• 제목/요약/키워드: Heat Transfer Tube

검색결과 1,311건 처리시간 0.028초

확관을 고려한 불균일 내면가공관의 전열특성 (Heat Transfer Characteristics of the Non-Uniform Grooved Tube Considering Tube Expansion)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.553-559
    • /
    • 2012
  • A plate-fin heat exchanger is a type of heat exchanger widely used in air conditioners, and tubes and fins are tightly assembled by the mechanical expansion process of tubes. The tube expansion process deforms the grooves inside the tube, and the groove shapes also affect the adhesion between tubes and fins. In this study, the adhesion and heat transfer performance affected by the tube expansion of the non-uniform groove shape tube with different heights are investigated by both analysis and experiments. From the analysis method, it was shown that the contact pressure of non-uniform groove tube is higher than that of the uniform groove tube, and the most appropriate high groove number of the non-uniform groove tube is designed for the maximum contact pressure. From the experimental results, the decreasing rate of the condensation heat transfer coefficient is smaller in the non-uniform groove tube with different heights, compared to the conventional uniform groove tube. Also, the air-side heat transfer coefficient of the non-uniform groove tube with different heights is higher than that of the uniform groove tubes.

세관을 이용한 Tube-in-Tube 열교환기내 R-22, R-407C 및 R-410A 응축열전달 특성 (Condensation Heat Transfer Characteristics of Tube-in-Tube Heat Exchanger using Small Diameter Tubes with R-22, R-407C and R-410A)

  • 박우종;최광일;박기원;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.657-662
    • /
    • 2006
  • The present paper dealt with an experimental study of condensation heat transfer coefficients with refrigerant R-22, R-407C and R-410A, and was focused on pressure gradient and heat transfer coefficient in horizontal tube-in-tube heat exchangers using inner diameter of 4 mm, 3 mm and 2 mm in a 16.91 mm tube and length of 3,000 mm. Experiments were performed at inlet saturation temperature of 35 to $45^{\circ}C$ and mass flux ranges from 200 to $600 kg/m^2s$. The pressure gradient with inner tube diameter of 4.0 mm is higher 2.5 times than that of 8.0 mm. In tube-in-tube HEX, the pressure gradient of R-410A were lower than those of R-22 and R-407C. The condensation heat transfer coefficients increased with mass flux increase, but they decreased with saturation temperature increased. Condensation heat transfer coefficients of R-410A were a little higher than those of R-22 and R-407C. The condensation heat transfer coefficients of tube-in-tube HEX were about 40% higher than those of double tube HEX.

  • PDF

핀-관 열교환기에서 개별 열의 열전달 효과 (Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers)

  • 정지환;장근선;이현우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.238-244
    • /
    • 2003
  • An experimental study was performed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance was measured using air-enthalpy type calorimeter. The examined heat exchangers consists of $7{\Phi}$ tube and fin patterns of them are slit and louver types. Equivalent fin spacing are 18 FPI for all samples, and the number of tube rows were 2. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers were used. The frontal air velocity varied from 0.7 to 2.5 m/s. Heat transfer performance for each row are measured. It was observed that the heat transfer coefficient of the 2nd row were smaller than that of the 1st row at low Reynolds number while larger at high Reynolds number.

  • PDF

2열 핀-관 열 교환기의 열별 전열성능 측정 (Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers)

  • 권영철;정지환;장근선;홍기수;진심원
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.280-286
    • /
    • 2004
  • An experimental study is peformed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance is measured using an air-enthalpy type calorimeter. The examined heat exchangers consist of 7mm tube and fin patterns of them are slit and louver types. Equivalent fin spacings are 18 fins per inch(fpi) for all samples, and the number of tube rows are two. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers are used. The frontal air velocity is varied from 0.7 to 2.5㎧. Heat transfer performance for each row is measured. It is observed that the heat transfer coefficient of the second row is smaller than that of the first row at low Reynolds number while larger at high Reynolds number.

수평 평활관과 마이크로핀 관내에서 HFC-134a의 응축 및 증발열전달 특성 (Condensation and evaporation heat transfer characteristics of HFC-134a in a horizontal smooth and a micro-finned tube)

  • 이상천;박병덕;한운혁;이재희
    • 대한기계학회논문집B
    • /
    • 제20권5호
    • /
    • pp.1725-1734
    • /
    • 1996
  • Experimental condensation and evaporation heat transfer coefficients were measured in a horizontal smooth tube and a horizontal micro-finned tube with HFC-134a. The test sections are straight, horizontal tubes with have a 9.52mm outside diameter and about 5000mm long. The micro-finned tube had 60 fins with a height of 0.12mm and a spiral angle of 25.deg.. The condensation test section was a double-pipe type with counter flow configuration. The evaporation test section employed an electic heating method. Enhancement factors which is defined as a ratio of the heat transfer coefficient for micro-finned tube to that for smooth tube, varied from 1.3 to 1.6(mass flux:110~190kg/m$^{2}$s) for condensation and 1.2 to 1.5 (mass flux:70~160kg/m$^{2}$s) for evaporation. The experimental data of condensation and evaporation heat transfer coefficients were compared to several empirical correlations. Based on these comparisons, modified correlations of the condensation and evaporation heat transfer coefficient for both smooth and micro-finned tubes were proposed.

