• 제목/요약/키워드: Heat exchanger effectiveness

검색결과 115건 처리시간 0.024초

열교환망 자동합성을 위한 새로운 방법 (A new method for an automated synthesis of heat exchanger networks)

  • 이규황;김민석;이인범;고홍철
    • 제어로봇시스템학회논문지
    • /
    • 제4권2호
    • /
    • pp.256-263
    • /
    • 1998
  • Among process synthesis problems, the heat exchanger network (HEN) has been subjected to the most concentrated effort because this kind of problems was well defined for solving it and 20-30% energy savings could be realized in the present chemical processes. In this paper, we use an evolutionary approach for HEN synthesis because this approach can overcome the local optimum and combine some heuristic rules. The basic evolutionary approach is composed of three parts, that is, initialization step, growth step and mutation step, as in the simulated annealing and genetic algorithm. This algorithm uses the ecological rule that a better cell will live and worse cell should decompose after repeated generations. With this basic concept, a new procedure is developed and a more efficient method is proposed to generate initial solutions. Its effectiveness is shown using test examples.

  • PDF

병영시설의 태양열급탕시스템에 관한 연구 (A Study on the Solar Water Heating System in the Military Facilities)

  • 김두천;서진석
    • 대한설비공학회지:설비저널
    • /
    • 제11권4호
    • /
    • pp.6-18
    • /
    • 1982
  • The performance of two typical types of solar hot water heating system was tested in Seoul. Types of systems studied are single-tank internal external heat exchanger system and single-tank internal heat exchanger system. Comparing to experimental results, a transient system simulation program was made to analyze the performance of the selected system. The climate data, Standard Weather Year for Seoul, required for the simulation was provided. Computer simulations were used to estimate the effect of significant parameters upon system performance. The followings are obtained. 1. In the domestic solar water Heating system, the value $20-40kg/m^2\;h$ for flow rate through the collector is much better than the recommended value $72kg/m^2\;h$ in the solar heating system. 2. The effectiveness of collector heat exchanger and storage tank size are found to have only a small effect upon system performance. 3. The hot water draw pattern has a significant effect on system performance. A higher system efficiency achieved when draw-off occurred around noon than when it occurred around early morning. Using the above results, the reference solar hot water system which provides $300\ell$ of hot water per day, was selected as a guide for designer. And simplified graphical method was developed based on the modified f-chart method to determine required collector area. When the system design parameters of the proposed system differs from the reference system, required collector area can be calculated from area adjustment factors.

  • PDF

자동차용 에어컨의 마이크로채널 응축기의 수치적 모델 개발 (Numerical Model Development of a Microchannel Condenser for Mobile Air-Conditioning Systems)

  • 쉐흐리야 이샤크;나비드 울라;최준호;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.430-436
    • /
    • 2022
  • This paper presents the numerical model development of a microchannel heat exchanger in mobile air-conditioning and heat pump applications. The model has been developed based on the effectiveness-NTU method using a segment-by-segment modeling approach. State-of-art correlations are used for refrigerant- and air-side heat transfer coefficients and pressure drops. The calculated heat condenser capacities are in good agreement with experimental data, with an average difference of 1.86%. The current model can be used for microchannel condenser simulations under various operating conditions. It is anticipated to improve productivity in designing and optimizing microchannel heat exchangers with folded louver fin geometry.

지중 열교환기의 순환수에 의한 열응력 및 열전달 거동 분석 (Analysis of thermal stress and heat transfer due to circulating fluid in ground heat exchanger)

  • 길후정;이강자;이철호;최항석;최효범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.385-395
    • /
    • 2009
  • In this study, a series of numerical analysis has been accomplished on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) in a geothermal heat pump system (GHP) considering the circulating fluid, pipe, grout and soil formation. A finite element analysis program, ABAQUS, was employed to evaluate the temperature distribution on the cross section of the U-loop system involving HDPE pipe/grout/formation and to compare sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system. Especially, the latticed pipe is equipped with a thermal insulation zone in order to reduce thermal interference between the inflow pipe and the outflow pipe. Also, a thermal stress analysis was performed with the aid of ABAQUS. 3-D finite volume analysis program, FLUENT, was adapted to analyze a coupled system between fluid circulation in the pipe and heat transfer and simulate an operating process of the closed-loop vertical ground heat exchanger. In this analysis, the effect of the thermal properties of grout, rate of circulation pump, distance between the inflow pipe and the outflow pipe, and the effectiveness of the latticed HDPE pipe system are taken into account.

  • PDF

TRNSYS 기반 무창기공형 공기식 집열 시스템 부프로그램 개발에 관한 연구 (Study on Development of Subroutine based on TRNSYS for Unglazed Transpired Air Collector System)

  • 박준언;이의준;정모
    • 한국태양에너지학회 논문집
    • /
    • 제23권2호
    • /
    • pp.81-90
    • /
    • 2003
  • UTAC(unglazed transpired air collector) system has unique advantage for space heating and tempering ventilation air over the conventional collector system such as flat plate and vacuum collector. UTAC can improve radiative and convective loss due to nonglazed component and enhanced plate surface configuration. and heating energy and its equivalent green house emission performance can be improved from the use of this like collector in building application. The Option D Calibration simulation approach of IPMVP(International Performance Measurement and Verification Protocol) in ESCO businesses has been recommended to use of the calibrated computer modules like these Energy-10. DOE2.1E and TRNSYS(transient system simulation). This study is to develop subroutine type-203 of TRNSYS15.2 program and appraise thermal performance of UTAC. With newely addeded subroutine type-203. 1) Thermal performance of unglazed transpired collector could be possible based on dimensionless variables such as efficiency and heat exchanger effectiveness. and 2) Assessement of energy consists of solar useful and insulation saving for UTAC could be possible.

