• 제목/요약/키워드: Heat Transfer Mechanism

검색결과 277건 처리시간 0.02초

Heat Transfer Analysis for Endothermic Reacting Fluids

  • Kimura, Hiroyuki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.346-357
    • /
    • 2008
  • Endothermic fuels are known as a probable fuel for hypersonic atmospheric flight vehicles and advanced propulsion systems, as well as cryogenic fuels. Especially, from the standpoint of the advanced regenerative cooling use, they are quite useful as a coolant fuel because of their large heat sink due to their chemical decompositions; so-called endothermic cooling effect. However, no heat transfer equations have been proposed taking into account such endothermic reactive behaviors concretely. This paper describes an analytical method for evaluation of the heat transfer rates between endothermic reacting coolant fuel and coolant-side wall in the regenerative cooling passages. Heat transfer mechanism is indicated based on a classical transport-phenomenological approach. A new relational expression of Nusselt number ratio for forcedconvective heat transfer with such endothermic reactions is also proposed by theoretical approaches using some classical hypotheses. Its applicability is assessed provisionally by comparison with confirmed results of heated tube tests for supercritical JP-7 fuel carried out at NASA Lewis Research Center, using its heat sink characteristics evaluated by United Technologies Research Center(UTRC). As a result, it has been suggested that the proposed relational equation is applicable to the evaluation of enhancement of Nusselt numbers due to such reactions in developed turbulent flows such as in the regenerative cooling passages.

  • PDF

열펌프-잠열축열 온돌 시스템 연구 (A Study on the Heat Pump-Latent Heat Storage Type)

  • 송현갑;박문수
    • Journal of Biosystems Engineering
    • /
    • 제26권4호
    • /
    • pp.385-390
    • /
    • 2001
  • The Ondol system using both air-to-water heat pump and PCM(Phase Change Material) was constructed, and the effects of ambient air temperature on COP(Coefficient of Performance) of heat pump, the amount of heat supplied to the Ondol in the heating process, the heat storage in the PCM and the variation of Ondol room temperature were analyzed. The results from this study could be summarized as follows: 1. The COP of the heat pump (3 PS) was in proportion to the ambient air temperature. 2. When the ambient air temperature was varied between -10$^{\circ}C$ and -7$^{\circ}C$, the air temperature in the Ondol room was maintained between 16$^{\circ}C$ and 22$^{\circ}C$. As the results, it was certified that the heat pump-latent heat storage type Ondol system could be a comfortable residential heating system in the winter. 3. The maximum radiation and convection heat transfer from Ondol surface was 206.2 kJ/㎥hr and 82.6 kJ/㎥hr respectively. As the results, it could be confirmed that the radiation was major heat transfer mechanism for the Ondol room heating.

  • PDF

열전달 촉진관에서 탄화수소계 냉매의 풀비등 열전달계수 (Pool Boiling Heat Transfer Coefficients of Hydrocarbon Refrigerants on Various Enhanced Tubes)

  • 박기정;정동수
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.1017-1024
    • /
    • 2006
  • In this work, pool boiling heat transfer coefficients (HTCs) of five hydrocarbon refrigerants of propylene, propane, isobutane, butane and dimethylether (DME) were measured at the liquid temperature of $7^{\circ}C$ on a 26 fpi low fin tube, Turbo-B, and Thermoexcel-E tubes. All data were taken from 80 to $10kW/m^2$ in the decreasing order of heat flux. The data of hydrocarbon refrigerants showed a typical trend that nucleate boiling HTCs obtained on enhanced tubes also increase with the vapor pressure. Fluids with lower reduced pressure such as DME, isobutane, and butane took more advantage of the heat transfer enhancement mechanism of enhanced tubes than those enhancement ratios of $2.3\sim9.4$ among the tubes tested due to its sub-channels and re-entrant cavities.

PREDICTION OF A HEAT TRANSFER TO CO2 FLOWING IN AN UPWARD PATH AT A SUPERCRITICAL PRESSURE

  • Cho, Bong-Hyun;Kim, Young-In;Bae, Yoon-Yeong
    • Nuclear Engineering and Technology
    • /
    • 제41권7호
    • /
    • pp.907-920
    • /
    • 2009
  • This study was performed to evaluate the prediction capability of a commercial CFD code and to investigate the effects of different geometries such as a 4.4 mm tube and an 8/10 mm annular channel on the detailed flow structures. A numerical simulation was performed for the conditions, at which the experimental data was produced by the test facility SPHINX. A 2-dimensional axisymmetric steady flow was assumed for computational simplicity. The RNG $\kappa-\varepsilon$ turbulence model (RNG) with an enhanced wall treatment option, SST $\kappa-\omega$ (SST) and low Reynolds Abid turbulence model (ABD) were employed and the numerical predictions were compared with the experimental data generated from the experiment. The effects of the geometry on heat transfer were investigated. The flow and temperature fields were also examined in order to investigate the mechanism of heat transfer near the wall. The local heat transfer coefficient predicted by the RNG model is very close to the measurement result for the tube. In contrast, the local heat transfer coefficient predicted by the SST and ABD models is closer to the measurement for the annular channel.

