Penman-Monteith reference evapotranspiration have been studied. In this study, 56 climatological stations including the Seoul metropolis in South Korea have been selected, and the area of study site was set at $314\;km^2$. The climatological station is centrally located In the study area with a 10 km radius. The geographical and topographical characteristics of these sites were examined using GIS analysis. Land use status of the study area was also examined to estimate the extent of urbanization. The study results indicated that the variation of reference evapotranspiration rate is closely related to urbanization in most climatological stations. The level of change in reference evapotranspiration was higher in areas with higher urbanization rates. The change in reference evapotranspiration appears to be caused by temperature rises following heat island phenomena due to urbanization, and by the decrease in humidity, wind speed and sunshine duration due to the Increase in residential areas in urban districts. Especially, the humidity decrease causes a significant decrease in evapotranspiration rate. The study results showed that climatic change due to urbanization and proximity to the coast had the greatest effect on reference evapotranspiration.

Analysis of Water Cycle Effect according to Application of LID Techniques (LID 기법 적용에 따른 물순환 효과분석)

  • Lee, Jungmin;Lee, Yun;Choi, Jongsoo
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.411-421
    • /
    • 2014
  • At present, the development in rainwater management approach is still insufficient due to the numerous adverse effects of urbanization. Storm water management is being developed to restore the natural state of water cycle undergoing several processes which were hindered such as infiltration and evapotranspiration. Low Impact Development (LID) was established in order to reduce the negative effects of urbanization to our environment. These developments can be used to respond to the effects of climate change such as heat island phenomenon. The effects of the development of new town in the district plan with application of LID facilities were studied and reported. Typically, LID facilities were applied in small scale development and were rarely used in large-scale development. Most of studies, however, did not assessment the effects of large-scale development projects with LID application to the natural water cycle. This study was conducted to simulate the urban hydrologic cycle simulation on Asan-Tangjeong in Korea. This study may be used in urban hydrologic cycle simulation and establishment of an urban water management plan in the future. Lastly, this study generated a model using the recently updated SWMM5 which determined the hydrologic cycle simulation after installation of LID facilities.