• Title/Summary/Keyword: Heat current

Search Result 2,148, Processing Time 0.027 seconds

The Analysis of Normal zone Propagation Velocity with Transient Heat transfer Effect in Superconducting Coil (초전도 코일에서 과도 열전달 효과를 고려한 상전도영역 전파속도 해석)

  • Suh, Yong-Sug;Lee, Sang-Jin;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.653-655
    • /
    • 1992
  • Longitudinal and transverse normal zone propagation in the superconducting coil are analyzed and propagation velocity is derived from the heat balance equations in the propagating boundary region. Transverse velocity is nearly $10^{-2}$ order of longitudinal velocity. Propagation velocity ie linearly proportional to the transport current. Increasing lamp current speeds up longitudinal velocity by 0.279 m/s under the applied field of 2T. Transient heat transfer has a significant effect on normal zone propagation velocity and it decreases longitudinal velocity by 4.2 m/s under the applied field of 2T as being compared to steady-state heat transfer.

  • PDF

Analysis of Temperature Distribution in EHV GIS Three-Phase Busbar Using Analytic Technique (해석적 기법을 이용한 초고압 GIS용 삼상모선의 온도분포 해석)

  • Hahn, Sung-Chin;Kim, Joong-Kyoung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.4
    • /
    • pp.196-202
    • /
    • 2006
  • This paper presents a new magneto-thermal finite element analysis for predicting the temperature rise of the EHV GIS busbar. Joule's heat due to current flowing in the main conductor and the heat due to the induced eddy current in the tank are calculated by the magnetic field analysis. And these heats are used as the input data to predict the temperature rise for the thermal analysis. However, it is not easy to apply the heat-transfer coefficients on the boundaries for the thermal analysis. In this paper, the heat-transfer coefficients on the boundaries are analytically calculated by applying the Nusselt number considering material constant and model geometry for the natural convection. The temperature distribution in the busbar by coupled magneto-thermal finite element analysis shows good agreement with the experimental data.

Heat Transfer Simulation and Temperature Measurement for Heat Input Control in Orbital Welding (오비탈 용접에서 입열량 제어를 위한 열전도 시뮬레이션 및 온도측정)

  • 김기정;김진우;강윤배;조상명
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.155-158
    • /
    • 2003
  • Orbital GTA welding is used in the pressure pipe line of auto-mobile, LNG and plant piping. To weld the pipe line safely, to some extent, the back bead must be formed in the root pass. In the plate welding the back bead can be observed, but in the pipe welding, the back bead can not be observed directly. In the welding around circumference, the parameters such as gravity, surface tension and arc force are different at each position. And then D/B for welding condition at each position are required. We also studied about the setting of the optimum orbital welding condition by controlling heat input.

  • PDF

The effect of heat treatment mass flow on superconducting property of Bi-2223/Ag Tapes. (열처리 가스유량에 따른 Bi-2223/Ag 초전도 테이프의 특성에 미치는 영향)

  • 양주생;하동우;이동훈;최정규;황선역;오상수;김상철;김명호
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.96-98
    • /
    • 2003
  • Many of research efforts have been focused on the improvement of critical current density Jc of silver-sheathed Bi-2223 tapes for practical applications of material. Bi-2223 superconducting wires with 55 filaments were fabricated by stacking, drawing process with different heat-treatment histories. After rolling process, Bi-2223 tapes were heat-treatment at 780~826$^{\circ}C$ with variable mass flow rate of mixed gas. In this study, the effect of changes in the variable mass flow rate of mixed gas during the heat treatment of Bi-2223/Ag tapes has been investigated. Distinct differences were observed in the Bi-2223 phase and critical current as flow rate of mixed gas. We could achieve proper conditions of mass flow rate of mixed gas for Ag-alloy clad Bi-2223 superconducting tapes.

  • PDF

Temperature Rise Prediction of Busbar of EHV GIS Considering Variation of Heat-Transfer Coefficient (열전달 계수의 변화를 고려한 초고압 GIS 모선의 온도 상승 예측)

  • Kim, Hyeon-Hun;Han, Seong-Jin;Ju, Su-Won;Jeong, Jin-Gyo;Lee, Byeong-Yun;Park, Gyeong-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.313-319
    • /
    • 2000
  • In order to design the current carrying conductor for GIS, it is important to predict temperature-rise when rated current flows in the bus bar. However, it is not easy to apply the correct heat transfer coefficient on the boundary between different material for the thermal analysis. In this paper, the heat transfer coefficient which depends on parameters such like material constant, model geometry as well as ambient temperature, was calculated by analytic method. The calculated coefficient is used for the temperature rise prediction by F.E.M. The results show good agreement with experimental data.

