• 제목/요약/키워드: Heat and brine discharge

검색결과 2건 처리시간 0.016초

소형실험태양(小型實驗太陽)연못에서 열저장층(熱貯藏層)의 두께에 관(關)한 실험적(實驗的) 연구(硏究) (Experimental Study on Thicknesss of Heat Storage Zone in Small Solar Pond)

  • 박이동;서지원
    • 태양에너지
    • /
    • 제7권2호
    • /
    • pp.22-29
    • /
    • 1987
  • This paper dealed with thickness variation of bottom heat sotrage zone due to salinity and flow rate of extration hot brine in small test solar pond (0.5m wide, 0.5m high, 1.0m long). Testing apparatus and situation were follows: 7.1 cm of height of suction diffuser and 1.8cm of height of discharge diffuser above the test pond respectively, 0.3cm of slot size of suction diffuser, 1.0cm of slot size of discharge diffuser, 47cm of length of the slot; heating of hot water ($75^{\circ}C$) through separated hot water tank, discharge of the brine into storage zone through discharge diffuser, the extration of the brine through suction diffuser, circulation of the extracted brine through a heat exchanger (cooler). Following results were obtained through the experiments. 1. In small test solar pond, the typical three zone which showed up in real solar pond were established. 2. Richardson Number was used more effectively to confirm hydrodynamic stability of the stratified flow. 3. The thickness of non convective layer had a great effect on the heat storage of the bottom convective layer, then the temperature of bottom convective layer had a relation to that of upper convective layer. 4. Optimum operating condition in the test pond was on 10%-15% of salt concentration and $0.05m^3/hr$ of flow rate of extraction hot brine. 5. Following thickness of 3 zones were available to obtain under optimum operation condition: o bottom storage zone: $30%{\pm}10%$ of total pond depth o non-convective zone: $40%{\pm}10%$ of total pond depth o Upper surface zone: $20%{\pm}10%$ of total pond depth.

  • PDF

온배수 및 염배수의 근역혼합특성 분석을 통한 방류시스템의 최적설계 (Optimum Design of Outfall System by Analyzing Mixing Characteristics of Heat and Brine Discharge at Near Field Region)

  • 남기대;이중우;김강민;김기담;김필성
    • 한국항해항만학회지
    • /
    • 제32권8호
    • /
    • pp.637-643
    • /
    • 2008
  • 해양방류시스템을 계획할 때 우선목표는 방류수의 초기희석을 극대화하는 것이다. 이를 효과적으로 달성하기 위해서는 방류수와 주변수의 혼합현상, 특히 초기혼합영역인 근역에 대한 특성분석이 선행되어야 한다. 최근까지 최적의 방류시스템(outfall system) 구현을 위하여 근역(NFR)에서의 온배수 방류에 관한 많은 연구가 이루어지고 있지만 온배수(heat discharge)와 염배수(brine discharge)를 동시에 방류할 경우를 고려한 성과물을 찾기는 어려운 실정이다. 이에 본 연구에서는 온수와 염수를 동시에 고려한 방류시스템의 최적설계를 위한 기초자료를 제공하기 위하여 방류수의 거동양상 특히, 근역에서의 혼합성을 분석하였다. 수치실험은 표면방류, 단일확산관 방류, 다공확산관 방류를 해당 해역의 법적 수질기준에 부합하는지 여부를 주로 평가하였다. 그 결과 표면방류와 단일확산관 방류는 방류형식이 부적절하였고, 다공확산관의 경우도 기하학적인 형상에 따라 결과가 조금 상이하였다.