• Title/Summary/Keyword: Heat density

검색결과 1,955건 처리시간 0.036초

알루미늄 호일 부착 발포 폴리스티렌 단열재의 열전도율, 열방출시험 및 가스 유해성 시험 (Heat Transfer Coefficient, Heat Release and Gas Hazard Tests for Expanded Polystyrene Heat Insulating Materials with Aluminum Foil)

  • 공하성
    • 대한안전경영과학회지
    • /
    • 제20권4호
    • /
    • pp.15-19
    • /
    • 2018
  • The purpose of this study is to enhance heat insulation effect and to decrease fire hazard by attaching aluminum foil to expanded polystyrene, which is mainly used for insulating materials, to have fire retardant. The result of the test confirmed that the insulating materials, expanded polystyrene of $10kg/m^3$ and $14kg/m^3$ of density attached aluminum foil on both sides, showed 12%, 14% of improved heat transfer coefficient respectively compared to existing expanded polystyrene of the same density. Besides, they met all the standards for the testing of heat release and gas hazard. On the other hand, the one made of general expanded polystyrene could not meet the standards of the heat release test and the gas hazard test.

ANODE HEATING AND MELTING IN THE ARGON GTA

  • Terasaki, Hidenori;Tanaka, Manabu;Fujii, Hidetoshi;Ushio, Masao
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.746-751
    • /
    • 2002
  • In order to make clear the physical relation among the arc plasma, the anode heat transfer and the weld penetration, the results of experimental measurements of temperatures of arc plasma, the distributions of heat input and current on the anode and the weld penetration were presented The experimental results showed that the electron temperature above the anode and current and heat input density on the anode was dominated by the position of the cathode. Furthermore, it was showed that electron temperature of arc plasma was dominated by the cathode shape. These results were related with the results of the welded penetration measurements. As a result, it was showed that the electron temperature above the anode and current density distribution on the anode decided the heat input density distribution on the anode and that the heat input density on the anode remarkably dominated the size of the weld penetration in argon GTA welding process. Furthermore, it was suggested that the cathode played the important role in the determination of the weld penetration in argon GTA welding process.

  • PDF

마루판용 합판의 단판 구성요소에 따른 열전달 특성에 관한 연구 (A Study on Heat Transfer of Plywood for Wood Based Flooring by Veneer Composition)

  • 피덕원;최송규;강호양;강석구
    • 한국가구학회지
    • /
    • 제23권3호
    • /
    • pp.298-304
    • /
    • 2012
  • Since 1990's, a flooring based on plywood has gotten customers' demand. Costs of raw material and production increased because of changed environment of industry. Tropical timber such as Red Meranti (Shorea acuminate) used for raw material of the floor has been depleting beside countries in South Eastern Asia changed species of afforestation. As a result, it gets hard to secure good quality of raw material for plywood. Moreover plywood price is increased suddenly after earthquake in Japan. Eucalyptus (Eucalyptus globulus) in china has been using for raw material as a countermeasure of changed environment of industry. In this study, possibility of using flooring consisted of Eucalyptus veneer as a core layer was checked by heat transfer experiments. Flooring consisted of Red Meranti was used for comparison. Two factors which impact on heat transfer are a type of density gradient and density difference between Long-grain veneer and Short-grain veneer. Red Meranti samples are 'M' type of density gradient on the other hand Eucalyptus samples are 'W' type of density gradient.

  • PDF

최대밀도점 부근의 물 속에 잠겨있는 수직 등온 강선에 의한 자연대류 (Free Convection due to Vertical Isothermal Wires Immersed in Water near its Density Extremum)