  • PDF

The Tunneling Effect at Semiconductor Interfaces by Hall Measurement (홀측정을 이용한 ZTO 반도체 박막계면에서의 터널링 효과)

  • Oh, Teresa
    • Korean Journal of Materials Research
    • /
    • v.29 no.7
    • /
    • pp.408-411
    • /
    • 2019
  • ZTO/n-Si thin film is produced to investigate tunneling phenomena by interface characteristics by the depletion layer. For diversity of the depletion layer, the thin film of ZTO is heat treated after deposition, and the gpolarization is found to change depending on the heat treatment temperature and capacitance. The higher the heat treatment temperature is, the higher the capacitance is, because more charges are formed, the highest at $150^{\circ}C$. The capacitance decreases at $200^{\circ}C$ ZTO heat treated at $150^{\circ}C$ shows tunneling phenomena, with low non-resistance and reduced charge concentration. When the carrier concentration is low and the resistance is low, the depletion layer has an increased potential barrier, which results in a tunneling phenomenon, which results in an increase in current. However, the ZTO thin film with high charge or high resistance shows a Schottky junction feature. The reason for the great capacitance increase is the increased current due to tunneling in the depletion layer.

Flow and Heat Transfer Characteristics due to Staggered Arrangement of Heat Pipes in Channels with Heat Pipes and Fins (휜-히트파이프로 구성된 채널에서 히트파이프의 엇갈림배열에 따른 유동 및 열전달 특성)

  • 김성훈;진윤근;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.871-879
    • /
    • 2002
  • The characteristics of flow and heat transfer in the heat exchanger of heat pipes with fins have been studied numerically for cooling enhancement of electronic components of KTX (Korea Train eXpress). Numerical analysis and methodology have been conformed by comparing the experimental results for inlined array of heat pipes. The staggered arrangement of heat pipes has been proposed in order to achieve heat transfer enhancement. As results, the geometry change to the staggered array is conformed to increase the heat transfer of the system accompanied by an increase of pressure drop. The current results of friction factor and Colburn j factor are presented in terms of Reynolds number and staggered distance, and are expected to use for design and manufacture of such a system.

Heat transfer enhancement in gas tungsten arc welding using azimuthal magnetic fields generated by external current

  • Kim, Yiseul;Lee, Jaewook;Liu, Xiaolong;Lee, Boyoung;Chang, Yunlong
    • Coupled systems mechanics
    • /
    • v.6 no.2
    • /
    • pp.113-125
    • /
    • 2017
  • This paper proposes the idea to enhance the heat transfer in Gas Tungsten Arc Welding (GTAW) by using the azimuthal magnetic field. The azimuthal magnetic field generated by the external currents makes the Lorentz force stronger, and consequently improves the heat transfer by the faster flow movement. The enhanced heat transfer might improve the welding performance by increasing the temperature at the workpiece. To validate the proposed idea, a two-dimensional axi-symmetric model of GTAW is built, and the multiphysics simulation of GTAW is carried out. As the analysis result, the distributions of electric current, electromagnetic fields, arc flow velocity, and temperature are investigated. Then, the proposed idea for heat transfer enhancement is validated by comparing the Lorentz force, flow velocity, and temperature distribution with and without azimuthal magnetic fields.

Polarization Characteristics of Heat-treated Ni-based Self-flux Alloy Coating in Alkaline Solution (후열처리한 니켈기 자융성 합금 코팅의 알칼리 용액에서의 분극특성)

  • Kim, Tea-Yong;Kim, Jea-Dong;Kim, Yeong-Sik
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2014
  • The purpose of this paper is to investigate polarization characteristics of heat-treated Ni-based self-flux alloy coating in alkaline solution. Ni-based self-flux alloy powder was sprayed to a steel substrate using flame spray process, and heat treatments were performed in a vacuum furnace at $800^{\circ}C$, $900^{\circ}C$, $1000^{\circ}C$ and $1100^{\circ}C$. After heat treatments, corrosion tests were carried out using potentiostat/galvanostat at solution with pH 8 and pH 13. Corrosion potential(Ecorr) and corrosion current density(Icorr) could be analyzed from polarization curve. Anticorrosive effect of heat-treated coating at solution with pH 8 was relatively greater than at solution with pH 13. Heat-treated coating at $1100^{\circ}C$ showed the greatest anti-corrosion characteristics in alkaline solution.

Thermal diffusion experiment of impulsive heat in subcooled liquid nitrogen (과냉 액체질소 내에서 순간적 열확산 실험)

  • Choi, J.H.;Ha, J.C.;Byun, J.J.;Chang, H.M.;Kim, H.M.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.65-70
    • /
    • 2006
  • Transient heat transfer caused by an impulsive heating in subcooled liquid nitrogen is investigated experimentally. This study is part of out ongoing efforts directed to a stable cryogenic cooling system lot superconducting fault current limiters (SFCL). A thin heater attached by epoxy on one surface of a GFRP plate is immersed in liquid-nitrogen bath at temperatures between 77 K and 55 K. A strong heat flux up to $150W/cm^2$ is generated lot 100 ms, and the temperature of the heater sulfate is measured as a function of time. The behavior of bubbles on the heating surface can be explained by comparing the measured temperature history for vertical and two horizontal (up and down) orientations. It is concluded that the subcooling of liquid nitrogen below 70 K is very effective in suppressing bubbles, resulting in better thermal protection and faster recovery from an impulsive heat.