• Title/Summary/Keyword: Heat current

Search Result 2,148, Processing Time 0.026 seconds

Study on the Establishment of Threshold Criteria for Heat Health Watch Warning System in Korea; Part II: Improvement of Criteria (고온건강경보시스템 기준 설정에 관한 연구 ( II ) - 설정 기준 개선 -)

  • Jung, Woo-Sik;Park, Jong-Kil;Kim, Eun-Byul;Song, Jeong-Hui
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.781-796
    • /
    • 2009
  • The current standard level of Heat Health Watch Warning System consider both daily maximum temperature and daily maximum heat index(HI), but current standard could not consider daily maximum HI due to the difficulties in forecasting when we consider both daily maximum temperature and daily maximum HI and no considering HI because relative humidity could not observed for some regions. So, Newly established standard level of Heat Health Watch Warning System is based on daily maximum temperature exceeding $30^{\circ}C$ for two consecutive days or daily minimum temperature exceeding $25^{\circ}C$ and daily maximum temperature exceeding $30^{\circ}C$. These days are called "extreme heat days". On extreme heat days, the standard of extreme heat advisory is based on daily maximum temperature among exceeding $32.7^{\circ}C$ and not exceeding $34.8^{\circ}C$, and extreme heat warning is based on daily maximum temperature exceeding $34.8^{\circ}C$. ANOVA analysis was carried out using the data of Seoul Metropolitan City in 1994 to check the robustness of the new standard level of Heat Health Watch Warning System from this study, in particular for mortality variable. The results reveal that the new standard specifies excess mortality well, showing significance level of 0.05 in the difference of excess mortality for each phase.

Heat Balance during the Electrowinning of Neodymium Metal in Molten Salt (네오디뮴 금속의 전해 채취 중의 열수지)

  • Cho, Sung-Wook;Yu, Jeong-Hyun;Choi, Ho-Gil
    • Resources Recycling
    • /
    • v.31 no.3
    • /
    • pp.81-87
    • /
    • 2022
  • Energy consumption per unit weight of metal (kwh/kg of metal) is one of the most important economic indicators in the process of molten salt electrolysis. It is related to the heat loss of salt bath and the current efficiency of the process. The current efficiency is highly dependent on electrolysis temperature. On the other hand, the temperature of salt bath may increase significantly due to the difference (larger energy input than consumption) in heat balance at the beginning of electrolysis, which may cause different electrolysis temperature from an initially targeted value. This results in a bad effect on current efficiency. Therefore, it will be helpful to the reduction of energy consumption to compare the calculated and measured values of the temperature change of salt bath through the heat balance review at the early stage of electrolysis and to evaluate the energy loss to outside. In this study, based on the authors' experimental data, the heat balance was reviewed at the beginning of the electrolysis, and it was possible to evaluate the energy loss to the outside and the increase of the temperature of the salt bath quantitatively. Through such a method, heat loss reduction plan can be derived and current efficiency can be improved so that energy consumption can be reduced.

Design of HTS Current Lead for SMES Magnet (SMES 마그네트용 고온초전도 전류도입선 설계)

  • Jang, Hyeon-Man;O, Sang-Su;Jo, Jeon-Uk;Jo, Yeong-Sik;Ha, Hong-Su;Ha, Dong-U;Seong, Gi-Cheol;Gwon, Yeong-Gil;Ryu, Gang-Sik;Kim, Sang-Hyeon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.2
    • /
    • pp.6-10
    • /
    • 2000
  • 1.5 kA class HTS current leads for a SMES magnet, which are connected to a conventional vapor cooled copper leads, were designed. The HTS leads are composed of Bi-2223/Ag-Au tapes and a stainless stell tube. The estimated critical current of the lead is about 1.6 kA at 77.3 K and in a self magnetic field, and the heat input to the liquid helium from the cold end of the 35 cm lead is 0.4 W/lead. It has been made clear that the heat input decreases with increase of the lead length and decrease of the warm end temperature and Ag-Au/SC ratio.

  • PDF

DC Characteristics of AlGaN/GaN HFETs Using the Modeling of Piezoelectric and Thermal Effects (Piezoelectric효과와 열 효과 모델링을 고려한 AlGaN/GaN HFET의 DC 특성)

  • Park, Seung-Wook;Hwang, Woong-Joon;Shin, Moo-Whan
    • Korean Journal of Materials Research
    • /
    • v.13 no.12
    • /
    • pp.769-774
    • /
    • 2003
  • In this paper, we report on the DC characteristics of the AlGaN/GaN HFETs using physical models on piezoelectric and thermal effects. Employing the models was found to be essential for a realistic prediction of the DC current-voltage characteristics of the AlGaN/GaN HFETs. Though use of the implementation of the physical models, peak drain current, transconductance, pinch-off voltage, and most importantly, the negative slope in the current were accurately predicted. The importance of the heat sink effect was demonstrated by the comparison of the DC characteristics of AlGaN/GaN HFETs fabricated from different substrates including sapphire, Si and SiC. Highest peak current was achieved from the device with SiC by an effective suppression of heat sink effect.

