• 제목/요약/키워드: Heat exchanger effectiveness

검색결과 115건 처리시간 0.021초

확산접합 콤팩트 열교환기의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Diffusion Bonding Heat Exchangers)

  • 권오경;차동안;최미진;윤재호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2304-2309
    • /
    • 2008
  • The objectives of this paper are to study the characteristics of heat transfer and pressure drop of the micro channel heat exchangers using diffusion bonding technology. Four types of heat exchangers are designed and manufactured, which are straight type, long dot type, splited wavy type and straight double side type. Heat transfer and pressure drop performance of each heat exchangers are measured in various operating conditions, and compared each other. The results show that the $(j/f)^{1/3}$ performance of splited wavy type and long dot type increases about 10.3% and 6.1% at the Reynolds number 470 compared to that of straight type, respectively. On the other hand, $(j/f)^{1/3}$ performance of straight double side type decreases 19.7%.

  • PDF

습공기사이클 냉동시스템의 성능해석 (Performance Analysis of a Wet Air-Cycle Refrigeration System)

  • 원성필
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.504-511
    • /
    • 2014
  • The objective of this study is to theoretically analyze the performance of an open wet air-cycle refrigeration system, which nowadays is increasingly generating environmental concern. The temperature and relative humidity of the outside air are selected as the most important parameters. As the temperature and relative humidity of the outside air increase, the pressure ratio of the ACM compressor is determined to be nearly constant, the air temperature at the exit of the system increases, and the amount of condensed water, the cooling capacity, the COP, and the total entropy production rate increase overall. The effects of the effectiveness of the heat exchanger and the efficiency of the turbine on the performance are greater than that of the efficiency of the ACM compressor. Also, the performance of the wet air-cycle refrigeration system with two heat exchangers is enhanced, with a high COP and low total entropy production rate, compared to the system with a single heat exchanger.

난방운전 조건하에서 $CO_2$ 열펌프용 내부 열교환기의 열전달 특성에 대한 연구 (Study on Heat Transfer Characteristics of Internal Heat Exchanger for $CO_2$ Heat Pump under Heating Operating Condition)

  • 김대훈;이상재;최준영;이재헌;권영철
    • 에너지공학
    • /
    • 제17권2호
    • /
    • pp.116-123
    • /
    • 2008
  • 본 연구에서는 $CO_2$ 열펌프에 사용되는 내부 열교환기를 난방조건에서 운전할 경우, 실험 및 수치적 방법으로 열전달량, 효율, 압력강하 등을 관찰하였다. 4가지 종류의 내부 열교환기를 사용하였다. 수치 해석은 단면분할법과 하디크로스 방법을 이용하여 유량, 길이, 운전조건, 내부 열교환기 종류에 따른 영향을 분석하고 실험을 통해 확인하였다. 유량이 증가함에 따라 열전달량이 약 25% 향상되었다. 마이크로 채널이 동심관에 비해 열전달량이 약 100% 크게 나타났다. 길이가 증가함에 따라 열전달 증가율은 감소하였다. 압력강하는 고압측에 비해 저압측이 크게 나타났으며, 동심관에 비해 마이크로 채널이 약 100% 크게 나타났다. 고온입구조건이 증가할수록, 저온입구조건이 감소할수록 열전달량은 약 3% 증가하였다. $CO_2$의 열전달 계산의 정확성을 위해 $CO_2$의 특성과 관형상을 고려할 수 있는 열전달 상관식의 개발이 필요하다.

외부 수증기 연계 SOEC 시스템의 공급 스팀 온도 및 열교환기 유용도에 따른 시스템 BOP 및 운전 특성 분석 (Operation Characteristics According to Steam Temperature and Effectivenss of External Steam-Related SOEC System)

  • 김영상;이영덕;안국영;이동근;이상민;최은정
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.596-604
    • /
    • 2020
  • Solid oxide electrolysis cell (SOEC) attracts much attention because of its high energy efficiency among many water-electrolysis technologies. SOEC operates at temperatures above 700℃, so that the water required for water-electrolysis must be supplied in the form of steam. When the steam to be supplied to the SOEC is generated by the SOEC system itself, an enormous amount of latent heat is required to vaporize the water, so additional energy must be supplied to the SOEC system. On the other hand, if the steam can be supplied from the outside, a small amount of energy is required to raise the temperature of the low temperature steam, so that the SOEC system can be operated without additional energy supply from outside, which enables efficient water-electrolysis. In this study, we figure out the size of heat exchanger for various steam temperature and effectiveness of heat exchanger, and propose the energy efficiency of the system.

다양한 냉매를 적용한 내부열교환기 부착 2단 압축 냉동시스템의 성능 분석 (Performance Analysis of Two-stage Compression Refrigeration System with Internal Heat Exchanger Applied Various Refrigerants)

  • 윤정인;허성관;제재면;전민주;손창효;문정현
    • 동력기계공학회지
    • /
    • 제19권6호
    • /
    • pp.82-88
    • /
    • 2015
  • In this paper, cycle performance analysis of two-stage compression and one-stage expansion refrigeration system applied various refrigerants is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporation temperature, condensing temperature, mass flow rate ration into inter-cooler, effectiveness of internal heat exchanger. The main results were summarized as follows : The COP of two-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling, mass flow rate ration of inter-cooler, evaporation temperature, but decreases with the increasing condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and 1-stage expansion using substitute refrigerant have an effect on COP of this system. The COP of alternative refrigerants was higher than the COP of R22 in this study, although the COP of some mixed refrigerants were lower than COP of R22.

