• 제목/요약/키워드: Heat fluid analysis

검색결과 1,011건 처리시간 0.034초

부력의 영향을 포함한 점탄성 유체의 열전달에 관한 수치해석 (Numerical Analysis on Heat Transfer of Viscoelastic Fluid including Buoyancy Effect)

  • 손창현;안성태;장재환
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.495-503
    • /
    • 2000
  • The present numerical study investigates flow characteristics and heat transfer enhancement of the viscoelastic non-Newtonian fluid in a 2:1 rectangular duct. The combined effect of temperature-dependent viscosity, buoyancy and secondary flow caused by second normal stress difference are all considered. The Reiner-Rivlin model is used as a viscoelastic fluid model to simulate the secondary flow and temperature-dependent viscosity model is adopted. Three types of thermal boundary conditions involving different combinations of heated walls and adiabatic walls are considered in this study. Calculated Nusselt numbers are in good agreement with experimental results in both the thermal developing and thermally developed regions. The heat transfer enhancement can be explained by the combined viscoelasticity-driven secondary flow, buoyancy-induced secondary flow and temperature-dependent viscosity.

3차 B-spline 함수를 이용한 열전도 및 유체문제의 해석 (Analysis for computing heat conduction and fluid problems using cubic B-spline function)

  • 김은필
    • 한국전산유체공학회지
    • /
    • 제3권2호
    • /
    • pp.1-8
    • /
    • 1998
  • We make use of cubic B-spline interpolation function in two cases: heat conduction and fluid flow problems. Cubic B-spline test function is employed because it is superior to approximation of linear and non-linear problems. We investigated the accuracy of the numerical formulation and focused on the position of the breakpoints within the computational domain. When the domain is divided by partitions of equal space, the results show poor accuracy. For the case of a heat conduction problem this partition can not reflect the temperature gradient which is rapidly changed near the wall. To correct the problem, we have more grid points near the wall or the region which has a rapid change of variables. When we applied the unequally spaced breakpoints, the results show high accuracy. Based on the comparison of the linear problem, we extended to the highly non-linear fluid flow problems.

  • PDF

스크린 도어와 계단 통로 사이 압력 강하량에 따른 지하철 승강장 내부 열유동 특성 (Heat and Fluid Flow Characteristics in Subway Station Platform with Consideration of Pressure Drop between Screen Doors and Stair Passages)

  • 윤정배;김석완
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.21-28
    • /
    • 2006
  • In the present study, the analysis on heat and fluid flow in subway station platform is carried out by considering the pressure drop between screen doors and stair passages. To investigate the effect on the characteristics of heat and fluid flow of pressure drop, Numerical simulation is applied. The present results show a better cooling condition, in the case of without pressure drop.

  • PDF

IGBT 스택용 10kW급 수냉각판 열유동 수치해석 (Numerical Thermo-Fluid Analysis to the Water Cooling Plate)

  • 유성열;목진성;조태식;김철주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1298-1302
    • /
    • 2011
  • The present study deals with the results of a thermo-fluid analysis applied to the cooling plate of the water cooling system developed for IGBT stacks, which was designed to keep the power semi-conductors from over heating problems. The cooling plate is to absorb a maximum quantity of 10kW from 4 IGBTs which are to be placed on both sides of the cooling plate, 2 IGBTs of them on each surface. For the analysis, Adina of CFD Program was used and an analysis was conducted to obtain the knowledges on heat and mass flow at both the plate and fluid flow inside. For the simulation, the operational conditions of a temperature difference of $15^{\circ}C$ for the working fluid and a uniform heat flux of about 92000 $W/m^2$ on the surface in contact with an IGBTs.

  • PDF

불응축가스량이 가변전열 히트파이프의 열수송 특성에 미치는 영향 (Influence of NCG Charging Mass on the Heat Transport Capacity of Variable Conductance Heat Pipe)

  • 서정세;박영식;정경택
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.320-327
    • /
    • 2006
  • Numerical analysis and experimental study are performed to investigate the effect of heat load and operating temperature on the thermal performance of several variable conductance heat pipe (VCHP) with screen meshed wick. The heat pipe is designed in 200 screen meshes, 500 mm length and 12.7 mm outer diameter tube of copper, water (4.8 g) is used as working fluid and nitrogen as non-condensible gas (NCG). Heat pipe used in this study has evaporator, condenser and adiabatic section, respectively. Analysis values and experimental data of wall temperature distribution along axial length are presented for heat transport capacity, condenser cooling water temperature change, degrees of an inclination angle and operating temperature. These analysis and experiment give the follow findings: For the same charging mass of working fluid, the operating temperature of heat pipe becomes to be high with the increasing of charging mass of NCG. When the heat flux at the evaporator section increases, the vapor pressure in the pipe rises and consequently compresses the NCG to the condenser end part and increases the active length of the condenser. From previous process, it is found out we can control the operating temperature effectively and also the analysis and experimental results are relatively coincided well.