  • 엄용균;유갑종
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.338-350
    • /
    • 1996
  • A numerical analysis is carried out to study the two-dimensional steady state natural convection from vertical wires immersed in cold pure water. The surface of the wire is $0^{\circ}C$ unifrom temperature. Results of the analysis are presented for free stream temperature from $0^{\circ}C$ to $25^{\circ}C$ and the aspect ratio N from $5.26{\times}10^{-3}$ to $1.0{\times}10^{-3}$. The effects of the density extremum and aspect ratio on the flow pattern and the heat transfer characteristics are discussed As the aspect ratio N becomes larger, in the range of $1.0^{\circ}C{\leq}T_{\infty}{\leq}4.4^{\circ}C$ and $6{^{\circ}C}{\leq}T_{\infty}{\leq}17^{\circ}C$, the effect of Pr number on the heat transfer is shown to be more significant than the aspect ratio. Investigating into the effect of the density extremum on the heat transfer from wires, the new heat transfer correlations are suggested with the relation of average Nu mumber vs. modified Ra number. Here, the coefficient values C of correlations are presented as the function of density extremum parameter $R^*$. The effects of the density extremum parameter are also discussed.

  • PDF

지료조성에 따른 종이의 사이징 특성 (The Influence of Paper Stock Type on Characteristics of Sizing)

  • 정상진;김봉용
    • 펄프종이기술
    • /
    • 제37권2호
    • /
    • pp.11-20
    • /
    • 2005
  • This study was carried out to investigate the influence of paper stock type and heat treatment on sizing effect. Various types of pulps were used to make handsheets sized internally with AKD(alkyl ketene dimer) and externally with CMC(carboxyl methyl cellulose). Most of the handsheets were treated with heat by dry oven $(100^{\circ}C,\;30min)$ to evaluate the effect of heat treatment on sizing development. Internal sizing development of newsprint was very bad, but the effect of heat treatment was much higher than those of NBKP, BCTMP. In case of surface sizing, newsprint was more effective compared to the other pulps. Considering above mentioned results, it seems that internal sizing slows down water into paper by molecular diffusion much more than capillary penetration, but surface sizing slows down capillary penetration. With regard to density, a higher thickness sheets showed high heat treatment effect on sizing, therefore it assumed that heat treatment effect on sizing had very close relationship with sheet density.

Ti-6Al-4V합금의 열처리가 내식성에 미치는 영향 (The Effect of Heat Treatment on the Corrosion-Resistance for Ti-6Al-4V Alloy)

  • 백신영;나은영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.453-459
    • /
    • 2003
  • In this study, the effect of heat treatment to the electrochemical polarization resistance for the Ti-6Al-4V alloy was measured. The solution heat treatments were carried out at $1066^{circ}E, 966^{\circ}$E$, followed by aging heat treated $550^{circ}E, 600^{circ}E, and 650^{circ}E$. The electrochemical polarization resistance behavior was measured by potentio-dynamic polarization in the 1N $HNO_3$ + 15ppm HF solution. The obtained results were as follows. 1. As solution heat temperature increased. the corrosion potential was increased, whereas passive current density and critical current density were decreased. 2. As aging heat temperature increased, the corrosion potential was almost constant, but passive current density was decreased 3. The results of composition test measured by EDS at grain boundary and near $\gamma'$ precipitates indicated that S, Cl. and Si which originated from base metal were segregated at the grain boundaries Al and Ti which were the main alloying element in $\gamma'$ were depleted at the $\gamma'$ precipitated. The depletion of Al and Ti in $\gamma'$ was caused to early breakdown of passive film.

BSCCO 2223선재의 임계전류밀도에 영향을 미치는 단계별 열처리의 효과 (The effect of step heat treatment in the critical current density of BSCCO 2223 tapes)

  • 박성창;유재무;고재웅;김영국;김철진
    • Progress in Superconductivity
    • /
    • 제4권1호
    • /
    • pp.90-93
    • /
    • 2002
  • The sintering process of BSCCO 2223 tapes is a complex process that is very sensitive to parameters, such as temperature, oxygen partial pressure, heating and cooling rate and holding time. During the first heat treatment, 2212 phase of precursor powder is partially transformed into 2223 phase and some residual secondary phases, such as $(Bi,Pb)_2$$Sr_2$CuO/sub y/(2201), $(Ca,Sr)_2$CuO/sub y/(2/1AEC), (Ca,Sr)/sub 14/Cu/sub 24/O/sub 41/(14/24 AEC) etc. The secondary phases are difficult to be removed from the BSCCO 2223 matrix on the heat treatment. These secondary phases degrade the critical current density. In order to minimize the amount and size of alkaline earth cuprate(AEC) particles step heat treatment is applied during the first heat treatment under the varying atmosphere. Experimental results showed that by adapting the step heat treatment process, the amount and particle size of the secondary phases in the final tapes are decreased. Consequently, the BSCCO 2223grain texture and Jc properties are improved.

