• 제목/요약/키워드: Heat and Mass Transfer

검색결과 1,283건 처리시간 0.026초

Thermal Performance of a Finned-tube Heat Exchanger used in Condensing Gas Boiler

  • Kang, Hie-Chan;Lim, Bok-Bin;Lee, Jung-Man;Kim, Moo-Han
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권2호
    • /
    • pp.61-67
    • /
    • 2009
  • In the present study, an experiment was conducted to investigate the heat and mass transfer performance of heat exchangers used in the condensing gas boiler. Two types of spiral circular fin-tube heat exchangers and a plain tube were tested in the flue gas of propane and dry air. Heat and mass transfer coefficients were measured and compared with the previous correlations. The experimental data for the sensible heat transfer of the plain tube reasonably agreed with the previous correlations for dry air and flue gas. However, the mass transfer coefficient of the plain tube was greater than the previous correlations. The pH, $NO_x$, and $SO_x$ data of condensate were provided.

Flow Boiling Heat Transfer of R-22 in a Flat Extruded Aluminum Multi-Port Tube

  • Kim Nae-Hyun;Sim Yang-Sup;Min Chang-Keun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권3호
    • /
    • pp.148-157
    • /
    • 2004
  • Convective boiling heat transfer coefficients of R-22 were obtained in a flat extruded aluminum tube with $D_h=1.41mm$. The test range covered mass flux from 200 to $600kg/m^{2}s$, heat flux from 5 to $15kW/m^2$ and saturation temperature from $5^{\circ}C\;to\;15^{\circ}C$. The heat transfer coefficient curve shows a decreasing trend after a certain quality (critical quality). The critical quality decreases as the heat flux increases, and as the mass flux decreases. The early dryout at a high heat flux results in a unique 'cross-over' of the heat transfer coefficient curves. The heat transfer coefficient increases as the mass flux increases. At a low quality region, however, the effect of mass flux is not prominent. The heat transfer coefficient increases as the saturation temperature increases. The effect of saturation temperature, however, diminishes as the heat flux decreases. Both the Shah and the Kandlikar correlations un-derpredict the low mass flux and overpredict the high mass flux data.

직접접촉식 열교환기내에서 물과 배기가스의 직접접촉에 의한 열 및 물질전달 (Heat and Mass Transfer between Hot Waste Gas and Cold Water in a Direct Contact Heat Exchanger)

  • 이금배
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1171-1178
    • /
    • 1992
  • 본 연구에서는 직접접촉식 열교환기를 이용한 실험을 통하여 열교환기 설계에 가장 중요한 열교환기 단위 체적당 총괄 열전달 계수를 시스템의 작동조건에 따라 구 하여 실제 설계자료로 이용하는 데 그 목적이 있다.

복합각도 요철을 가지는 사각 덕트 내의 열전달 및 압력강하 특성 (Characteristics of Heat/Mass Transfer and Pressure Drop in a Square Duct with Compound-Angled Rib Turbulaters)

  • 최청;이동호;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.325-333
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics inside the cooling passage of the gas-turbine blades. It is important to increase not only the heat transfer rates but also the uniformity of heat transfer in the cooling passage. The square duct has compound-angled ribs with $60^{\circ},\;70^{\circ}$ and $90^{\circ}$ attack angles, which are installed on the test plate surfaces. a naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy. The ribs disturb the main flow resulting in the recirculation and secondary flows near the ribbed wall and the vertices near the side-wall. The local heat transfer and the secondary flow in the duct are changed largely according to the rib orientation. Therefore, geometry and arrangement of the ribs are important fur the advantageous cooling performance. The angled ribs increase the heat transfer discrepancy between the wall and center regions because of the interaction of the secondary flows. The average heat/mass transfer coefficient and pressure drop of the ribs with the $60^{\circ}$ $-90^{\circ}$ compound-angle are higher than those with the $60^{\circ}$ attack angle. Also, the thermal efficiency of the compound-angled rib is higher than that with the $60^{\circ}$ attack angle. The uniformity of heat/mass transfer coefficient on the cross ribs may is higher than that on the parallel ribs array.

  • PDF

대체냉매의 2중관 응축기 열 및 물질전달과 성능평가 (Heat and Mass Transfer Characteristics and Performance Evaluation of a Double-Tube Condenser for an Alternative Refrigerant)

  • 이상무;박병덕;소산번
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.468-476
    • /
    • 2002
  • This paper deals with heat and mass transfer characteristics and performance evaluation of a counter flow double-tube condenser for a multi-component refrigerant mixture. The local heat and mass transfer characteristics of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a are evaluated for a counter flow double-tube condenser cooled by water. Then, the local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, heat flux and condensation mass flux are obtained. The heat exchange performance for ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a on the total pressure drop and the heat transfer characteristics are also compared with those for R404A, R410A, R502, R22, R32, Rl23 and R134a.