CuO 나노유체를 적용한 판형열교환기 성능에 대한 수치해석적 연구 (Numerical Analysis on the Performance Improvement of Plate Heat Exchanger by Applying to CuO Nanofluid)

  • 함정균;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권1호
    • /
    • pp.9-16
    • /
    • 2020
  • In this study, a numerical study was conducted to evaluate the performance improvement when CuO nanofluid was used in the plate heat exchanger. As a result, the heat transfer amount is increased by 5.45% when 2 vol% CuO nanofluid is used. The influence on the CuO nanofluid on the performance of heat exchanger is decreased by increasing the flow rate of working fluid. In addition, the overall heat transfer coefficient using 2 vol% CuO nanofluid decreased compared to the base fluid. However, the pressure drop and the consumption of the pump power is increased as the concentration of CuO nanofluid increased because the increase of the viscosity. These are increased up to 15.4% compared to those of the base fluid. Moreover, the performance index of CuO nanofluid is decreased by 12.6% compared to that of the base fluid.

Safety Design of the Loop Heat Pipe (LHP) by the Hazard Analysis

  • Tanaka, Kiyoshi
    • International Journal of Safety
    • /
    • 제9권1호
    • /
    • pp.54-57
    • /
    • 2010
  • The LHP uses the capillary head instead of the mechanical pump to transfer the fluid. It does not have any moving parts and transfer the fluid by the capillary head between the vapor and liquid interface of the wick like a heat pipe (HP). Moreover, vapor and liquid flows in the same direction. It can reduce the loss of the pressure in the wick (very short wick in the evaporator) and can transfer large heat over long distance compared with HP. It is necessary that we do the hazard analysis that is a part of the safety design, for the benefit of eliminating and inhibit the hazard. In this paper, we describe the hazard analysis of LHP.

포화상태에 놓인 C-Type 액체수소 탱크의 슬로싱이 열 유속과 BOG에 미치는 변화의 수치적 분석 (Numerical Study of Heat Flux and BOG in C-Type Liquefied Hydrogen Tank under Sloshing Excitation at the Saturated State)

  • 이진호;황세윤;이성제;이장현
    • 한국전산구조공학회논문집
    • /
    • 제35권5호
    • /
    • pp.299-308
    • /
    • 2022
  • 본 논문은 슬로싱 상태에 놓인 포화 상태 액체수소탱크에서 열 유속 및 BOG(Boil-off gas)의 경향을 다루고 있다. 특히, 액체-기체간의 침투 및 혼합에 의한 열 교환에 관심을 두었다. 먼저, VOF(Volume of fluid)와 Eulerian 기반의 다상 유동모델로 모형 슬로싱 실험을 모사하여 압력을 예측하고 계측된 값과 비교하였다. 자유 수면 및 충격 압력 실험 결과와 해석 결과를 비교하였으며, 유체의 속도 예측에서 정확할 수 있음을 간접적으로 증명하였다. 그리고 2차원의 Type-C 원통형 수소탱크를 대상으로 다상열유동해석을 수행하였다. 이때 포화상태에 놓인 액체 및 기체수소를 가정하고, 해석을 통해 각 상간의 혼합에 의한 열 교환의 수준을 확인하고자 하였다. 단, 상간의 열 교환만을 관심으로 두고 있었으므로 질량전달 및 기화모델은 해석에서 제외하였다. 최종적으로 상의 혼합으로 인해 액체수소로 유입되는 열 유속의 기여도에 대하여 정리하였다. 또한 액체수소로 유입되는 열 유속과 집중 질량 기반의 간이식을 통해 BOG 발생량 및 경향을 예측하고 분석하였다.

아파트 단지내의 열섬효과가 대기오염물질 확산에 미치는 영향 해석을 위한 열유동장 수치모의 (A Numerical Simulation of Heat Flow Field for Heat Island Effect Analysis to Air Pollutants Dispersion in Apartment Complex)

  • 장은숙
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.577-582
    • /
    • 2005
  • Enormous apartment complexes in urban areas, temporary inversion state and heat island effect occur due to the strong sunshine and weak wind speeds which hinders the dispersion of air pollutants that are emitted from neighboring areas of apartment complexes. In this study, analysis were conducted by using the Fluent code based on the CFD(Computation Fluid Dynamics), including building layout, material, building height from the ground surface, the heat, analysis of flow field in the apartment complex. It was estimated that the temporal radiation inversion phenomenon during the daytime, which was caused by the weak wind speed and higher temperatures in the upper level, contributed to the stagnation of the air pollutants in the lower layer of the apartment complex.

하이브리드법을 이용한 열전냉각의 수치해석 연구 (Computer Simulation Study of the Thermoelectric Cooling by Hybrid Method)

  • 김남진;이재용;김종보
    • 태양에너지
    • /
    • 제20권1호
    • /
    • pp.97-108
    • /
    • 2000
  • The purpose of this study is to minimize the heat transfer surface area and cold fluid exit temperature of heat exchanger which applied to the refrigeration and air-conditioning system by utilizing the thermoelectric principle. Both uniform and non-uniform current distribution methods which applied to the analysis of the TE elements that incorporates heat exchanger were investigated. The non-uniform current distribution method had the better coefficient of performance and had the lower cold fluid exit temperature of the TE cooling system than the uniform current distribution method. It was found that if a TE cooling system incorporates a heat exchanger, a non-uniform current distribution should guarantee to the lowest cold fluid exit temperature. Also, the hybrid method (combination of the uniform and non-uniform current distribution method) is investigated to achieve the best results by combining the uniform and non-uniform current distributions. The results show that it can lower the cold fluid exit temperature and reduce the heat transfer surface area for the parallel flow arrangement if we apply the constant current in some entry region and the non-uniform increasing current in the direction of the cold fluid flow afterwards.

  • PDF