• Title/Summary/Keyword: Heat environment

Search Result 2,482, Processing Time 0.032 seconds

A Study on The Effect of Anthropogenic Heat Flux and Land-Use on Thermal Environment in Pusan (인공열과 land-use가 부산시의 열적 환경에 미치는 영향 연구)

  • 김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.4
    • /
    • pp.363-372
    • /
    • 2000
  • In order to overtake a quantitative analysis of effect of anthropogenic heat and different land-use on urban thermal environment numerical simulation of surface energy budget was carried out under typical summer synoptic condition. It is beneficial to understand surface temperature of complex urban surace. The different land-use types are classified of rice field farm fruit garden residential region forest water and swamp by using map scaled 1/25000 of Pusan metropolitan. The model predicts that maximum heat island intensity in the central part of Pusan is 7$^{\circ}C$ at 2000 LST in summertime. The surface temperature is propotional to the density of constructions. The effect of anthropogenic heat generation on surface temperature is the increase of 0.3$^{\circ}C$ at 1400LST in the central part of Pusan during summertime.

  • PDF

Evaluation of Thermal Environment Improvement Effect from Public Design Improvement Project on the Urban Street Space (도시가로공간의 공공디자인 개선사업에 따른 열환경 개선 효과 평가)

  • Baek, Sang-Hun;Shimizu, Aki;Kim, Hak-Yoon;Jung, Eung-Ho
    • Journal of Environmental Science International
    • /
    • v.20 no.9
    • /
    • pp.1105-1114
    • /
    • 2011
  • In this study, thermal environment improvements throughout public design improvement project on the urban street space were compared and evaluated. Thermo-Render 3.0, 3D-CAD based thermal environment simulation program, had been used for thermal environment improvement evaluations. Followings are the results. First, clayey blocks which have low heat transfer rate and cool island effect by trees and roof gardens brought cooling effects for buildings and surface of streets. Seconds, MRT values showed low levels because of low radiant mulching materials. Thirds, roof gardens contributed to reduce heat island effect since HIP levels were affected by decreasing heat storage effect of buildings from roof gardens. As a result, reducing heat storage effect throughout selecting and arranging proper materials which would not increase heat island potentials should be performed to improve heat island effects.

The Micro Heat Flux Sensor using Electroplated Copper layers (구리 도금층을 이용한 미세 열유속 센서)

  • 오석환;전재철;김무환;이승섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.7
    • /
    • pp.226-231
    • /
    • 2000
  • New types of the micro heat flux sensor are designed and fabricated using SU-8 and Cu electroplating. And then calibrated under convection environment. The thermal path was made by SU-8 structure and electroplated Cu layers. The bottom surface of the micro heat flux sensor receives the heat flux from the wall, Then the heat flows along the Cu layers and drains out to the environment with producing the temperature difference at the upper layer of Cu. By measuring this temperature difference, the heat flux from the wall can be obtained. The temperature difference is measured by thermopile which is composed of Ni-Cr pairs or Al-chromel pairs. The calibration is accomplished under convection environment because it is most frequent situation. The range of the sensitivity is 0.11~2.02$\mu$V/(㎽/$\textrm{cm}^2$) for the various heat flux and Reynolds numbers.

  • PDF

A Study on the Impact of an Improved Road Pavement Technology on the Thermal Structure of Atmospheric Boundary Layer (도로 포장 기술 개선에 따른 대기 경계층의 열 변화에 관한 연구)

  • Lee, Soon-Hwan;Kim, In-Soo;Kim, Hae-Dong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.551-561
    • /
    • 2008
  • In order to clarify the impact of anti-heat insulation pavement on the thermal structure of atmospheric boundary layer, field experiments and numerical simulations were carried out. Field experiment with various pavements were also conducted for 24 hours from 09LST 19 June 2007. And numerical experiment mainly focused on the impact of albedo variation, which is strongly associated with thermal characteristics of insulated pavement materials, on the temporal variation of planterly boundary layer. Numerical model used in this study is one dimension model with Planterly Boundary Layer developed by Oregon State University (OSUPBL). Because anti-heat insulation pavement material shows higher albedo value, not only maximum surface temperature but also maximum surface air temperature on anti-heat insulation pavement is lower than that on asphalt. The maximum value of surface temperature only reach on $49.5^{\circ}C$. As results of numerical simulations, surface sensible heat flux and the height of mixing layer are also influenced by the values of albedo. Therefore the characteristics of urban surface material and its impact on atmosphere should be clarified before the urban planning including improvement of urban heat environment and air quality.

A Study on the Mitigation Policies for Urban Heat Island (도시열섬 완화를 위한 제도개선)

  • Suh, Eung Chul
    • KIEAE Journal
    • /
    • v.7 no.2
    • /
    • pp.17-23
    • /
    • 2007
  • While heat island has been recognized as an unique environmental nuisance in cities, the phenomenon tends to be regarded as an inevitable side effect on urbanization. Recently the nature of the heat island has been disclosed and efforts for the remedy have been discussed in many ways. Some pioneering actions have been taken to mitigate the strength of the heat island's intensity in several countries. After studies for the heat island and speculations on current pilot policies of 3 different countries has been done, mitigation policies for heat island has been suggested as followings. 1. Preservation of natural topography is essential because latent energy consumption(evapotranspiration) from the site is the single most important factor to mitigate the energy surplus caused by urban heat island. 2. Because current national zoning ordinance or building law can not effectively control the site specific local environment, heat island policy should be established or employed at local level. 3. Incentives for the mitigation should be adopted on the process of implementation because environment is public concern. 4. Wind can easily dissipate energy surplus which is the major driving force for heat island. Therefore local wind, the direction and intensity should be sustained and sometimes facilitated fully through policies.