스털링 엔진용 재생 열교환기의 다공체 구조에 따른 성능 특성 (Performance Characteristics of a Regenerative Heat Exchanger Depending on Its Porous Structure)

  • 신명철;안준;강병하
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.415-421
    • /
    • 2012
  • Stirling engine is an external combustion engine, whose efficiency approaches that of Carnot engine with the help of a regenerator. The regenerator is a heat exchanger composed of porous medium, whose performance is dependent on the pore structure. Three types of pore structures are considered in the present study. They are wire screen, random wire and composite structure, i.e. a combination of wire screens with different hydraulic diameters. The porosity more highly affects the performance of a regenerator compared to the hydraulic diameter. The random wire can yield high effectiveness even at a high porosity. The composite mesh gives better performance when the hydraulic diameter decreases in the direction from hot side to cold side.

Fundamental Study on Jet Defrosting Method for Precooled Turbojet Engines(Effects of the Surface Temperature of Cooling Tubes)

  • Fukiba, Katsuyoshi;Sato, Tetsuya;Inoue, Shou;Ohkubo, Hidetoshi
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.182-186
    • /
    • 2008
  • Fundamental experiments with single row heat exchanger were conducted for the purpose of validating new defrosting method using jet impingement. The coolant temperature were varied from 83 to 250 K. We used the jet periodically, once in 50 second and the duration of the jet is 0.1 second. The effect of the coolant temperature in the effectiveness of the jet defrosting was investigated.

  • PDF

단프라시트를 적용한 간접식 증발냉각 장치의 냉각 성능 예측 (Prediction of Cooling Performance for Indirect Evaporative Cooling System Using Danpla Sheet)

  • 김명호;김병재
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.892-897
    • /
    • 2020
  • 본 연구에서는 간접식 증발냉각 장치의 냉각 성능을 예측하고 다양한 공기 유량 및 물 분무 유량 조건을 만족하는 성능 상관식을 제안한다. 기존의 플라스틱 열교환기는 공조 공간의 크기에 따라 금형을 새로 제작해야 하기 때문에 높은 효율에도 불구하고 잘 사용하지 않았다. 한편 단프라시트는 일반적으로 두께가 얇아 열교환이 우수하고, 특히 제작이 매우 용이하다. 따라서 열교환기를 단프라시트로 제작할 경우 금형이 별도로 필요하지 않아 열교환기 제작 비용을 크게 절감할 수 있다. 이에 본 연구에서는 단프라시트로 다채널 열교환기를 제작하여 간접식 증발냉각 장치를 제작하였다. 성능 실험장치는 열교환기, 물 분사 노즐, 터보홴, 항온조, 순환 펌프, 온도 센서, 습도 센서, 차압식 유량계 및 자료획득 장치로 구성하였다. 증발냉각 시 공기 유량이 증가하면 유용도가 감소하였고, 수공비에 따라 유용도 최적점이 존재하였다. 등온 조건에서 냉각 성능을 예측하는 상관식과 실내 환기 온도와 외기 상태를 반영하는 성능 상관식을 제안하였다. 상관식들의 냉각 성능 오차는 4 % 이내였다.

열전달을 고려한 냉동 사이클의 최적 설계조건 (Optimal Design Condition of Refrigeration Cycle with Heat Transfer Processes)

  • 김수연;정평석
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.225-229
    • /
    • 1990
  • 본 연구에서는 외부조건과 입력이 일정하게 주어져 있는 냉동 사이클에 대하 여 열교환기의 용량을 설계변수로 하여 출력과 효율이 최대가 되는 조건, 즉 최적 설 계조건을 살펴 보고자 한다. 아울러 이 조건과 엔트로피 생성 최소조건과의 관계와 비가역 사이클인 경우도 살펴보았다.

확산접합 콤팩트 열교환기의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Diffusion Bonding Heat Exchangers)

  • 권오경;차동안;윤재호
    • 대한기계학회논문집B
    • /
    • 제33권1호
    • /
    • pp.53-59
    • /
    • 2009
  • The objectives of this paper are to study the characteristics of heat transfer and pressure drop of the micro channel heat exchangers using diffusion bonding technology. Four types of heat exchangers are designed and manufactured, which are straight type, long dot type, splited wavy type and straight double side type. Heat transfer and pressure drop performance of each heat exchangers are measured in various operating conditions, and compared each other. The results show that the $(j/f)^{1/3}$ performance of splited wavy type and long dot type increases about 10.3% and 6.1% at the Reynolds number 470 compared to that of straight type, respectively. On the other hand, $(j/f)^{1/3}$ performance of straight double side type decreases 19.7%.