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

리큐퍼레이터를 고려한 50KW급 터보제너레이터 가스터빈 엔진의 성능해석 (Performance Analysis of a 50㎾ Turbo-Generator Gas Turbine Engine with a Recuperator)

  • 김수용;수다레프
    • 한국추진공학회지
    • /
    • 제3권2호
    • /
    • pp.48-55
    • /
    • 1999
  • 50㎾급 터보제너레이터 가스터빈 엔진에 리쿠퍼레이터가 부착되는 경우 성능 변화를 조사하였다. 리쿠퍼레이터는 군사 및 소형 자동차용 엔진에 경제적 연비와 배기가스 저감의 목적으로 많이 적용되어 왔다. 열역학적 관점에서 볼 때 재생사이클은 압축비 10이하 및 비교적 낮은 터빈 입구온도에서 사이클의 효율 상승에 기여하는 바가 큰 것으로 나타난다. 1축단순사이클 터보제너레이터 가스터빈 엔진에 리쿠퍼레이터를 부착하는 경우 리쿠퍼레이터 효율 $\varepsilon$ = 0.5에서 엔진의 효율은 상대적으로 약 30% 증가하는 것으로 나타났고 이때 열교환기내의 압력 손실은 5.2%로 설계하였다. 용이한 제작, 구조적 견고성, 최소의 누출 둥의 장점으로 튜브형의 열교환 시스템이 본 가스터빈 엔진에 적합한 것으로 판단되었다.

  • PDF

Performance analysis of the passive safety features of iPOWER under Fukushima-like accident conditions

  • Kang, Sang Hee;Lee, Sang Won;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.676-682
    • /
    • 2019
  • After the Fukushima Daiichi accident, there has been an increasing preference for passive safety features in the nuclear power industry. Some passive safety systems require limited active components to trigger subsequent passive operation. Under very serious accident conditions, passive safety features could be rendered inoperable or damaged. This study evaluates (i) the performance and effectiveness of the passive safety features of iPOWER (innovative Power Reactor), and (ii) whether a severe accident condition could be reached if the passive safety systems are damaged, namely the case of heat exchanger tube rupture. Analysis results show that the reactor coolant system remains in the hot shutdown condition without operator actions or electricity for over 72 h when the passive auxiliary feedwater systems (PAFSs) are operable without damage. However, heat exchanger tube rupture in the PAFS leads to core damage after about 18 h. Such results demonstrate that, to enhance the safety of iPOWER, maintaining the integrity of the PAFS is critical, and therefore additional protections for PAFS are necessary. To improve the reliability of iPOWER, additional battery sets are necessary for the passive safety systems using limited active components for accident mitigation under such extreme circumstances.

EGR Cooler 내부 형상에 따른 Fouling이 냉각 성능에 미치는 영향 (The Effect of Cooling Efficiency on Fouling by EGR Cooler Internal Shape)

  • 남연우;오광철;이천환;이춘범;이원남
    • 한국자동차공학회논문집
    • /
    • 제19권1호
    • /
    • pp.101-108
    • /
    • 2011
  • Understanding the exhaust gas recirculation (EGR) cooler fouling in diesel engine is important factor in the durability characteristic of a EGR system. We develope a test rig and PM feeder using carbon black to examine the effect of fouling on EGR cooler devices those were consisted of flat and shell & tube type. The EGR cooler fouling process is a complex interaction involving heat exchanger shape, boundary condition, constitutes, chemistry and operating mode. As the soot deposited to EGR cooler, these formed a thin deposit layer that was less heat exchange than the fresh status of tube enclosing the exhaust gas, resulting in lower heat exchange effectiveness in both type coolers. But these deposits caused different results in pressure drop, it is increased in flat type, but decreased in Shell & tube type of EGR cooler. A cause was estimated from a change of the flow structure and a decrease of contact area as the EGR cooler fouling.

LNG 냉열을 이용하는 동력사이클 열역학 해석 (Thermodynamic Analysis of Power Generation Cycle Utilizing LNG Cold Energy)

  • 최권일;장홍일
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권1호
    • /
    • pp.48-55
    • /
    • 1999
  • thermodynamic cycle analysis has been performed for the power generation systems to utilize the cold energy of liquefied natural gas (LNG). The power cycle used the air or water at room temperature as a heat source and the LNG at cryogenic temperature as a heat sink. Among manypossible configurations of the cycle. the open Rankine cycle. and the closed Brayton cycle, and the closed Rankine cycle are selected for the basic analysis because of their practical importance. The power output per unit mass of LNG has been analytically calculated for various design parameters such as the pressure ratio. the mass flow rate. the adiabatic efficiency. the heat exchanger effectiveness. or the working fluid. The optimal conditions for the parameters are presented to maximize the power output and the design considerations are discussed. It is concluded that the open Rankine cycle is the most recormmendable both in thermodynamic efficency and in practice.

  • PDF