Effect of Cooling Water Temperature on Heat Transfer Characteristics of Water Impinging Jet (냉각수 온도에 따른 수분류 충돌제트의 열전달 특성 연구)

  • Lee, Jungho;Yu, Cheong-Hwan;Do, Kyu Hyung
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.5
    • /
    • pp.249-256
    • /
    • 2010
  • Water jet impingement cooling has been widely used in a various engineering applications; especially in cooling of hot steel plate of steelmaking processes and heat treatment in hot metals as an effective method of removing high heat flux. The effects of cooling water temperature on water jet impingement cooling are primarily investigated for hot steel plate cooling applications in this study. The local heat flux measurements are introduced by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are used to measure the heat flux distribution during water jet impingement cooling. The experiments are performed at fixed flow rate and fixed nozzle-to-target spacing. The results show that effects of cooling water temperature on the characteristics of jet impingement heat transfer are presented for five different water temperatures ranged from 5 to $45^{\circ}C$. The local heat flux curves and heat transfer coefficients are also provided with respect to different boiling regimes.

An Analysis on the Variation Trend of Urban Heat Island in Busan Area (2006-2010) (부산지역 도시 열섬의 변화경향 분석 (2006-2010))

  • Do, Woo-Gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.21 no.8
    • /
    • pp.953-963
    • /
    • 2012
  • The annual variations of the urban heat island in Busan is investigated using surface temperature data measured at 3 automatic weather stations(AWSs) for the 5 years period, 2006 to 2010. Similar to previous studies, the intensity of the urban heat island is calculated using the temperature difference between downtown(Busanjin, Dongnae) and suburb(Gijang). The maximum hourly mean urban heat island are $1.4^{\circ}C$ at Busanjin site, 2300LST and $1.6^{\circ}C$ at Dongnae site, 2100LST. It occurs more often at Dongnae than Busanjin. Also the maximum hourly mean urban heat island appears in November at both sites. The urban heat island in Busan is stronger in the nighttime than in the daytime and decreases with increasing wind speed, but it is least developed in summer. Also it partly causes the increasement of nighttime PM10 concentration.

An Experimental Study on Comparing Solar Heat Shading Performances in Accordance with the Type of Internal Blinds in the Summer (하절기 내측 블라인드의 유형별 일사차폐성능 비교 실측연구)

  • Park, Eun-Mi;Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.1-9
    • /
    • 2016
  • The purpose of this study was to compare heat shading performance of various blind types in summer. 4 types of blinds were employed and the results are summarized as follows: 1) There were significant differences in indoor thermal environment and heat shading performance between different heat shading devices, and functional blinds demonstrated relatively superior heat shading performance. 2) Indoor long wave radiation influx measures were lowest for the coating roll blind (Blind B), followed by the coating venetian blind (Blind C), the venetian blind (Blind A), the roll blind, and not having any blinds at all. 3) Such examination results carry implications to reduce cooling load and enhance the indoor environment.

Development and application of an assessment tool for outdoor thermal environment (옥외 온열환경 평가를 위한 복사 연성 CFD 해석기법의 개요)

  • Lim, Jong-Yeon;Chang, Hyun-Jae;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.45-55
    • /
    • 2009
  • Deterioration of the outdoor thermal environment in urban areas has become worse and worse due to the urbanization and overpopulation, etc. Most of existing researches about thermal environment are focused on the indoor environment in which the radiation heat exchange is relatively constant. However, the outdoor thermal environment is changed with time passages, because the thermal environment is highly effected by solar radiation. Thus, to simulate the outdoor thermal environment with accuracy, the solar radiation calculation should be considered, and the radiation heat exchange between building surface and ground surface should be calculated. The purpose of this study is to develop the simulator that can be possible to evaluate the outdoor thermal environment and pedestrian thermal comfort. In this paper, a new method which is coupled with convective heat transfer simulation and radiative heat transfer simulation will be proposed. And the coupled simulation method will be described through case study for outdoor thermal environment. From the results of simulation, the coupled simulation proposed in this study can assess the outdoor thermal environment with accuracy.

A Time Dependent Analysis of Thermal Environment in Beehouse

  • Lee, Suk-Gun;Li, Zhenhai;Choi, Kwang-Soo
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.11a
    • /
    • pp.20-26
    • /
    • 1997
  • The design or analysis of beehouse inside temperature environment based on steady heat transfer theory causes much deviation and theoretically it is impossible to control the inside temperature lower than the outside temperature under the condition that the bee produces heat and no cooling equipment is installed. But in practical use of beehouse, the inside temperature is somehow lower than the outside temperature because of the heat inertia of concrete floor. (omitted)

  • PDF