Temperature Control of the Aluminum Plate with Pottier Module by PWM Current Control (PWM 전류제어와 펠티어 소자를 이용한 알루미늄 판의 온도 제어)

  • Pang Du-Yeol;Kwon Tae-Kyu;Lee Seong-Cheol
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.897-900
    • /
    • 2005
  • This paper presents temperature control of aluminum plate using Peltier module. As one of the thermoelectric effect, Peltier effect is heat pumping phenomena by electric energy. So if current is charged to Peltier module, it absorbs heat from low temperature side and emits heat to high temperature side. In this experiment, Peltier module is used to control the temperature of small aluminum plate with heating and cooling ability of Peltier module with current control and fan On/OFF control. And current control of Peltier module was accomplished by PWM method. As a results of experiments, it takes about 125sec to control temperature of aluminium plate between $30^{\circ}C\;and\;70^{\circ}C$ and about 70sec between $40^{\circ}C\;and\;60^{\circ}C$, in ambient temperature $29^{\circ}C$ while operating cooling fan only while cooling duration. Future aim is to realize more rapid temperature control and develop SMHA(special metal hydride actuator) by using Peltier module as a heating and cooling source.

  • PDF

A Comparison Study of Heat Loss Characteristics in Monofilament and Multifilament Superconducting Coils Driven with AC Currents (단일필라멘트와 다중필라멘트 초전도 코일의 교류 전류에 의한 발열 특성 비교 평가)

  • Hwang, S.M.;Kim, K.;Kang, C.S.;Lee, S.J.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.111-116
    • /
    • 2011
  • Since superconducting wires have no resistance, electromagnets based on the superconducting wires produce no resistive heating with DC current as long as the current does not exceed the critical current of the wire. However, unlike resistive wires, superconducting wires exhibit AC heat loss. Embedding fine superconducting filaments inside copper matrix can reduce this AC loss to an acceptable level and opens the way to AC-capable superconducting coils. Here, we introduce an easy and accurate method to measure AC heat loss from sample superconducting coils by measuring changes in the rate of gas helium outflow from the liquid helium dewar in which the sample coil is placed. This method provides accurate information on total heat loss of a superconducting coil without any size limit, as long as the coil can fit inside the liquid helium dewar. With this method, we have evaluated AC heat loss of two superconducting solenoids, a 180-turn solid NbTi wire with 0.127 mm diameter (NbTi coil) and a 100-turn filamented wire with 1.4 mm diameter where 7 NbTi filaments were embedded in a copper matrix with copper to NbTi ratio of 6.7:1 (NbTi-Cu coil). Both coils were wound on 15 mm-diameter G-10 epoxy tubes. The AC heat losses of the NbTi and NbTi-Cu coils were evaluated as $53{\pm}4.7\;{\mu}W/A^2Hzcm^3$ and $0.67{\pm}0.16\;{\mu}W/A^2Hzcm^3$, respectively.

Fabrication and Characteristics of HTS Field Winding of a 100 hp Synchronous Motor (100마력 동기전동기용 고온초전도 계자권선 제작과 특성)

  • Sohn Myung-Hwan;Baik Seung-Kyu;Lee Eon-Young;Kwon Young-Kil;Jo Young-Sik;Moon Tae-Sun;Kim Yeong-Chun;Kwon Woon-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.2
    • /
    • pp.88-93
    • /
    • 2005
  • To develop a 100 hp high temperature superconducting(HTS) motor with high efficiency first in Korea, we fabricated a HTS field winding and test. HTS field winding is composed of sixteen HTS race track shaped coils wound with stainless steel-reinforced Bi-2223 tape conductor by react and wind fabrication method. Nomex paper was used for electrical insulation. Each of four magnet pole assemblies was constructed with four double pancake sub-coils, mechanically stacked and electrically in series. Four magnet assemblies were fixed on an aluminum support structure to make effective heat transfer. The Critical current (Ic) was 41.5A at 77K and self field. However the lowest Ic value of sub-coils was 35A. Joule heat generated by each joints between sub-coils was lower than 1mW at 77K and 34A. And Joule heat generated by the joints between field coils was lower than 10mW at 77K and 34A. Joule heat of the whole field winding was 1W at 77K and 32A. And so, the lowest Ic value of sub-coils was more important than Joule heats generated by all joints. The operating current must be lower than the lowest Ic of all the sub-coils. In this paper, design, construction and testing of HTS field winding, Joule heat generated by the joints, and operating current were discussed.

A Study on the Characteristics Analysis of Strands Melted by Over Current (과전류에 의해 용단된 소선의 특성해석에 관한 연구)

  • Choi, Chung-Seog;Kim, Hyang-Kon;Kim, Dong-Ook
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.60-65
    • /
    • 2004
  • The PVC insulated flexible cords are used mainly as power supply cords of electric appliance. This electric wire is a stranded wire consisted of dozens of strands. In case stranded wires are disconnected by mechanical stress, it weakens electrically. Finally, the over current flows through stranded wires, and electrical fire occurs. In this study, we analyzed the melting properties of strands by over current, such as melting process, melting current and melting time. And we analyzed that quantity of heat for melting, a cross sectional structure, and surface structure by optical microscope and SEM. As analysis results, melting time decreased as melting current increased. And quantity of heat for melting was low, too. From the cross sectional structure of melted wire, when a melting current low and melting time long, it was found that the dendrite structure grew. However, the dendrite structure is hard to grow because growing time is not enough when a melting current high and melting time short.