직접수치모사를 이용한 수직원형관내 초임계압 유체의 난류 열전달 특성 연구 (Direct Numerical Simulation of Turbulent Heat Transfer to Fluids at Supercritical Pressure Flowing in Vertical Tubes)

  • 배중헌;유정열;최해천
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1302-1314
    • /
    • 2004
  • Turbulent heat transfer to $CO_2$ at supercritical pressure flowing in vertical tubes is investigated using direct numerical simulation (DNS). A conservative space-time discretization scheme for variable-density flows at low Mach numbers is adopted in the present study to treat steep variations of fluid properties at supercritical pressure just above the thermodynamic critical point. The fluid properties at these conditions are obtained using PROPATH and used in the form of tables in the simulations. The buoyancy influence induced by strong variation of density across the pseudo-critical temperature proved to play a major role in turbulent heat transfer at supercritical state. Depending on the degree of buoyancy influence, turbulent heat transfer may be enhanced or significantly deteriorated, resulting in local hot spots along the heated surface. Based on the results of the present DNS combined with theoretical considerations, the physical mechanism of this local heat transfer deterioration is elucidated.

四角리브를 갖는 傳熱面에 衝突하는 2次元 噴流의 熱傳達에 관한 硏究 (Heat Transfer of a Two-Dimensional Jet Impinging on the Wall with Transverse Repeated Ribs of Square Cross-Section)

  • 김상필;서정윤
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.214-221
    • /
    • 1987
  • 본 논문에서는 2차원충돌분류에서 사각리브(rib)를 갖는 요철형전열면에 대한 실험에 관한 것이며, 리브의 높이를 (e=5nm) 일정하게 하고 리브의 피치(p=25,35,50 nm) 변화, 노즐출구와 전열면간 거이(H/B=1~14) 및 노즐출구유속(u$_{e}$=12.30~ 18.07m/s)의 변화에 따른 전열특성을 실험적으로 구명하고 평판전열면의 경우와 비교 검토한다. 또한 스모크와이어(smoke-wire)법으로 평판 및 리브판에서의 유체의 거동 을 가시화하여 전열기구의 정성적 특성을 검토하는데 목적이 있다.

60 μm의 전극 간극을 갖는 FET식 MWCNT 가스센서에서 열 유동 현상 (Thermal Transport Phenomena in the FET Typed MWCNT Gas Sensor with the 60 μm Electrode Distance)

  • 장경욱
    • 한국전기전자재료학회논문지
    • /
    • 제28권6호
    • /
    • pp.403-407
    • /
    • 2015
  • Generally, MWCNT, with thermal, chemical and electrical superiority, is manufactured with CVD (chemical vapor deposition). Using MWCNT, it is comonly used as gas sensor of MOS-FET structure. In this study, in order to repeatedly detect gases, the author had to effectively eliminate gases absorbed in a MWCNT sensor. So as to eliminate gases absorbed in a MWCNT sensor, the sensor was applied heat of 423[K], and in order to observe how the applied heat was diffused within the sensor, the author interpreted the diffusion process of heat, using COMSOL interpretation program. In order to interpret the diffusion process of heat, the author progressed modeling with the structure of MWCNT gas sensor in 2-dimension, and defining heat transfer velocity($u={\Delta}T/{\Delta}x$), accorded to governing equation within the sensor, the author proposed heat transfer mechanism.

A2024 와 SM45C 마찰용접의 열전달 해석 (Heat Transfer Analysis of Friction Welding of A2024 to SM45C)

  • 이상윤;윤병수
    • 한국공작기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.65-70
    • /
    • 2001
  • The hear transfer mechanism initiating the friction welding is examined and a transient three dimensional heat conduc-tion model for the welding of two dissimilar cylindrical metal bars is investigated. The cylindrical metal bars are made of materials made of A2024 and SM 45C. Numerical simulations of heat flow are performed using the finite volume method. Respectively. Commercial FLUENT code is used in the heat flow simulation and maximum temperature and distribution of temperature are calculated. Temperature of friction welded joining face is compared with the temperature distribution measured by experiment and numerical simulation. The maximum temperature of friction welded joining face is lower than melting point of A2024-T6 aluminum alloy using insert metal. The temperature distribution of friction welded join- ing face with insert metal is more uniform than that of without inset metal.

  • PDF

Friction Factor and Heat Transfer in Equilateral Triangular Ducts with Surface Roughness

  • Ahn, Soo-Whan
    • Journal of Mechanical Science and Technology
    • /
    • 제15권5호
    • /
    • pp.639-645
    • /
    • 2001
  • Experimental investigations were conducted to study forced convection of fully developed turbulent flows in horizontal equilateral triangular ducts with different surface roughness pitch ratios (P/e) of 4, 8, and 16 on one side. The ducts bottom wall was heated uniformly and the other surfaces were thermally insulated. To understand heat transfer enhancement mechanism, heat transfer rates were measured. Smooth triangular ducts were also tested for benchmark purposes. The results were compared with previous results for similarly configured channels, at which they were roughened by regularly spaced transverse ribs in the rectangular and circular channels.

  • PDF

회전 피스톤형 로터리 압축기 내의 열전달이 성능특성에 미치는 영향에 관한 연구 (Effect of the Heat Transfer on the Performance Characteristics of Rolling Piston Type Rotary Compressors for Air Conditioner)

  • 양동준;정진택;박진무;황선웅
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.763-770
    • /
    • 2001
  • The high pressure side rotary compressor is investigated in this study. The temperatures at 29 points of main components and the refrigerant and the performance of the instrumented compressor are measured at various operating conditions. The complex heat transfer mechanism between the components, such s cylinder, suction pipe and stator of motor, is fairly clarified. It is also confirmed that the achievement of a high efficiency by reducing the heat transfer loss in the rotary compressor is possible.

  • PDF