공랭형 수직원관 흡수기에서의 열 및 물질전달 해석 (Analysis of heat and mass transfer in a vertical tube absorber cooled by air)

  • 김선창;오명도;이재헌
    • 대한기계학회논문집B
    • /
    • 제20권10호
    • /
    • pp.3293-3303
    • /
    • 1996
  • Numerical analyses have been performed to estimate the absorption heat and mass transfer coefficients in absorption process of the LiBr aqueous solution and the total heat and mass transfer rates in a vertical tube absorber which is coolING ed by air. Axisymmetric cylindrical coordinate system was adopted to model the circular tube and the transport equations were solved by the finite volume method. Absorption behaviors of heat and mass transfer were analyzed through falling film of the LiBr aqueous solution contacted by water vapor in tube. Effects of film Reynolds number on heat and mass transfer coefficients have been also investigated. Especially, effects of tube diameter have been considered to observe the total heat and mass transfer rates through falling film along the tube. Based on the analysis it has been found that the total mass transfer rate increases rapidly in a region with low film Reynolds number(10 ~ 40) as the film Reynolds number increases, while decreases beyond that region. The total heat and mass transfer rates increase with increasing the tube diameter.

Experimental Investigation of Heat Transfer in Absorber with Small Diameter Tube

  • Phan Thanh Tong;Moon Choon-Geun;Kim Jae-Dol;Yoon Jung-In
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.261-262
    • /
    • 2006
  • The effect of tube diameter on heat transfer characteristics of absorber in absorption chiller/heater using LiBr solution as a working fluid has been investigated by experimental study to develop a high performance and compact absorber. A system Includes a tube absorber, a generator, solution distribution system and cooling water system was set up. The diameter of the heat exchanger tube inside absorber was changed from 15.88mm to 12.7mm and 9.52mm. The experimental results show that the heat transfer coefficient, Nusselt number and heat flux increase as solution flow rate and cooling water flow rate increase. The heat transfer performance increases as tube diameter decreases. Among three different tube diameters, the smallest tube diameter 9.52mm has highest heat transfer performance. A comparison of the heat transfer coefficient obtained by the present study with those of previous experimental results showed good overall agreement.

  • PDF

핀관 열교환기에서 확관율이 접촉열전달계수에 미치는 영향 (Effect of Expansion Ratio on Contact Heat Transfer Coefficient in Fin-Tube Heat Exchanger)

  • 이상무;박병덕
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.45-50
    • /
    • 2012
  • The plate fin and tube type of heat exchanger is widely used in air conditioner, and the heat exchanger is assembled by the mechanical expansion of copper tubes and fastening the aluminum fin. The objective of the present study is to investigate how the mechanical expansion of copper tube affects on the heat transfer performance of a plate fin and tube type heat exchanger. This study has been performed by experimental and numerical methods. The numerical and experimental results show that the tube expansion ratio has a influence on the heat transfer performance. Within the tested expansion ratio, the contact pressure shows the peak value and it decreases as the expansion ratio increases. Air-side heat transfer coefficient increases until the expansion ratio reaches 1.23, and then decreases with the similar pattern to the contact pressure. Also, contact heat transfer coefficient shows the maximum when the contact pressure is highest as well as the air-side heat transfer coefficient.

수평 원형전열관의 핀효과에 의한 응축 및 비등 열전달촉진에 관한 연구 (1)-튜브외부 비등- (A Study on the Improvement of Condensation and Boiling Heat Transfer on Horizntal Tube by Fin Effect(l)-Shellside Boiling-)

  • 한규일;조동현
    • 대한기계학회논문집
    • /
    • 제18권5호
    • /
    • pp.1264-1274
    • /
    • 1994
  • Heat transfer performance of integral-fin tube which is used in recipro turbo refrigerator or high compact heat exchangers is studied. Eight tubes with trapezoidal shaped integral-fins having fin densities from 748 to 1654 fpm and 10, 30 internal grooves are tested. A plain tube having the same(inner and outer) diameter as the fin tubes is also tested for comparison. Pool boiling heat transfer of R-11 is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at saturation state of 1 bar on the outside tube surface and heat is supplied by not water which circulates inside of the tube. From the result of eight fin tubes and one plain tube tested, a tube having 1299 fpm-30 grooves shows the best performance. A maximum overall heat transfer coefficient of this tube is about 4000 $W/m^{2}K$ at 2.8m/s of water velocity. The maximum heat transfer enhancement (i.e., the ratio of overall heat transfer coefficients of finned to plain tubes)is about 2.1.

나노입자를 포함한 자연냉매의 마이크로 휜관 응축 열전달 특성 (Condensing Heat Transfer of Natural Refrigerants with Nanoparticles in Enhanced Tube)

  • 이호생
    • 동력기계공학회지
    • /
    • 제12권3호
    • /
    • pp.19-25
    • /
    • 2008
  • This paper deals with the heat transfer and pressure drop characteristics of R-290 (Propane), R-600a (Iso-butane) and R-1270 (Propylene) as an environment friendly refrigerant and R-22 as a HCFC's refrigerant for condensing. The test section is a horizontal double pipe heat exchanger. Condensing heat transfer and pressure drop measurements were Peformed for 12.70 mm micro-fin tube and compared with the results in smooth tube. The local condensing heat transfer coefficients of hydrocarbon refrigerants were superior to those of R-22 and the maximum increasing rate of heat transfer coefficient was found in R-600a. The average condensing heat transfer coefficients in hydrocarbon refrigerants showed 20 to 28% higher values than those of R-22. Hydrocarbon refrigerants have a higher pressure drop than that of R-22 with respect to refrigerant qualify and mass flux. Also, the condensing heat transfer coefficient and pressure drop of working fluids in smooth and micro-fin tube were compared. The heat transfer enhancement factor (EF) between smooth and micro-fin tube varied from 2.2 to 2.6 in all experimental conditions.

  • PDF