수평미세관내 R-290의 비등열전달 특성 (Boiling Heat Transfer Characteristics of R-290 in Horizontal Minichannel)

  • 최광일;;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.68-73
    • /
    • 2006
  • The present paper deals with an experimental study of boiling heat transfer characteristics of R-290, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method applied for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. The experiments were conducted with R-290 with purity of 99.99% at saturation temperature of 0 to $10^{\circ}C$. The range of mass flux is $50{\sim}250kg/m^2s$ and heat flux is $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increases with increasing mass flux and saturation temperature, wherein the effect of mass flux is higher than that of the saturation temperature, whereas the heat flux has a low effect on increasing heat transfer coefficient. The significant effect of mass flux on heat transfer coefficient is shown at high quality, the effect of heat flux on heat transfer coefficient at low quality shows a domination of nucleate boiling contribution. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. Zang et al.'s correlation(2004) gave the best prediction of heat transfer coefficient.

  • PDF

$90^{\circ}$요철이 설치된 회전하는 정사각 이차 유로에서의 열/물질전달 특성 (HEAT/MASS TRANSFER CHARACTERISTICS IN ROTATING TWO-PASS SQUARE CHANNELS WITH $90^{\circ}$RIBS)

  • 김경민;김상인;김윤영;이동호;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.436-441
    • /
    • 2003
  • The present study investigates heat/mass transfer characteristics in rotating two-pass ducts of three different aspect ratios with 90-ribbed surfaces. The results show that the flows generated by the 180-turn, rib turbulators, and duct rotation. The curvature of the 180-turn produces Dean vortices causing high heat/mass transfer in the turning region and in the upstream region of the second-pass. The rib turbulators disturb the main flow by producing reattachment and separation near the ribbed surfaces, and increase heat/mass transfer in the region between the ribs. As the rotation number increases, the heat/mass transfer discrepancy between the leading and the trailing surfaces become larger.

  • PDF

APPLICATIONS OF ELECTROPLATING METHOD FOR HEAT TRANSFER STUDIES USING ANALOGY CONCEPT

  • Ko, Sang-Hyuk;Moon, Deok-Won;Chung, Bum-Jin
    • Nuclear Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.251-258
    • /
    • 2006
  • This study presents an idea of using analogy concept to the heat transfer studies regarding the HTGR development. Theoretical backgrounds regarding the idea were reviewed. In order to investigate the predictability of a mass transfer system for heat transfer system phenomenology, an electroplating system coupled with a limiting current technique was adopted. Test facilities for laminar forced convection and natural convections under laminar and turbulent conditions were constructed, for which heat transfer correlations are known. The test results showed a close agreement between mass transfer and heat transfer systems, which is an encouraging indication of the validity of the analogy theory and the experimental methodology adopted. This paper shows the potential of the experimental method that validates the little-understood heat transfer phenomena, even in complex geometries such as HTGR.

Study on the Equilibrium Point of Heat and Mass Transfer between Liquid Desiccant and Humid Air with in the Solar Air Conditioning System

  • Sukmaji, I.C.;Rahmanto, H.;Agung, B.;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.161-167
    • /
    • 2009
  • The liquid solar air conditioning system is introduced as an alternative solution to control air condition and to save electrical energy consumption. The heat and mass transfer performances of dehumidifier/regenerator in liquid solar air conditioning system are influenced by air and desiccant condition. The application of this system, the thermal energy from the sun and inlet air are unable to control, but operation parameter of other components such as pump, fan and sensible cooling unit are able to control. The equilibrium point of heat and mass transfer are the liquid desiccant and inlet air conditions, where, the heat and mass are not transferred between the liquid desiccant and vapor air. By knowing equilibrium point of heat and mass transfer, the suitable optimal desiccant conditions for certain air condition are funded. This present experiment study is investigated the equilibrium point heat and mass transfer in various air and desiccant temperature. The benefit of equilibrium point heat and mass transfer will be helpful in choose and design proper component to optimize electrical energy consumption.

  • PDF

평판에 분사된 분무충돌제트의 냉각특성에 대한 실험적 연구 (An experimental study on cooling characteristics of mist impinging jet on a flat plate)

  • 전상욱;정원석;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.528-533
    • /
    • 2001
  • An experimental study is carried out to investigate the effects of air and water mass flow rates on cooling characteristics of mist impinging jet on a flat plate. Experiments are conducted with air mass flow rates from 0.0 to 3.0 g/s, and water mass flow rates from 5.0 to 20.0 g/s. An air-atomizing nozzle is used for the purpose of controlling air and water mass flow rates. In this study, a new test section is designed to obtain local heat transfer coefficient distributions. Heat transfer characteristics of the mist impinging jet are explained with the aid of flow visualization. Surface temperature and heat transfer coefficient distributions become more uniform as air mass flow rate increases, and that the increases in water flow rate mainly enhance cooling performance. Air mass flow rate weakly influences averaged heat transfer coefficient when water mass flow rate is low, but averaged heat transfer coefficient increases remarkably as air mass flow rate in case of high water mass flow rate.

  • PDF