  • PDF

경질 폴리우레탄폼의 착화성 및 열방출특성 연구 (A Study on Ignitability and Heat Release Rate Characteristics of Rigid Polyurethane Foam)

  • 공영건;이두형
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.117-123
    • /
    • 2003
  • 본 연구에서는 Setchkin 착화성시험장치와 산소소비원리를 이용한 콘칼로리미터를 사용하여 난연처리되지 않은 경질우레탄폼의 착화특성 및 열방출특성 및 플래쉬오버 가능성에 대하여 연구하였다. 연구결과 경질폴리우레탄폼의 유도발화온도(FIT)는 $383^{\circ}C$$390^{\circ}C$, 자연발화온도(SIT)는 $493^{\circ}C$$495^{\circ}C$로 나타났으며 자연발화온도가 유도발화온도에 비해 약 $100^{\circ}C$ 높게 나타났다. 콘칼로리미터실험에서는 착화시간은 heat flux의 크기가 증가할수록 빨라졌으며 동일한 heat flux 크기에서는 밀도가 작을수록 착화시간은 짧게 나타났다. 열방출율은 $50 ㎾\m^2$에서 가장 크게 나타났으며, 최대열방출율의 경우 heat flux의 크기와 밀도가 커질수록 증가하는 경향을 보였다. 착화시간과 열방출율의 관점에서 경질폴리우레탄폼의 화재성능은 가해진 heat flux의 크기와 밀도에 큰 영향을 받는 것으로 나타났으며, Petrella의 제안방법에 의해 플래쉬오버 가능성을 분류한 결과 플래쉬오버 가능성이 큰 것으로 분류되었다.

다관형 고밀도 순환유동층 열교환기의 열전달계수에 대한 예측모델 연구 (A Study on Prediction Model of Heat Transfer Coefficient in the Circulating Fluidized Bed Heat Exchanger with Multiple Vertical Tubes)

  • 박상일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.288-293
    • /
    • 2005
  • The pressure distribution and heat transfer coefficient were measured at room temperature in the high suspension density CFB heat exchanger with multiple vertical tubes and the effective density of CFB was determined. The theoretical model for predicting heat transfer coefficient was developed in this study. The model predictions were compared with the measured heat transfer coefficient to show relatively good agreement between them.

  • PDF

Development and Characterization of the Asphalt Binder with Low-heat and Crosslink Structured Additive

  • Eun Kyoung Lee;You Kyoung Kim
    • Elastomers and Composites
    • /
    • 제57권4호
    • /
    • pp.222-230
    • /
    • 2022
  • In this study, a low-heat additive with a crosslink structure was dispersed in asphalt to simultaneously lower the production temperature of, and to modify the asphalt binder. This low-heat additive was prepared by different feeding ratios of styrene-butadiene-styrene (SBS) and polyvinylchloride (PVC) as polymer modifiers, and ZnO as a crosslinking agent. In order to confirm the crosslinking density and compatibility of the crosslink structured low-heat additive with asphalt, surface free energy, swelling ratio, differential scanning calorimetry (DSC), and scanning electron microscope (SEM) parameters were carefully investigated to examine this relationship, and the role of the crosslink structured low-heat additive. In addition, by measuring the penetration and softening point of the asphalt binder, it was confirmed that it corresponds to PG 64-22. With increasing ZnO in the crosslink structured low-heat additive, the swelling ratio decreased, leading to an increase in crosslinking density. The crosslink structured low-heat additive and the asphalt binder were found to be compatible with each other by DSC and SEM analysis.